Repair To Roof Ac Sheets False Ceiling Under Age B / R - I At Itarana Alwar Repair To Roof Ac Sheets False Ceiling Under Age B / R - I At Itarana Alwar, Alwar-Rajasthan

Military Engineer Services-MES has published Repair To Roof Ac Sheets False Ceiling Under Age B / R - I At Itarana Alwar Repair To Roof Ac Sheets False Ceiling Under Age B / R - I At Itarana Alwar. Submission Date for this Tender is 25-12-2021. Shed Construction Tenders in Alwar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

30079036
Corrigendum : Repair To Roof Ac Sheets False Ceiling Under Age B / R - I At Itarana Alwar Repair To Roof Ac Sheets False Ceiling Under Age B / R - I At Itarana Alwar
Open Tender
Indian
Rajasthan
Alwar
25-12-2021

Tender Details

Repair To Roof Ac Sheets False Ceiling Under Age B / R - I At Itarana Alwar Repair To Roof Ac Sheets False Ceiling Under Age B / R - I At Itarana Alwar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR TO ROOF, AC SHEETS, FALSE CEILING UNDER AGE B/R - I AT ITARANA ALWAR
Sl. No. Item Description
1Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets complete all as specified.
2Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc complete all as specified.
3S&F 6mm thick Non asbestos cement plain building boards, fixed to steel frame work in ceiling complete all as specified and directed. Note :The steel frame work shall be measured and paid for seperately.
4Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge.
5Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
6Material and labour glazed ceramic tiles (coloured) Ist quality 350mm x 450mm x 7 mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
7M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) (Ist quality) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
8M&L for vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
9M&L for vitrified ceramic tiles 10mm thick (square/rectangular) (Ist quality), polished, coloured (light shade as approved), area of each tile exceeding 0.36 sqm but not exc .42 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar 1:4 complete all as specified and as directed.
10M&L for PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in levelling course of floors and roofs25mm thick finished fair & even complete all as specified & as directed.
11S&F glass dividing strips 3mm thick and 38mm wide & fixed in position as directed.
12M&L for 50 mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as inplinth protection surface finished fair and evencomplete all as specified.
13Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar.
14M&L machine cut Kota stone slab flooring 20 to 25mm thicklaid over & including screed bed or bedding layer of 20mm thick in CM 1:6 and jointedwith grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
15M&L machine cut Kota stone slab 10 to 15mm thick , as in riser of step, skirting, dado etc. laid over & including screed bed or bedding layer of 10mm thick in CM 1:4 and jointedwith grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
16M&L 25mm thick factory made coloured interlocking designer polished floor tiles (Ultra pattern) of Grade M-35 of shape and size as directed, laid over & including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
17M&L factory made 60mm thick vibratory moulded precast cement concrete interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as Specified & directed.
18M&L for 100 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as insub base, surface finished fair and evencomplete all as specified.
19M&L for precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in kerb stone block (factory casted) with plain fair faces, including weathering, slightly rounded or chamfered angle throating, with plain or interlocking joints and setting in cement mortar 1:4, complete, all as directed.
20Disconnecting existing tank of capacity exc 250 & not exc 500 litre, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position including cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes, etc complete all as specified & as directed.
21Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
22Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge.
23S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or ‘L’ type or ‘J’ type or cranked hooks bolts complete all as specified & directed.
24S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors and similar works of Gde E-165(Fe 290) including welding etc. complete all as specified & as directed.
25Material and labour preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
26M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
27M&L in repair galvanised steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
28M&Lin repair galvanised steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
29Supply only integral water proofing compound (ISI marked).
30M&L for rendering 15mm thick in cement plaster 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished fair & even complete all as specified.
31M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
32M&L for 20mm thick Granite slab of approved shade, as in platform etc, bedded & jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish i.e. full granite polish as per local trade practice) including required cutting to suit the size of oval type wash hand basin over & including 20mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
33M&L rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair face of brick work of walls, mixed with water proofing compound (ISI marked), finished even & smooth without using extra cement complete all as specified. Note : - Supply only water proofing compound shall be measured and paid for separately.
34M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including1mm thick white wall care puttyall as specified & as directed.
35Material and labour preparation of newly plastered surface of ceiling & applying three coats of white wash complete all as specified.
36M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applyingtwo coats of oil emulsion distemper (OBD) of approved shade/tint over &wall care puttyall as specified & as directed.
37Material and labour preparation of newly plastered surface of walls & applying two coats of cement base paint over a coat of primer complete all as specified.
38M&L preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint of approved shade/tint complete all as specified & as directed.
39M&L for cutting holes in stone walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3, not exc. half brick thick (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall)
40Demolition of existing lime concrete/PCC padding, roof treatment of any thickness laid over RCC roof/chajja etc.,removing complete layer of bitumen under concrete/PCC padding, cleaning and washing of roof with water to remove dust etc as preparation to receive treatment all as directed by Engineer-in-charge.
41Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.5 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufacturedby M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydrostop water proofing memdrane manufactured by M/S TIKIDAN as approved by GE, black finish reinforced with non-woven polyester matt (weighing not less than 150 gm/Sqm), with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd}at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, applied@1.20 Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing.(iii)The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv)In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen. (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate. (vii) The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.
42M&Lfor padding with PCC 1:2:4,type B0 (using 12.5 mm graded crushed stone aggregate ) laid to a average thickness 50mm thick over roof slab etc as in levelling course, finished even & smooth w/o using extra cement.
43Disconnecting & taking down the existing unserviceable water tank and Supply and fixing in repairs 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
44M&L for false ceiling complete with Armgyp-FB ceiling tiles of size 595 x 595mm, 9mm thick (as approved by GE) fixed with and including galvanized iron powder coated inverted ‘Tee’ or ‘L’ section (concealed GI frame work) suspended from ceiling with provision of galvanized wire 4 mm dia and wall taping screw including butterfly clips, hold down clips for fixing the board to frame complete all as per manufacturer’s instructions, complete, all as directed and specified. (a)Size of grid – 610 x 610 mm. (b)Size of main Tee – 39 x 24.70 x 0.80 mm. (c)Size of cross Tee – 39 x 24.70 x 0.80 mm. (d)Size of wall angle – 22.20 x 22.20 x 0.65 mm.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail