Supply, Erection, Testing And Commissioning Of Diesel Generating Set 82.5 Kva For Oxygen Generation Plant In Sdh Mukerian, Distt. Hoshiarpur Supply, Erection, Testing And Commissioning Of Diesel Generating Set 82.5 Kva For Oxygen Generation Plant In Sd, Mukerian-Punjab

Public Works Department-PWD has published Supply, Erection, Testing And Commissioning Of Diesel Generating Set 82.5 Kva For Oxygen Generation Plant In Sdh Mukerian, Distt. Hoshiarpur Supply, Erection, Testing And Commissioning Of Diesel Generating Set 82.5 Kva For Oxygen Generation Plant In Sd. Submission Date for this Tender is 01-11-2021. Diesel Generators Tenders in Mukerian Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

29671512
Supply, Erection, Testing And Commissioning Of Diesel Generating Set 82.5 Kva For Oxygen Generation Plant In Sdh Mukerian, Distt. Hoshiarpur Supply, Erection, Testing And Commissioning Of Diesel Generating Set 82.5 Kva For Oxygen Generation Plant In Sd
Open Tender
Indian
Punjab
Mukerian
01-11-2021

Tender Details

Supply, Erection, Testing And Commissioning Of Diesel Generating Set 82.5 Kva For Oxygen Generation Plant In Sdh Mukerian, Distt. Hoshiarpur Supply, Erection, Testing And Commissioning Of Diesel Generating Set 82.5 Kva For Oxygen Generation Plant In Sdh Mukerian, Distt. Hoshiarpur

