Repair / Maintenance Of Internal Electrical Wiring And Connected Works In Smq Area, Kasturi Hospital, Nsb Area And Pratab Nagar Area At Ins Shivaji, Lonavla Repair / Maintenance Of Internal Electrical Wiring And Connected Works In Smq Area, Kastur, GE (I) (NAVY) LONAVLA-Maharashtra

Military Engineer Services-MES has published Repair / Maintenance Of Internal Electrical Wiring And Connected Works In Smq Area, Kasturi Hospital, Nsb Area And Pratab Nagar Area At Ins Shivaji, Lonavla Repair / Maintenance Of Internal Electrical Wiring And Connected Works In Smq Area, Kastur. Submission Date for this Tender is 04-11-2021. Electrification Work Tenders in GE (I) (NAVY) LONAVLA Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

29570634
Corrigendum : Repair / Maintenance Of Internal Electrical Wiring And Connected Works In Smq Area, Kasturi Hospital, Nsb Area And Pratab Nagar Area At Ins Shivaji, Lonavla Repair / Maintenance Of Internal Electrical Wiring And Connected Works In Smq Area, Kastur
Open Tender
Indian
Maharashtra
GE (I) (NAVY) LONAVLA
04-11-2021

Tender Details

Repair / Maintenance Of Internal Electrical Wiring And Connected Works In Smq Area, Kasturi Hospital, Nsb Area And Pratab Nagar Area At Ins Shivaji, Lonavla Repair / Maintenance Of Internal Electrical Wiring And Connected Works In Smq Area, Kasturi Hospital, Nsb Area And Pratab Nagar Area At Ins Shivaji, Lonavla

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-11-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work:REPAIR / MAINTENANCE OF INTERNAL ELECTRICAL WIRING AND CONNECTED WORKS IN SMQ AREA, KASTURI HOSPITAL, NSB AREA AND PRATAB NAGAR AREA AT INS SHIVAJI, LONAVLA (8024 / E8)
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for issue under Schedule of credit and making good disturbed surfaces of walls, floors, etc.
2Taking down MCB DBs/ SFUs
3M & L for point wiring with 1.5 sq mm single core FRLS PVC insulated cable 1100 V grade with multistranded copper conductor drawn through PVCcasing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copperconductor as earth continuity conductor and connected to common earth dolly incl fabricated steelterminal box made out of 1.6 mm thick MS sheet concealed in the wall with 3 mm thick laminated sheet top cover / PVC Switch Board mounted on wallfor mounting the switches , socket outlets , fan regulators etc all as s specified and directed for following. (a) One light/Fan point controlled by one switch.
4All as per item no 3 above but One socket 3 pin outlet 5 amp on independent board.
5All as per item no 3 above but One 3 pin socket outlet 5 amp on the same board board with other switches.
6All as per item no 3 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
7All as per item no 3 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm.
8S&F in repairs switch piano flush type single pole one way 5 amp.
9S&F in repairs ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified.
10S&F in repairs switch socket combination 2 in 1, 3 pin 5/15 amp flush type..
11S&F in repairs switch socket combination 2 in 1,5 amp flush type.
12S&F in repairs socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type.
13S&F in repairs switch bell push, flush type 5 Amp.
14S&F in repairs bell, Multi music type AC, 230 Volts single pole.
15S&F in repairs fan regulator electronic step type complete all as directed by EIC at site
16S&F in repairsLED tube rod for LED Tube light fitting 18 Watt , complete with all accessories complete all as required at site and as directed by Engineer -in-Charge. Make : Cat No BLRB 20 CW LED of Bajaj or equivalent of Havell"s/Philips / Wipro
17S&F in repairsBattenfor LED Tube light 18 Watt fitting prewireed upto terminal block complete with all accessories and connecting up with twin core / .0076 flexible copper wire with and including LED tube light fixed on two nos PVC round / square mounting blocks complete all as required at site and as directed by Engineer -in-Charge. Make : Cat No BLRB DB 118 of Bajaj or equivalent of Havell"s/Philips / Wipro .
18S&F in repairs Surface mounted 36 watt 2 x 2 luminaire white powder coated CRCA housing with LEDs, Aluminium front frame with flat white high transmission acrylic cover complete with LEDs, driver and standard accessories including neccessary fixing arrangement complete all as required at site and as directed by Engineer -in-Charge. Cat No BCTBLR 36W LED FP CWof Bajaj or equivalent to Philips /CG.
19Supply & fix in repairs 45 W pressure die cast aluminium housing LEDBuilding light secondary optics IP 66 protectionincluding connection with two core twisted copper flexible cable, Make - Bajaj, Cat No - ENXT P 54L WH CR PC SD or equivalent make of Havells /Philips/CG
20Supply and fix in replacement of LED Tube light of 18/20 watt (4") with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:BajajCAT Part No BCLAB 20W WH LED P (4ft)or equivalent to CG/Philips/Wipro complete all as specified and directed .
21Supply and fix in replacement of LED Tube light of 10 watt (2") with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:BajajCAT Part NoBCLSB 10 WH (2ft)or equivalent to CG/Philips/Wipro complete all as specified and directed .
22S&F in replacement vertical type DB ,(VTPN) suitable for and including MCCB 4 pole, 125 amps, 16KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 4 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and boltincluding matching the existing surfaceall as specified and directed ,
23S&F in replacement MCB DB TPN 4 ways double door with 440 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed
24S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed
25S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed
26S&F in repairs MCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed
27S&F in repairs MCB C Curve SPN 32-63 amps, 240 Volts, Complete all as specified and directed.
28S&F in repairs MCB C Curve SP 6 to 32 amps single pole 240 Volts, Complete all as specified and directed.
29S&F in repairs MCB C Curve TPN 6-32 Amps , complete all as specified and directed.
30S&F in repairs MCB C Curve TPN 40-63 Amps , complete all as specified and directed.
31S&F in repairs MCCB FP 125 Amps 16 kA 415 V , wcomplete all as specified and directed.
32S&F in repairs MCCB FP 160 Amps 25 kA 415 V , with adjustable thermal and adjustable magnetic release, Complete all as specified and directed.
33S&F in repairs MCCB FP 200 Amps 25 kA 415 V , with adjustable thermal and adjustable magnetic release, Complete all as specified and directed.
34Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
35M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
36M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed.Note:- Four run of 6 sqmm wire and Two run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
37Supply and fix in repairs Triple pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto 32Apms
38Supply and fix in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto10/20 Apms
39M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
40Supply and fix new adore LED lamp 5 Watt confirming to Cat No LhLDeroemD9X005 of Havell"s or euivalent in Philips / Bajaj
41Supply and fix new adore LED lamp 9 Watt confirming to Cat No LhLDeueCnL8r009 of Havell"s or euivalent in Philips / Bajaj
42Supply and fix new adore LED lamp 15 Watt confirming to Cat No LhLDeueCnL9r015 of Havell"s or euivalent in Philips / Bajaj
43Dismantling the existing energy Meters, MCCB / MCB Distribution boards by disconnecting the eletric supply connection and refixing at new or same location after carrying out repairs / replacement , reconnecting complete all as directed by EIC at site.
44Supply and fix in repairs modular switch oneway 6 Amps, 1 module complete all as specified and as directed.
45Supply and fix in repairs modular socket6 Amps, 2/3 pin combined 2 module complete all as specified and as directed.
46Supply and fix in repairs modular socket 6 Amps/16 Amps, 2/3 pin combined 2 module complete all as specified and as dirceted.
47Supply and fix in repairs modular switch 1 way 16 Amps, 1 module complete all as specified and as directed.
48Supply and fix in repairs modular bell push 6 Amps, 1 module complete all as specified and as directed.
49Supply & fix LEDHighbay luminaire 100 Watt along with fixture, complete all as specified and directed at site.Make:BajajCAT Part No BGHBM 100W LED XEor equivalent to CG/Philips/Wipro complete all as specified and directed.
50Supply and fix in replacement Electronic ballast suitable for 1x36/40 Watt tube light fitting complete all as specified and as directed.
51Supply and fix in replacement Electronic ballast suitable for 1x18/20 Watt tube light fitting complete all as specified and as directed.
52Supply and fix in replacement Electronic ballast suitable for 1x28 Watt tube light fitting complete all as specified and as directed.