}

Rate Contract For Supply Of Hemodialysis Consumable Anddisposable Items ( E-Tender ) For Ikdrc, Ahmedabad- Paediatric Dialyzer ( Low / Middle Flux ) &Middot; 0.5M&Sup2; To 0.9M&Sup2; Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysul-Gujarat

Health And Family Welfare Department has published Rate Contract For Supply Of Hemodialysis Consumable Anddisposable Items ( E-Tender ) For Ikdrc, Ahmedabad- Paediatric Dialyzer ( Low / Middle Flux ) &Middot; 0.5M&Sup2; To 0.9M&Sup2; Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysul. Submission Date for this Tender is 10-11-2021. Coats and Jackets Tenders in Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

29610397
Rate Contract For Supply Of Hemodialysis Consumable Anddisposable Items ( E-Tender ) For Ikdrc, Ahmedabad- Paediatric Dialyzer ( Low / Middle Flux ) &Middot; 0.5M&Sup2; To 0.9M&Sup2; Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysul
Open Tender
Indian
Gujarat
10-11-2021

Tender Details

Rate Contract For Supply Of Hemodialysis Consumable Anddisposable Items ( E-Tender ) For Ikdrc, Ahmedabad- Paediatric Dialyzer ( Low / Middle Flux ) &Middot; 0.5M&Sup2; To 0.9M&Sup2; Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysulfone / Polyethersulfone / Helixone / Polyamix / Polynephrone Synthetic Membrane. €¢Surface Area Up To 0.6 M&Sup2; To 0.9 M&Sup2;&Middot; €¢Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢Housing Material Should Be Have Polypropylene, Eco-Friendly And Light In Weight&Middot; Parameter Range Should Be As Given Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 6-10 2. Urea Clearance Ml / Min ( At Qb -200 Ml / Min & Qd 500 Ml / Min ) 160-180 3. Creatinine Clearance Ml / Min ( At Qb -200 Ml / Min & Qd 500 Ml / Min ) 140-160 4. Effective Surface Area ( M2 ) 0.5-0.9 5. Blood Priming Volume ( Ml ) 30-60 6. Koa Urea ( Ml / Min ) 300-700 7. Max. Dialysate Flow ( Qd ) 500 Ml-Min 8. Tmp Max ( Mmhg ) 600 9. Sterilisation Method €“ Inline Steam / Steam / Gamma 10. It Should Have Us Fda Or Ce Approval, Dialyzer ( Low / Middle Flux ) &Middot; 1.0 M2 To 1.1 M&Sup2; Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysulfone / Polyethersulfone / Helixone / Polyamix / Polynephrone Synthetic Membrane&Middot; €¢Surface Area 1.0 M&Sup2; / 1.1 M&Sup2;&Middot; €¢Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢Housing Material Should Be Have Polypropylene, Eco-Freindly And Light In Weight&Middot; Parameter Range Should Be As Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 5-15 2. Urea Clearance Ml / Min ( At Qb -200 Ml / Min & Qd 500 Ml / Min ) 170-190 3. Creatinine Clearance Ml / Min ( At Qb -200 Ml / Min & Qd 500 Ml / Min ) 160-180 4. Effective Surface Area ( M2 ) 1.00-1.10 5. Blood Priming Volume ( Ml ) 50-70 6. Koa Urea ( Ml / Min ) 300-700 7. Max. Dialysate Flow ( Qd ) 800 Ml-Min 8. Tmp Max ( Mmhg ) 600 9. Sterilisation Method €“ Inline Steam / Steam / Gamma 10. It Should Have Us Fda Or Ce Approval, Paediatric Dialyzer ( High Flux ) &Middot; 0.2 M2 To 0.4 M2 Hollow Fiber Dialyzer With Bio-Compatible Polysulfone / Polyethersulfone / Helixone / Polyamix / Polynephrone Synthetic Membrane&Middot; €¢Surface Area 0.2 M2 / 0.4M2&Middot; €¢Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢Housing Material Should Be Have Polypropylene, Eco-Freindly And Light In Weight&Middot; Parameter Range Should Be As Given Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 5-10 2. Urea Clearance ( Ml / Min ) ( At Qb -100 Ml / Min & Qd 300 Ml / Min ) 50-80 3. Creatinine Clearance ( Ml / Min ) ( At Qb -100 Ml / Min & Qd 300 Ml / Min ) 50-70 4. Effective Surface Area ( M2 ) 0.2-0.5 5. Blood Priming Volume ( Ml ) 15-30 6. Koa Urea ( Ml / Min ) 150-400 7. Max. Dialysate Flow ( Qd ) 500 Ml 8. Tmp Max ( Mmhg ) 600 9. Sterilisation Method €“ Inline Steam / Steam / Gamma 10. It Should Have Us Fda Or Ce Approval, Paediatric Dialyzer ( High Flux ) &Middot; 0.5 M2 To 0.9 M2 Hollow Fiber High Flux Dialyzer With Bio-Compatible €¢Polysulfone / Polyethersulfone / Helixone / Polyamix / Polynephrone Synthetic Membrane&Middot; €¢Surface Area 0.5 M2 To 0.9 M2&Middot; €¢Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢Housing Material Should Be Have Polypropylene, Eco-Freindly And Light In Weight&Middot; Parameter Range Should Be As Given Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 20-30 2. Urea Clearance ( Ml / Min ) ( At Qb -200 Ml / Min & Qd 500 Ml / Min ) 160-180 3. Creatinine Clearance ( Ml / Min ) ( At Qb -300 Ml / Min & Qd 500 Ml / Min ) 140-160 4. Effective Surface Area ( M2 ) 0.50-0.90 5. Blood Priming Volume ( Ml ) 30-50 6. Koa Urea ( Ml / Min ) 300-700 7. Max. Dialysate Flow ( Qd ) 500 & Tmp Max ( Mmhg ) 600 8. Sieving Coefficients: B2m ( 0.6 To 0.9 ) , Myoglobulin ( 0.1 To 0.5 ) , Albumin ( 0.001 To 0.1 ) 9. Sterilisation Method €“ Inline Steam / Steam / Gamma 10.It Should Have Us Fda Or Ce Approval, Dialyzer ( Low / Middle Flux ) &Middot; 1.4 M2 To 1.5 M2 Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysulfone / Polyethersulfone / Helixone / Polymix / Polynephrone Synthetic Membrane&Middot; €¢Surface Area 1.4 M2 / 1.5 M2&Middot; €¢Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢Housing Material Should Be Have Polypropylene, Eco-Freindly And Light In Weight&Middot; Parameter Range Should Be As Given Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 10-20 2. Urea Clearance Ml / Min ( At Qb -300 Ml / Min & Qd-500 Ml / Min ) 250 - 270 3. Creatinine Clearance Ml / Min ( At Qb -300 Ml / Min & Qd-500 Ml / Min ) 220-250 4. Effective Surface Area ( M2 ) 1.4-1.5 5. Blood Priming Volume ( Ml ) 70-100 6. Koa Urea ( Ml / Min ) 600-1000 7. Max. Dialysate Flow ( Qd ) 800 8. Tmp Max ( Mmhg ) 600 9. Sterilisation Method €“ Inline Steam / Steam / Gamma 10.It Should Have Us Fda Or Ce Approval, Dialyzer ( Low / Middle Flux ) 1.8 M2 To 1.9 M2 Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysulfone / Polyethersulfone / Helixone / Polymix / Polynephrone Synthetic Membrane €¢Surface Area 1.8 M2 / 1.9 M2&Middot; €¢Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢Housing Material Should Be Have Polypropylene, Eco-Freindly And Light In Weight&Middot; Parameter Range Should Be As Given Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 10-25 2. Urea Clearance ( Ml / Min ) ( At Qb -300 Ml / Min & Qd 500 Ml / Min ) 250-280 3. Creatinine Clearance ( Ml / Min ) ( At Qb -300 Ml / Min & Qd 500 Ml / Min ) 230-260 4. Effective Surface Area ( M2 ) 1.8-1.9 5. Blood Priming Volume ( Ml ) 90-120 6. Koa Urea ( Ml / Min ) 800-1000 7. Max. Dialysate Flow ( Qd ) 800 8. Tmp Max ( Mmhg ) 600 9. Sterilisation Method €“ Inline Steam / Steam / Gamma 10. It Should Have Us Fda Or Ce Approval, Dialyzer ( High Flux ) &Middot; 1.4 M2 To 1.5 M2 Hollow Fiber High Flux Dialyzer With Bio-Compatible Polysulfone / Polyethersulfone / Helixone / Polyamix / Polynephrone Synthetic Membrane&Middot; €¢Surface Area 1.4 M2 / 1.5 M2&Middot; €¢Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢Housing Material Should Be Have Polypropylene, Eco-Freindly And Light In Weight&Middot; Parameter Range Should Be As Given Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 35-70 2.Urea Clearance ( Ml / Min ) ( At Qb -300 Ml / Min & Qd-500 Ml / Min ) 250-280 3. Creatinine Clearance ( Ml / Min ) ( At Qb -300 Ml / Min & Qd 500 Ml / Min ) 240-270 4. Effective Surface Area ( M2 ) 1.4-1.5 5. Blood Priming Volume ( Ml ) 60-100 6. Koa Urea ( Ml / Min ) 800-1200 7. Max. Dialysate Flow ( Qd ) 1000 Ml-Min & Tmp Max ( Mmhg ) 600 8. Sieving Coefficients: B2m ( 0.6 To 0.9 ) , Myoglobulin ( 0.1 To 0.5 ) , Albumin ( 0.001 To 0.1 ) 9. Sterilisation Method €“ Inline Steam / Steam / ( Gamma 10. It Should Have Us Fda Or Ce Approval., Dialyzer: ( High Flux ) - Adult - 1.8 M2 To 1.9 M2 Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysulfone / Polyethersulfone / Helixone / Polyamix / Polynephrone Synthetic Membrane €¢Surface Area 1.8 M2 / 1.9 M2&Middot; €¢Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢Housing Material Should Be Have Polypropylene, Eco-Freindly And Light In Weight&Middot; Parameter Range Should Be As Given Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 50-80 2. Urea Clearance ( Ml / Min ) ( At Qb -300 Ml / Min & Qd-500 Ml / Min ) 270-290 3. Creatinine Clearance ( Ml / Min ) ( At Qb -200 Ml / Min ) 250-280 4. Effective Surface Area ( M2 ) 1.8-1.9 5. Blood Priming Volume ( Ml ) 80-120 6. Koa Urea ( Ml / Min ) 700-1000 7. Max. Dialysate Flow ( Qd ) 800 8. Tmp Max ( Mmhg ) 600 9. Sterilisation Method €“ Inline Steam / Steam / Gamma 10. It Should Have Us Fda Or Ce Approval, Dialyzer: ( High Flux / Hdf ) - Adult - 1.6 M2 To 1.7 M2 Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysulfone / Polyethersulfone / Helixone / Polymix / Polynephrone Synthetic Membrane&Middot; €¢ Surface Area 1.6M2 To 1.8M2 €¢ Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢ Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢ Housing Material Should Be Have Polypropylene, Eco-Freindly And Light In Weight&Middot; Parameter Range Should Be As Given Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 40 -80 2. Urea Clearance Ml / Min ( At Qb -300 Ml / Min ) 280 -290 3. Creatinine Clearance Ml / Min ( At Qb -300 Ml / Min ) 260 - 280 4. Effective Surface Area ( M2 ) 1.6 M2 To 1.7 M2 5. Blood Priming Volume ( Ml ) 90 -110 6. Koa Urea ( Ml / Min ) 1000 -1200 7. Max. Dialysate Flow ( Qd ) 1000 Ml-Min & Tmp Max ( Mmhg ) 600 8.Sieving Coefficients: B2m ( 0.6 To 0.9 ) , Myoglobulin ( 0.1 To 0.5 ) , Albumin ( 0.001 To 0.1 ) 9. Sterilisation Method €“ Inline Steam / Steam / Gamma 10. It Should Have Us Fda Or Ce Approval, Dialyzer: ( High Flux / Hdf ) - Adult - 2.0 M2 To 2.2 M2 Hollow Fiber Low / Middle Flux Dialyzer With Bio-Compatible Polysulfone / Polyethersulfone / Helixone / Polymix / Polynephrone Synthetic Membrane&Middot; €¢ Surface Area 1.9 M2 To 2.2 M2 €¢ Inline Steam Sterilised / Steam Sterilised / Gamma Sterilised&Middot; €¢ Effective Cleaning Of Clotting And Excellent Bio-Compatibility&Middot; €¢ Housing Material Should Be Polypropylene, Eco-Freindly And Light In Weight&Middot; Parameter Range Should Be As Given Below 1. U. F. Coefficient ( Ml / Hr X Mm Hg ) 60-100 2. Urea Clearance Ml / Min ( At Qb -300 Ml / Min ) 280 -295 3. Creatinine Clearance Ml / Min ( At Qb -300 Ml / Min ) 270-280 4. Effective Surface Area ( M2 ) - 2.0 M2 To 2.2 M2 5. Blood Priming Volume ( Ml ) 100 -130 6. Koa Urea ( Ml / Min ) -1300 -1500 7. Max. Dialysate Flow ( Qd ) 1000 Ml-Min & Tmp Max ( Mmhg ) 600 8.Sieving Coefficients: B2m ( 0.6 To 0.9 ) , Myoglobulin ( 0.1 To 0.5 ) , Albumin ( 0.001 To 0.1 ) 9. Sterilisation Method €“ Inline Steam / Steam / Gamma 10. It Should Have Us Fda Or Ce Approval, Av Bloodline Set Post Pump- Hd Machine ( Adult ) Av Bloodline Set - Hd Machine ( Adult ) 1 ) Bloodline Tube Material: Medical Grade Pvc Tubing 2 ) Sterilization: Eto / Gamma 3 ) Accessories-: ( All Must Be Present ) €¢ Patient Connector €¢ Ergonomic Grip On The Rotating Part To Ensure Secure Connection €¢ Easy To Remove Protective Caps €¢ Dialyser Connector €¢ Arterial & Venous Pressure Line Includes Transducer Protectors With Integrated Inspection Windows €¢ Luer-Lock Male / Female, Drip Chamber €¢ Injection Site With Large Finger Guard Clamp Colour Coded, Heparin Line With Luer-Lock Female Adapter With Protecting Cap & Easy To Remove Paper Tape €¢ Arterial Bubble Catcher €¢ Venous Bubble Catcher With Infusion Line ( Micron Filter Will Be Preferable ) €¢ Recirculation Connector 4 ) Parameters €¢ Inner Diameter Of Venous Bubble Catcher 22 Mm €¢ Pump Segment: 6.2 To 6.5 Mm €¢ Filling Volume : 150-180 Ml, Av Bloodline Set Post Pump - Hd Machine ( Adult ) 1 ) Bloodline Tube Material: Medical Grade Pvc Tubing 2 ) Sterilization: Eto / Gamma 3 ) Accessories-: ( All Must Be Present ) €¢ Patient Connector €¢ Ergonomic Grip On The Rotating Part To Ensure Secure Connection €¢ Easy To Remove Protective Caps €¢ Dialyser Connector €¢ Arterial & Venous Pressure Line Includes Transducer Protectors With Integrated Inspection Windows €¢ Luer-Lock Male / Female, Drip Chamber €¢ Injection Site With Large Finger Guard Clamp Colour Coded, Heparin Line With Luer-Lock Female Adapter With Protecting Cap & Easy To Remove Paper Tape €¢ Arterial Bubble Catcher €¢ Venous Bubble Catcher With Infusion Line ( Micron Filter Will Be Preferable ) €¢ Recirculation Connector 4 ) Parameters €¢ Inner Diameter Of Venous Bubble Catcher 22 Mm €¢ Pump Segment: 8.0 Mm €¢ Filling Volume : 150-180 Ml L, Av Bloodline Set Post Pump - Hd Machine ( Paediatric ) 1 ) Bloodline Tube Material: Medical Grade Pvc Tubing 2 ) Sterilization: Eto / Gamma 3 ) Accessories-: ( All Must Be Present ) €¢Patient Connector €¢ Ergonomic Grip On The Rotating Part To Ensure Secure Connection €¢ Easy To Remove Protective Caps €¢ Dialyser Connector €¢ Arterial & Venous Pressure Line Includes With Transducer Protectors Integrated Inspection Windows €¢ Luer-Lock Male / Female, Drip Chamber €¢ Injection Site With Large Finger Guard Clamp Colour Coded, Heparin Line With Luer-Lock Female Adapter With Protecting Cap & Easy To Remove Paper Tape €¢ Arterial Bubble Catcher €¢ Venous Bubble Catcher With Micron Filter €¢ Drainage Bag €“ One Way / Two Way, €¢ Recirculation Connector 4 ) Parameters €¢ Inner Diameter Of Venous Bubble Catcher 22 Mm €¢ Pump Segment: 6.2 To 6.5 Mm €¢ Filling Volume : 100-120Ml, Av Bloodline Set - Hd Machine ( Baby ) 1 ) Bloodline Tube Material: Medical Grade Pvc Tubing 2 ) Sterilization: Eto / Gamma 3 ) Accessories-: ( All Must Be Present ) €¢Patient Connector €¢ Ergonomic Grip On The Rotating Part To Ensure Secure Connection €¢ Easy To Remove Protective Caps €¢ Dialyser Connector €¢ Arterial & Venous Pressure Line Includes With Transducer Protectors Integrated Inspection Windows €¢ Luer-Lock Male / Female, Drip Chamber €¢ Injection Site With Large Finger Guard Clamp Colour Coded, Heparin Line With Luer-Lock Female Adapter With Protecting Cap & Easy To Remove Paper Tape €¢ Venous Bubble Catcher With Micron Filter €¢ Drainage Bag €“ One Way, Two Way, €¢ Recirculation Connector 4 ) Parameters €¢ Inner Diameter Of Venous Bubble Catcher 22 Mm €¢ Pump Segment: 6.2 To 6.5 Mm €¢ Filling Volume : 50-60 Ml, Av Bloodline Set - Hdf Machine ( Adult ) 1 ) Bloodline Tube Material: Medical Grade Pvc Tubing 2 ) Sterilization: Eto / Gamma 3 ) Accessories-: ( All Must Be Present ) €¢Patient Connector €¢ Ergonomic Grip On The Rotating Part To Ensure Secure Connection €¢ Easy To Remove Protective Caps €¢ Dialyser Connector €¢ Transducer Protectors With Integrated Inspection Windows, €¢ Luer-Lock Male / Female, Drip Chamber €¢ Injection Site With Large Finger Guard Clamp Colour Coded, Heparin Line With Luer-Lock Female Adapter With Protecting Cap & Easy To Remove Paper Tape €¢ Air Free Arterial Pressure Line €¢ Venous Bubble Catcher With Micron Filter €¢ Safe Line For Online Therapy €¢ Recirculation Connector 4 ) Parameters €¢ Inner Diameter Of Venous Bubble Catcher 22 Mm €¢ Pump Segment: 8.0 Mm €¢ Filling Volume : 130-140 Ml €¢It Should Be Compatible With 5008 Hdf Machine., Av Bloodline Set - Hdf Machine ( Paediatric ) 1 ) Bloodline Tube Material: Medical Grade Pvc Tubing 2 ) Sterilization: Eto / Gamma 3 ) Accessories-: ( All Must Be Present ) €¢ Patient Connector €¢Ergonomic Grip On The Rotating Part To Ensure Secure Connection €¢ Easy To Remove Protective Caps €¢ Dialyser Connector €¢ Transducer Protectors With Integrated Inspection Windows, €¢ Luer-Lock Male / Female, Drip Chamber €¢ Injection Site With Large Finger Guard Clamp Colour Coded, Heparin Line With Luer-Lock Female Adapter With Protecting Cap & Easy To Remove Paper Tape €¢ Air Free Arterial Pressure Line €¢ Venous Bubble Catcher With Micron Filter €¢ Safe Line For Online Therapy €¢ Recirculation Connector 4 ) Parameters €¢ Inner Diameter Of Venous Bubble Catcher 22 Mm €¢ Pump Segment: 8.0 Mm €¢ Filling Volume : 100-110 Ml €¢It Should Be Competable With 5008S Hdf Machine., Acid Concentration Part A * €¢ Dilution : 35X , Composition : ( Each 1 Ltr. Of Liquid Concentrate Contains ) €¢ Sodium Chloride I.P 210.0 Gm , Sodium 138.35, Potasium Chloride I.P 5.2 Gm, Potassium 2.0 , Calcium Chloride I.P 8.0 Gm , Calcium 1.55 , Magnesium Chloride I.P 2.7 Gm , Magnesium 0.38 , Acetic Acid, Glacial I.P 6.3 Gm , Bicarbonate 32.7, Purified Water I.P Q.S. , Chloride 108.5 , Acetate 3.0 €¢It Should Have Fda, Iso, Gmp / Whogmp / Copp Approval., Acid Concentration Part A ( K+ Free ) * €¢ Dilution : 35X , Composition : ( Each 1 Ltr. Of Liquid Concentrate Contains ) €¢ Sodium Chloride I.P 210.0 Gm , Sodium 137.60 , Calcium Chloride I.P 8.0 Gm, Calcium 1.55 , Magnesium Chloride I.P 2.7 Gm , Magnesium 0.38 , Acetic Acid, Glacial I.P 6.3 Gm , Bicarbonate 32.0 , Purified Water I.P Q.S. , Chloride 106.4, Acetate 3.0 €¢ It Should Have Fda, Iso, Gmp / Whogmp / Copp Approval., Acid Concentration Part A ( With Dextrose ) * €¢ Dilution : 35X , Composition : ( Each 1 Ltr. Of Liquid Concentrate Contains ) €¢ Sodium Chloride I.P 210.0 Gm , Sodium 138.35 , Potassium Chloride I.P 5.2 Gm, Potassium 2.0 , Calcium Chloride I.P 8.0 Gm , Calcium 1.55 , Magnesium Chloride I.P 2.7 Gm , Magnesium 0.38 , Acetic Acid, Glacial I.P 6.3 Gm , Bicarbonate 32.7, Dextrose Monohydrate I.P 38.7 Gm , Chloride 108.5 , Purified Water I.P Q.S., Acetate 3.0 , Dextrose 5.58 ( 1G / L ) . €¢ It Should Have Fda, Iso, Gmp / Whogmp / Copp Approval., Avf Needle €¢ 16G / 17G 1 Stainless Steel Ss304 Cannula With Back Eye €¢ Concave-Convex Embossed Wings For Secure Grip €¢ Luer Lock Hub For Secure Connection To Blood Tubing Set €¢ Gamma Sterilised / Eto Sterilised €¢ Colour Coded Wings For Gauze Sizes €¢ It Should Have Us Fda Or Ce Approval &Middot; Twin Packing, Endotoxin Filter €¢ It Should Be Fixed To Fresenius H.D. Machine For Producing Ultrapure Dialysate €¢ It Should Have Us Fda Or Ce Approval, Endotoxin Filter €¢ It Should Be Fixed To Nipro H.D. Machine For Producing Ultrapure Dialysate €¢ It Should Have Us Fda Or Ce Approval, Dry Bicarbonate Concentrate Powder Cartridge ( 650Gm ) €¢ To Be Fixed To Fresenius H.D. Machine ( 4008S Ng & 5008S ) To Produce Inline Bicarbonate Solution Without Manual Mixing €¢Dry Bicarbonate Should Be Compatible To Dilution Ratio 1+34. €¢Dry Bicarbonate Should Competable To Part A With ( K Free, K2, K3, K4 Dextrose, Without Dextrose ) . €¢Dry Bicarbonate Packing Material Should Be Environment Friendly. ( Pp Material Preferable ) €¢ It Should Have Us Fda Or Ce Approval., Dry Bicarbonate Concentrate Powder Cartridge ( 650Gm ) €¢ To Be Fixed To Nipro Surdial 55 Plus To Produce Inline Bicarbonate Solution Without Manual Mixing Dry Bicarbonate Should Be Compatible To Dilution Ratio 1+34. €¢Dry Bicarbonate Should Competable To Part A With ( K Free, K2, K3, K4 Dextrose, Without Dextrose ) . €¢Dry Bicarbonate Packing Material Should Be Environment Friendly. ( Pp Material Preferable ) €¢ It Should Have Us Fda Or Ce Approval, Cold Disinfectant For H.D / Hdf Machine / Water Treatment System €¢ Composition: Peracetic Acid ( 3 To 5 % ) , Hydrogen Peroxide. ( 15-25 % ) , Acetic Acid ( 1-5% ) €¢ It Should Have Microbiocidal, Bactericidal, Viral Inactivating ( Hbsag, Hcv, Hiv, Sars Cov-2 ) Infection And Fungicidal Activity €¢ It Should Have Material Safety Data Sheet&Middot; €¢ It Should Have Us Fda Or Ce Approval., Hot Disinfectant For H.D / Hdf Machine / Water Treatment System 1. Hot Disinfectant 100 Gm Should Contain 21G Citric Acid 1-Hydrate; Lactic Acid, Malic Acid 2.Composition: Citric Acid ( 20-40% ) , Lactic Acid ( 1-5% ) , Malic Acid ( 1-5% ) 3. It Should Have Microbiocidal, Bactericidal, Viral Inactivating ( Hbsag, Hcv, Hiv, Sars Cov-2 ) Infection And Fungicidal Activity 4.Disinfectant For Chemo-Thermal Disinfection Of Haemodialysis Machines €¢ Ph Value 1.7 To 2.0 €¢ Excellent Removal Of Limescale , Disinfection And Decalcification In One Process €¢ Active Ingredients Composed Of Natural Substances €¢ Biodegradable , Odourless , Free From Colouring Additives €¢ Disinfectant Much Certify & Ensure The Durability Of Internal Tubing Of Existing Hd Machine .Also Adding Longevity To The Machine Shelf Life. 5.It Should Have Material Safety Data Sheet&Middot; 6.It Should Have Us Fda Or Ce Approval., Regeneration Salt Tablet 1. Non Iodised Sodium Chloride 2. Diameter- 2-2.5 Cm 3. En14805 Typ1 4. En 973 Typ A 5. Of The Codex Alimentarius And The Nf -Standard 6. 25 Kg Bag 7. Compatible With Water Treatment System, Double Lumen Dialysis Catheter 11.5-12 Fr. X 13-13.5 Cm Curved Extension €¢ Radio Opaque 3Rd Generation Polyurethane Material Indwelling Catheter With Transparent Silicone Extension Tube To Visualize Fluids And Rotatable Suture Wing, It Should Have Accessories As Below €¢ Guide Wire Size 0.95Mm Dia X 70 Cm, Straight Soft Tip On One End And J-Tip On Other With Advancer €¢ 1 Introducer Needle 17G-18G X 6.5Cm €¢ 2 Vessel Dilator 10 Fr X 15 Cm & 12 Fr X 15 Cm , €¢ 2 Injection Cap, €¢ 1 Transparent Dressing €¢ Usfda Certification Of Entire Set, Double Lumen Dialysis Catheter 11.5-12 Fr. X 15-16 Cm Curved Extension €¢ Radio Opaque 3Rd Generation Polyurethane Material Indwelling Catheter With Transparent Silicone Extension Tube To Visualize Fluids And Rotatable Suture Wing, It Should Have Accessories As Below €¢ Guide Wire Size 0.95Mm Dia X 70 Cm, Straight Soft Tip On One End And J-Tip On Other With Advancer €¢ 1 Introducer Needle 17G-18G X 6.5Cm €¢ 2 Vessel Dilator 10 Fr X 15 Cm & 12 Fr X 15 Cm , €¢ 2 Injection Cap, €¢ 1 Transparent Dressing €¢ Usfda Certification Of Entire Set, Double Lumen Dialysis Catheter 11.5-12 Fr. X 13-13.5 Cm Straight Extension €¢ Radio Opaque 3Rd Generation Polyurethane Material Indwelling Catheter With Transparent Silicone Extension Tube To Visualize Fluids And Rotatable Suture Wing, It Should Have Accessories As Below €¢ Guide Wire Size 0.95Mm Dia X 70 Cm, Straight Soft Tip On One End And J-Tip On Other With Advancer €¢ 1 Introducer Needle 17G-18G X 6.5Cm €¢ 2 Vessel Dilator 10 Fr X 15 Cm & 12 Fr X 15 Cm , €¢ 2 Injection Cap, €¢ 1 Transparent Dressing €¢ Usfda Certification Of Entire Set, Double Lumen Dialysis Catheter 11.5-12 Fr. X 15-16 Cm Straight Extension €¢ Radio Opaque 3Rd Generation Polyurethane Material Indwelling Catheter With Transparent Silicone Extension Tube To Visualize Fluids And Rotatable Suture Wing, It Should Have Accessories As Below €¢ Guide Wire Size 0.95Mm Dia X 70 Cm, Straight Soft Tip On One End And J-Tip On Other With Advancer €¢ 1 Introducer Needle 17G-18G X 6.5Cm €¢ 2 Vessel Dilator 10 Fr X 15 Cm & 12 Fr X 15 Cm , €¢ 2 Injection Cap, €¢ 1 Transparent Dressing €¢ Usfda Certification Of Entire Set, Double Lumen Dialysis Catheter 11.5-12 Fr. X 19-20 Cm Straight Extension €¢ Radio Opaque 3Rd Generation Polyurethane Material Indwelling Catheter With Transparent Silicone Extension Tube To Visualize Fluids And Rotatable Suture Wing, It Should Have Accessories As Below €¢ Guide Wire Size 0.95Mm Dia X 70 Cm, Straight Soft Tip On One End And J-Tip On Other With Advancer €¢ 1 Introducer Needle 17G-18G X 6.5Cm €¢ 2 Vessel Dilator 10 Fr X 15 Cm & 12 Fr X 15 Cm , €¢ 2 Injection Cap, €¢ 1 Transparent Dressing €¢ Usfda Certification Of Entire Set, Double Lumen Dialysis Catheter 8 Fr. X 9-12 Cm Straight / Curved Extension €¢ Radio Opaque 3Rd Generation Polyurethane Material Indwelling Catheter With Transparent Silicone Extension Tube To Visualize Fluids And Rotatable Suture Wing, It Should Have Accessories As Below €¢ Guide Wire Size 0.64 Mm Dia X 70 Cm, Straight Soft Tip On One End And J-Tip On Other With Advancer €¢ 1 Introducer Needle 19G X 3.8Cm, €¢ Vessel Dilator 9 Fr X 12 Cm, €¢ 2 Injection Cap, €¢ 1 Transparent Dressing €¢ Usfda Certification Of Entire Set, Triple Lumen Dialysis Catheter 12 Fr. X 13-16 Cm Curved Extension €¢ Radio Opaque 3Rd Generation Polyurethane Material Indwelling Catheter With Transparent Silicone Extension Tube To Visualize Fluids And Rotatable Suture Wing, It Should Have Accessories As Below €¢ Guide Wire Size 0.95Mm Dia X 70 Cm, Straight Soft Tip On One End And J-Tip On Other With Advancer €¢ 1 Introducer Needle 17G-18G X 6.5Cm €¢ 2 Vessel Dilator 10 Fr X 15 Cm & 12 Fr X 15 Cm , €¢ 2 Injection Cap, €¢ 1 Transparent Dressing €¢ Usfda Certification Of Entire Set, Plasma Filter : ( 0.3 M2 To 0.4 M2 ) Hollow Fiber Plasma Filter With Excellent Bio-Compatibility Performance / Technical Data Should Be As Given Below : €¢ Inner Lumen Diameter ( &Micro;M ) : 250 To 350 €¢ Wall Thickness ( &Micro;M ) : 50 To 150 €¢ Filtrate Flow ( Ml / Min ) : 05 To 95 €¢ Blood Flow ( Ml / Min ) : 50 To 200 €¢ Effective Surface Area ( M2 ) : 0.2 To 0.4 €¢ Priming Volume ( Ml ) : 25 - 45 €¢ Tmp Max ( Mmhg ) : 50 - 150 €¢ Sieving Coefficients For Molecules Up To 1-2 Million Dalton : 0.9 To 1 €¢ Sterilisation Method €“ Inline Steam / Steam / Gamma €¢ Membrane Material- Polysulfone / Polypropylene / Polyethersulfone / Helixone / Polynephrone Synthetic Membrane&Middot; €¢ It Should Have Us Fda Or Ce Approval, Plasma Filter : ( 0.5 M2 To 0.6 M2 ) Hollow Fiber Plasma Filter With Excellent Bio-Compatibility Performance / Technical Data Should Be As Given Below : €¢ Inner Lumen Diameter ( &Micro;M ) : 250 To 350 €¢ Wall Thickness ( &Micro;M ) : 50 To 150 €¢ Filtrate Flow ( Ml / Min ) : 05 To 95 €¢ Blood Flow ( Ml / Min ) : 50 To 200 €¢ Effective Surface Area ( M2 ) : 0.3 To 0.6 €¢ Priming Volume ( Ml ) : 45 - 75 €¢ Tmp Max ( Mmhg ) : 50 - 150 €¢ Sieving Coefficients For Molecules Up To 1-2 Million Dalton : 0.9 To 1 €¢ Sterilisation Method €“ Inline Steam / Steam / Gamma €¢ Membrane Material- Polysulfone / Polyethersulfone / Helixone / Synthetic / Polynephrone Membrane&Middot; €¢ It Should Have Us Fda Or Ce Approval, Crrt Replacement Solution Bag 5- Litre Solution ( Regional Citrate Anticoagulation ) Crrt Solution Should Contain: €¢ Ph: 7 To 8 €¢ Sodium: ( Mmol / L ) : 135 To 140 Mmol / L €¢ Chloride: ( Mmol / L ) : 85 To 110 €¢ Citrate: ( Mmol / L ) : 18 €¢ Storage Conditions: 04&Deg;C To 30&Deg;C €¢ Packaging Fluid Bag Material: Pvc Or Pvc Free Bag €¢ Self Life: 12 To 24 Months €¢ After Mixing Both Compartment ( Sl ) : 24 To 48 Hours €¢ Volume: 5 Litre Bag €¢ Should Have Us Fda Or Ce Approval, Crrt Solution Bag 5- Litre Solution ( Calcium Free ) Crrt Solution Should Contain: €¢ Ph: 7 To 8 €¢ Sodium: ( Mmol / L ) : 133 To 145 €¢ Potassium: ( Mmol / L ) : 0 To 4 €¢ Calcium ( Mmol / L ) : 0 €¢ Glucose ( Mmol / L ) : 0-5.5 €¢ Bicarbonate: ( Mmol / L ) 18 To 22 €¢ Chloride: ( Mmol / L ) : 105 To 120 €¢ Magnesium: ( Mmol / L ) 0.5 To 0.1 €¢ Phosphate ( Mmol / L ) : 1 To 1.5 €¢ Storage Conditions: 04&Deg;C To 30&Deg;C €¢ Packaging Fluid Bag Material: Pvc Or Pvc Free Bag €¢ Self Life: 12 To 24 Months €¢ After Mixing Both Compartment ( Sl ) : 24 To 48 Hours €¢ Volume: 5 Litre Bag €¢ Should Have Us Fda Or Ce Approval, Crrt Solution Bag 5- Litre Solution Crrt Solution Should Contain: €¢ Ph: 7 To 8 €¢ Sodium: ( Mmol / L ) 135 To 145 €¢ Potassium: ( Mmol / L ) 0 To 4 €¢ Calcium: ( Mmol / L ) 0 To 1.5 €¢ Bicarbonate: ( Mmol / L ) 32 To 35 €¢ Chloride: ( Mmol / L ) 108 To 115 €¢ Lactate: ( Mmol / L ) 0 To 3 €¢ Magnesium: ( Mmol / L ) 0.5 €¢ Glucose: ( Mmol / L ) - 0 To 5.5 €¢ Buffer: Lactate / Bicarbonate €¢ Storage Conditions: 04&Deg;C To 30&Deg;C €¢ Packaging Fluid Bag Material Should Be Envirment Friendly. ( Pvc & Plasticizer Free Bag Is Desirable ) €¢ Self Life: 12 To 24 Months €¢ After Mixing Both Compartment ( Sl ) : 24 To 48 Hours €¢ Volume: 5 Litre Bag €¢ Should Have Us Fda Or Ce Approval, Crrt Haemofilter With Complete Circuit ( Kit ) : M100 - Adult €¢ Compatible To Prizmaflex Crrt Machine €¢ Kit Should Contain Haemofilter And Complete Circuit For Crrt Therapy. €¢ Should Have Us Fda Or Ce Approval €¢ Disposable, Extracorporeal Circuit Consist Of A An 69 Hf Hollow Fiber ( An69 -Acrylonitrile And Sodium Methallyl Sulfonate Copolymer ) Intended For Use In The Following Veno-Venous Therapies: Scuf, Cvvh, Cvvhd, Cvvhd. The Set Is Permanently Connected To A Blood Line, Blood Return Line, A Dialysate Inlet Line And An Effluent Outlet Line. The Fluid Pathways Of The Set Are Sterile And Nonpyrogenic. The Set Is To Be Used For Patients Who Have Acute Renal Failure, Fluid Overload, Or Both., Crrt Haemofilter With Complete Circuit ( Kit ) : M60 - Paediatric €¢ Compatible To Prizmaflex Crrt Machine €¢ Kit Should Contain Haemofilter And Complete Circuit For Crrt Therapy. €¢ Should Have Us Fda Or Ce Approval €¢ Disposable, Extracorporeal Circuit Consist Of A An 69 Hf Hollow Fiber ( An69 -Acrylonitrile And Sodium Methallyl Sulfonate Copolymer ) Intended For Use In The Following Veno-Venous Therapies: Scuf, Cvvh, Cvvhd, Cvvhdf. . The Set Is Permanently Connected To A Blood Line, Blood Return Line, A Dialysate Inlet Line And An Effluent Outlet Line. The Fluid Pathways Of The Set Are Sterile And Nonpyrogenic.. Set Is To Be Used For Patients ( Minimal Patient Weight 11 Kg ) Who Have Acute Renal Failure, Fluid Overload, Or Both., Crrt Haemofilter With Complete Circuit ( Kit ) : Hf20 - Paediatric €¢ Compatible To Prizmaflex Crrt Machine €¢ Kit Should Contain Haemofilter And Complete Circuit For Crrt Therapy. €¢ Should Have Us Fda Or Ce Approval €¢ Disposable, Extracorporeal Circuit Consist Of A Paes ( Polyarylethersulfone ) Hollow Fiber Haemofilter / Dialyzer Intended For Use In The Following Veno-Venous Therapies: Scuf, Cvvh, Cvvhd, Cvvhdf. The Set Is Permanently Connected To A Blood Line, Blood Return Line, A Dialysate Inlet Line And An Effluent Outlet Line. The Fluid Pathways Of The Set Are Sterile And Non-Pyrogenic . The Set Is To Be Used For Patients ( Minimal Patient Weight ≫8 Kg ) Who Have Acute Renal Failure, Fluid Overload, Or Both., Crrt Haemofilter With Complete Circuit ( Kit ) : Oxiris €¢ Compatible To Prizmaflex Crrt Machine €¢ Kit Should Contain Haemofilter And Complete Circuit For Crrt Therapy. €¢ Should Have Us Fda Or Ce Approval €¢Blood Purification Set Consists Of Acrylonitrile And Sodium Methallyl Sulfonate Copolymer + Polyethyleneimine ( Surface Treatment Agent ) +Heparin Grafted. This Set Should Be Intended For Use In The Following Veno-Venous Therapies: Scuf; Cvvh; Cvvhd; Cvvhdf. The Set Should Able To Permanently Connected To A Blood Line, Blood Return Line, A Dialysate Inlet Line And An Effluent Outlet Line. The Fluid Pathways Of The Set Should Be Sterile And Non-Pyrogenic., Crrt Haemofilter With Complete Circuit ( Kit ) Av 600 - Adult €¢ Compatible To Mutifiltrate Crrt Machine €¢ Kit Should Contain Haemofilter And Complete Circuit For Crrt Therapy. €¢ Should Have Us Fda Or Ce Approval, Crrt Haemofilter With Complete Circuit ( Kit ) For Av Pead- Paediatric €¢ Compatible To Mutifiltrate Crrt Machine €¢ Kit Should Contain Haemofilter And Complete Circuit For Crrt Therapy. €¢ Should Have Us Fda Or Ce Approval, Crrt Haemofilter With Complete Circuit ( Kit ) Av 1000 - Adult €¢ Compatible To Mutifiltrate Crrt Machine €¢ Kit Should Contain Haemofilter And Complete Circuit For Crrt Therapy. €¢ Should Have Us Fda Or Ce Approval, Crrt Haemofilter With Complete Circuit ( Kit ) Av 400 - Adult €¢ Compatible To Mutifiltrate Crrt Machine €¢ Kit Should Contain Haemofilter And Complete Circuit For Crrt Therapy. €¢ Should Have Us Fda Or Ce Approval, R-Hu Erythropoietin 4000 Iu Injection, R-Hu Erythropoietin 10000 Iu Injection, R-Hu Erythropoietin ( Lyophilized ) 4000 Iu Injection With Sterilized 2 Ml Syringe & 26G Needle 1 / 2, R-Hu Erythropoietin ( Lyophilized ) 10000 Iu Injection With Sterilized 2 Ml Syringe & 26G Needle 1 / 2, Heparin Sodium 25000 Iu ( 5 Ml ) Injection, Heparin Sodium 5000 Iu ( 5 Ml ) Injection, Ferric Carboxymaltose 50Mg / Ml, 2 Ml Vial For Inj. Ip, Ferric Carboxymaltose 50Mg / Ml, 10 Ml Vial For Inj. Ip, Ferric Carboxymaltose 50Mg / Ml, 20 Ml Vial For Inj. Ip, Inj Multivitamin ( 2 Ml ) €¢ Each Should Contain Methylcobalamin 1000-1500 Mcg, Pyridoxine Hydochloride 100Mg, Nicotinamide Ip 100Mg , D-Panthenol / Folic Acid, Benzyl Alcohol Ip 2.0% W / V, Levocarnitine Injection ( 1 Gm ) 5 Ml, Sodium Chloride 0.9% W / V I.P. 1000 Ml Injection*, Sodium Chloride 0.9% W / V I.P. 500 Ml Injection*, Dextrose 25% W / V I.P.100 Ml Injection*, Latex Medical Examination Gloves Medium Size ( Non-Sterile ) *, Haemodialysis On-Off Kit For Dialysis Procedure Convenience* &Middot;Protective Sheet ( Non Woven Plain Towel ) ( 30 Cm X 42 Cm ) - 1 Nos &Middot;Absorbent Towel ( Non Woven Towel Plastic Coated ( 30 Cm X 40 Cm ) - 1 Nos &Middot;Holder Cup 50 Ml - 1 Nos - Biodegradable Material &Middot;Holder Tray - 1Nos - Biodegradable Material &Middot;Gauze Swab 10 Cm X 10 Cm X 8Ply - 10 Nos &Middot;Cotton Balls 0.50 Gm - 4 Nos &Middot;Sterilized & Packing &Middot;Printing & Protective Pouch - 1 Nos ( Bidder Must Have 3 Years Of Manufacturing Experience Of Any Kind Of Medical Kit ) , Infusion Set ( Iv Set ) With Needle* €¢ Sharp Strong Piercing Spike, Manufactured Fromdehp Free Material-Non Toxic And Pyrogen Free, Cylindrical Collapsible Drip Chamber To Visualize The Flow Rate, 150Cm Long Super Smooth Kink Resistant Tubing With Efficient Roller Controller For Accurate And Unrestricted Flow, Needle 21X1&Frac12;€ For Smooth Flow Sterile ( Eto ) And Individually Packed., Blood Administration Set* €¢ Sharp Strong Piercing Non Vented Spike, Transparent And Flexible Double Drip Chamber With 200 Micron Filter, Kink Resistant Tubing With Efficient Roller Controller For Accurate And Unrestricted Flow, Flash Ball Injection Port / Self Sealing Latex Bulb For Medication, Needle 18X1&Frac12;€ For Smooth Flow, Safe Delivery In Sterile ( Eto ) Conditions., Disposable Syringe 20Ml Sterilized ( Virgin Material ) *, Sodium Hypochloride 6% *, Transparent Plastic Surgical Adhesive Tape Roll ( Width-1 Inch ) * Perforated, Porous Thus Breathable Polyethylene, Transparent Backing Coated With Pressure Sensitive, Hypoallergic Acrylate Adhesive. Size: 1 Inch X 9.14 Meter, Transparent Paper Surgical Adhesive Tape Roll ( Width-1 Inch ) * Non-Woven Viscose Rayon Porous Backing, Coated With Pressure Sensitive, Hypoalletgic Acrylate Adhesive. Size: 1 Inch X 9.14 Meter, Transparent Film Dressing - 10Cm X 12Cm* Single, Sterile, Transparent, Semi Permeable Thin Conformable Polyurethane Film ( Latex Free ) / Water, Virus And Bacteria Proof / Coated With Water Repellent Hypo-Allergic Pressure Sensitive Acrylate Adhesive. Bacterial And Viral Barrier Dressing, Barrier For Virus Size Of 27 Nm Or Larger, Dressing Remain Intact Without Leakage Size 10Cmx12cm, Transparent Film Dressing - 7Cm X 8.5Cm* Single, Sterile, Virus Proof, Polyurethane Film, Pressure Sensitive Acrylate Adhesive For Cvc Applications With Chg Gel Pad Which Has Unique Composition Of Water, Polymers And 2% Chlorhexidine Gluconate. Chlorhexidine Gluconate Dressing For Cvp 7Cm X 8.5Cm, Neomycin, Bacitracin And Sulphacetamide Sprinkling Powder ( 10 Mg ) * Neomycin Sulphate Ip ( 5 Mg ) , Bacitracin Ip ( 250 Units ) , Sulphacetamide Sodium Ip ( 60 Mg ) , Sterile Latex Surgical Gloves - 6, 6.5, 7, 7.5*, Pre And Post Surgical Skin Antisepsis.* Chlorhexidine Gluconate I.P. 10% V / V + Isopropyl Alcohol I.P. 70% V / V Bactericidal, Sporicidal, Fungicidal, Virucidal.

Key Value

Document Fees
INR 5000 /-
EMD
INR 20000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail