Municipal Corporation-MC has published Work Imp. Dev. Of Electrical Installation In Edmc Cremation Ground At Old Seemapuri And Leprosy Colony In Ward No. 28-E And 34-E Under Shahdara ( North ) Zone. Submission Date for this Tender is 21-10-2021. Electrical Maintenance Tenders in As per NIT Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating box type complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Wattb) Luminaries effucacy = 100 lumens/watt c) Power factor = 0.95 |
2 | S/I/T/C of Surface mounting CRCA housing 8WLED luminaire with acrylic cover diffuser with following specifications including fixing on existing wall/surface with connections as reqd.(a) Total system wattage = 8watt +/- 5%(b) Luminus effcacy >=95 lumans /watt. (c) Power Factor>=0.95 |
3 | SITC of 150 W LED Flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd with 5 year warranty.(a) Total system wattage =150watt +/- 5%.(b) Luminaire Efficacy>=100 Lm/w(c) Power Factor>=0.95(d) Protection Class- IP-66 |
4 | P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 2000x160x98mm (NS) complete with suitable arrangment for fixing of 2 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd.( Without MCB) |
5 | Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 0mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd. |
6 | Supplying and fixing following rating, double pole, (single phase and neutral),240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 Amp. |
7 | Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and 1.5 sq mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit inculding dismantling as required Group-C |
8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the exisiting surface/recessed steel/PVC conduit as required 3x2.5 sq mm |
9 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the exisiting surface/recessed steel/PVC conduit as required 3x6 sq mm |
10 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 5/6 amps switch |
11 | (b) 3 pin 5/6 A socket outlet |
12 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
13 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 20 mm |
14 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps |
15 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
16 | Supply of XLPE Insulated PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098 (Part-I) 1998 as required.(a) 2x25sqmm |
17 | (b) 2x10sqmm |
18 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
19 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
20 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required (a) 100 A, 16 KA,TPMCCB |
21 | (b) 125 A, 16 KA,TPMCCB |
22 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door |
23 | Supplying and fixing extra down rod of 20 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
24 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
25 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
26 | Supply & Fixing of phenolic laminated sheet3.00mm thick ISI Marked as reqd. |
27 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
28 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All type of soil 200 mm dia |
29 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.125 mm nominal size dia |
30 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge125 mm nominal size dia |
31 | Development of tube well with suitable capacity air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd.The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd. |
32 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia |
33 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts f required size complete. 150 mm dia |
34 | Providing and fixing Ball plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia |
35 | Supplying, lowering and fixing following size of G.I. Pipe (M- Class) i/c cutting threading on both sides etc ISI marked etc as reqd. (a) 25mm (Nominal Bore) |
36 | (b) 32mm (Nominal Bore) |
37 | S&F following sizes ofGI socket as reqd. (a) 25mm dia |
38 | (b) 32 mm dia. |
39 | S&F following sizes ofG.I. union as reqd. (a) 25mm dia |
40 | S& F following sizes ofGI Elbow as reqd. (a) 25mm dia |
41 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore. |
42 | Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin-charge. |
43 | Supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed, water filled, deep well submersible pumping set complete i/c connections etc as reqd. (a) Single phase 1.5 HP, having discharge of 72 LPM (approx.) at 49 M head. |
44 | Supplying and laying following sizes of insulated steel flexible safety rope for holding submersible pump set i/c clips etc as reqd.6 mm dia steel rope. |
45 | P and F following sizes of PVC insulated and PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. (a) 3 X 2.5 sq.mm. |
46 | Providing and laying cement concreat 1:2:4 mix for sanitary sealing of well at top of 450mmX 450mmX 500 mm deep from top comp as reqd. |
47 | Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd.1.5 H.P (Single Phase) |