As As To Amco Room And In Charge Book Room At Meenambakkam Under Age(I) Navy Chennai As As To Amco Room And In Charge Book Room At Meenambakkam Under Age(I) Navy Chennai, Chennai-Tamil Nadu

Military Engineer Services-MES has published As As To Amco Room And In Charge Book Room At Meenambakkam Under Age(I) Navy Chennai As As To Amco Room And In Charge Book Room At Meenambakkam Under Age(I) Navy Chennai. Submission Date for this Tender is 29-10-2021. Building Work Tenders in Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

29571181
Corrigendum : As As To Amco Room And In Charge Book Room At Meenambakkam Under Age(I) Navy Chennai As As To Amco Room And In Charge Book Room At Meenambakkam Under Age(I) Navy Chennai
Open Tender
Indian
Tamil Nadu
Chennai
29-10-2021

Tender Details

As As To Amco Room And In Charge Book Room At Meenambakkam Under Age(I) Navy Chennai As As To Amco Room And In Charge Book Room At Meenambakkam Under Age(I) Navy Chennai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.0 /-
Tender Value
INR 9.50 Lakhs /-

BOQ Items

Name of Work: AS & AS TO AMCO ROOM AND IN CHARGE BOOK ROOM AT MEENAMBAKKAM UNDER AGE(I) NAVY CHENNAI (Tender ID - 2021_MES_475026_2)
Sl. No. Item Description
1Dismantling wall and ceilingboards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed.
2M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 8mm thick high Pressure Non Asbestos Fiber Cement decorative Board (E-Board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof eith adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid all as specified and directed.
3Taking down shutters of any description exc 1 Sqm n exc 2 sqm each leaf
4Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Square metre each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified.
5All as per item above herein before but size exceeding 1.5 Square metre and not exceeding 4 Square metre each.
6M&L Cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in filling of steel chowkhatsand holdfast including necessary form work complete all as specified.
7S&F Anodised aluminium powder coated any colour as approved for ventilator frame and shutter , half fixed and half louvered type without sash bar , incuding 4 mm thick glass , necessary joining cleats , glazing clips , rubber packing , anodised aluminium snap beading ,screws etc and section weighing 0.55 kg/ Rm complete all as specified
8S&FAnodised aluminium powder coated any colour as approved window shutters, incl window frame with three track slidingtype, without sash bars including guide rollers as reqd nos, including 4mm thick glass necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings as required like suitable handle, star lock etc and section weighing 0.55kg/Rm completeallasspecifiedand directed (Note- Rate incl for providing slide or fix type mosquito proofing shutter and addl track if reqd)
9S&FAnodised aluminium powder coated any colour as approved Door shutters, inclframe with prelaminated board of 6 mm thick at bottom , without sash bars including guide rollers as reqd nos, including 4mm thick glass necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings as required like suitable handle, star lock etc and section weighing 0.55kg/Rm completeallasspecifiedand directed (Note- Rate incl for providing slide or fix type mosquito proofing shutter and addl track if reqd)
10S&F 4.8 mm thick sheet glass selected quality approved fixed in position in aluminium/iron/wooden frame work including rubber beading and pointing cleats/glazing with oil putty complete all as specified.
11S&F 6.3 mm thick sheet glassexc 0.5 sqm selected quality approved fixed in position in aluminium/iron/wooden frame work including rubber beading and pointing cleats/glazing with oil putty complete all as specified.
12M&L double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box , main body with stainless steel cover , governing pivot made of brass , other parts made of mild steel heavy duty and fixed.
13S&F in repair Aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with beading to wooden frames with aluminium wire staples as specified and directed.
14S&FAnodised aluminium frame for partions with one or more rebates incl joining cleat for fixing etc complete.
15S&F sheet glass 5.5 mm thick sheet glass,selected quality insquarenot exc. 0.50sqm in each pane all as specified.
16Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises.
17M&L Glazed ceramic tiles in vertical surface 300 X 450 X 7mm thickincuding rendering 10 mm thick cement mortar (1:4) to receive tiles in vertical surfaces all as specified set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified
18M&L Non-skid colour ceramic tiles 7 to 8 mm thick ( square/rectangular) area of each tiles exc 0.11 sqm but not exc 0.18 sqmas in floors includingscreed bed or bedding layers of 15 mm thick cement mortar (1:6) for laying floor finishes all as specified. set and jointed in cement slurry @ 3 Kg/Sqm and pointed in white or colour cement to match existing surfaces complete all as specified .
19M&L Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etcincludingscreed bed or bedding layers of 15 mm thick cement mortar (1:6) for laying floor finishes all as specified. all as specifiedset and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
20M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting/dado etcincuding rendering 10 mm thick cement mortar (1:4) to receive tiles in vertical surfaces , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
21Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. Complete all as specified and as directed.
22M&L fly ash Brick work with sub-class `B" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 Complete all as specified and as directed.
23M&L fly ashbrick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick wallin cement mortar 1:4 complete all as specified and as directed.
24M&L 10 mm thick CM plaster in CM(1:4) mixed withwater proofing compound @3% by weight of cement over while the padding concrete is still green complete all as specified and as directed.
25Supply only liquid water proofing compound
26M&L for rendering 15mm thick in cm 1:3 cement plaster on fair faces of brick or concrete surfaces finished even and smooth without using extra cement, with water proofing compound @3% by weight of cementcomplete all as specified.
27Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed.
28M&L Rendering/plastering, 10mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, using WPC, surfaces finished finished even and smoothwithout using extra cement complete all as specified. (WPC measured separately).
29S&F 19 mm dia Mild steel curtain rod powder coated with fixing side brackets, end cups, rings @ 10 Nosper running metre and fixed withPVC rawl plugs & steel screws as inrepairs complete all as specified.
30M&Lpreparation of new undecorated plastered surface of walls and applying two coat of colour distemper oil emulsion over one coat of primer on wall complete all as specified.
31M&L forcomplete removal of existing treatment and applying two coat of oil bound distemper (white or tinted) over a coat of whiting on wall complete all as directed.
32M&L providing PCC type B1 1:2:4 (20mm graded aggregate) as in hold fast fixing complete all as specified and directed by Engineer-in-Charge.
33S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks & similar work con-forming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
34M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
35M&L for removing loose dust partcies andsurface is wet approxmiate damp proof cleaning to be done and appying one coat of wall primer then applying two coats oftexture painting over the exisitng wall of desired pattern and proper application toolsas per design complete all as specified and directed by the Engr-in-charge.
36M&L preparation of old surfaces (plastered or unplastered) of walls including cornices by brooming down or steel wire brushes, scrapping down smoke soot moulds moss and efflorescent salts, trading oil cut greasy spots apply two coats of distemper oil emulsion with one coat of primer over one coat of wall putty on wall complete all as specified and directed by Engineer in Charge
37M&L for complete removal ofold treated/treatment removed surfaces of walland applying two coats of exterior weather proof emulsion (Colour as approved by AGE(I)) over a coat of primer over one coat of wall putty as approved all as specified and as directed.
38M&L for 8mm thick toughened glass with hatching design/ pattern and fitted to top and bottom hardwood chamfered or rounded fitted with cut and mitred beads for securing glass with necessary pivot hinge, cut outs and holes suitable for "H" handle (02 Nos for each side), backer rod, silicon sealant with ceiling bearing (including 02 Nos of locking arrangments) complete all as specified and directed by the Engr-in-charge.
39M&L double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box , main body with stainless steel cover , governing pivot made of brass , other parts made of mild steel heavy duty and fixed complete all as specified and as directed by Engineer in Charge.
40S&F 30mm thick flush shutters, soild core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer in Charge.
41S&F in repairs MS Sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia and 300mm long complete all as specified and directed by Engineer in Charge.
42S&F butt hinges, medium weight, cold rolled mild steel, and fixed of size 100mm complete all as specified and directed by Engineer in Charge.
43S&F in repairs 150mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed by Engineer in Charge.
44S&F in repair 150mm floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engineer in Charge.
45S&F anodized aluminium frame for doors, windows, ventilators,partitions with one or more rebates including joining cleat,clips for fixing etc. of size 50mm x 40mm x 1.5mm thick complete all as specified and directed by Engineer in Charge.
46S&F in repairs prelaminated particle board, 12mm thick, interior grade, prelaminated both sides with decorative choice laminations and other side balancing white lamination complete all as specified and directed by Engineer in Charge.
47M&L for preparation of old decorated plastered surfaces and applying one coat of colour distemper oil emulsion complete all as specified and as directed by the Engineer-in-Charge.
48M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed by the Engineer-in-Charge.
49Point wiring for One light point controlled by one switch, with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single coreFRLSdrawn with stove enamelled steel conduit of 20 mm dia,orasper is concealed FRLSwiring,along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roofexcluding Modular Metal flsh box and white cover palate with frame the switches, sockets, fan regulator etc as required suitable for Modular type fitting /fixture trll as specified and directed f
50All as per Sl item No. 49 but for One fan/Exhaustfanpoint controlled by one regulator / switch.
51All as per Sl item No. 49 but forOne3 pin socket outlet 5 amps socket on same board
52All as per Sl item No. 49 but for2.5 sqmm cable for one 3 pin socket outlet 15 amps on independent board with 2.5 sqmm cable as earthing conductar
53S&F for Modular Switch, 1 Way, 6A, 1 Module
54S&F for Modular Switch, 1 Way, 16A, 1 Module
55S&F Modular Socket, 6A, 2/3 pin combined, 2 Module
56S&F Modular Socket, 6A / 16A, 2/3 pin combined, 2 Module
57S&F for Modular White cover plate with frame, 4 Module
58S&F for Modular White cover plate with frame, 6 Module
59S&F for Modular Metal flush box, 4module
60S&F for Modular Metal flush box, 6 module
61M&L forceiling rose, 3 phase fire rated polycarbonate, isolated body
62S&F stepped type electronic fan regulator Modular type all as specified and directed by engineer in charge
63S&F for sub main Wiring for Circuit of size 2 x 6.0 sq.mm along with earth wire of size 1 x 4 sq.mm, Single Core, PVC insulated copper coductor (FRLS) Cable in concealed / surface / recessed PVCConduit
64S&F sheet metal enclosure powder coated single door outdoor typefor Distribution Board, SPN 12 way DB with Degree of ProtectionIP 54 , Detachable Gland Plate, Box Insertion Marks •,Circuit Identification Label •,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
65S&FMCB SPN 32- 63 A, B curveincluding , Disconnecting electric connections, completeall as specified and as directed.
66S&FMCB SP 06 A to 32 A, B curve including ,completeall as specified and as directed.
67S&F2X2 LED fitting,2500 lm ,6500 K suitable for Surface, Wall & Conduit mounting complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and lamp complete all as specified and directed internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and directed . Make :Philips RC380B LED34S-6500 G3 PSD OD or equivalent in Bajaj/ Crompton/ Havells
68S&F Ceiling fan sweep 1200 mm complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
69S&F air cooled split unit air conditioner electric driven single phase of inverter type, capacity of 2 TR.
70S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
71S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps