Bids Are Invited For Digital Magnetic Stirrer With Hot Plate - Capacity-2Ltrnumber Of Stirring Positions: 1Type Of Drive Motor:Dc Motordisplay Option/Output Read Out Option: Digitalmagnetic Stirrer Is: With A Hot Plate Or Some Other Means For Heating The -Bihar

Department Of Science And Technology has published Bids Are Invited For Digital Magnetic Stirrer With Hot Plate - Capacity-2Ltrnumber Of Stirring Positions: 1Type Of Drive Motor:Dc Motordisplay Option/Output Read Out Option: Digitalmagnetic Stirrer Is: With A Hot Plate Or Some Other Means For Heating The . Submission Date for this Tender is 09-12-2021. Uniform Tenders in Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

29958705
Bids Are Invited For Digital Magnetic Stirrer With Hot Plate - Capacity-2Ltrnumber Of Stirring Positions: 1Type Of Drive Motor:Dc Motordisplay Option/Output Read Out Option: Digitalmagnetic Stirrer Is: With A Hot Plate Or Some Other Means For Heating The
Open Tender
Indian
Bihar
09-12-2021

Tender Details

Bids Are Invited For Digital Magnetic Stirrer With Hot Plate - Capacity-2Ltrnumber Of Stirring Positions: 1Type Of Drive Motor:Dc Motordisplay Option/Output Read Out Option: Digitalmagnetic Stirrer Is: With A Hot Plate Or Some Other Means For Heating The Liquidcontroller Type: Electronically Controlled And Programmablespeed Control Accuracy Of Set Speed (+/-) (Rpm): 2-3%Maximum Stirring Capacity Per Position: 2000 Millilitrestainless Steel Top Plate Material, Digital Front Panel, Last Run Memoryce Certified Product (Seller To Furnish Supporting Document To Buyer On Demand)Speedspeed Mode: Variable Speedminimum Speed Possible (Rpm): 50Maximum Speed (Rpm) Of Variable Speed Mode Equipment: 1600Dimensionsexternal Dimension: (Height) 200 Millimetreexternal Dimension: Width 200 Millimetreexternal Dimension: Depth: 50 Millimetrebody Material: Stainless Steelfinish Of Body Material: Powder Coatedtop Plate Finish:Stainless Steelstir Barstir Bar Cover Material: Ptfe Quotedstir Bar Length: 200 Millimetretop Platetop Plate Area Shape:Square Square Top Plate Diameter:100Mmtop Plate Finish:Stainless Steel , Automatic Water Distillation Equipment Double Stage - Electrical Requirements 230 Volts 10 / 50 Hz Single Phasedistillation Water Capacity (Ltr/Hr): 4 Ltr/Hrnumbers Of Built In Quartz Heaters (Nos): 2 Distillation Units Type: Horizontal Built In Quartz Heater Capacity (Kw): 7 Double Stage Glass(Quartz) Distillation Units: Yescooling Water Consumption (Ltr/Hr):120 Ltr/Hr Replaceable Silica Heater: The Horizontal Quartz Jacket Is Fitted With Removable Silica Heater & Screw Threaded Connectors For Ease Of Cleaning.Distillate Temperature Is Approx. B/W 25° To 45° C Which Is Ensured By An Efficient Condenser.The Stand Is Powder Coated For Rust Free Operation & Lustrous Appearance.Cooling Water From The Condenser Is Re-Circulated Into The Boiling Chamber, Hence Saving Energy.Fuse Is Provided For Safety In Case Of Voltage Fluctuation Or Short Circuit.Boiler Is Provided With Replaceable Constant Level Device For Easy Draining & Cleaning Of Boiling Chamber.Additional In- Built Safety Featuresgate Valve: Conserves Cooling Water Wastage In Case Of Power Failure.Flow Switch: In-Built Safety Feature For The Equipment Unit Shut Off In Case Of Cooling Water Failure.Temperature Switch: The Boiler Is Equipped With A Safety Temperature Switch Which Shuts Off The Unit If Water Level In The Boiler Falls Below The Heater, Thus Saving The Glass Parts From Any Damages. , Digital Electronic Balance - Type Of Electronic Weighing Machine: Electronic Precision Pan Balance Rated Load/ Capacity(Kg): 220 Gm Resolution(Gms): 1 Mg Class Type Class-I Display: Led Number Of Display: Single Speed Of Measurement: 4 Second Number Of Scale Division: 1000 Tare Provision: Manual Power Requirement Mains Operated Battery Operated Power Supply: Single Phase Dc Operating Voltage In Volts: 6 Volt Battery Backup: Yes Backup Time(Hour): 10 Battery Type: Non-Rechargeable Battery Rating: Aaa1.5V Type Of Sensing Element: Load Cell Number Of Load Cell/Emfc: 1 Class Of Protection: Ip 65 , Jar Test Apparatus Flocculator - Flocculator (Jar Test Apparatus) Is An Equipment Designed For Testing Water Soluble Polymers Used With Conventional Waste Water Treatment Processes Such As : • Coagulation • Flocculation • Sedimentation In Water • Waste Water Treatment • Other Industrial Applications. It Provides Identical Test Conditions For All Samples. In This Instrument Stirring Shaft For Any Jar Can Be Removed Without Disturbing Other Stirrers. Illuminator Base Made Of Acrylic Sheet Provides Diffused Cold Light Through Floc. Samples.Features:• Microprocessor Based Controls• Programmable Mode• Programmable Rpm Cum Timer Mode• White Light Illumination• On Board Power On/Off• Soft Touch Keypad And Brilliant 16 X 2 A-Numeric Lcd Paddles Made Up Of Stainless Steel• Confirms To Standardstechnical Details:Ø Rotation Speed : 5-150 Rpm (+1 Rpm)Ø Timer : 99:59:59 (Hh:Mm:Ss)Ø Display : 16 X 2 A-Numeric Lcdø Keypad : Soft Touchø No. Of Paddles : 6Ø Drive System : Stepper Modeø Illumination : White Lightø Power : 220/230 Vac, 50Hz , Fluoride Ion Meter (With Fluoride Electrode) - Ph Range & Accuracy: -2.000 - 20.000Ph & ±0.002Phresolution: 0.001,0.01,0.1Ph ( Selectable )Ion Concentration Range: 0.001-19999 Ppm,Mg/L,Mol/L (Selectable Depending On Meas. Range Of Ion Selective Electrode)Ion Concentration Accuracy: ±0.5% Full Scale ( Monovalent),±1% Full Scale (Divalent)Mv Range & Mv Accuracy: -.11999.9 Mv & ±0.2Mvresolution: 0.1/1Mv, Selectabletemperature Range & Accuracy: 0-105°C, 32-221°F & ±0.5°C,±0.9Tcalibration Points: Ion / Ph : Up To 5 Pointsph Buffer Groups: Usa (011.68,4.01,7.00,10.01 ,12A5), Nist (Ph1.68,4.01,6.86,9.18,12.45), Din (011.09,4.65,6.79,923,12.7 Or User Define)Memory And Output:500 Data Sets With Date/Time Stamping, Usb Communication Interface.Connector & Hold Function: Bnc & Selectabletemperature Compensation: 0-100T,32-212 F,Automatic Or Manualstability Conditions: Low Or High, Selectablecalibration Due Reminder: 1 To 31 Days Or Offpower Supply: Dc 5V Adapters, Using Ac 220V / 50Hz,Dimensions Lxwxh (Mm) & Weight: 210 X 188 X 60 & 1.2Kg , Double Beam Uv-Vis Spectrophotometer - Type: Type Of Spectrophotometer: Uv - Visible Type Of Optical System: Double Beam Monochromator Type: Holographic Grating Detector Type: Photodiode Spectral Bandwidth Type: Fixed Bandwidth Light Source Light Source: Deuterium Lamp Diffraction Grating (Lines/Mm):1400 Switching Of Light Source: Automatic Wavelength Setting And Scanning: Automatic Optical Performance Source Wavelength –Minimum: 190 Nanometer Source Wavelength –Maximum: 1100 Nanometer Resolution: 0.3 Nanometer Wavelength Accuracy (+/-): 0.5 Nanometer Bandwidth (Nm): 0.1 Scanning Speed(Nm/Min): 300 Focal Length (Mm): 100 To 149 Photometric Measurement Modes: Transmittance, Absorbance, Concentration (Wavelength, Time) Photometric Absorbance(Max) (Abs) (+/-): 3 Photometric Absorbance Accuracy (Max) (+/-): 0.005 Photometric Transmittance (Max) (+/-): 100 Percent Photometric Transmittance Accuracy (Max) (+/-): 0.1 Percent Photometric Reflectance (Max) (+/-): 0 Percent Photometric Reflectance Accuracy (Max) (+/-): 0.005 Percent Baseline Correction: Automatic Generic Display: In-Built Display Display Type: Lcd With Backlight Display Size: 4 Inch Test Result Printing: Through External Printer Connectivity: Rs 232 Sample Switching/Selection: Manual Capacity Of Sample Holder / Sample Carousel: 6 Maximum Path Length Of Sample: 100 Millimeter Number Of Cuvettes Supplied-Inclusive In The Scope Of Supply: 10 Power Supply: 230 V ± 10, 50 Hz List Of Items And Quantity Of Each Item Included In The Offer: 2 No Of 10Mm Glass Cuvettes Operating Conditions Minimum Operating Temperature: 10 Degrees Celsius Maximum Operating Temperature: 40 Degrees Celsius Operating Humidity (Rh) (%) At 40-Degree C: 80 Percent , Micropipette Single Channel Autoclavable - A) 0.5Ml To 10Mlb) 500 Ml To 5000Ml , Rotary Shaker - Shakers Have Brush Less Dc (Bldc) Motor Having A Wide Speed Range From 50 To 400 Rpm. A Universal Platform Is With Adjustable Rollers And Is Also Suitable To Accommodate Interchangeable Clamps Of Assorted Sizes / Capacities For Holding Conical Flasks, Making The Unit Truly Versatile In Performance.Speed Range- 50 To 400 Rpmplatform Size- 12 X 12 Inchesflasks Capacity (Max)- 5 X 500 Mloverall Dimensionsw X D X H- 320 X 415 X 130 Mmspeed Indicator- Digitaldigital Count Down Timer- 99 Minutesshaking Orbit- 10 Mmsupply: 220-240 Volts, 50 Hz Single Phase.A Variety Of Clamps Are Available Having Capacity Of 500 Ml, 250 Ml, 150 Ml And 100/ 50 Ml (5 No’S Each) , Prestaltic Pump - Flow Range – 0.1Ml/Hr To 1000Ml/Hr Accuracy – ±2% Digital Display Of Functions And Time Auto-Stop With Audible Alarm Battery Back-Up Stores Memory In Case Of Power Failure. , Dissolved Oxygen Meter - Measurement & Range: Dissolved Oxygen - 0 To 20.0 Mg/L. Display: 13 Mm ( 0.5 ) Lcd, 3 1/2 Digits. Accuracy: ± 0.4 Mg/L. (After Calibration Within 23± 5 ?) Resolution: 0.1 Mg/L Power Supply: 006P Dc 9V Battery (Heavy Duty Type). , High Volume Air Sampler - Blower Flow Rate : More Than 1.6 M3 / Min Free Flow Without Resistance.Particulate Sampling : Less Than 2.5Μ (Pm-2.5) Using Pm2.5 Size Selective Inlet At 1.13M3/Min (40Cfm) (Std) Filter Holder : Ss 304 To Accommodate Filter Paper Of Size :25 X 20 Cm.Filter Media : Whatman Gf/A Or Epm – 2000 Or Qm-A Size : 254 X 203 Mmelectronic Control Module Ecm With Constant Flow Controller & Digital Display Of Stp Corrected Flow & Volumedisplay : 16 X 2 Character Alphanumeric Lcd Module With Blue Backlitkeys : 6 Nos.Delay Time : Programmable With Real Time Clocksampling Time : Programmable Upto 199 Hrs. 59 Mts. With Real Time Clock Electronic Time Totalizer : Up To 199 Hrs. 59 Mts.Automatic Sampling Control : Fully Programmable Electronic Timer To Automatically Shut Off System After Preset Time Interval.Flow Measurement : With Exhaust Orifice & Pressure Sensorflow Setting & Display : Range 0.60 To 1.80 M3/Min On Digital Display (Normal Operating Flow-1.3 M3/Min)Flow Control : Automatic Within 1% Of Set Value With Constant Flow Controller Irrespective Of Dust Load & Mains Voltage Variation.Volume Totalizer : Up To 99999.999 M3 ( Stp Corrected And Operating Conditions) On Digital Display. Temperature Measurement : Solid State Temperature Sensor For Stp Correctionadditional Features : Storage Of All Data Including Sampling Time, Volume, Minimum, Maximum & Average Flow / Constant Flow Volume / Non Constant Flow Volume & Their Respective Time Information In Hrs. & Min.Facility To Store Sampling Flow Data Value For Every 1 Minute In Memory For 24 Hrs.Usb & Usb Pen Drive Connectors Along With Usb Cable Provided For Transferring The Data To Pc With The Software Provided On Cd.Pc Software & Plotting Flow Data In Circular Chart Format Indicating Flow Variation Over 24 Hrs.Safety Features : Low Noise Imported Brush Type Lamb Blowerpower : Electronic Unit & Blower Motor 230 ±15%, 1 Ph, 50 Hz.Main Cabinet (Midi) : Size 37X30x66 Cm Weight-22Kg. , Ph Meter - 20 X 2 Line Back Lighted Lcd Display., Ph Meter Complies To Usp And Din Standards, Alphanumeric Splash Waterproof Polyester Keyboard With Soft Keys., Range 0° To 150° C. , Turbidity Meter - 0 - 10,000 Ntu , ± 2% Of Reading Plus 0.01 Ntu (0 To 1000 Ntu) ± 5% Of Reading (1000 To 4000 Ntu) ± 10% Of Reading (4000 To 10,000 Ntu) , Response Time: Less Than 6 Seconds, Sample Size: 30Ml, Operating Temperature: 0° - 50°C , Nessler Tube - Borosilicate Glass, 3.3Mm Thick, And 100Ml Capacity , Water Testing Kit - The Parameters Are Available In A Single Integrated Kit Called Master Kit For Drinking Water.Consisting Of1) Hardness2) Alkalinity3) Chlorides4) Iron5) Nitrates6) Fluorides7) Ph8) Turbidity• All Parameters Packed In A Compact Thermocol / Hip-Lined Carrycase For Convenient Field Use.• The Kit Comes With Instructions Manual Containing Easy Step-By-Step Testing Procedures.• The Kit Contains Everything Needed To Perform Rapid On-Site Analysis Of Drinking Water.• No. Of Tests Of Each Parameter: 100• Weight Of Master Kit: 3 Kgs. Approx. , Glass Test Tube - 125X75mm (Pack Of 100) Made Of Borosilicate , Laboratory Hot Air Oven - Features:As Compared To The Standard Model, Our Deluxe Model Is Fitted With A Microprocessor Digital Pid Temp. Indicator Cum Controller With Temp. Accuracy ±0.5°C.It Is Also Fitted With An Air Circulating Fan For Maintaining Equal Temp. Throughout The Chamber.Technical Parameterschamber Size (Mm)- 450 X 450 X 450 Mmchamber Size (Inches)- 18 X 18 X 18Capacity (Ltr.)- 95 Ltrs• Hot Air Ovens Are Widely Used In The Medical Industry To Sterilize Equipments And Other Materials That Are Used In A Laboratory.• Our Hot Air Oven Has A Standard Double Wall Fabrication, With The Inner Chamber Being Made Of Richly Anodized Aluminum Or A Highly Polished Stainless Steel Sheet.• The Exterior Wall Is Fabricated Out Of A Thick Sheet Of Mild Steel, Duly Finished With White Powder Coating.• The Gap Between The Walls Is Fitted With Special Grade Glass Wool.• The Apparatus Is Provided With Two Or Three Removable Shelves.• Kanthal Wire Heating Elements Are Provided On Three Sides To Attain Quick And Uniform Heating, In The Range Of 50°C To 180°C.• The Equipment Is Suitable For Working At 220V Ac 50 Hz Single Phase. , Digital Thermometer - Digital Display, Accuracy +/- 1C , Incubator - Specification: Designed For Both Heating And Cooling Options. It Is Generally Used For Incubation Where A High Degree Of Constant Temperature Accuracy Is Required.These Incubators Are Widely Used In The Pharmaceutical And Beverage Industries, In Waste Treatment Plants, In Research Laboratories And In The Agricultural Industry For The Routine Determination Of The Bio-Chemical Oxygen Demand (B.O.D.).The Inner Chamber Is Made Up Of Anodized Aluminum Or Stainless Steel.It Is Supplied With Two/Three Removable Perforated Shelves.The Exterior Is Made Up Of A Thick Sheet Of Mild Steel Duly Finished In Powder Coating.For Working At Lower Temperatures, A Cooling Unit Is Provided At The Lower Portion Of The Working Chamber, Whereas A Heating Arrangement Has Been Made In The Inner Chamber For Working At Higher Temperatures.The Temperature Varies From 5°C To 60°C, And Is Adjustable At Any Desired Point By A Dual Display Microprocessor Pid Digital Temperature Indicator Cum Controller With An Accuracy Of ± 0.5°C.An Air Circulation Fan Is Provided To Keep The Temperature Uniform Inside The Chamber.A Double Walled Door Is Provided With A Magnetic Gasket And A Lock & Key Arrangement.The Inner Door Is Made Out Of A Clear Acrylic Sheet Allowing The Inspection Of The Material In The Chamber, Without Disturbing The Chamber Temperature.Door Operated Inner Illumination Has Been Provided.The Incubator Works On 220 V Ac 50 Hz Single Phasechamber Size (Mm) Cap. (App.)455 X 410 X 610 112 L , Test Tube - 125X75mm (Pack Of 100) , Bod - Bottle300ml Bottle , Made Of Borosilicate , Chloroscope - Application: To Check The Residual Chlorine In Drinking Water From 0.25 P.P.M To 2.0 P.P.M.Standard Setup Consists Of:Chloroscope1 No.Square Unbreakable Test Tube2 Nosglass Dropper With Rubber Teat1 No.O-Toluidine Reagent 125 Mlpacked In Thermocol Box. , Size: 3 250Ml Made Of Borosilicate - Size: 3 250Ml Made Of Borosilicate , Size: 3 500Ml Made Of Borosilicate - 500Ml Made Of Borosilicate , Dia. 12.5 75Mm Made Of Borosilicate - 75Mm Made Of Borosilicate , Dia. 12.5 250Ml Made Of Borosilicate - 250Ml Made Of Borosilicate , Dia. 12.5 500Ml Made Of Borosilicate - 500Ml Made Of Borosilicate , Dia. 12.5 50 Ml Made Of Borosilicate - 50 Ml Made Of Borosilicate , Flocculator - Stirring Equipment For 6 Places Accommodates Beakers Up To 1000 Ml Tall Or 2000 Ml Short Shape, Stirring Speeds From 25 To 200 Rpm, Adjustable Timer Up To99 Minutes Or Continuous Operation, Flocculator/Jar Test Apparatus, Is A Flocculation (Jar) Tests On Water And Effluent Samples. A Digital Display Clearly Indicates The Speed Of The Rotational Stainless Steel Paddles, Which Can Be Varied From 25 To 250Rpm. The Digital Timer Can Be Set To Count Down From 1 To 99 Minutes. After Count Down, The Paddles Stop And An Alert Sounds. The Timer Then Counts Up In Minutes In Order To Measure Settling Time. Two Pre-Set Programs Allow Routine Speed And Time Parameters To Be Input And Then Selected By Simply Pressing One Button. Parameters Are Stored In The Memory And Can Be Recalled Or Altered At Any Time. The Intuitive Touch Sensitive Keypad Is Totally Flat For Easy Cleaning. It Is Supplied With Stainless Steel Paddles With Adjustable Spaces To Adjust The Depth Of The Paddles. Rpm Measurement Arrangement Is Provided. , Core Cutter - Field Density Kit Is: 2720 (Part Xxix)The Kit Consists Of:-I) Cylindrical Core Cutter 100 Mm Inner Dia X 130 Mm Long With Bevelled Cutting Edge And Having Wall Thickness Of 3 Mmii) Steel Dolley 100 Mm Inner Dia X 25 Mm High.Iii) Rammer With Steel Rod For Driving The Core Cutter , Pycnometer - Test Isperformed As Per Is:2720 (Part-Iii). Suitable For Determination Of Specific Gravity Of Sand And Fine Gravel.The Apparatus Consists Of A Glass Jar Of 1 Kg Capacity, Complete With Brass Cone, Rubber Seal And Screwed Cap. , Sand Pouring Cylinder Apparatus - The Apparatus Is Suitable For Field Density Estimation Of Fine And Medium Grained Soil, As Per Is: 2720 (Part Xxviii). It Consists Of:I)Sand Pouring Cylinder 115 Mm Internal Dia With Conical Funnel And Shutter.Ii)Calibrating Container, 100 Mm Inner Dia And 150 Mm Deep With Flange 50 Mm Wide.Iii) Metal Tray 300 Mm Square X 40 Mm Deep With A 100 Mm Dia Hole At The Centre. , Liquid Limit Device - The Apparatus Consists Of A Brass Cup, A Crank And Cam Mechanism, Mounted On A Rubber Base Of A Specified Hardness.A Brass Pin Having A Knurled End For Easy Removal Holds The Brass Cup.The Height Of Fall Of The Cup Can Be Adjusted By A Horizontal Lead Screw.Fitted With A F.H.P. Motor To Drive The Operating Mechanism Of Cup At 120 Rpm Ensuring Uniformity In Performing Test.Works On 220V, 50 Hz, Single Phase, And Is Supplied With Grooving Tool Type ‘A’And Gauge Block As Peris :9259, Is:2720 (Part-V). , Plastic Limit Set - Conforming To Is: 2720 (Part V) The Apparatus Consists Of :I) Glass Plate 200 Mm X 150 Mm X 3 Mm Thickii) Porcelain Evaporating Dishiii) Brass Rod 3 Mm Dia, 100 Mmlong.Iv) Flexible Spatula With 80 Mm Long, 20 Mm Wide Blade.V) Moisture Cans, 12 Nos. , Shrinkage Limit Set - The Apparatus Conforms To Is: 10077, And The Test Is Performed As Per Is: 2720(Part Vi). The Set Consists Of:-I) 75 Mm Square Prong Plate Made Of 3 Mm Thick Acrylic Sheet With Three Metal Prongs.Ii) 75 Mm Square Plain Plate Made Of 3 Mm Thick Acrylic Sheet.Iii) Stainless Steel Shrinkage Dish 45 Mm In Dia, 15 Mm Deep.Iv) Glass Cup With Ground Edge, 50 Mm To 55 Mm Dia, 25 Mm Deep.V) Flexible Spatula With 80 Mm Long, 20 Mm Wide Blade , Laboratory Permeability Apparatus (Constant Head And Falling Head) - Is:2720 (Part-17),Is11209suitable For Both Constant Head As Well As Falling Head Permeability Tests.The Apparatus Consists Of: -I) A Wooden Stand Fitted With Nine Glass Stand Pipes Of Diameter Ranging From 6 Mm To 75 Mm.A 75 Mm Dia Tube Is Fitted With An Overflow Pipe. A Rubber Bung With Brass Tube Is Provided For Constant Head. Tests.Ii)Permeability Mould 1000 Ml Capacity With Detachable Collar, 50 Mm High, One Base Plate, Metallic Perforated Swell Plate And A Solid False Bottom Plate For Compaction Of Soilsteel Over Head Tank, 400 Diameter X1000mm Heightwith One Inlet And Five Outlet Valves , Hydrometer Apparatus - Test Is Performed As Per Is:2720 (Part- Iv). Used For Particle Size Analysis Of Soil In Suspension When It Has More Than 10% Of 75 Micron Is Sieve Passing Material. The Scale On The Hydrometer Is Marked From 0.995 To 1.030 In Terms Of Density (G/Ml) Of Suspension At 27O C. , I.S. Sieves 20 Cm Diameter Brass Aperture Size 4.75 Mm, 2.36Mm, 1.18Mm, 600Micron, 300 Micron,150 Micron And 75 Micron As Per Is 460 - 200 Mm Dia, Spun Brass Framesize : 4.75Mm, 2.36Mm, 1.18Mm, 600Mic, 300Mic, 150Mic, 75Mic, Lid & Pan , C.B.R. Apparatus - As Per The Is Code 9669, Digital Load Frame With Lcd 50 Kn Capacity With Min 4 Speed 1.5, 1.25 2.5 Mm/Min And True Speed Control Upto 15Mm/Min • Two Pillar Type. • Horizontal Clearance-265Mm Min • Vertical Clearance-700Mm Min • Maximum Platen Dia-130Mm With Hardness Of Material(Platen): 60 Rhc. • Ram Dia 50Mm • The Lower Platen Moves Up And Down • A Dial Gauge Mounting Bracket Is Provided On One Of The Two Pillars. • Suitable For Operation On 220 V, 50 Hz, Single Phase,Ac Supply Paint Quality:-Powder Coating 70-80 Micron Thick Material Of Construction: Special Quality Low Carbon Mild Steel Mould - Ms150mm Id X 175 Mm H, Perforated Base Plate - Ms Extension Collar - Ms150 Mm Id X 50 Mm High Penetration Piston 50 Mm Face Dia Circular Metal Spacer Disc, With Detachable Handle, 148 Mm Dia X 47.7 Mm High, Annular Metal Weight 2.5 Kg, 147 Mm Dia With 53 Mm Dia Central Hole Slotted Metal Weight 2.5 Kg, 147 Mm Dia, With 53 Mm Dia Slot Rammer 2.6 Kg, 310 Mm Controlled Drop Rammer 4.9 Kg, 450 Mm Controlled Drop Proving Ring Capacity 50 Kn Dial Gauge 25 Mm Travel, 0.01 Mm Least Count. Load Frame Pillar Thread M30 X 600Mm. Suitable For Operation On 220 V, 50 Hz, Single Phase, Ac Supply. , Laboratory Vane Shear Apparatus - It Has Torque Head Is Electrically Driven By A Small Reduction Geared Motor With A Strain Rate Of 6O Per Minute Approximately. , Infra –Red Moisture Meter - Infrared Moisture Meter Is Fast Accurate, Operate On 220Volts Ac Supply. It Is Completely Automatic And Provides % Moisture Loss Through Entire Drying Cycle.Heating Arrangement Consist Of 250 Watts Heating Lamp With A Solid State Power Start To Control Rate Of Drying And Also Temperature.Range : 0-100%Min. Reading :0.2Sample Weight : 5-7 Gms. , Direct Shear Apparutus . Moterised With 12 Speed . As Per Is : 2720 ( Part Xiii ) - Motorised Microprocessor Based, Is:2720 (Part Xiii)Complete With Software But Without Computer And Printerthe Complete Outfit Consists Of The Following:-I)Shear Box Assembly, 60 Mm Square, Complete With Au-Bracket, Guide Pins And Spacingscrews, Made Of Brass.Ii)Gripper Assembly Consisting Of Two Plain Grid Plates, Two Perforated Grid Plates, One Base Plate And One Loading Pad, All Made Of Brass.Iii)Two Porous Stones 6 Mm Thick, Fitting The Shear Box.Iv)Shear Box Housing Of Brass, Complete With Two Roller Strips.V)Loading Unit With Normal Loading Capacity Of 8 Kg/Cm2 On 60 Mm Square Specimen With Motor Driven 12 Speed Gear Drive Providing Twelve Constant Rates Of Strain I.E. 1.25, 0.625, 0.25, 0.125, 0.05, 0.025, 0.01, 0.005, 0.002, 0.001, 0.0004, And 0.0002 Mm/Min.Vi)Specimen Cutter For A Specimen Size Of 60 Mm X 60 Mm X 25 Mm.Vii)Set Of Weights To Give A Normal Stress Upto 3 Kg/Cm2 On The Specimen Through Lever Comprising 4 Of 0.05 Kg/Cm2, 1 Of 0.1 Kg/Cm2 1 Of 0.2 Kg/Cm2 3 Of0.5 Kg/Cm2 And 1 Of 1.0 Kg/Cm2.Electronic Data Acquisition System For Direct Shear Test Equipmentthe Three-Channel Micro Controller Based Signal Conditioning And Touch Panel Display Unit Is Suitable To Measure Horizontal Load, Horizontal Displacement And Vertical Displacement During Direct Shear Testing. The Data Of All Three Channels Of Direct Shear Test Can Be Transferred To Computer Through Rs-232/ Ethernet And Can Be Online Monitored.The Unit Also Provides The Facility Of Online Monitoring With Touch Panel Is Provided To Perform Various Operations Such As Tare, Programming, Start, Stop Etc.Independent Taring Of Each Channelautomatic Data Saving On Stop Button.There Are 25 Set Results Having A Maximum Of 200 Data Points Per Set Can Be Stored In The Electronic Unit .The Sample Number Can Be Programmed.Online Date And Time Of Test Will Be Stored Along With The Data.On Line (While The Test Is In Progress) Data Transfer To The Computer Through Rs-232/ Ethernet. , Consolidation Apparatus - Sensors Specification: -Load Cell:Capacity : 200Kgtype : S-Shapedexcitation Voltage : 10Vdcnominal Output : 3.0Mv/Vnon-Linearity : < + 0.025% Fsohysteresis : < + 0.02% Fsonon-Repeatability : < + 0.01% Fsocreep (30 Minutes) : < + 0.03% Fsozero Balance : + 1.0% Fsoinput Resistance : 392 + 15 Ohmsoutput Resistance : 350 + 3 Ohmsinsulation Resistance : >1000 Mohmssafe Over Load : 150% Of Rated Capacityultimate Over Load: 250% Of Rated Capacitytemp. Range: 0O C To 60Oc.Temp. Effect On Output: <0.0015% Fso/ Octemp. Effect On Zero : <0.0020% Fso/ Oclinear Variable Differential Transformer (Lvdt) Stroke : ± 20Mmlinearity Deviation : ± 1% Of Rated Capacityrepeatability : ± 0.1% Of Rated Capacityhystresis : ± 0.5% Of Rated Capacityexcitation : 2-Volt Rms 2 Khz Sinusoidalsensitivity : 1 Mv/V/Mmsafe Temperature Range: 0O - 50O Ccore Fixture : Spring-Loaded Plungersoftware Specification Data Acquisition From Signal Conditioning Unit To Computeroff-Line Data Analysis Software That Does All The Calculations Of Direct Shear Test.Has Option For Manual As Well As Automatic Recording Of Data.Calculates Area, Volume, Bulk Density, Dry Density, Moisture Content Etc. Of The Specimendisplay The Following Plots (Graphical)(A) Horizontal Displacement Vs Shear Force(B) Horizontal Displacement Vs Vertical Displacement(C) Normal Stress Vs Shear Force(D) Maximum Value Of The Dilation Anglethe Software Is Windows Based And User Friendly. It Is Easy To Operate And Has The Flexibility To Enter Different Sizes Of Test Specimen Up To 1000Mm X 1000Mmnote- Computer Does Not Form Part Of The Supply.Three Gang Bench Type Consolidometer (Front Loading)Test Is Performed As Per Is: 2720 (Part-Xv). The Unit Comprises:Loading Unit 20 Kg/Cm2capacity- 3 No.Consolidation Cell60mm F X 20Mm Height - 3 No.Dial Gauge 5 X 0.002Mm- 3 No.Set Of Weights- 3 Sets(Stress – Up To 10Kg/Cm2) , Triaxial Shear Test Apparatus - Load Frame, Motorised, 50Kndesigned To Accommodate Universal Triaxial Cell For Testing Soil Specimens Up To 100 Mm In Diameter.Suitable For Operation On 220V, 50 Hz, Single Phase Supply.Triaxial Cell For 38/50Mm Diameter X 76/100Mm High Specimen Pneumatic Control Panel, 2 Lines. Air Compressors, 10 Kg/Sq.Cm. De-Airing System With Vacuum Arrangement It Has A Vacuum Regulator, 20 Ltr Water Chamber And Additional Line For Vaccum And Vacuum Gauge.Electronic Data Acquisition System The Four-Channel Micro Controller Based Signal Conditioning And Touch Panel Display Unit Is Suitable To Measure Axial Load, Pore/Back Pressure, Vertical Displacement And Volume Change (Optional) Directly Indicated In Their Respective Engineering Units During Triaxial Testing. Sensors Specification: -Load Cellcapacity : 1000Kgtype : S-Shapedexcitation Voltage : 10Vdcnominal Output : 3.0Mv/Vnon-Linearity : < + 0.025% Fso2.Pressure Transducercapacity : 2000Kpaexcitation Voltage : 12Vdcnominal Output : 4-20Maover Pressure Limit : 2 Times F.S.Burst Pressure : 3 Times F.S.3.Linear Variable Differential Transformer (Lvdt) Stroke : ± 20Mmlinearity Deviation : ± 1% Of Rated Capacityrepeatability : ± 0.1% Of Rated Capacitysoftware Specificationa) Data Acquisition From Signal Conditioning Unit To Computerb) Off-Line Tri-Axial Data Analysis Software That Does All The Calculations Of Uc, Uu, Cu, Cu Bar & Cd Triaxial Test.C)Has Option For Manual As Well As Automatic Recording Of Data.Accessories :Top Loading Pad, Perspex,38 Mm Dia. 1 No.Plain Perspex Disc 38Mm Diax 6 Mm Thick 1 Pair.Porous Stone 38Mm Diax6 Mm Thick. 1 Pair.Sheath Stretcher For 38 Mm Dia Specimen 1 No. Two Way Split Former For 38 Mm Dia Specimen 1 No. Rubber Sheath For 38 Mm Dia Specimen 12 Nos. Drainage Tube (Short), 38 Mm 4 Nos. Drainage Tube (Long), 38 Mm 4 Nos. “O’ Rings For 38Mm Dia Specimen 4 Nos. Split Mould, 38Mm Dia 1 No. Top Loading Pad 38Mm (Plain) 1 No. , Unconfined Compression Tester - Digital Load Frame With Lcd 50 Kn Capacity With 4 Speed Variations. Horizontal Clearance - 430 Mm Vertical Clearance - 950 Mm Maximum Platen Dia - 150 Mm Maximum Platen Travel - 100Mm Ram Dia - 50Mm Suitable For Operation On 220 V, 50 Hz, Single Phase, Ac Supply. Ring Capacity - 2 Kn Dial Gauge - 25 Mm, 0.01 Mm Least Count. Mould - 38 Mm Dia × 76 Mm Long Rubber Sheath - 38 Mm Dia Specimen , Proctor Test Apparatus For Light Compaction - Compaction Mouldcompaction Mould 100 Mminternal Dia X 127.3 Mm Height, 1000 Ml Volume Complete With Collar And Base Plate, All Made Of Mild Steel Tie Rods Of Mild Steel And Wing Nuts For Clamping.Compaction Rammer, Lightcompaction Rammer, Light, Made Of Mild Steel 2.6 Kg Weight, 50 Mm Dia Compaction Face, 310 Mm Controlled Free Vertical Fall. , Proctor Test Apparatus For Heavy Compaction - Compaction Mould Compaction Mould 150 Mminternal Dia X 127.3 Mm Height, 2250 Ml Volume Complete With Collar And Base Plate, All Made Of Mild Steel Tie Rods Of Mild Steel And Wing Nuts For Clamping.Compaction Rammer, Heavy Compaction Rammer, Heavy, Made Of Mild Steel 4.89 Kg Weigh, 50 Mm Dia Compacting Face, 450 Mm Controlled Free Vertical Fall. , Hot Air Oven - Digital Laboratory Oven (18X18x18), Hot Oven 450Mm Digital , Electronic Balance - Electronic Balance Upto 500G(Accuracy Capacity 0.01 Gm), And 5Kg (Accuracy 0.1Gm) , Sieve Shaker - Having A Sturdy Can Iron Body, The Sieve Shaker Has An Inclined Sieve Table Which Can Accommodate A Maximum Of Seven Sieves Of 150 Mm Or 200 Mm Diameter. To Hold The Sieves An Adjustable Top Clamping Plate Is Provided.The Table Has A Gyratory Motion In Addition To Tapping Action.The Operating Gear Assembly Is Enclosed In An Oil Bath Fitted With A Transparent Oil Level Indicator Window. Suitable For Operation On 220 V, 50 Hz, Single Phase Supply & Supplied With 30Cm Adaptor. , Density Bottle - 100Ml, 50Ml, Made Of Borosilicate , Sand Bath - Device With Tray, Stove, Palet, Knife, Steel Top With Powder Coated, 230V, Single Phase , Non Corridible Air Tight Container Or Can - 100Ml, 200Ml, 500Ml, 1000Ml, , Metre Scale - 300Mm Length, Steel Made , Thermometer - 0.5C-60C , Water Bath - 15L Capacity, Temperature Controlled, Led Water Bath , Glass Measuring Cyliner - 1000Ml , Stopwatch - Accuracy: 0.001 Seconds , Ordinary Or Non-Recording Rain Gauge - Non Recording Rain Gauge Should Be Manufactured From Non-Corrosive Fiberglass Reinforced Plastic As Per Is: 5225: 1969. Must Consists Of Collector Assembled With Gunmetaling, Funnel, Locking Rings And Base. , Self-Recording Rain Gauge - Rain Gauge Shold Be As Per Is 5235: 1969 And Made From Reinforced Fiberglass Plastic. Container Is Assembled With Gunmetal Ring And Locking Arrangements. Siphoning System And Recording Arrangements Are Manufactured From Pvc. The High Torque Quartz Clock Of Min 25 Hours Revolution. Must Suppy 100-Charts, Pen, 15 Cc Ink , Open Evaporation Pan - The Pan Shuold Be Manufactured From G I Sheet As Per Is: 5973: 1998, Duly Tinned And Epoxy Pointed, And Tested For No Water Leakage. , Wind Vane - Manufactured As Per Is: 5799: 1970 , Anemometer Cup Counter - Manufactured As Per Is: 5912: 1970 , Stevenson Screen - Manufactured From Best Quality Indian Seasoned Wood And Accurately Assembled With Side Louvers As Per Is: 5948:1970 And Are Suitable For Housing Dry Bulb, Wet Bulb, Maximum And Minimum Temperature Thermometer. , Set Of Thermometers - Set Of Thermometers Which Will Be Used For Measurement Of Maximum, Minimum Air Temperature And Relative Humidity , Double Ring Infiltrometer - Infiltrometer Rings Made From Min.14 Gauge Ms Sheet Rolled And Butt-Welded. Hammering End Reinforced With ½” Iron Strip And Other End Sharpened For Smooth Entry In To Soil. Complete With One Inner Ring 30-Cm Dia.; One Outer Ring 45 Cm Dia. Min. Height Of Rings 30-Cm; Must Supply Additionally: Driving Plate With Hammer; Float, Guide Rod, Pointer Gauge & Stop Watch. , Pigmy Cup Type Current Meter - It Should Be Suitable To Measure The Water Velocities Up To 1.5 M/Sec. It Has To Meet The Requirements Of Is: 3910 And Supplied Duly Calibrated From Govt. Research Institute. , Cup Type Current Meter - It Should Be Suitable To Measure The Water Velocities Up To 2.5 M/Sec. It Has To Meet The Requirements Of Is: 3910 And Supplied Duly Calibrated From Govt. Research Institute. Accessories Required: 10 Kg Fish Weight, 10 M Suspension Cable And Other Accessories. , Automatic Weather Station - Microclimate Monitoring System With 3.5Mm Stereo Plug, 5M Cablesolar Radiation:Range: 0 To 1750 W/M2resolution: 1 W/M2accuracy: ± 5% Of Measurement Typicalprecipitation:Range: 0 To 400 Mm/Hresolution: 0.017 Mmaccuracy: ± 5% Of Measurement From 0 To 50 Mm/Hvapor Pressure:Range: 0 To 47 Kparesolution: 0.01 Kparelative Humidityrange: 0 To 100% Rh (0.00-1.00)Resolution: 0.1% Rhair Temperature: Range: -50 To 60 °Cresolution: 0.1 °Caccuracy: ± 0.6 °Chumidity Sensor Temperature:Range: -40 To 50 °Cresolution: 0.1 °Caccuracy: ± 1.0 °Cbarometric Pressurerange: 50 To 110 Kparesolution: 0.01 Kpaaccuracy: ± 0.1 Kpa From -10 To 50 °C, ± 0.5 Kpa From -40 To 60 °Chorizontal Wind Speedrange: 0 To 30 M/Sresolution: 0.01 M/Saccuracy: The Greater Of 0.3 M/S Or 3% Of Measurementwind Gustrange: 0 To 30 M/Sresolution: 0.01 M/Saccuracy: The Greater Of 0.3 M/S Or 3% Of Measurementwind Direction: Range: 0° To 359°Resolution: 1°Accuracy: ± 5°Tilt:Range: -90° To +90°Resolution: 0.1°Accuracy: ± 1°Lightning Strike Count:Range: 0 To 65,535 Strikesresolution: 1 Strikeaccuracy: Variable With Distance, >25% Detection At <10Km Typicalrange: 0 To 40 Kmresolution: 3 Kmaccuracy: Variablethere Should Be No Moving Parts. Communication: Sdi-12 Communicationdimension:Diameter: 10 Cmheight: 34 Cm, Includes Rain Gauge Filtercable Length : 5 Meterdata Logger With User-Supplied Simdata Logger: 5 Min To 12 Htimekeeping: Synchronize Automatically And On-Demand; Gps, Cellular, Or Utility Softwarecomputer Communication : Standard Usb Cable, Usb A To Micro-Usbinternet Downloads: Ssl/Tls Encryptedmobile Communication Bluetooth 5.2 Supporting Bluetoothgps Communication: Type: Integrated 56-Channel Gps/Qzss Receiverupdate: Daily (Automatic) And On-Demand (Manual)Accuracy: ±3 M, With Good Sky Viewenclosure Rating: Ip56, Nema 3Rsensor Input Ports:6Data Storage: 8 Mbcompliance: Iso 9001:2015, Em Iso/Iec 17050:2010 (Ce Mark) Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
INR 100000.0 /-
Tender Value
Refer document

BOQ Items

Sl. No. Item TitleItem Description
1Digital Magnetic Stirrer with Hot PlateCapacity-2Ltr Number of stirring Positions: 1 Type of Drive Motor:DC Motor Display Option/Output Read out Option: Digital Magnetic stirrer is: with a hot plate or some other means for heating the liquid Controller type: Electronically controlled and Programmable Speed Control Accuracy of set speed (+/-) (RPM): 2-3% Maximum Stirring capacity per position: 2000 millilitre Stainless Steel Top Plate Material, Digital Front Panel, Last run memory CE certified Product (seller to furnish supporting document to Buyer on demand) SPEED Speed Mode: Variable Speed Minimum Speed Possible (RPM): 50 Maximum Speed (RPM) of variable speed mode equipment: 1600 DIMENSIONS External Dimension: (Height) 200 millimetre External Dimension: Width 200 millimetre External Dimension: Depth: 50 millimetre Body Material: Stainless Steel Finish of Body material: Powder coated Top plate Finish:Stainless Steel STIR BAR Stir bar cover material: PTFE QUOTED Stir Bar length: 200 millimetre TOP PLATE Top plate area shape:Square Square Top plate diameter:100mm Top plate Finish:Stainless Steel
2AUTOMATIC WATER DISTILLATION EQUIPMENT DOUBLE STAGEElectrical requirements 230 Volts 10 / 50 Hz Single phase Distillation water capacity (ltr/hr): 4 ltr/hr Numbers of Built in Quartz heaters (nos): 2 Distillation units Type: horizontal Built in Quartz heater capacity (KW): 7 Double stage glass(quartz) distillation units: yes Cooling Water consumption (ltr/hr):120 ltr/hr Replaceable Silica Heater: The horizontal quartz jacket is fitted with removable silica heater & screw threaded connectors for ease of cleaning. Distillate temperature is approx. b/w 25° to 45° C which is ensured by an efficient condenser. The stand is powder coated for rust free operation & lustrous appearance. Cooling water from the condenser is re-circulated into the boiling chamber, hence saving energy. Fuse is provided for safety in case of voltage fluctuation or short circuit. Boiler is provided with Replaceable Constant Level Device for easy draining & cleaning of boiling chamber. Additional In- Built Safety Features Gate Valve: Conserves Cooling water wastage in case of power failure. Flow Switch: In-built safety feature for the equipment unit shut off in case of cooling water failure. Temperature Switch: The boiler is equipped with a safety temperature switch which shuts off the unit if water level in the boiler falls below the heater, thus saving the glass parts from any damages.
3Digital Electronic BalanceType of Electronic Weighing Machine: Electronic Precision Pan Balance Rated Load/ Capacity(kg): 220 gm Resolution(gms): 1 mg Class type Class-I Display: led Number of Display: single Speed of measurement: 4 second Number of scale division: 1000 Tare provision: Manual Power Requirement mains operated battery operated Power Supply: Single Phase DC Operating voltage in Volts: 6 Volt Battery Backup: Yes Backup time(hour): 10 Battery type: Non-rechargeable Battery rating: AAA1.5v Type of Sensing Element: Load Cell Number of load cell/EMFC: 1 Class of Protection: IP 65
4Jar Test Apparatus FlocculatorFlocculator (Jar Test Apparatus) is an equipment designed for testing water soluble polymers used with conventional waste water treatment processes such as : • Coagulation • Flocculation • Sedimentation in water • Waste water treatment • Other industrial applications. It provides identical test conditions for all samples. In this instrument Stirring shaft for any jar can be removed without disturbing other stirrers. Illuminator base made of acrylic sheet provides diffused cold light through floc. Samples. FEATURES: • Microprocessor Based Controls • Programmable Mode • Programmable RPM cum TIMER Mode • White Light Illumination • On Board Power On/Off • Soft Touch Keypad and Brilliant 16 X 2 a-numeric LCD Paddles Made up of Stainless Steel • Confirms To Standards TECHNICAL DETAILS: Ø Rotation Speed : 5-150 RPM (+1 RPM) Ø Timer : 99:59:59 (HH:MM:SS) Ø Display : 16 x 2 a-Numeric LCD Ø Keypad : Soft Touch Ø No. of Paddles : 6 Ø Drive System : Stepper Mode Ø Illumination : White Light Ø Power : 220/230 VAC, 50Hz
5Fluoride Ion Meter (with Fluoride electrode)pH Range & Accuracy: -2.000 - 20.000pH & ±0.002pH Resolution: 0.001,0.01,0.1pH ( Selectable ) Ion Concentration Range: 0.001-19999 ppm,mg/L,mol/L (Selectable Depending on meas. Range of Ion Selective Electrode) Ion Concentration Accuracy: ±0.5% Full Scale ( Monovalent),±1% Full Scale (Divalent) mV Range & mV Accuracy: -.11999.9 mV & ±0.2mV Resolution: 0.1/1mV, Selectable Temperature Range & Accuracy: 0-105°C, 32-221°F & ±0.5°C,±0.9T Calibration Points: Ion / pH : Up to 5 Points pH Buffer Groups: USA (011.68,4.01,7.00,10.01 ,12A5), NIST (pH1.68,4.01,6.86,9.18,12.45), DIN (011.09,4.65,6.79,923,12.7 OR User Define) Memory and Output:500 data sets with Date/Time stamping, USB Communication interface. Connector & Hold Function: BNC & Selectable Temperature Compensation: 0-100t,32-212 F,Automatic or Manual Stability Conditions: Low or High, Selectable Calibration due reminder: 1 to 31 days or Off Power Supply: DC 5V adapters, using AC 220V / 50Hz, Dimensions LxWxH (mm) & Weight: 210 x 188 x 60 & 1.2kg
6DOUBLE BEAM UV-VIS SPECTROPHOTOMETERTYPE: Type of Spectrophotometer: UV - VISIBLE Type of Optical System: Double Beam Monochromator Type: Holographic Grating Detector Type: Photodiode Spectral Bandwidth Type: Fixed Bandwidth LIGHT SOURCE Light Source: Deuterium Lamp Diffraction Grating (lines/mm):1400 Switching of Light Source: Automatic Wavelength Setting and Scanning: Automatic OPTICAL PERFORMANCE Source Wavelength –Minimum: 190 nanometer Source Wavelength –Maximum: 1100 nanometer Resolution: 0.3 nanometer Wavelength Accuracy (+/-): 0.5 nanometer Bandwidth (nm): 0.1 Scanning Speed(nm/min): 300 Focal length (mm): 100 to 149 Photometric measurement modes: Transmittance, Absorbance, Concentration (Wavelength, time) Photometric Absorbance(Max) (Abs) (+/-): 3 Photometric Absorbance Accuracy (Max) (+/-): 0.005 Photometric Transmittance (Max) (+/-): 100 percent Photometric Transmittance Accuracy (Max) (+/-): 0.1 percent Photometric Reflectance (Max) (+/-): 0 percent Photometric Reflectance Accuracy (Max) (+/-): 0.005 percent Baseline Correction: Automatic GENERIC Display: In-built display Display type: LCD with Backlight Display Size: 4 inch Test result printing: Through external printer Connectivity: RS 232 Sample switching/selection: Manual Capacity of Sample holder / Sample Carousel: 6 Maximum Path Length of sample: 100 millimeter Number of Cuvettes supplied-inclusive in the scope of supply: 10 Power Supply: 230 V ± 10, 50 Hz List of Items and Quantity of each item included in the offer: 2 NO of 10MM GLASS CUVETTES OPERATING CONDITIONS Minimum Operating Temperature: 10 degrees Celsius Maximum Operating Temperature: 40 degrees Celsius Operating Humidity (RH) (%) at 40-degree C: 80 percent
7Micropipette Single Channel Autoclavablea) 0.5ml to 10ml b) 500 ml to 5000ml
8Rotary ShakerShakers have Brush less DC (BLDC) Motor having a wide speed range from 50 to 400 rpm. A universal platform is with adjustable rollers and is also suitable to accommodate interchangeable clamps of assorted sizes / capacities for holding conical flasks, making the unit truly versatile in performance. Speed Range- 50 to 400 rpm Platform Size- 12 x 12 inches Flasks Capacity (max)- 5 x 500 ml Overall Dimensions W x D x H- 320 x 415 x 130 mm Speed Indicator- Digital Digital Count down Timer- 99 minutes Shaking Orbit- 10 mm Supply: 220-240 Volts, 50 Hz Single Phase. A variety of clamps are available having capacity of 500 ml, 250 ml, 150 ml and 100/ 50 ml (5 no’s each)
9Prestaltic pumpFlow range – 0.1ml/hr to 1000ml/hr Accuracy – ±2% Digital display of functions and time Auto-stop with audible alarm Battery back-up stores memory in case of power failure.
10Dissolved Oxygen MeterMeasurement & Range: Dissolved Oxygen - 0 to 20.0 mg/L. Display: 13 mm ( 0.5" ) LCD, 3 1/2 digits. Accuracy: ± 0.4 mg/L. (after calibration within 23± 5 ?) Resolution: 0.1 mg/L Power Supply: 006P DC 9V battery (Heavy duty type).
11High Volume Air SamplerBlower Flow Rate : More than 1.6 m3 / min free flow without resistance.Particulate Sampling : Less than 2.5µ (PM-2.5) using PM2.5 Size Selective Inlet at 1.13M3/Min (40CFM) (Std) Filter Holder : SS 304 to accommodate filter paper of Size :25 x 20 cm. Filter Media : Whatman GF/A or EPM – 2000 or QM-A Size : 254 x 203 mm Electronic Control Module ECM with Constant Flow Controller & digital display of STP corrected Flow & Volume Display : 16 x 2 Character Alphanumeric LCD Module with blue backlit Keys : 6 Nos. Delay Time : Programmable with Real Time Clock Sampling Time : Programmable upto 199 hrs. 59 mts. with Real Time Clock Electronic Time Totalizer : Up to 199 hrs. 59 mts. Automatic Sampling Control : Fully programmable electronic timer to automatically shut off system after preset time interval. Flow Measurement : With exhaust orifice & pressure sensor Flow Setting & Display : Range 0.60 to 1.80 M3/min on Digital Display (Normal operating Flow-1.3 M3/min) Flow Control : Automatic within 1% of set Value with Constant Flow Controller irrespective of dust load & mains voltage variation. Volume Totalizer : Up to 99999.999 M3 ( STP Corrected and operating conditions) on digital display. Temperature Measurement : Solid State Temperature Sensor for STP correction Additional Features : Storage of all data including sampling time, volume, minimum, maximum & average flow / Constant Flow Volume / Non Constant Flow Volume & their respective time information in Hrs. & Min. Facility to store sampling flow data value for every 1 minute in memory for 24 Hrs. USB & USB Pen Drive connectors along with USB Cable provided for transferring the data to PC with the software provided on CD. PC Software & plotting flow data in circular chart format indicating flow variation over 24 Hrs. Safety Features : Low Noise imported Brush type Lamb Blower Power : Electronic Unit & Blower Motor 230 ±15%, 1 Ph, 50 Hz. Main Cabinet (Midi) : Size 37x30x66 cm Weight-22Kg.
12pH meter20 x 2 line back lighted LCD display., pH Meter complies to USP and DIN standards, alphanumeric splash waterproof polyester keyboard with soft keys., Range 0° to 150° C.
13Turbidity meter0 - 10,000 NTU , ± 2% of reading plus 0.01 NTU (0 to 1000 NTU) ± 5% of reading (1000 to 4000 NTU) ± 10% of reading (4000 to 10,000 NTU) , Response Time: less than 6 seconds, Sample Size: 30ml, Operating Temperature: 0° - 50°C
14Nessler TubeBorosilicate glass, 3.3mm thick, and 100ml capacity
15Water testing kitThe parameters are available in a single integrated Kit called Master Kit for Drinking Water. Consisting of 1) Hardness 2) Alkalinity 3) Chlorides 4) Iron 5) Nitrates 6) Fluorides 7) pH 8) Turbidity • All parameters packed in a compact thermocol / HIP-lined carrycase for convenient field use. • The Kit comes with Instructions manual containing easy step-by-step testing procedures. • The Kit contains everything needed to perform rapid on-site analysis of Drinking water. • No. of tests of each parameter: 100 • Weight of Master Kit: 3 Kgs. approx.
16Glass test tube125X75mm (Pack of 100) made of Borosilicate
17Laboratory hot air ovenFEATURES: As compared to the standard model, our deluxe model is fitted with a microprocessor digital PID temp. indicator cum controller with temp. accuracy ±0.5°C. It is also fitted with an air circulating fan for maintaining equal temp. throughout the chamber. TECHNICAL PARAMETERS Chamber Size (mm)- 450 x 450 x 450 mm Chamber Size (Inches)- 18" x 18" x 18" Capacity (Ltr.)- 95 Ltrs • Hot air ovens are widely used in the medical industry to sterilize equipments and other materials that are used in a laboratory. • Our hot air oven has a standard double wall fabrication, with the inner chamber being made of richly anodized aluminum or a highly polished stainless steel sheet. • The exterior wall is fabricated out of a thick sheet of mild steel, duly finished with white powder coating. • The gap between the walls is fitted with special grade glass wool. • The apparatus is provided with two or three removable shelves. • Kanthal wire heating elements are provided on three sides to attain quick and uniform heating, in the range of 50°C to 180°C. • The equipment is suitable for working at 220V AC 50 Hz single phase.
18Digital ThermometerDigital display, accuracy +/- 1"c
19IncubatorSpecification: Designed for both heating and cooling options. It is generally used for incubation where a high degree of constant temperature accuracy is required. These incubators are widely used in the pharmaceutical and beverage industries, in waste treatment plants, in research laboratories and in the agricultural industry for the routine determination of the Bio-chemical oxygen demand (B.O.D.). The inner chamber is made up of anodized aluminum or stainless steel. It is supplied with two/three removable perforated shelves. The exterior is made up of a thick sheet of mild steel duly finished in powder coating. For working at lower temperatures, a cooling unit is provided at the lower portion of the working chamber, whereas a heating arrangement has been made in the inner chamber for working at higher temperatures. The temperature varies from 5°C to 60°C, and is adjustable at any desired point by a Dual Display Microprocessor PID Digital Temperature Indicator cum Controller with an accuracy of ± 0.5°C. An air circulation fan is provided to keep the temperature uniform inside the chamber. A double walled door is provided with a magnetic gasket and a lock & key arrangement. The inner door is made out of a clear acrylic sheet allowing the inspection of the material in the chamber, without disturbing the chamber temperature. Door operated inner illumination has been provided. The Incubator works on 220 V AC 50 Hz single phase Chamber Size (mm) Cap. (App.) 455 x 410 x 610 112 L
20test tube125X75mm (Pack of 100)
21BODBottle300ml bottle , made of borosilicate
22ChloroscopeApplication: To check the residual chlorine in drinking water from 0.25 p.p.m to 2.0 p.p.m. Standard Setup consists of: Chloroscope1 No. Square unbreakable test tube2 Nos Glass Dropper with rubber teat1 No. O-Toluidine reagent 125 ml Packed in thermocol box.
23Size: 3" 250ml made of BorosilicateSize: 3" 250ml made of Borosilicate
24Size: 3" 500ml made of Borosilicate500ml made of Borosilicate
25Dia. 12.5" 75mm made of Borosilicate75mm made of Borosilicate
26Dia. 12.5" 250ml made of Borosilicate250ml made of Borosilicate
27Dia. 12.5" 500ml made of Borosilicate500ml made of Borosilicate
28Dia. 12.5" 50 ml made of Borosilicate50 ml made of Borosilicate
29FlocculatorStirring equipment for 6 places accommodates beakers up to 1000 mL tall or 2000 mL short shape, Stirring speeds from 25 to 200 rpm, Adjustable timer up to99 minutes or continuous operation, Flocculator/Jar Test Apparatus, is a flocculation (jar) tests on water and effluent samples. A digital display clearly indicates the speed of the rotational stainless steel paddles, which can be varied from 25 to 250rpm. The digital timer can be set to count down from 1 to 99 minutes. After count down, the paddles stop and an alert sounds. The timer then counts up in minutes in order to measure settling time. Two pre-set programs allow routine speed and time parameters to be input and then selected by simply pressing one button. Parameters are stored in the memory and can be recalled or altered at any time. The intuitive touch sensitive keypad is totally flat for easy cleaning. It is supplied with stainless steel paddles with adjustable spaces to adjust the depth of the paddles. RPM measurement arrangement is provided.
30Core CutterField Density Kit IS: 2720 (Part XXIX) The kit consists of:- i) Cylindrical core cutter 100 mm inner dia x 130 mm long with bevelled cutting edge and having wall thickness of 3 mm ii) Steel dolley 100 mm inner dia x 25 mm high. iii) Rammer with steel rod for driving the core cutter
31PycnometerTest isperformed as per IS:2720 (Part-III). Suitable for determination of specific gravity of sand and fine gravel. The apparatus consists of a glass jar of 1 kg capacity, complete with brass cone, rubber seal and screwed cap.
32Sand Pouring Cylinder ApparatusThe apparatus is suitable for field density estimation of fine and medium grained soil, as per IS: 2720 (Part XXVIII). It consists of: i)Sand Pouring Cylinder 115 mm internal dia with conical funnel and shutter. ii)Calibrating Container, 100 mm inner dia and 150 mm deep with flange 50 mm wide. iii) Metal tray 300 mm square x 40 mm deep with a 100 mm dia hole at the centre.
33Liquid Limit DeviceThe apparatus consists of a brass cup, a crank and cam mechanism, mounted on a rubber base of a specified hardness.A brass pin having a knurled end for easy removal holds the brass cup.The height of fall of the cup can be adjusted by a horizontal lead screw. Fitted with a F.H.P. motor to drive the operating mechanism of cup at 120 rpm ensuring uniformity in performing test.Works on 220V, 50 Hz, single Phase, and is supplied with Grooving Tool Type ‘A’ and gauge block as perIS :9259, IS:2720 (Part-V).
34Plastic Limit SetConforming to IS: 2720 (Part V) The apparatus consists of : i) Glass plate 200 mm x 150 mm x 3 mm thick ii) Porcelain evaporating dish iii) Brass rod 3 mm dia, 100 mmlong. iv) Flexible spatula with 80 mm long, 20 mm wide blade. v) Moisture Cans, 12 Nos.
35Shrinkage Limit SetThe apparatus conforms to IS: 10077, and the test is performed as per IS: 2720(Part VI). The set consists of:- i) 75 mm square Prong Plate made of 3 mm thick acrylic sheet with three metal prongs. ii) 75 mm square Plain Plate made of 3 mm thick acrylic sheet. iii) Stainless Steel Shrinkage Dish 45 mm in dia, 15 mm deep. iv) Glass cup with ground edge, 50 mm to 55 mm dia, 25 mm deep. v) Flexible Spatula with 80 mm long, 20 mm wide blade
36Laboratory Permeability Apparatus (Constant head and falling head)IS:2720 (Part-17),IS11209 Suitable for both constant head as well as falling head permeability tests.The apparatus consists of: - i) A wooden stand fitted with nine glass stand pipes of diameter ranging from 6 mm to 75 mm.A 75 mm dia tube is fitted with an overflow pipe. A rubber bung with brass tube is provided for constant head. tests. ii)Permeability mould 1000 ml capacity with detachable collar, 50 mm high, one base plate, metallic perforated swell plate and a solid false bottom plate for compaction of soil Steel over head tank, 400 diameter x1000mm height With one inlet and five outlet valves
37Hydrometer ApparatusTest is performed as per IS:2720 (Part- IV). Used for particle size analysis of soil in suspension when it has more than 10% of 75 micron IS sieve passing material. The scale on the hydrometer is marked from 0.995 to 1.030 in terms of density (g/ml) of suspension at 27o C.
38I.S. Sieves 20 cm diameter brass Aperture size 4.75 mm, 2.36mm, 1.18mm, 600micron, 300 micron,150 micron and 75 micron as per IS 460200 mm dia, Spun Brass Frame Size : 4.75mm, 2.36mm, 1.18mm, 600mic, 300mic, 150mic, 75mic, Lid & Pan
39C.B.R. ApparatusAs per the IS Code 9669, Digital Load Frame with LCD 50 kN Capacity with min 4 Speed 1.5, 1.25 2.5 mm/min and true speed control upto 15mm/min • Two pillar type. • Horizontal Clearance-265mm min • Vertical clearance-700mm min • Maximum Platen dia-130mm with Hardness of material(platen): 60 RHC. • Ram Dia 50mm • The lower platen moves up and down • A dial gauge mounting bracket is provided on one of the two pillars. • Suitable for operation on 220 V, 50 Hz, single phase,AC supply Paint quality:-Powder coating 70-80 micron thick Material of Construction: Special quality low carbon mild steel Mould - MS150mm ID x 175 mm H, Perforated Base Plate - MS Extension Collar - MS150 mm ID x 50 mm high Penetration Piston 50 mm face dia Circular Metal Spacer Disc, with detachable handle, 148 mm dia x 47.7 mm high, Annular Metal Weight 2.5 kg, 147 mm dia with 53 mm dia central hole Slotted Metal Weight 2.5 kg, 147 mm dia, with 53 mm dia slot Rammer 2.6 kg, 310 mm controlled drop Rammer 4.9 kg, 450 mm controlled drop Proving Ring Capacity 50 kN Dial Gauge 25 mm travel, 0.01 mm least count. Load frame pillar thread M30 X 600mm. Suitable for operation on 220 V, 50 Hz, single phase, AC supply.
40Laboratory Vane Shear ApparatusIt has torque head is electrically driven by a small reduction geared motor with a strain rate of 6o per minute approximately.
41Infra –Red Moisture MeterInfrared Moisture Meter is fast accurate, operate on 220Volts AC supply. It is completely automatic and provides % moisture loss through entire drying cycle. Heating arrangement consist of 250 watts heating lamp with a solid state power start to control rate of drying and also temperature. Range : 0-100% Min. Reading :0.2 Sample Weight : 5-7 Gms.
42Direct shear apparutus . moterised with 12 speed . As per IS : 2720 ( part XIII )Motorised Microprocessor Based, IS:2720 (Part XIII) complete with software but without computer and printer The complete outfit consists of the following:- i)Shear box assembly, 60 mm square, complete with aU-bracket, guide pins and spacingscrews, made of brass. ii)Gripper assembly consisting of two plain grid plates, two perforated grid plates, one base plate and one loading pad, all made of brass. iii)Two porous stones 6 mm thick, fitting the shear box. iv)Shear box housing of brass, complete with two roller strips. v)Loading Unit with normal loading capacity of 8 kg/cm2 on 60 mm square specimen with motor driven 12 speed gear drive providing twelve constant rates of strain i.e. 1.25, 0.625, 0.25, 0.125, 0.05, 0.025, 0.01, 0.005, 0.002, 0.001, 0.0004, and 0.0002 mm/min. vi)Specimen cutter for a specimen size of 60 mm x 60 mm x 25 mm. vii)Set of weights to give a normal stress upto 3 kg/cm2 on the specimen through lever comprising 4 of 0.05 kg/cm2, 1 of 0.1 kg/cm2 1 of 0.2 kg/cm2 3 of0.5 kg/cm2 and 1 of 1.0 kg/cm2. ELECTRONIC DATA ACQUISITION SYSTEM FOR DIRECT SHEAR TEST EQUIPMENT The three-channel micro controller based signal conditioning and touch panel display unit is suitable to measure Horizontal load, Horizontal Displacement and Vertical displacement during Direct Shear Testing. The data of all three channels of Direct Shear Test can be transferred to computer through RS-232/ Ethernet and can be online monitored. The Unit also provides the facility of online monitoring with Touch panel is provided to perform various operations such as TARE, PROGRAMMING, START, STOP etc. Independent Taring of each channel Automatic data saving on stop button. There are 25 set results having a maximum of 200 data points per set can be stored in the electronic unit .The sample number can be programmed. Online date and time of test will be stored along with the data. On line (while the test is in progress) data transfer to the computer through RS-232/ Ethernet.
43Consolidation apparatusSensors Specification: - Load Cell: Capacity : 200kg Type : S-shaped Excitation Voltage : 10VDC Nominal Output : 3.0mV/V Non-Linearity : < + 0.025% FSO Hysteresis : < + 0.02% FSO Non-Repeatability : < + 0.01% FSO Creep (30 Minutes) : < + 0.03% FSO Zero Balance : + 1.0% FSO Input Resistance : 392 + 15 Ohms Output Resistance : 350 + 3 Ohms Insulation Resistance : >1000 MOhms Safe Over Load : 150% of rated capacity Ultimate Over Load: 250% of rated capacity Temp. Range: 0o C to 60oC. Temp. Effect on output: <0.0015% FSO/ oC Temp. Effect on zero : <0.0020% FSO/ oC LINEAR VARIABLE DIFFERENTIAL TRANSFORMER (LVDT) Stroke : ± 20mm Linearity Deviation : ± 1% of rated capacity Repeatability : ± 0.1% of rated capacity Hystresis : ± 0.5% of rated capacity Excitation : 2-volt rms 2 KHz sinusoidal Sensitivity : 1 mV/V/mm Safe Temperature Range: 0o - 50o C Core Fixture : Spring-loaded plunger Software Specification Data Acquisition from Signal Conditioning Unit to Computer Off-Line Data Analysis Software that does all the calculations of Direct Shear Test. Has option for manual as well as automatic recording of data. Calculates Area, Volume, Bulk density, Dry density, Moisture content etc. of the specimen Display the following Plots (Graphical) (a) Horizontal Displacement vs Shear Force (b) Horizontal Displacement vs Vertical Displacement (c) Normal stress vs Shear Force (d) Maximum value of the Dilation Angle The software is windows based and user friendly. It is easy to operate and has the flexibility to enter different sizes of test specimen up to 1000mm X 1000mm Note- Computer does not form part of the supply. Three Gang Bench Type Consolidometer (Front loading) Test is performed as per IS: 2720 (Part-XV). The unit comprises: Loading Unit 20 kg/cm2capacity- 3 No. Consolidation cell 60mm f x 20mm height - 3 No. Dial gauge 5 x 0.002mm- 3 No. Set of Weights- 3 Sets (Stress – up to 10kg/cm2)
44Triaxial shear test apparatusLoad Frame, Motorised, 50kN Designed to accommodate Universal Triaxial Cell for testing soil specimens up to 100 mm in diameter.Suitable for operation on 220V, 50 Hz, Single phase supply. Triaxial Cell for 38/50mm diameter x 76/100mm high specimen Pneumatic Control Panel, 2 lines. AIR COMPRESSORS, 10 Kg/sq.cm. De-Airing system with vacuum Arrangement It has a vacuum regulator, 20 ltr water chamber and additional line for vaccum and vacuum gauge. Electronic Data Acquisition system The four-channel micro controller based signal conditioning and touch panel display unit is suitable to measure Axial load, Pore/Back pressure, Vertical displacement and Volume change (optional) directly indicated in their respective engineering units during Triaxial Testing. Sensors Specification: - LOAD CELL Capacity : 1000kg Type : S-shaped Excitation Voltage : 10VDC Nominal Output : 3.0mV/V Non-Linearity : < + 0.025% FSO 2.PRESSURE TRANSDUCER Capacity : 2000kPa Excitation Voltage : 12VDC Nominal Output : 4-20mA Over Pressure Limit : 2 times F.S. Burst Pressure : 3 times F.S. 3.LINEAR VARIABLE DIFFERENTIAL TRANSFORMER (LVDT) Stroke : ± 20mm Linearity Deviation : ± 1% of rated capacity Repeatability : ± 0.1% of rated capacity Software Specification a) Data acquisition from Signal Conditioning Unit to Computer b) Off-Line Tri-axial Data Analysis Software that does all the calculations of UC, UU, CU, CU bar & CD Triaxial Test. c)Has option for manual as well as automatic recording of data. Accessories : Top loading pad, Perspex,38 mm dia. 1 No. Plain Perspex disc 38mm diax 6 mm thick 1 pair. Porous Stone 38mm diax6 mm thick. 1 pair. Sheath stretcher for 38 mm dia specimen 1 No. Two way split former for 38 mm dia specimen 1 No. Rubber sheath for 38 mm dia specimen 12 Nos. Drainage tube (short), 38 mm 4 Nos. Drainage tube (long), 38 mm 4 Nos. “O’ rings for 38mm dia specimen 4 Nos. Split Mould, 38mm dia 1 No. Top loading pad 38mm (plain) 1 No.
45Unconfined Compression TesterDigital Load Frame with LCD 50 kN Capacity with 4 Speed variations. Horizontal Clearance - 430 mm Vertical clearance - 950 mm Maximum Platen dia - 150 mm Maximum Platen Travel - 100mm Ram Dia - 50mm Suitable for operation on 220 V, 50 Hz, single phase, AC supply. Ring capacity - 2 kN Dial Gauge - 25 mm, 0.01 mm least count. Mould - 38 mm dia × 76 mm long Rubber Sheath - 38 mm dia specimen
46Proctor Test Apparatus for light compactionCompaction Mould Compaction Mould 100 mminternal dia x 127.3 mm height, 1000 ml volume complete with collar and base plate, all made of mild steel tie rods of mild steel and wing nuts for clamping. Compaction Rammer, Light Compaction rammer, light, made of mild steel 2.6 kg weight, 50 mm dia compaction face, 310 mm controlled free vertical fall.
47Proctor Test Apparatus for heavy compactionCompaction Mould Compaction Mould 150 mminternal dia x 127.3 mm height, 2250 ml volume complete with collar and base plate, all made of mild steel tie rods of mild steel and wing nuts for clamping. Compaction Rammer, Heavy Compaction rammer, heavy, made of mild steel 4.89 kg weigh, 50 mm dia compacting face, 450 mm controlled free vertical fall.
48Hot air ovenDigital laboratory oven (18""x18""x18""), Hot oven 450mm digital
49Electronic BalanceElectronic Balance upto 500g(Accuracy capacity 0.01 gm), and 5kg (Accuracy 0.1gm)
50Sieve ShakerHaving a sturdy can iron body, the sieve shaker has an inclined sieve table which can accommodate a maximum of seven sieves of 150 mm or 200 mm diameter. To hold the sieves an adjustable top clamping plate is provided.The table has a gyratory motion in addition to tapping action.The operating gear assembly is enclosed in an oil bath fitted with a transparent oil level indicator window. Suitable for operation on 220 V, 50 Hz, single phase supply & supplied with 30cm adaptor.
51Density bottle100ml, 50ml, made of borosilicate
52sand bathdevice with tray, stove, palet, knife, steel top with powder coated, 230V, single phase
53Non Corridible air tight container or can100ml, 200ml, 500ml, 1000ml,
54Metre scale300mm length, steel made
55Thermometer0.5"c-60"c
56Water bath15L capacity, temperature controlled, LED water bath
57Glass measuring cyliner1000ml
58stopwatchaccuracy: 0.001 seconds
59Ordinary or Non-Recording Rain GaugeNon Recording Rain Gauge should be manufactured from non-corrosive fiberglass reinforced plastic as per IS: 5225: 1969. Must consists of collector assembled with Gunmetaling, Funnel, Locking Rings and Base.
60SELF-RECORDING RAIN GAUGERain Gauge shold be as per IS 5235: 1969 and made from reinforced fiberglass plastic. Container is assembled with Gunmetal Ring and Locking arrangements. Siphoning system and Recording arrangements are manufactured from PVC. The high Torque Quartz Clock of min 25 hours revolution. Must Suppy 100-charts, pen, 15 cc ink
61Open Evaporation PanThe Pan shuold be manufactured from G I sheet as per IS: 5973: 1998, duly tinned and epoxy pointed, and tested for no water leakage.
62Wind VaneManufactured as per IS: 5799: 1970
63ANEMOMETER CUP COUNTERManufactured as per IS: 5912: 1970
64Stevenson screenManufactured from best quality Indian seasoned wood and accurately assembled with side louvers as per IS: 5948:1970 and are suitable for housing Dry Bulb, Wet Bulb, Maximum and Minimum Temperature Thermometer.
65Set of Thermometersset of thermometers which will be used for measurement of maximum, minimum air temperature and relative humidity
66Double Ring InfiltrometerInfiltrometer rings made from Min.14 gauge MS sheet rolled and butt-welded. Hammering end reinforced with ½” iron strip and other end sharpened for smooth entry in to soil. Complete with one inner ring 30-cm dia.; one outer ring 45 cm dia. Min. Height of rings 30-cm; Must supply additionally: Driving Plate with Hammer; Float, Guide rod, Pointer Gauge & Stop watch.
67Pigmy Cup Type Current MeterIt should be suitable to measure the water velocities up to 1.5 m/sec. It has to meet the requirements of IS: 3910 and supplied duly calibrated from Govt. Research Institute.
68Cup Type Current MeterIt should be suitable to measure the water velocities up to 2.5 m/sec. It has to meet the requirements of IS: 3910 and supplied duly calibrated from Govt. Research Institute. Accessories required: 10 Kg fish weight, 10 m suspension cable and other accessories.
69Automatic Weather stationMicroclimate monitoring system with 3.5mm stereo plug, 5m cable Solar radiation: Range: 0 to 1750 W/m2 Resolution: 1 W/m2 Accuracy: ± 5% of measurement typical Precipitation: Range: 0 to 400 mm/h Resolution: 0.017 mm Accuracy: ± 5% of measurement from 0 to 50 mm/h Vapor Pressure: Range: 0 to 47 kPa Resolution: 0.01 kPa Relative Humidity Range: 0 to 100% RH (0.00-1.00) Resolution: 0.1% RH Air temperature: Range: -50 to 60 °C Resolution: 0.1 °C Accuracy: ± 0.6 °C Humidity sensor temperature: Range: -40 to 50 °C Resolution: 0.1 °C Accuracy: ± 1.0 °C Barometric pressure Range: 50 to 110 kPa Resolution: 0.01 kPa Accuracy: ± 0.1 kPa from -10 to 50 °C, ± 0.5 kPa from -40 to 60 °C Horizontal wind speed Range: 0 to 30 m/s Resolution: 0.01 m/s Accuracy: the greater of 0.3 m/s or 3% of measurement Wind gust Range: 0 to 30 m/s Resolution: 0.01 m/s Accuracy: the greater of 0.3 m/s or 3% of measurement Wind direction: Range: 0° to 359° Resolution: 1° Accuracy: ± 5° Tilt: Range: -90° to +90° Resolution: 0.1° Accuracy: ± 1° Lightning strike count: Range: 0 to 65,535 strikes Resolution: 1 strike Accuracy: variable with distance, >25% detection at <10km typical Range: 0 to 40 km Resolution: 3 km Accuracy: variable There should be no moving parts. Communication: SDI-12 communication Dimension: Diameter: 10 cm Height: 34 cm, includes rain gauge filter Cable Length : 5 Meter Data Logger with user-supplied SIM Data Logger: 5 min to 12 h Timekeeping: Synchronize automatically and on-demand; GPS, cellular, or Utility software Computer communication : Standard USB cable, USB A to micro-USB Internet downloads: SSL/TLS encrypted Mobile communication Bluetooth 5.2 supporting Bluetooth GPS communication: Type: Integrated 56-channel GPS/QZSS receiver Update: Daily (automatic) and on-demand (manual) Accuracy: ±3 m, with good sky view Enclosure rating: IP56, NEMA 3R Sensor input ports:6 Data storage: 8 MB Compliance: ISO 9001:2015, EM ISO/IEC 17050:2010 (CE Mark)
Disclaimer :