}

Bids Are invited for Fuse1 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KACURRENT, RATED : 25A VOLTAGE, RATED : 415VAC/240DC FREQUENCY : 50HZBOLTED DESIGN T SERIES OFF-SET TAG ,TYPE TIA , CONFORMING TO IS 13703(PART 2,SEC 1)/IEC-West Bengal

Steel Authority Of India Limited-SAIL has published Bids Are invited for Fuse1 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KACURRENT, RATED : 25A VOLTAGE, RATED : 415VAC/240DC FREQUENCY : 50HZBOLTED DESIGN T SERIES OFF-SET TAG ,TYPE TIA , CONFORMING TO IS 13703(PART 2,SEC 1)/IEC. Submission Date for this Tender is 06-12-2021. Fuses Tenders in West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

30029789
Bids Are invited for Fuse1 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KACURRENT, RATED : 25A VOLTAGE, RATED : 415VAC/240DC FREQUENCY : 50HZBOLTED DESIGN T SERIES OFF-SET TAG ,TYPE TIA , CONFORMING TO IS 13703(PART 2,SEC 1)/IEC
Open Tender
Indian
West Bengal
06-12-2021

Tender Details

Bids Are invited for Fuse1 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KACURRENT, RATED : 25A VOLTAGE, RATED : 415VAC/240DC FREQUENCY : 50HZBOLTED DESIGN T SERIES OFF-SET TAG ,TYPE TIA , CONFORMING TO IS 13703(PART 2,SEC 1)/IEC 60269-2 , MAKE:HPL/ABB/SIEMENS/L&T/STANDARD/C&S/GE/INDOASEAN/HAVELLS , Fuse2 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KAVOLTAGE, RATED : 500VAC CURRENT, RATED : 25A FREQUENCY :50HZ SIZE : 00CONTINENTAL DESIGN DIN TYPE, ,CONFORMING TO IS 13703(PART 2,SEC 1)/IEC60269-2 ,MAKE : HPL/ABB/SIEMENS/L&T/ STANDARD/C&S/GE/INDOASEAN/HAVELLS , Fuse3 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KAVOLTAGE, RATED : 500VAC CURRENT, RATED : 20A SIZE : 00 FREQUENCY : 50HZCONTINENTAL DESIGN DIN TYPE, ,CONFORMING TO IS 13703 (PART 2,SEC 1)/IEC60269-2, MAKE : HPL/ABB/SIEMENS/L&T/STANDARD/C&S/ GE/INDOASEAN/HAVELLS , Fuse4 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KACURRENT, RATED : 32A VOLTAGE, RATED : 415VAC/240DC FREQUENCY : 50HZBOLTED DESIGN T-SERIES OFF-SET TAGTYPE TIA ,CONFORMING TO IS 13703(PART2,SEC 1)/IEC 60269-2 , MAKE :HPL/ABB/SIEMENS/L&T/STANDARD/C&S/GE/INDOASEAN/HAVELLS , Fuse5 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KAVOLTAGE, RATED : 500VAC CURRENT, RATED : 32A SIZE : 00 FREQUENCY : 50HZCONTINENTAL DESIGN DIN TYPE, CONFORMING TO IS 13703 (PART 2,SEC 1)/IEC60269-2 ,MAKE : HPL/ABB/SIEMENS/L&T/STANDARD/C&S/ GE/INDOASEAN/HAVELLS , Fuse6 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KAVOLTAGE, RATED : 500VAC CURRENT, RATED : 50A SIZE : 00 FREQUENCY : 50HZCONTINENTAL DESIGN DIN TYPECONFORMING TO IS 13703 (PART 2,SEC 1)/IEC60269-2 ,MAKE: HPL/ABB/SIEMENS/L&T/STANDARD/C&S/GE/ INDOASEAN/HAVELLS , Fuse7 - LOW VOLTAGE FUSE TYPE : HIGH RUPTURING CAPACITY BREAKING CAPACITY : 80KAVOLTAGE, RATED : 500VAC CURRENT, RATED : 63A SIZE : 00 FREQUENCY : 50HZCONTINENTAL DESIGN DIN TYPE,,CONFORMING TO IS

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail