}

Multi Level Parking And Commercial Complex At Amnaiganj Ayodhya Multi Level Parking And Commercial Complex At Amnaiganj Ayodhya, Ayodhya-Uttar Pradesh

Ayodhya Farizabad Development Authority has published Multi Level Parking And Commercial Complex At Amnaiganj Ayodhya Multi Level Parking And Commercial Complex At Amnaiganj Ayodhya. Submission Date for this Tender is 18-11-2021. Parking Services Tenders in Ayodhya Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29758695
Multi Level Parking And Commercial Complex At Amnaiganj Ayodhya Multi Level Parking And Commercial Complex At Amnaiganj Ayodhya
Open Tender
Indian
Uttar Pradesh
Ayodhya
18-11-2021

Tender Details

Multi Level Parking And Commercial Complex At Amnaiganj Ayodhya Multi Level Parking And Commercial Complex At Amnaiganj Ayodhya

Key Value

Document Fees
INR 5000 /-
EMD
INR 2524000.0 /-
Tender Value
INR 12.62 Crore /-

BOQ Items

Name of Work: Proposed Commericial Complex with Parking At Amaniganj, Ayodhya
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
2Filling By carted earthin trenches, plinth, sides of foundation, campus etc. in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering including lead upto 50 m & lift upto 1.50 m.
3Disposal of available excavated earth by mechanical transport including loading unloading & stacking up to 5 km from from campus.
4Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8km from the site of work includingwatering, ramming, dressing etc. rate to include cost of all materials, labour and T&P etc. required for proper completion of the work. Under floorLocal river sand.
5Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
6Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. NOTE Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum
7All works up to Plinth level.
8All works above plinth & up to floor V level.
9Centering and shuttering including strutting, propping etc. and removal of form for :
10Foundations, footings, bases of columns, etc. for mass concrete
11Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
12Suspended floors, roofs, landings, balconies and access platform
13Lintels, beams, plinth beams, girders, bressumers and cantilevers
14Columns, Pillars, Piers, Abutments, Posts and Struts
15Stairs, (excluding landings) except spiral-staircases
16Edges of slabs and breaks in floors and walls Under 20 cm wide
17Weather shade, Chajjas, corbels etc., including edges
18Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge.
1920 mm dia. & 150 mm length
20Add for using extra cement in the items of design mix over and above the specified cement content therein.
21Brick work with common burnt clay (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
22Brick work with common burnt clay (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand)
23Brick work with common burnt clay (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 (1 cement : 4 coarse sand) EXTRA FOR HALF BRICK MASONARY
24Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
25Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more
26Providing and fixing bright /matt finished Stainless Steel Sliding Door Bolt of approved quality & make with necessary screws etc all complete. 250x16 mm.
27Providing and fixing SS tower bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm.
28150x10 mm.
29p/f bright / matt finished stainless steel handles of approved quality & macke necess etc all 125mm
30Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
31Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type on Both Side , core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
32Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
33Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters with 1.0 mm thick decorative high pressure laminated sheet, on both faces of shutters, of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
3435 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
35Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
36Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
37Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
38Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
39Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
40Fixed to steel windows by welding
41Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
42Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
434.0 mm thick glass panes
44Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
45(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
46With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
4712 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On smooth surface of wall.
4815 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On rough surface of wall.
4912 mm thick plaster with cement mortar in consisting of 1:3 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. In ceiling
5015 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 Cement: 4 Coarse sand)
51Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by approved make & colours), of 1st quality conforming to IS : 15622, of approved make, in colours & shade, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
52Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
53Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 3 (1 cement : 3 coarse sand) : 25 mm thick
54Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
55Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
56Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red
57Area of slab upto 0.50 sqm
58Providing and fixing machine cut, mirror/ eggshell polished , Granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.“ 18 mm thick Granite in any colour and shade.
59Providing and laying C.C. Trimix Flooring of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be aid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately).
60Finishing wall with water proof cement paint of approved make and quality on new work with three coats to give an even shade. Including supply of all material labour and T & P etc. for proper completion of the work.
61Distempering (two coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N Shalimar, Asian Paints after thoroughly brushing the sufface free from mortar dropping and other forein matter and also including prepairing the surface even with Plaster of Paris or approved synthetic material and sand papered smooth including cost of all material
62Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth Complete.
63Painting two coats over priming coat on steel & other metal surfaces upto 10 cmwidth or sq,mt in areas with superior synthetic enamel such as Luxol-3 Hi-gloss apcolite superlac, Dulux specified finishing to give an even shade & incl. cleaning the surface of all dirt, dust & other foreighn matter sand preparing and knotting incl. cost of all etc. required for proper completion of work.
64Painting two coats over priming coat on wood surfaces upto 10 cmwidth or sq,mt in areas with superior synthetic enamel such as Luxol-3 Hi-gloss apcolite superlac, Dulux specified finishing to give an even shade & incl. cleaning the surface of all dirt, dust & other foreighn matter sand preparing and knotting incl. cost of all etc. required for proper completion of work.
65Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
66Providing & laying of 40 mm brick ballast and sand under floor of toilet /sunken roofs including compacting as per directed by E/I.
67Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing "C" wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thickfrom the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
68Road Marking with hot applied thermoplastic compound with reflectorising Glass Beads on bituminous Surface. Providing and laying of hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @250 gms per sam area thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC : 35 -2015 The finished surface to be level, uniform and free from streaks and holes
69Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification and direction of Engineer-in-charge.
70Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm
71Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm
72Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.( Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).
73Overhead informatory road signage
74Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm.
75The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge.
76Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour,T&P,
77cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
78Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by ngineer-in-Charge and consisting of : i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
79Using rough kota stone.
80Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :
81Using rough kota stone.
82Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.
83Providing Polycarbonate Sheet roofing, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
84Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
85Preparing the concrete floor surface using grinding/ shot blasting cut open all construction joints/cracks to fill with epoxy putty Nitocote VF. same treatment will carried out to treat shrinkage joint also, Providing and applying a coat of Nitoprime 25 @ 4 Sqm /litr over prepered surface. Broadcast anti slip grain @ 2.0 kg/sqm on wet priming coat & leave to dry for minimum 12 hours to firmly embedded into coat and excess grain is to be removed. Providing and applying base coat of solvent free, high build epoxy coating Ist coat Nitoflor FC 150 @ 4 sqm /ltr. /coat over primed surface. 2nd coat providing and applying op coat of solvent free, high buid epoxy coating Nitoflor FC 150 @ 4 sqm/litr/coat finishing as per Fosroc specification / product data sheet , Floor coating shall have a comprehensive strength of 70 N/mm2 , flexural strength 40 N/mm2 and Tensile strength of 20 N/mm2 at 20° C.
86It shall be capable accepting foot traffic at 24 hours vehicular traffic 48 hours and chemical spillage resistance at 7 days, Cost of yellow lining or as per required lining is included in above cost. Total system thickness avg. 1.5 to 2 mm.
87Making grooves of size 6x15 mm in trimix flooring to provide construction / expansion joints with cutting machine with diamond cutting wheel including providing 6x15 mm back up rod and 25 mm wide masking tap filling joints with sealent etc. complete.
88Writing Number on Column in Painting Area as Per design, layout, marking Boxes and Providing Marking Tape and Painting writing Number with Enamel Paint with using Stansil in Box Shape
89Providing fixing of column Guard with material fixing 100x100x800 mm thickness 10 mm i/c fixing of S.S. Screw 50x8 mm column Guard made with pubberised material
90P/L Apron Drain
91BILL OF QUANTITY (WATER SUPPLY AND SANITARY)
92Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
93White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
94Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
95W.C. pan with ISI marked white solid plastic seat and lid
96Providingandfixing wash basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting andmaking good the walls where required :
97White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
98White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
99Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
100One urinal basin with 5 litre white P.V.C. automatic flushing cistern
101Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
102Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth
103Granite stone of approved shade
104Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.
105Sink without drain board
106610X510 mm bowl depth 200mm.
107Providing & fixing PVC waste pipe for sink oncluding PVC waste fitting Complete
108Flexible Pipe
10932mm Dia
11040mm Dia
111Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
112Circular shape 450 mm dia
113Rectangular shape 1500x450 mm
114Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
115Providing and fixing toilet paper holder :
116C.P. brass
117Providing and fixing soil, waste, vent pipes
118Centrifugally cast (spun) iron S&S pipe
119100mm dia cast (spun) iron S&S pipe
120Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc.
121For 100mm dia. Pipe
122Providing and fixing heel rest sanitary bend, in Centrifugally cast (spun) iron pipe S&S
123100mm
124Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.
125100X100X100mm
126Sand cast iron S&S as per IS : 3989
127Providing and fixingPLAIN JUNCTIONof required degree
128100X100X100mm
129Sand cast iron S&S as per IS : 3989
130Providing and fixing terminal guard:
131100mm
132Sand cast iron S&S as per IS - 3989
133Providing and fixing collar.
134100mm
135Sand cast iron S&S as per IS - 3989
136Providing and lead caulked joint
137100 Dia
138Providing and fixingcast iron trap of self cleansing design withcast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.
139100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989
140Painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. over a coat of primer (of approval quality) for new work
141100mm dia
142Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
143Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms
144Providing and fixing PTMT towel rail complete with brackets fixed wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
145600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
146Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall
14715 mm dia nominal bore
14820 mm dia nominal bore
14925 mm dia nominal bore
15032 mm dia nominal bore
15140 mm dia nominal bore
152Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall
15315 mm nominal outer dia pipes
15420 mm nominal outer dia pipes
155Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. External work
15640 mm dia, nominal bore
15750 mm dia, nominal bore
158Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)
15925mm dia, nominal bore
16032 mm dia, nominal bore
16140 mm dia, nominal bore
16250 mm dia, nominal bore
163Providing and fixing uplasticised PVC connection pipe with brass unions :
16445 cm length
16515 mm nominal bore
166Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet100 mm diameter
167Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)
16815 mm dia nominal bore
16920 mm dia nominal bore
17025 mm dia nominal bore
17132 mm dia nominal bore
17240 mm dia nominal bore
173Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality
17440 mm dia, nominal bore
17550 mm dia, nominal bore
176Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work
17740 mm dia, nominal bore
17850 mm dia, nominal bore
179Providing and fixingG.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)
18015mm nominal bore
18120mm nominal bore
18225mm nominal bore
18332mm nominal bore
18440mm nominal bore
185Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931
18615mm nominal bore
187Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
18815mm nominal bore
189Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.
19015 mm nominal bore
191Providing and fixing PTMT grating of approved quality and colour
192Circular type
193100 mm nominal dia
194Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
195Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m :
196Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
197Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
198150 mm diameter
199Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
200150 mm diameter S.W. pipe
201Providing and fixing square-mouth S.W. gully trap grade "A"’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than
202100x100 mm size P type
203With F.P.S. Bricks class designation 75
204Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
205250 mm dia rcc pipe
206Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 grade
207Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
208With F.P.S. bricks with class designation 150
209Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
210With F.P.S. bricks class designation 150
211BILL OF QUANTITY OF BOUNDARY WALL
212Class-150 brick work in 1:6 cementand Coarse sandmortar in Super structure including supply of all materials, labour tools and plants, etc. required for proper completetion of the work.
213R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 in colums, excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work. Binding wire cost being included in the item.
214R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 in Plinth/Grid beam, excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work. Binding wire cost being included in the item.
215Thermo-Mechanically Treated bars of grade Fe-500D or more work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including straightening, cutting, bending, placing in position and binding for proper completion of the work and including supply of steel & binding wire and its wastage.
21612 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On smooth surface of wall.
21715 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On rough surface of wall.
218Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) (Apex Ultima, Weather coat All guard) Asian/ Berger.
219BILL OF QUANTITY FOR RAIN WATER HARVESTING (Fillteration Tank 2.5 m dia with and 3.00 mt deep for 2 No.)
220Excavation infoundation inordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m& including filling wateringand rammingof excavated earth into the space between the building & sides offoundation trenches or into the plinth and removal& disposal surplus earthas directed by the engineer I/C within a lead of 30 m.from foundation trenches.
221Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
222Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stone aggregate 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
223R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 (1cement : 1.5coarse sand : 3stone ballast) in Slab, excluding supply of reinforcement and its bending with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work.
224Class-150 brick work in 1:6 cementand coarse sandmortar in foundation and plinth including supply of all materials, labour tools and plants, etc. required for proper completetion of the work.
225Thermo-Mechanically Treated bars of grade Fe-500D or more work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including straightening, cutting, bending, placing in position and binding for proper completion of the work and including supply of steel & binding wire and its wastage.
22615 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. In plinth.
227Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
228Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
229Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
230All types of soil
231400 mm dia
232Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
233200 mm nominal size dia
234Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
235200 mm nominal size dia
236Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
237Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
238Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
239Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge.
240Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge.
241Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
242Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
243BILL OF QUANTITY FOR RAIN WATER HARVESTING (Fillteration Tank 2.5 m dia with and 3.00 mt deep for 2 No.)
244Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:
245All kinds of soil
246Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
247Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe.
248Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design:
249150 mm diameter P.V.C. pipe
250Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
251Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :
252With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
253Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
254With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
255INTERNAL ELECTRIFICATION WORK
256Point Wiring
257Wiring point for light with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductorcable as earth ontinuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backalite sheet etc.complete in all respect as directed including matching colour wash.
258Wiring point for two ways light point with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in heavy gauge rigid steel conduit pipePartly concealed in the wall and partly Laid in slabalong with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductorcable as earth continuity wire , GP box and two number two ways piano type switches & ceiling rose/angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc., complete in all respect,as directed, including matching colour wash.
259Wiring point for fan/fresh air fan (light duty exhaust fan) with1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with1.5sqmm. FRLSH PVC insulated multistrand single core copper conductorcable as earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet,etc.complete in all respect,as directed, including matching colour wash.
260Wiring point for plug with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in riggid steel conduit pipe Partly concealed in the wall and partly Laid in slabalong with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductorcable as earth continuity wire , GP box, piano type switch & socket etc.complete in all respect,as directed, including matching colour wash.
261Wiring point for call bell with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in PVC conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire GP box and piano type bell push switch or two pinsocket etc.complete in all respect,as directed, including matching colour wash.
262Wiring point for Exhaust fan with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in heavy gauge rigid steel conduit pipePartly concealed in the wall and partly Laid in slabalong with the reinforcement before concreting complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box and 15 amp piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc.complete in all respect,as directed, including matching colour wash.
263Supply fixing & concealing ofrigid steel conduit in the wall including cutting of brick laying of conduit & fixing it with MS hooks & then plastering.with cement, sand,mortar finished to the level,with matching colour wash including cost of proper thrading of conduit and providing necessary socket ,bend & chucknuts,as directed by engineer incharge with the supply ofmaterial labour and T&P required for proper completion of work.
264Size 20 mm dia 16SWG (1.5mm)thick
265Size 25 mm dia 16SWG (1.5mm)thick
266Wiring point for plug with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable,with 5 amp flush type switch and 3 pin socket on existing board ,complete with 1.5 sq mm FRLSH PVC insulated multistrand copper conductor cable as earth wire.etc.complete in all respect,as directed, including matching colour wash.
267Submains
268Supply & wiring of submains with 2 nos.1.5 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm diaheavy gauge rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with1 no. 1.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.
269Supply & wiring of submains with 2 nos.2.5 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with1 no. 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.
270Supply & wiring of submains with 2 nos.4 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 2.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.
271Supply & wiring of submains with 2 nos.6 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy gauge rigid steel conduitpartly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 4 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.
272Supply & wiring of submains with 4 nos. 6 sq.mmFR PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 4 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire including maching colour wash etc.complete in all respect.
273Supply & wiring of submains with 4 nos.10 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 40 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 6 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect.
274Light&Fan Fixture
275Supply and fixing of recess/surface mounting round 15 W to 18 W LED Cut out Min 150 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. CAT. - AAA
2761980-2200 system lumens, 1101m/W, PF>0.95, THD<10% at full load, CRI>80, with 5 year warrantee
277Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA
2782420 system lumens, 110 Im/W, PF>0.95, THD<10%, CRI>80, sheet Thickness 0.8 mm, Tube with aluminium heat with 5 year warrantee
279Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA
2801100 system lumens, 110 Im/W, PF>0.95 with 5 year warrantee
281Supply and fixing of 3 watt to 6 watt LED Decorative mirror light (spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA
282330-660 systemlumens 1101m/W, PF>0.95, THD<20% at full load , with 5 year warrantee
283Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect including labour. CAT. - AAA
2846600-7920 system lumens, High Power LED with lenses, 110 Im/W, PF>0.95, Potted driver set (Not Circuitory), Phase to Phase Protection at 440V & >300 V auto cut and re-statr feature with 5 year warrantee.
285Supply of ceilling fans with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts,50 Hz, 1-Ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.
286BEE 5 Star rated-1200 mm sweep
287Supply of AC 1400mm Sweep, 230/250 Volts, 50 Hz ceilling fan without regulator, standar down rod, blades etc. complete as required 3 star Rating
288Supply and fixing of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including makingconnection.Complete in all respect.
289Supply & Fixing of AC 300mm Sweep, 230/250 Volts, 50 Hz exhaustfan (Heavy Duty) withblades,cover etc. complete as required
290S.I.T.C of 400mm sweep, wall mounted fan complete with double ball bearing, motor, blades, capacitor etc suitable for single phase 230 volts, 50 Hz., AC supply, complete as required.
291Cables
292Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size
293size 6 sq mm x 4 core
294size 10 sq mm x 4 core
295size 16 sq mm x 4 core
296size 150 sq mm x 3-1/2core
297size 240 sq mm x 3-1/2core
298Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable
299size 6 sq mm x 4 core
300size 10 sq mm x 4 core
301size 16 sq mm x 4 core
302size 150 sq mm x 3-1/2core
303size 240 sq mm x 3-1/2core
304Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable
305size 6 sq mm
306size 10 sq mm
307size 16 sq mm
308size 150 sq mm
309size 240 sq mm
310Earthing System
311Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated,Length 3000mm,outer pipe 48.4mmx3.2mm,inner pipe 26.9mm x 2.6 mm,terminal Dia 12mm,coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing.(From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified.
312Supply and laying of 25mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
313Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side.
314Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.
31550 mm dia
316100 mm dia
317L.T. Switch Panel Board
318Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.
319The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.
320The MCCB"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type
321Incoming -
322630 amp MCCB - 1 No.
323Outgoing -
324100 amp MCCB - 05 Nos,
32540 amp MCCB - 01 Nos (spare)
326(or As per requirment directed by Project Manager.)
327DBs & MCBs
328Supply and fixing of 240 volts C Curve6-32 amp SPminiature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A
329Supply and fixing of 240 volts C Curve 40 amp4Pminiature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A
330Supply and fixing of 240 volts C Curve 63 amp4Pminiature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A
331Supply and fixing of80-100 amp 4 pole MCCB(16 KA ) thermal magnetic relese. CAT A
332Supply and fixing of flush/surface mounting 6 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal doorcomplete in all respects. As directed by engineer incharge. CAT A
333Supply and fixing of flush/surface mounting 8 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal doorcomplete in all respects. As directed by engineer incharge. CAT A
334Supply and fixing of flush/surface mounting 4 ways V TPN distribution board without MCB with additional metal doorcomplete in all respects. As directed by engineer incharge. CAT A
335Supply & Fixing of MCB blanking plate for DB.
336Miscellaneous Items
337Supply and Fixing of Danger Board fabricated from 10 gauge M.S. Sheet as per I.E. Rules
338Supply & Erection and testing of Ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
339Erection and testing of exhaust fan on the existing hole with suitable size rag bolt nut & washer etc. complete in all respects.
340Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finshing propely complete in all respect.
341Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules
342Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work.
343Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (for Air conditioning/Main incoming.)
344S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.
345Supplying and fixing TV antenna socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
346Supply & Fixing of LAN socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
347Supplying and drawingCo axial T V cable,RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required.
348Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
3491 run of cable
350Electronic Items
351Supplyfixingofelectronic fan regulator 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
352Supply and fixing of Three phase multifunctional electronic energy meter 10 to 60 Amp. Capacity fitted in intergral box on wall complete in all respect.
353Pressurized mechanical ventilation system in the basements with Supply duct of exhaust blowers (on basement area only)
354Shoppin Complex Fire Fighter Work
355Fire Alarm & Fire Fighting System
356Fire Alarm System :
357Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
358Two Loop
359Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
360Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
361Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required.
362Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
363Supplying, installation, testing & commissioning of fault isolator complete with base as required.
364Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required.
365Supplying, installation, testing & commissioning of addressable fire control module complete as required.
366Supplying, installation, testing & commissioning of addressable manual call point complete as required.
367Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
368Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
369Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
370Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
371Fire Fighting System :
372Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts.
373Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required.
374Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
375Supplying, fixing, testing & commissioning of double flanged Sluice Valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
376100 mm dia
377Providing and Fixing 25 mm dia Flexible Stainless Steel (SS 304) Pipe for making final connection of sprinkler head with sprinkler system piping network including 2 nos. 25 mm diameter G.I. connector, G.I. Nipple, Reducer, elbow and threaded jointing complete as per detail. Make:- Newage.
3781000 mm Long
3791500 mm Long
380Providing and Fixing M.S Structural Work fabricaed from standard sections e.g MS rounds, angles, channels including cutting to size, drilling, welding, fixing and welding to insert plates in RCC structural members as directed by Engineer-in-Charge including cutting and making good the walls and floors (For sprinkler Pipe support etc.).
381Tie Road 10 mm
382Angle Frame 35 / 40 mm x 5 mm
383Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site.
384Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump
385Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
386Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-"F" insulation, conforming to IS-325.
387M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
388Suitable cement concrete foundation duly plastered and with anti vibration pads.
389900 lpm at 35 m Head
390Providing, fixing, testing and commissioning of precharged Air Vessel (Sutable size & Sutable height in mm) fabricated shell from 8 mm thick & dished end 10 mm thick M.S.Plate for pressurization of Hydrant/Sprinkler system complete with adequate pressure switches (as per design / requirement) with valve to operate as per operating sequences including 25 mm dia drain valve, air release valve with ball cock on top, 80 mm dia flanged inlet with isolating valve duly painted from inside and out side complete as required.
391150 mm dia
392Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
39325 mm dia
39432 mm dia
39540 mm dia
39650 mm dia
39765 mm dia
39880 mm dia
399100 mm dia
400150 mm dia
401Providing, fixing, testing & commissioning of heavy duty MS pipe (Galvanised) class "C", IS : 3589 marked with all necessary fittings like tees,elbows, flanges,reducers,gaskets,nuts and bolts etc. welded or screwed joints as required including fixing the pipe with necessary structural supports (for delivery/suction manifold related to the pumps) including painting of two coats of synthetic enamel paint over two coats of red oxide zince chromate primer including all civil breakages and making good the same [Location : Plant room]. Make: Tata/Zindal.
402200 mm Dia (6 mm thick) with necessary supports etc. as required.
403Providing, fixing, testing & commissioning of flanged end Basket Strainer made from MS body with bottom and top removable flanges with nuts, bolts etc havingfilteration area at least 6 times the cross sectional area of the pipe. Make: Kalpana/Kartar/Sir/Advance.
404200 mm dia
405Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
40680 mm dia
407100 mm dia
408Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
40980 mm dia
410100 mm dia
411Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2.
412Providing, fixing, testing & commissioning of installation Control Valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
413100 mm dia
414FIRE HYDRANT SYSTEM (INTERNAL) :
415Providing Laying, Testing & Commissioning of “C” class Heavy Duty MS Pipe conforming to IS 1239/3589 (all pipes shall be ISI marked and of makes specified in the specifications) i/c fittings like Elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in groundincluding excavation & providing cement concrete blocks as supports and anti-corrosive treatment to burried pipes by wrapping & coating with 4 mm thk. (OR 2 COATS of 2mm thick tape) anticorrosion tape along with two coat of black japan primer for under-ground pipeincluding digging and backfilling upto 1.0 mtr. below from G.L.for external work as per IS-909
416(Specification for Underground Fire Hydrant.(Under Ground)
417Make :– Jindal / Tata
418150 nominal bore (class C)
419100 nominal bore (class C)
42080 nominal bore (class C)
421Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
422Single headed Stainless steel
423Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
424Make: Firejeet / Minimax / Newage.
425Stainless Steel (Grade 304)
426Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
427Stainless Steel
428Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
42940 m
430Providing & Fixing of 1.6 mm thick M.S / Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).
4312100x900x600 mm (Indoor Cabinet)
432Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
433SPRINKLER SYSTEM:
434Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
435Pendent Sprinkler
436Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass connection to drain pipe/riser.
437FIRE EXTINGUISHERS
438Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
439Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
440Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets).
4416 nos.Fire Bucket Without canopy
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail