}

Fixing Of Two Nos Mooring Ring Over Tarmac, Provision Of Borewell, Submersible Pump At Alg Ziro, Special Repairs To Dg Sets And Ac Against Ber And One No 50 Kva Stabilizer At Ziro And Two Nos 75 Kva Stabilizer , Cln Bpi Tank 15Kl Cacty At Afs Tezpur Fixin, AFS TEZPUR-Assam

Military Engineer Services-MES has published Fixing Of Two Nos Mooring Ring Over Tarmac, Provision Of Borewell, Submersible Pump At Alg Ziro, Special Repairs To Dg Sets And Ac Against Ber And One No 50 Kva Stabilizer At Ziro And Two Nos 75 Kva Stabilizer , Cln Bpi Tank 15Kl Cacty At Afs Tezpur Fixin. Submission Date for this Tender is 06-11-2021. Diesel Generators Tenders in AFS TEZPUR Assam. Bidders can get complete Tender details and download the document.




Tender Notice

29667802
Corrigendum : Fixing Of Two Nos Mooring Ring Over Tarmac, Provision Of Borewell, Submersible Pump At Alg Ziro, Special Repairs To Dg Sets And Ac Against Ber And One No 50 Kva Stabilizer At Ziro And Two Nos 75 Kva Stabilizer , Cln Bpi Tank 15Kl Cacty At Afs Tezpur Fixin
Open Tender
Indian
Assam
AFS TEZPUR
06-11-2021

Tender Details

Fixing Of Two Nos Mooring Ring Over Tarmac, Provision Of Borewell, Submersible Pump At Alg Ziro, Special Repairs To Dg Sets And Ac Against Ber And One No 50 Kva Stabilizer At Ziro And Two Nos 75 Kva Stabilizer , Cln Bpi Tank 15Kl Cacty At Afs Tezpur Fixing Of Two Nos Mooring Ring Over Tarmac, Provision Of Borewell, Submersible Pump At Alg Ziro, Special Repairs To Dg Sets And Ac Against Ber And One No 50 Kva Stabilizer At Ziro And Two Nos 75 Kva Stabilizer , Cln Bpi Tank 15Kl Cacty At Afs Tezpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-11-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 73800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:FIXING OF TWO NOS MOORING RING OVER TARMAC IN TECHNICAL AREA, PROVISION OF BOREWELL AND CONNECTED ACCESSORIES AT VARIOUS LOCATIONS, SPECIAL REPAIRS/REPLACEMENT OF ACs AT VARIOUS OTM & TECH ACCN AGAINST BER,PROVISION OF SUBMERSIBLE PUMP AT ALG ZIRO,CLEANING OF BPI TANK OF CAPACITY 15 KL IN TECHNICAL AREA,SPECIAL REPAIRS TO DG SETS AT VARIOUS LOCATIONS,PROVISION OF ONE NO 50 KVA STABILIZER FOR ALG EQUIPMENTS AT ALG ZIRO AND PROVISION OF TWO NOS 75 KVA STABILIZER IN CERTAIN UNIT AT AF STN TEZPURUNDER GE (AF) TEZPUR.
Sl. No. Item Description
1Re- development,reaming in bore of 150 mm dia casing pipe reduced to 80mmbelow ground level exceeding 120 Feet depth and upto 40 RM, in any kind of soil strata including hard stone/boulder and including yield test for the bore well by continuously pumping for 08 hours to determine safe pumping yield of clear water and submission of testing report(s), complete all as specified and as directed.
2Supply, lowering and fixing in position 150 mm nominal bore,unplacticized polyvinyle chloride (PVC-U) casing pipe for bore/tube wells, ISI Marked (IS 12818 : 2010),complete all as specified and directed.
3Supply, lowering and fixing in position 150 mm nominal bore,unplacticized polyvinyle chloride (PVC-U) ribbed screen pipe for bore/tube wells,complete all as specified and directed.
4Supply, lowering and fixing in position 80 mm nominal bore,unplacticized polyvinyle chloride (PVC-U) casing pipe for bore/tube wells, ISI Marked (IS 12818 : 2010),complete all as specified and directed.
5Supply and Fix, cast copper alloy vertical check valve, 80mm size, ISI Marked [IS : 778 - 1984 (Reaffirmed 1995)],complete all as specified and as directed.
6Supply and Fix, unplacticized polyvinyle chloride (PVC-U) casing reducer 150 mm x 80 mm for casing pipe of bore/tube wells,complete all as specified and directed. .
7Supply and Fix, unplacticized polyvinyle chloride (PVC-U) end cap ,150 mm size, for casing pipe of bore/tube wells,complete all as specified and directed. .
8Supply and Fix, unplacticized polyvinyle chloride (PVC-U) casing cone SCH-80, size 80 mm for casing pipe of bore/tube wells,complete all as specified and directed. .
9Providing water logging test with electro logging equipment and required machinery for ascertaining/ logging aquifers encountered in trial bore against Serial Item No.1 here in before and arranging and defining the water availability test giving test report of Geo-Hydrologist from Govt. approved laboratory recommending water bearing zones, TDS of water etc., complete all as specified and directed.
10Supplying, pouring and packing pea-gravel of size 3 mm to 8 mm and packed all around the entire bore well to fill in the annular space between pipe assembly and bore hole, complete all as specified and as directed.
11Supply,installation,testing and commissioning of,monoblock pump set suitable for 415 V, 50 Hz ,3 phase system having capacity5 HP, suction and delivery of maximum 17 LPS at 24 meter head, motor and pump with all accessories including making connection to inlet and delivery pipeline,completeall as specified and as directed
12Re- development, reaming in bore of 50 mm dia casing pipe reduced to 25 mmbelow ground level exceeding 75 Feet depth and upto 25 RM, in any kind of soil strata including hard stone/boulder and including yield test for the bore well by continuously pumping for 02 hours to determine safe pumping yield of clear water and submission of testing report(s),complete all as specified and as directed. (For 03 Nos Bore Well )
13Supply, lowering and fixing in position 50 mm nominal bore,unplacticized polyvinyle chloride (PVC-U) casing pipe for bore/tube wells, ISI Marked (IS 12818 : 2010),complete all as specified and directed.(For 03 Nos Bore Well )
14Supply, lowering and fixing in position 50 mm nominal bore,unplacticized polyvinyle chloride (PVC-U) ribbed screen pipe for bore/tube wells, complete all as specified and as directed. (For 03 Nos Bore Well )
15Supply, lowering and fixing in position 25 mm nominal bore,unplacticized polyvinyle chloride (PVC-U) casing pipe for bore/tube wells, ISI Marked (IS 12818 : 2010),complete all as specified and directed. (For 03 Nos Bore Well )
16Supply and Fix, cast copper alloy vertical check valve, 25 mm size, ISI Marked [IS : 778 - 1984 (Reaffirmed 1995)],complete all as specified and as directed.
17Supply and Fix, unplacticized polyvinyle chloride (PVC-U) casing reducer 50 mm x 25 mm for casing pipe of bore/tube wells,complete all as specified and directed. .
18Supply and Fix, unplacticized polyvinyle chloride (PVC-U) end cap,50 mm size, for casing pipe of bore/tube wells,complete all as specified and directed. .
19Supply and Fix, unplacticized polyvinyle chloride (PVC-U) casing cone SCH-80, size 25 mm, forcasing pipe of bore/tube wells,complete all as specified and directed. .
20Providing water logging test with electro logging equipment and required machinery for ascertaining/ logging aquifers encountered in trial bore against Serial Item No.12 here in before and arranging and defining the water availability test giving test report of Geo-Hydrologist from Govt. approved laboratory recommending water bearing zones, TDS of water etc., complete all as specified and directed.
21Supply and Fix, Fully Automatic Star Delta Starter with Single Phase Preventer, in sheet steel enclosure, suitable for 5 HP pump 3Ø, 415V, 50Hz, relay range 6 - 10 A , coil voltage 360V-W (200V-400V), all as per Cat No. "CS94091SOVO" of Make "L&T or equivalent Model of Make BCH/Seimens/ABB,complete all as specified and directed.
22Supply,installation,testing and commissioning of,monoblock pump set suitable for 240 V, 50 Hz ,single phase system having capacity 1.5 HP, suction and delivery of maximum 2 LPS at 22 meter head, motor and pump with all accessories including making connection to inlet and delivery pipeline,completeall as specified and as directed. Note:- Old unsrviceable pump motor shall be deposited to MES Store and receipt voucher obtained.
23Supply and Connecting, flat three core, PVC insulated industrial cable for submersible motor, 1.50 Sq. mm (Nominal area) with multi stranded copper conductor, 1100 Volts grade,conforming to IS: 694,connected from starter to pump motor, complete all as specified and directed.
24Supply and Connecting, flat three core, PVC insulated industrial cable for submersible motor, 4.00 Sq. mm (Nominal area) with multi stranded copper conductor, 1100 Volts grade,conforming to IS: 694,connected from starter to pump motor, complete all as specified and directed.
25Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.50 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work complete all as specified and directed.
26Materials and Labour for,cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint,complete all as specified and directed.
27Materials and Labour for, 32 mm outer diameter 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches,complete all as specified and directed.
28Materials and Labour for, 90 mm outer diameter 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches,complete all as specified and directed.
29Supply and Fix,direct on line starter( DOL Starter) with relay range 10.5 to 17.5 Amps, suitable for pump/motor 1Ø, 230V, 50Hz with maximum motor output of 1.50 HP all as per Cat No."SS97227" of Make "L&T or equivalent Model of Make BCH/Seimens/ABB, complete all as specified and directed.
30Supply and Fix, cast iron sluice valve, size 80 mm bore, Class PN 1.0, long body type, with brass spindle, both ends flanged with holes, ISI Marked (IS 14846-2000), provision of carbon steel nuts, bolts & washers, rubber gaskets etc., with CI wheel, fixed to water mains,complete all as specified and directed.
31Supply and fix, cast iron double flanged swing check type reflux valve of size 80 mm bore, Class PN 1.0, with vertical seating and integral by-pass arrangement ,both ends flanged with holes, ISI Marked (IS-5312: 2004) provision of nuts, bolts& washers, rubber gaskets etc., fixed to water mains,complete all as specified and directed.
32Supply and fixPP-R Gate Valve (Brass insert) for 32 mm outer diameter of pipe,complete all as specified and directed.
33Supply and Fix, cast copper alloy multiutility check valve, 25 mm size,complete all as specified and as directed.
34Cutting existing steel tubing 80 mm bore for alterations or additions,screwing for alterations or additions (or lengthening screw on pipe to form connector) and inserting tee,including all accessories and jointing materials,complete all as specified and directed.
35Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil , complete all as specified and directed.
36Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil , complete all as specified and directed.
37Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
38Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and directed.
39Removing excavated soils to a distance exceeding 50 Metres and not exceeding 100 Metres and depositing where directed at a level n. exc.1.5 M above the starting point complete all as specified and directed.
40Cutting of pavement quality concrete of flextural strength 40 kg/sqcm or more in tarmac by mechanical or manual diamond cutter machine without disturbing sorrounding tarmac and cleaning the cutting area of tarmac and disposed rubbish outside the MOD land,complete all as specified and directed.
41Placing in position Mooring Ring (Anchor Bolt) in foundation trench over PCC subase,complete all as specified and directed. Note:- Mooring Ring (Anchor Bolt) will be provided by user at site which is a heavy weight structure and which may require mechanical boom type crane for lifting,towing and placing purpose,as such the quoted rate is deemed to be inclusive of lifting,towing and placing the same by mechanical means.
42Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sided and soffits of plinth beams and similar works; vertical or to batter for rough finished surfaces of concrete, flat, complete all as specified and directed.
43Materials and Labour for plain cement concrete (1:2:4) Type B-2 using 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed.
44Materials and Labour for reinforced cement concrete (1:1½:3) Type A1,using 20 mm graded aggregates in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete ,complete all as specified and directed.
45Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
46Supply and Install in repair, Inverter type Split AC unit 1.5 Ton capacity, indoor & outdoor units with cordless remote control for indoor unit and with in built air ioniser and plasma filter for better indoor air quality with BEE 5 star rating and EER 3.2,operated in single phase AC supply, including necessary interconnection refrigerent copper tubing of required dia. & length duly insulated,condense water PVC rigid piping not less than 19mm external dia. and 2 mm wall thickness, outer unit stand made out of stain less steel including leakage testing duly filed with CFC free refrigerant for fixing of compressor as upto the required pressure as per manufacturer"s instructions and including necessary civil work i.e. making hole, PCC work, MS stand/bracket,duly painted and connection etc., complete all as specified and directed. Notes:- (i) AC refrigerant shall be Non CFC. (ii) Quoted rate shall be deemed to be inslusive of the cost of pipes,cables for connection of outer door and indoor unit and nothing extra shall be admissible on this account. (iii) Old unserviceable ACs shall be deposited in AGE E/M store yard and receipt voucher obtained.
47Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for sub main, complete all as specified and directed.
48Supply and Fix,single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240V, complete all as specified and directed.[Cat No. 5078 11 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/ Schneider/ABB]
49Supply and Fix,voltage stabilizer for automatic operation, single phase, naturally air cooled designed for input voltage variation between 140V to 280V with output voltage stabilized at 230V with accuracy of + 2.5%,capacity 5 KVA,complete all as specified and directed. Note:-Old unserviceable voltage stabilizer shall be deposited in AGE E/M store yard and receipt voucher obtained.
50Supply Only,submersible pump set, 415 V, 50 Hz ,three phase system,capacity 5 HP, 3.7 KW,35 Stages,discharge capacity 69 LPM at 140 meter head,motor and pump with all accessories,suitable for 100 mm internal dia. bore well, complete all as specified and as directed. Note:- Material shall be deposited in AGE E/M store yard alongwith Purchase Voucher, Manufacturer"s Test Certificate, Manufacturer"s Instructions Manual, Guarantee/Warranty Certificate etc.and receipt voucher obtained.
51Supply Only, Fully Automatic Star Delta Starter with Single Phase Preventer, in sheet steel enclosure, suitable for 5 HP pump 3Ø, 415V, 50Hz, relay range 6 - 10 A , coil voltage 360V-W (200V-400V), all as per Cat No. "CS94091SOVO" of Make "L&T or equivalent Model of Make BCH/Seimens/ABB,complete all as specified and directed.Note:-Material shall be deposited in AGE E/M store yard alongwith Purchase Voucher, Manufacturer"s Instructions Manual etc.and receipt voucher obtained.
52Supply Only, flat three core, PVC insulated industrial cable for submersible motor, 4.00 Sq. mm (Nominal area) with multi stranded copper conductor, 1100 Volts grade,conforming to IS: 694,complete all as specified and directed. Note:-Material shall be deposited in AGE E/M store yard alongwith Purchase Voucher, Manufacturer"s Test Certificate etc.and receipt voucher obtained.
53Supply,installation,testing and commissioning of,voltage stabilizer for automatic operation (Servo Controlled),three phase,naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ±2.5% and speed of correction 8 Volts per second and of capacity 50 KVA,complete all as specified and directed.
54Supply,installation,testing and commissioning of,voltage stabilizer for automatic operation (Servo Controlled),three phase,naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ±2.5% and speed of correction 8 Volts per second and of capacity 75 KVA,complete all as specified and directed.
55Supply and Fix, Double Door, Sheet Metal Enclosure for DBs, fitted with Bus Bars, Neutral Links, Blanking Plates, MCCB as incomer and SP/TP MCB"s as outgoing, 415 Volts, 4 Way, Triple Pole & Neutral, Vertical, including provision of moulded case circuit breaker (MCCB),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:5-10 x In, complete all as specified and directed. [Cat No. 5077 45 (For DB) &Cat No. 4200 55 (For MCCB) of Make Legrand or equivalent Model of Make L&T/ Hager/ Seimens/GE/ Schneider/ABB] complete all as specified and directed.
56Supply,laying, jointing and testing of LT, XLPE insulated, PVC sheathed, armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 35 Sq. mm, 3 ½ core, complete all as specified and directed.
57Supply,laying, jointing and testing of LT, XLPE insulated, PVC sheathed, armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 70 Sq. mm, 3 ½ core, complete all as specified and directed.
58Supply,laying, jointing and testing of LT, XLPE insulated, PVC sheathed, armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 95 Sq. mm, 3 ½ core, complete all as specified and directed.
59Supply and Fix,cable jointing kit for 1.1 KV grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3½ core XLPE armoured aluminium conductor cable of size 70 sq mm to 150 sq mm, complete all as specified and directed.
60Supply and Fix,cable jointing kit for 1.1 KV grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3½ core XLPE armoured aluminium conductor cable of size 70 sq mm to 150 sq mm, complete all as specified and directed.
61Supply and filling in dry sand in cable trenches before and after the cables are laid, as in sand cushioning to cables complete all as specified and directed.
62Supply and laying sub class ‘B’, bricks, in cable trenches, as cable protection complete all as specified and directed.
63Supply installation, testing and commissioning of LT Feeder Pillar Box, AC 415 V,50 Hz, 3 Phase, 4 Wire, of over all size 1000 mm (W) x 1100 mm (H) x 600 mm (D), suitable for accommodating the following accessories, totally enclosed self supporting structure/cubicle, fully compartmentalized type,weather proof, protection IP-52, suitable for outdoor use, with bottom cable entry with suitable cable glands ; accessories prewired with suitable size FRLSH PVC insulated multistranded copper conductor; structure made out of 3.15 mm thick CRCA steel sheets with angle iron frame work and legs of ISA-40 x 40 X 5 mm, with four legs (Height 450 mm minimum above platform level) grouted to PCC (1:2:4) Type B1 foundation block; with suitable mounting arrangement for bus bars and accessories, with sloping canopy at top, double hinged doors at front with suitable locking arrangement and bolted rear opening shutters, with suitable locking arrangement; Provision of louvers at sides, structure treated under 8-Tank metal treatment process and duly powder coated, complete all as specified and directed. BUS BAR (i) Electrolytic aluminium bus bar, 200 Amps, supported on non hygroscopic fibres and brass screws for mounting.– 04 (Four) Nos. INDICATING DEVICES:- (i) Digital AC Voltmeter with 3 ½ digit display and with built in selector switch, Type 3 PH, Range 30-600 Volts direct, size 96 mm X 96 mm, Accuracy Class 1.0, all as per Model No AE 62342 of Make “AE” or equivalent Model of Make BCH/ L&T –01(One) Set. (ii) Digital AC Ammeter with 3 ½ digit display and with built in selector switch, Type 3 PH, Range 5 Amp Direct and with CT 200/5 A, size 96 mm X 96 mm, Accuracy Class 1.0, all as per Model No AE 60342 of Make “AE” or equivalent Model of Make BCH/ L&T - 01 (One) Set. (iii) LED Indicator 16 mm with power consumption < 0.6W, LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC (RYB) all as per Model No SIL of Make “L&T” or equivalent Model of Make BCH/ AE - 01 Set (Set of Three) INCOMING & OUTGOING:- (i) Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 125 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In.[Cat No. CM90681OOLOOG of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]- 02 (Two) Nos.
64Supply installation, testing and commissioning of LT Feeder Pillar Box, AC 415 V,50 Hz, 3 Phase, 4 Wire, of over all size 1000 mm (W) x 1100 mm (H) x 600 mm (D), suitable for accommodating the following accessories, totally enclosed self supporting structure/ cubicle, fully compartmentalized type,weather proof, protection IP-52, suitable for outdoor use, with bottom cable entry with suitable cable glands ; accessories prewired with suitable size FRLSH PVC insulated multistranded copper conductor; structure made out of 3.15 mm thick CRCA steel sheets with angle iron frame work and legs of ISA-40 x 40 X 5 mm, with four legs (Height 450 mm minimum above platform level) grouted to PCC (1:2:4) Type B1 foundation block; with suitable mounting arrangement for bus bars and accessories, with sloping canopy at top, double hinged doors at front with suitable locking arrangement and bolted rear opening shutters, with suitable locking arrangement; Provision of louvers at sides, structure treated under 8-Tank metal treatment process and duly powder coated, complete all as specified and directed. BUS BAR (i) Electrolytic aluminium bus bar, 320 Amps, supported on non hygroscopic fibres and brass screws for mounting.– 04 (Four) Nos.INDICATING DEVICES:-(i) Digital AC Voltmeter with 3 ½ digit display and with built in selector switch, Type 3 PH, Range 30-600 Volts direct, size 96 mm X 96 mm, Accuracy Class 1.0, all as per Model No AE 62342 of Make “AE” or equivalent Model of Make BCH/ L&T –01(One) Set. (ii) Digital AC Ammeter with 3 ½ digit display and with built in selector switch, Type 3 PH, Range 5 Amp Direct and with CT 200/5 A, size 96 mm X 96 mm, Accuracy Class 1.0, all as per Model No AE 60342 of Make “AE” or equivalent Model of Make BCH/ L&T - 01 (One) Set. (iii) LED Indicator 16 mm with power consumption < 0.6W, LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC (RYB) all as per Model No SIL of Make “L&T” or equivalent Model of Make BCH/ AE - 01 Set (Set of Three) INCOMING:- (i) Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 200 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In. [Cat No. CM92109OON1OG of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]– 01 (One) No.OUTGOING:- (i) Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 160 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In.[Cat No. DZ1F0160DXD1A of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]- 01 (One) Nos.
65Materials and Labour for,earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, 32x6mm galvanised iron strip,complete all as specified and directed.
66Materials and Labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanised steel earth lead strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil completeall as specified and indicated on electrical plate No 3 of SSR Part –I (2009) including testing on completion.
67Disconnection of inlet and outlet piping system,opening of cover lid by loosening of nuts&bolts,removing gasket materials,of BPI storage tank of capacity 15000 Litres, replacement of cover gasket 24 Inches dia.,nuts,bolts & washers of cover lid,icluding reconnection of piping system and fixing of cover lid after execution of the following works:- (i) Taking out/de-canning of oil from bottom of the tank with suitable mechanical means,removing silts,slurry,waste materials etc. complete. (ii) Preparation of surface of existing treatment inside the tank as per OEM"s instructions for EPI coating. (iii) Provision of EPI coating conforming to the requirements as per ISO 16961:2015(E) standards including checking its effectiveness as per required standards. (iv) Replacement of flange gaskets and 2 Inch size fuel pipe for bye pass connection as per OEM"s specifications. (v)Replacement of filter as per OEM"s specifications.(vi) Servicing of fuel meter and fuel pump as per OEM"s instruction. Note:- The works shall be carried out through skilled technician(s) authorised by the OEM(s).
68Comprehensive maintenance of DG sets of capacity 10/25/30/40 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, lube oil filter(s), fuel filter(s), air filter(s), pipe with fittings, check the level of coolant in radiator etc. Gaskets & Oil seals, servicing of the Water Pump,repairs of Alternator,Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement of toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by Engineer in Charge, complete all as specified and as directed.( Make:Kriloskar)
69Comprehensive maintenance of DG sets of capacity 62.5/63 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, lube oil filter(s), fuel filter(s), air filter(s), pipe with fittings, check the level of coolant in radiator etc. Gaskets & Oil seals, servicing of the Water Pump,repairs of Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement of toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by Engineer in Charge, complete all as specified and as directed. ( Make: Kriloskar)
70Comprehensive maintenance of DG sets of capacity 82.5/87.5 KVA installed at various location by cleaning,Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps,lube oil filter(s), fuel filter(s), air filter(s), pipe with fittings, check the level of coolant in radiator etc. Gaskets & Oil seals,servicing of the Water Pump,repairs of Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement of toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. (Make: Kriloskar)
71Comprehensive maintenance of DG sets of capacity 110/125 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, lube oil filter(s), fuel filter(s), air filter(s), pipe with fittings, check the level of coolant in radiator etc. Gaskets & Oil seals, servicing of the Water Pump,repairs of Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement of toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by Engineer in Charge, complete all as specified and as directed. (Make: Cummins/Kriloskar)
72Comprehensive maintenance of DG sets of capacity 320 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, lube oil filter(s), fuel filter(s), air filter(s), pipe with fittings, check the level of coolant in radiator etc. Gaskets & Oil seals, servicing of the Water Pump,repairs of Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement of toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by Engineer in Charge, complete all as specified and as directed.( Make: Cummins/Kriloskar)
73Comprehensive maintenance of DG sets of capacity 400 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, lube oil filter(s), fuel filter(s), air filter(s), pipe with fittings, check the level of coolant in radiator etc. Gaskets & Oil seals, servicing of the Water Pump,repairs of Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement of toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by Engineer in Charge, complete all as specified and as directed.( Make: Kriloskar/Greaves Cotton)
74Comprehensive maintenance of DG sets of capacity 500 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine andincluding replacement of spares parts like clamps, lube oil filter(s), fuel filter(s), air filter(s), pipe with fittings, check the level of coolant in radiator etc. Gaskets & Oil seals, servicing of the Water Pump,repairs of Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement of toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by Engineer in Charge, complete all as specified and as directed. (Make: Cummins/Kriloskar/Greaves Cotton) NOTES:- (Applicable for BOQ Serial Item No. 68 to 74 here in before) (i) The Contractor shall provide comprehensive services arising out of wear and tear of the normal running of DG Sets.(ii) Preventive and Corrective Maintenance.(iii)Cost of minor items like teflon tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (iv) Spares required for replacement of defective ones except those mentioned against the items will be measured and paid seperately under respective items of this BOQ. (v) The Contractor shall maintain service report(s) for all maintenance works of each DG Set(s) & copy of the same shall be submitted to the Engineer in Charge.
75Supply Only distilled water,all as specified. .Note:- Distilled Water shall be supplied in sealed PET bottles of 1 Litres/2 Litres.
76Supply Only,glycol based antifreeze radiator coolant,all as specified. (Make: Castrol/Bosch/Valvoline) Note:- Coolant shall be supplied in sealed HDPE containers of 1 Litres/2 Litres/5 Litres.
77Supply Only,engine oil, viscosity Grade 20W-40,all as specified. (Make: Castrol/Bosch/Servo/Gulf)Note:- Engine Oil shall be supplied in sealed HDPE containers of 5 Litres/20 Litres.
78Supply and Fix in repairs, Automatic Voltage Regulator (AVR), suitable for AC generator 30 KVA,3 Phase, 415 Volts (Model-TAVR 20), complete all as specified and directed. (Make Kirloskar/ Altex Electric Co./Automation Electronics India/Cummins Generator Technologies India Ltd/Greaves)
79Supply and Fix in repairs, Automatic Voltage Regulator (AVR), suitable for AC generator 125 KVA,3 Phase, 415 Volts (Model-TAVR 30),complete all as specified and directed. (Make Kirloskar/ Altex Electric Co./Automation Electronics India/Cummins Generator Technologies India Ltd/Greaves)
80Supply and Fix in repairs, Automatic Voltage Regulator (AVR), suitable for AC generator 500 KVA,3 Phase,415 Volts (Model-TAVR 30),complete all as specified and directed. (Make Kirloskar/ Altex Electric Co./Automation Electronics India/Cummins Generator Technologies India Ltd/Greaves)
81Supply and Fix in repairs,EMS controller,suitable for AMF panels of DG sets of capacity 30 KVA to 110 KVA,3 Phase,415 Volts (Model-936), complete all as specified and directed.(Make:Kirloskar/Procom/Comap/CSPC/Greaves)
82Supply and Fix in repairs,EMS controller,suitable for AMF panels of DG sets of capacity 400 KVA,3 Phase,415 Volts (Model-926/ KG 645),complete all as specified and directed.(Make:Kirloskar/Procom/Comap/CSPC/Greaves)
83Supply and Fix in repairs,EMS controller,suitable for AMF panels of DG sets of capacity 500 KVA,3 Phase,415 Volts(Model-926/ KG 645),complete all as specified and directed.(Make:Kirloskar/Procom/Comap/CSPC/Greaves)
84Supply,installlation,testing and commissionning of alternator assembly of capacity 63 KVA,3 Phase,415 Volts OEM"s specifications,for DG Set installed in Pump House No.7,including disconnection of LT cables,earthing cables,connections,accessories etc.and taking out carefully existing unserviceable alternator assembly,complete all as specified and directed.(Make:Kirloskar Electric Co./Crompton Greaves/Stamford/Siemens/Bharat Bijlee/Mahindra)
85Supply,installlation,testing and commissionning of alternator assembly of capacity 110 KVA, 3 Phase,415 Volts as per OEM"s specifications, for DG Set installed in Pump House No.2,including disconnection of LT cables,earthing cables,connections, accessories etc.and taking out carefully existing unserviceable alternator assembly,complete all as specified and directed.(Make:Kirloskar Electric Co./Crompton Greaves/Stamford/Siemens/Bharat Bijlee/Mahindra)
86Supply and Fix in repairs, maintenance free lead acid battery,12 Volts,capacity 150 Ah,suitable for DG Set including provision of brass terminals for connection,complete all as specified and directed.[Model : Xpress (XP1500) of Make"Exide"or equivalent Model of Make "Amron"/"Amco"]
87Supply and Fix in repairs, maintenance free lead acid battery,12 Volts,capacity 180 Ah,suitable for DG Set including provision of brass terminals for connection,complete all as specified and directed.[Model : Xpress (XP1800) of Make"Exide"or equivalent Model of Make "Amron"/"Amco"]
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail