Military Engineer Services-MES has published Provision Of Retaining Wall For Strengthening Of Ht Electric Take Over Point And Provn Of Certain Sanctioned Works At Afs Dalhousie Provision Of Retaining Wall For Strengthening Of Ht Electric Take Over Point And Provn Of Certain Sanctioned Works At Afs D. Submission Date for this Tender is 11-11-2021. Wall construction Tenders in GE (AF) PATHANKOT Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-Nov-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-11-2021 |
Sl. No. | Item Description |
1 | Excavation over area n.exc 1.5m deep and getting out in hard/dense soil,complete all as specified and directed by Engrs-In-Charge. |
2 | Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exc 5o m and making good surface, work in soft disintergreted rock complete all as specified and directed by Engrs-In-Charge. |
3 | Returning, filling in, including back filling, spreading, levelling, watering and well ramming in layers not exc 25 cm in Hard/Dense soil,complete all as specified and directed by Engrs-In-Charge. |
4 | PCC 1:4:8 Type D2 40mm graded aggregate as in foundations, filling and mass concrete, complete all as specified and directed by Engrs-In-Charge. |
5 | PCC 1:3:6 Type C-1 20 mm graded aggregate as in wall or retaining wall, any thickness, size or shape including pilasters buttresses columns, pillars boundary pillars andposts (including caps and bases) complete all as specified and directed by Engr-in-charge. |
6 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc, verical or to batter, work in rough finished flat surfaces of concrete complete all as specified and directed by Engr-in-charge. |
7 | Supply and fixing ofPVC (SWR) pipes single socketed, in any length of 110mm bore with rubber ring joints, laid in walls , complete all as specified and directed by Engr-in-charge. |
8 | Broken stone or boulders hand packing ( any thickness), at back of walls over arches etc and raising (or lowering) to the required level complete all as specified and directed by Engr-in-charge. |
9 | Supply and fixing of4 mm dai galvanised steel wire 150x100 mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after fitting complete all as specified and directed by Engr-in-charge. |
10 | Mild steel work conforming to Fe 290 GdeE-165 as in angle iron posts with swan neck (horn) and struts fencing including cutting tops to shape also directed drilling holes notching for wire etc necessary drilling bolting as welding / riveting etc complete all as specifiedand directed by Engineer-in-Charge. |
11 | PCC 1:4:8, 100mm thicktype D-2 using (40mm gradedaggregate), as in sub base complete all as specified and directed by Engr-in-charge. |
12 | PCC 1:2:4 , 40mm thick type B-1using 20mm graded aggregate),finishedeven and smooth without using extra cement complete all as specified.as in floors complete all as specified and directed by Engr-in-charge. |
13 | Supply and fixing of rolled mild steel in roof trusses (framed) trussed, purlins, crane gantries, rails and framing (beam, tee, angle, channel or flat sections) Fe 410-w(Gde E 250) quality A including distance pieaces cleats etc complete all as specified and directed by Engr-in-charge. |
14 | Supply and fixing of MS plates plain or chequered square cut or notched forming holes drilled or welded any thickness complete all as specified and directed by Engr-in-charge. |
15 | Supply and fixing of pre -painted aluminum zinc coating GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof conering/cladding to wall, fixed with self tappting screws complete all as specified and directed by Engr-in-charge. |
16 | Supply and fixing of pre -painted aluminum zinc coating GI based plain steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof conering/cladding to wall, fixed with self tappting screwscomplete all as specified and directed by Engr-in-charge. |
17 | Preparation of new or priveously untreaterdsteel surfacesof any descriptionover 10cm width or girth, not otherwise desccribed applying two coats of synthetic enamel paint over a coat of redoxide complete all as specified and directed by Engr-in-charge. |
18 | Supply and fixing of 15mm GI tubes medium grade with all fittings & fixed complete to walls or ceilings or laid in floors complete all as specified and directed by Engr-in-charge. |
19 | All as per Item Nos-18 above but 20 mm diacomplete all as directed by Engr-in-Charge. |
20 | Cutting holes in Stone walls exceding half and n.exc one brickincement mortor for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as directed by Engr-in-Charge. |
21 | Supply and fixing in repairs long body bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixedcomplete all as directed by Engr-in-Charge. |
22 | Stainless steel sink 1mm thick bowl size 410x330x160mm fixed in repair including removing old sink with plush washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantileverbrackets and connecting unionto pipe complete all as directed by Engr-in-Charge. |
23 | Surfacesoildressing in hard/dense n.exc 15 cm deep and getting out complete all as specified and directed by Engr-in-charge. |
24 | Chequered cement concrete tiles 22 to 25mm thick, set jointed and pointed in neat cement slurry in floors, with grey cement and no pigment complete all as specified and directed by Engr-in-charge. |
25 | Screed bed or bedding layer of mortar 15mm thick in cement mortar (1:4) complete all as specifiedand directed by Engineer-in-Charge. |
26 | Removing excavated mtrl n.exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed by Engr-in-charge. |
27 | Supply and fixing ofFe 410-w(Gde E 250) quality A rolled mild steel in frame work as in doors or gates of angle other section with gusset plates, rails, braces, etc, complete drilled for fixing of steel sheeting or other covering.Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging doors fitting (exclusive of steel sheeting or other covering running rails and guides) and fixing complete all as specified and directed by Engr-in-charge. |
28 | Point wiring for one light point/ fan controlled by one switch on wall and surface on ceiling/roof with necessary fixing arrangements withPVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit/casing caping medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dollyand bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mountingfittings, door bell & bulkhead/telephone socket etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge |
29 | Sub main wiring with 2 Single core FRLS PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing in and including 20mm dia medium dutyPVC concealed conduit and conduit accessories and fittings. Including one single core green colour FRLS, PVC. Insulated unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity conductor upto common earth and connected to earth dolly complete all as specified & directed. (Note: Three run 4 Sqmm cable and one run conduit shall be measured as one run.) |
30 | Supply and fixing ofswitch piano flush type single pole one way 230 Volts 5/6 Ampcomplete all as specified and directed by Engineer-in-Charge. |
31 | Supply and fixing of ceiling rose surface bakelite 3 terminals of size 65x25mm complete all as specified and directed by Engr-in-charge. |
32 | Decorative ultra slimlinear LED lighting fixtures with extruded polycorbonate envirnmental friendly energy saver LEDlight fitting 20/22 watt (4"), 230 Volts, single tube mounting including LED Tube20/22Watt complete with industrial grade heavy duty electronic driver spring loaded rotory type lamp holder, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection 0.75 sqmmthree core copper cable from ceiling rose to led light fitting complete all as specified and directed by Engineer-in-Charge. |
33 | Supply and fixing ofsheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with IP-43 IK -09 protection double door complete withappropriate size bus barwith neutral and earth link bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed by Engineer-in-Charge. |
34 | Supply and fixing ofsheet metal enclosure for DB when MCBs to be used SPN 2 ways, 240 V with IP-43 IK -09 protection double door complete withappropriate size bus barwith neutral and earth link bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed by Engineer-in-Charge. |
35 | Supply and fixing of 1100 volts grade heavy duty cable PVC insulated aluminium staranded conductor, served with inner sheathed PVC tape and overall PVC sheathed in sevice connection suspended by insulating hangers not more than 01 mtrs apart including 4 mm suspention wire one twin core flat/circular cable of size 6 sqmm x 2 core complete all as specified and directed by Engineer-in-Charge. |
36 | Supply and fixingMCB SP 240 volt 6 to 32 Amps, 240 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed by Engineer-in-Charge. |
37 | All as per item No 36 above but SPN 16-32 ampscomplete all as specified and directed by Engineer-in-Charge. |
38 | Supply and fixing of sheet metal enclosure VTPN MCCB DB 12 way, 415 vo;ts (vetical type) with bus bar double door type IP 43 -IK 09 for DB when MCBs & MCCB 125 amps (as incomer) to be used, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wirescomplete all as specified and directed by Engineer-in-Charge. |
39 | Supply and fixing of sheet metal enclosurefor DB when MCBs to be used TPN, 4 way, 415 vo;ts (horizontal type) with 200 amps bus bar double door type suitable for TPN MCB/ 4 pole isolator, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wirescomplete all as specified and directed by Engineer-in-Charge. |
40 | Supply and fixing of sheet metal enclosurefor DB when MCBs to be used SPN, 4 way,240 vo;tswith 200 amps bus bar complete, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wirescomplete all as specified and directed by Engineer-in-Charge. |
41 | Supply and fixingMCB TP40 to 63 Amps,415 volt,having C-curve characteristics connected with suitable lugs complete all as specified and directed by Engineer-in-Charge. |
42 | All per item Nos 41 above but TPN 40-63 Amps 415 volts complete all as specified and directed by Engineer-in-Charge. |
43 | Supply and fixing ofMCCB 125 Amps, 3 Pole, 415V, 35KA complete all as specified and directed by Engineer-in-Charge. |
44 | Sub main wiring with four runs of single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 10 sqmm drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20/25 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc laid in concealed/surface position with one run of 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed by Engineer-in-Charge. |
45 | Sub main wiring with four runs of single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20/25 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc laid in concealed/surface position with one run of 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed by Engineer-in-Charge. |
46 | Supply and fixing ofcopper strip 20x3mm complete with saddles/ insulators made out of PVC or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints complete all as specified and directed by Engineer-in-Charge. |
47 | Flameproof concealed point wiring on wall and surface wiring on ceiling / roof with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as, bends, tee, elbow excludingjunction boxes etc including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for one light, fan point controlled by one switch Note : Junction boxes sahll be measured separately |
48 | All as per item No 47 above but for power point wiring with 2.5 SqmmPVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by Engineer-in-Charge. |
49 | Supply and fixing of 16 Amp flame proof weather proof switch Socket and plug combinedin LM 6 cable termination box, 250 V, 2P+ earth complete all as specified and directed by Engineer-in-Charge. |
50 | Supply and fixing of flame proof weather proof threaded type junction box LM 6 aluminium alloy complete all as specified and directed by Engineer-in-Charge. |
51 | Supply and fixing offlame proof weather proof metallic hose conduit 3/4 " dia300 mm long complete all as specified and directed by Engineer-in-Charge. |
52 | Supply and fixing offlameproof double compression brass cable gland 3/4" dia complete with nipples complete all as specified and directed by Engineer-in-Charge. |
53 | Supply and fixing ofFlame proof weather proof switch with cable termination in LM 6 aluminium alloy housing 16 Amp, single pole 250 voltscomplete all as specified and directed by Engineer-in-Charge. |
54 | Supply and fixing ofenergy efficientflame froof , heavy duty high speed exhaust fan 380 mm(15") sweep, with louver shutter, matel body rust proof inbuilt safety grill, single phase 230 volts 50 Hz AC,totally enclosed heavy duty motor with die cast alumn rotor mounted on two ball bearings complete with louvers & shutters,,including making circular holes suitable for fixing of 380mm sweep exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete and connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed complete all as specified and directed by Engineer-in-Charge. |
55 | Fluorescent tube light fitting, 1x36 watt flameproof type FLP-WP IP-65 made of aluminium alloy LM6 with electronic ballast, bipen holders, connector block etc complete with all accessories prewired and includidnt connecting up with twin core twisted flexiblecopper conductor cable with suitable sizecomplete all as specified and directed by Engineer-in-Charge. |
56 | Concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements withPVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dollyand bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mountingfittings, door bell & bulkhead/telephone socket etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge (a) one light point controlled by one switch |
57 | Supply and fixing of switch paino flush button type single pole one/two way / bell push 5 amps 240 voltscomplete all as specified and directed by Engr-In-Charge. |
58 | Supply and fix heavy duty exhaust fan AC single phase 230/240 V of size 300 mm sweep 1400 RPMwith louver & shutter including necessary grouting on wall complete and making good the wall surface after fixing of exhaust fan complete all as specified and directed by Engineer-in-Charge. |
59 | Earthing complete with copperearth plate electrode 600x600x3.15 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below ;normal ground level ) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to copper strip 20X3 mm as earth lead by means of bolts, nuts washers and check nutsof steel/GI duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light gradewith CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoaldust and common salt after mixing with BFC (Back Fill Compound) inadeqate quantity as recommended by the manufacturer oras diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel withwire mesh complete and all as specified and as directed by Engr-in-charge. (Note:- (i) If the desired earth resistance is not found within permissible limit shall be redone by the contractor at no extra cost.(ii) Cost of Copper strip 20x3 and 15mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item). |