Key Value

Document Fees
INR 5000 /-
EMD
INR 22400.0 /-
Tender Value
INR 11.17 Lakhs /-

BOQ Items

Name of Work:Supply, Erection, Testing and Commissioning of Diesel Generating Set 82.5 KVA for Oxygen Generation Plant in SDH Mukerian, Distt. Hoshiarpur.
Sl. No. Item Description
1Supply, Erection, Testing and Successful Commissioning of Diesel Generating Set 82.5 KVA Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 82.5KVA/ 66KWWith AMF Panel Outdoor Type, Three Phase, 415 Volts, 50Hz, 1500 RPM. It should be air cooled/ water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). DG should be operated/controlled through AMF as well as manualy. ENGINE: The Diesel engine developing suitable BHP for giving a power rating as per ISO 8528- Part-1 (with CPCB-II Norms) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil both type) as per manufacturer standard. A mechanical/ electronic governor OF TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication,Lubrication oil cooler, Lubricant oil filter with replaceable elements, RPM indication.
2ALTERNATOR: The alternator should be designed as per (IS4722 AND IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 voltS, SPDP (Screen Protected Drip Proof), Degree of protection : IP-23, Ventilation : Self ventilated air cooled. Alternator should have 40 degree with maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 suitable for outdoor installation exposed to weather conditions, noise level upto 75 db (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodation in the battery rack. The acoustic lining should be made up to high quality insulation material i.e. Rockwool/ glass/ mineral wool/ PU foam of appropriate thickness & density for sound absorption. The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.
3AMF CONTROL PANEL : AMF control panel shall be fabricated aut of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating, MCCB (Fixed Thermal and Adjustable Thermal Protection)/ ACB (Over current/ overload, short circuit, instantenous, earth fault protection) should be used. Battery charge complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo filled on the engine. All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System operation facility provided shall affored the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequiency Meter, Battery Charger etc. complete in all respect.The Generator set should be installed on plinth of suitable size as per desired by the Make : Koel Green/ Sudhir/ Caterpillar/ Mahindra
4SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push,6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point)and other petty material etc., including the cost of above material and painting as required:-
5Wiring fan point (Without fan box)
6Wiring light point
7PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
8Overall size 6sq.mm (Un-sheathed)
9XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armouredandservedcable1100 volts grade as per IS 7098 (Part-1)1988 to belaidlooseintheexistingtrenchor pipe as per PWD General Specifications. Make- Polycab, Havells, RR, KEI, Rallison, Ultracab
10Overall size 70sq.mm(3½ Core) Un- armoured (Loose)
11PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materialsetc., as per PWD General Specifications:-
12Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
13COPPEREARTHING(Upto8metrein Length): Earthingwith electrolyticCopperTape rivetted(with5Nos.copperrivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thickcopper plate (made cylindrical) burried 4.50 metre (14.76feet) below ground level in the hole of excavationhavingbore dia. 125mmandsurroundedbysalt& charcoaldustmixture(20kg.)including fixingtheCopperTaperecessedinwall and in floor etc.,up to 8metre in Length (includingboreLength).G.I.pipe20mm dia. (A-class), 3metre long should be laid intheholeofexcavation1feetbelow ground level and having GI Reducer 50mmx20mmwithPVCCap(For pouringwater)fixedonthetoplevelof the pipe. 300mm x 300mm x 300mm deep haudiofFirstclassbricksfinishedwith 1:4 cement plasterand haudi covered withcastironlidhavingsize300mmx 300mm(Heavy)aroundtheholeof excavation:-
14Earthingwith25mmx3mmCopperTape (upto 8Metre in Length)
15COPPEREARTHINGSTRIP(As Additional Length): Fixing additional Length of earthing with CopperTape(OnSurface/Flushed)with petty material as required etc.:-
16AdditionalLength25mmx3mmthick Copper Tape
17MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specificationsincluding connections with suitable size of thimbles/lugs:-
18MCB Single Pole 6-32amp. (10kA, Curve-C)
19MCB Double Pole 40amp. (10kA, Curve-C)
20SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB"s/ RCBO"s/ RCCB"s: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mountingminiature circuit breakers/ RCBO"s/ RCCB"s in the distribution board (For SP&Ndistribution board with provision DP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings and for TP&Nhorizontal distribution board with provision TPN/ FP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
21SP&N Double Door Distribution Board 4 way each
22ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure): Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-
23On Load Change Over Switch Four Pole 160amp., 415volts (With Sheet Enclosure)
24MCCB"s (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
25MCCB Four Pole 160amp., 415volts, =25kA Microprocessor Based Adjustable Thermal and Magnetic Setting
26MS SHEET ENCLOSURE FOR MCCB"s: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
27MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
28DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supplyand erectionof DoubleWalled Corrugated(DWC)HDPEpipetobelaid 1mtr.belowgroundlevelincluding excavationplacingthepipeinposition andbackfillingwithexcavatedsoiletc. of the required size. Make - Telerex, Gemini, CPE, Duraline.
29Double WalledCorrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
30Supplyanderectionofheavydutyaluminiumthimbles/lugsforcableendterminationdulycrimpedincludingmaking necessary connections completely:-
31Aluminiumthimblecable Coresize 70sq.mm
32Supplyanderectionofheavydutybrasssinglecompressionglandforcableendterminationdulycompletewith checknuts etc. including making necessary connections:-
33Brass Glandfor Aluminium cable3/3½/4 Core size 70sq.mm
34Cost ofPlinth of suitable size for DG set capacity 82.5KVA
35Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting"s should be as approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make:- WIPRO:- LL24-541-XXX-57-CD,BAJAJCat No. BCLAB40W ,JAQUAR CAT NO. LGLZ01X040XC, PHILIPS Cat no:-BN108C LED 40 S PSU CDL WH , CROMPTON:-LDL-40-CDL,C&S:-LTTB4F40WLED /W,HAVELLS:-STOUTPLUS1200BS40WLED840SPCWH
36Supply and erection of Ceiling Fan 1200mm (FIVE STAR), 48" with double ball bearing but without regulator including flexible wire & petty material etc. for connections and testing . complete in all respects as appd. and desired by the Engineer in-charge at site. Makes:- Crompton (High Speed)/ Havell"s (SS-390)/ Orient (New Breeze)
37Supply and erection of Heavy duty Exhaust Fans 380mm 900RPM with louver shutter ,double ball bearinglonger life including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. Make:-Crompton EXHD380-6-1 /Havells Turbo Force SP / Anchor Anmol Heavy Duty .
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail