Wapcos Limited has published Construction Of Women Police Staton At Nahan Himachal Pradesh Construction Of Women Police Staton At Nahan Himachal Pradesh. Submission Date for this Tender is 03-11-2021. Building Work Tenders in Nahan, Himachal Pradesh Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
2 | All kinds of soil. |
3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. |
4 | Ordinary rock |
5 | Hard rock (requiring blasting) |
6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
7 | Disposal of Excavated Earth/rock away from the site including conveyance of materials up to an average lead of 5KM away from the site, and correspondiong required lift, loading, unloading etc complete as directed by the Engineer-in-charge. (The quantity is net quantity of capacity of truck after deduction of 20% for looseness)(considering the maximum disposal location at 5 KM distance) |
8 | Disposal of Excavated Earth By mechanical transport including loading, unloading and stacking. (Lead upto 5KM away from the site) |
9 | Disposal of Excavated Rock By mechanical transport including loading, unloading and stacking. (Lead upto 5KM away from the site) |
10 | Extra for every additional lift of 1.5 m or part thereof in. |
11 | All kinds of Soil |
12 | 1.5m to 3.0m |
13 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
14 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
15 | Supplying chemical emulsion in sealed containers including delivery as specified. |
16 | Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
17 | Anti termite treatment |
18 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
19 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
20 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
21 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
22 | 1:2:4 (1 Cement : 2 coarse sand) : 4 graded stone aggregate 40 mm nominal size) |
23 | 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size) |
24 | 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) |
25 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
26 | Foundations, footings, bases for columns |
27 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
28 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specification. |
29 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
30 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
31 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
32 | Foundations, footings, bases of columns, etc. for mass concrete. |
33 | Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc. |
34 | Suspended floors, roofs, landings, balconies and access platform. |
35 | Shelves (Cast in situ) |
36 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
37 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
38 | Stairs, (excluding landings) except spiral-staircases. |
39 | Extra for shuttering in circular work (20% of respective centering and shuttering items) |
40 | Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like. |
41 | Edges of slabs and breaks in floors and walls |
42 | Under 20 cm wide |
43 | Weather shade, Chajjas, corbels etc., including edges. |
44 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
45 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
46 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
47 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
48 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge (Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately). |
49 | All works upto plinth level. |
50 | All works above plinth level upto floor V level. |
51 | Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. |
52 | Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) |
53 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
54 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.50 mm thick |
55 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
56 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
57 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
58 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
59 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level. |
60 | cement mortar 1:4 (1 cement : 4 coarse sand) |
61 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks). |
62 | Brick work with common burnt clay machine moulded modular bricks of class designation 12.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). Above plinth level upto floor V level |
63 | Providing and fixing 18mm thick gang saw cut ( premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
64 | Granite of any colour and shade |
65 | Area of slab over 0.50 Sqm.( For Counter) |
66 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
67 | Granite work |
68 | Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin baesd adhesive including cleaning etc. complete. |
69 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble /Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete. |
70 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
71 | Granite Stone of approved shade |
72 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
73 | Providing and Fixing stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 meter height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) |
74 | 18 mm thickmirror/ eggshell polished granite stone of approved shade. |
75 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
76 | Second class teak wood |
77 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
78 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
79 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
80 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
81 | 2nd class teak wood |
82 | 50x12 mm |
83 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
84 | Provrd ng and applying / spraying melamlne and requied shade two or more coats on new wood works including a coat ofwood filler/ sealer, surface preparation by sanding etc. complete as per Engineer-in-charae. |
85 | Providing and fixing approved brand and manufacture of Stainless SteelTowerbolt 300 mm long with 10 mm dia ( TR 1210SS) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
86 | Providing and fixing approved brand and manufacture of Stainless Steel Towerbolt 150 mm long with 10 mm dia ( TS 610SS) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
87 | Providing and fixing approved brand and manufacture of Stain less Steel Floor stoper floor mounted half round with 45mm dia (DSHR (SS)) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
88 | Providing and fixing approved brand and manufacture of Stainless Steel Door Buffer wall mounted 22 mm dia,75 mm long (DB (22) along with necessary accessories andscrews etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
89 | Providing and approved brand and manufacture of Brass Door stopper - Door Mounted Hanging Type (DSHT) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
90 | Providing and fixing Sliding bolt (baby latch) with SS lock strip 5"" (BL(B)) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
91 | Providing and fixing approved brand and manufacture of aluminium extruded section tubular type universal hydraulic door closer with Palmet Arm (DC 80 EXT (WP)SS) (having brand logo , embossed on the body, door weight upto 80 kg , 5 lacs Cycles Tested), with speed adjustment along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
92 | Door Handles and Locks |
93 | Providing and fixing approved brand and manufacture of Terza Design Mortice Lever handle On Plate (TER10SC) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
94 | Providing and fixing approved brand and manufacture of Mortice Sash lock (ML100SS) with 85 mm CD & 50 mm Backset along with key cylinder fixing Option along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-incharge. |
95 | Providing and fixing approved brand and manufacture of Mortice Latch (ML100LSS(FR)) For Steel Door Backset along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
96 | Providing and fixing approved brand and manufacture of Euro Profile Cylinder one side key & other side knob 60 mm ( CL201SS) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs" specificatios & as directed by Engineer-in-charge. |
97 | Providing and fixing certified restroom cubicle system of approved make comprising of green guard certified solid compact laminated water proof board, minimum 18 mm thick made as per IS: 2046 (phenolic core board) and as per BS-476/97 for fire retardant for toilet showers, water closet etc . The board shall be manufactured under high pressure and temperature by impregnating kraft papers and outer decorative papers with thermosetting phenolic/ melamine resins (low VOC). The cubicle system shall be resistant towards water, chemical, scratch, impact and heat and shall be anti bacterial, colour fast and shall haveaccessories like door knob, Gravity/ auto return hinges, privacy thumb turn with occupancy indicator, coat Hook, etc all in SS 304. The hardware and fixings includes anchoring of all fixed front panel to floor with SS 316 L brackets/ base plates with a clearance height upto 110 mm, and covered with SS 316 Shoe box plates, wall and corner joineries (brackets and channels) shall be SS 304 grade, SS 304 screws, rubber noise reduction tape . |
98 | The cubicle unit shall be installed in approved finish, shades and colours as per specifications and directions of Engineer-In-Charge,including minimum 5 (five) years warranty against any moisture related damages to all intermediate panels, doors, hardqwares etc. Standard dimension of the cubicle system shall be of approx. 2100 mm Height(overall) x 1500mm Depth and 1000 mm Width which includes 600mm door size width. |
99 | I shaped Cubicle System consisting of front face panel including door and all necessary accessories, fittings and hardware etc. |
100 | L shaped Cubicle System consisting of front face panel including door, intermediate panel and all necessary accessories, fittings and hardware etc. |
101 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture"s specification and direction of engineer in charge all complete. |
102 | 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) board conforming to IS: 2095: (part 3) : 1996 (Board with BIS certification marks) |
103 | Providing and fixingof fire retardant fabricpanels (colour as approved by the consultant) glued to 25mm thick melamine foam over a layer of 9 mm thick commercial ply with 15% perforationsfixed over a framework of 48mm GI Stud of 0.55mm thk @ 600mm c/c . Theply to have perforations as per design drawings. The foam to be backed with 50mm 1000GSM thermally bonded polyester wadding. The rate includes for all Geometry of wall, openings etc. and for complete item including all the required approved material, labour and fixing as per drawings. The work shall be executed by the suppliers Authorized applicators.Approved Make: Malimiano of ABSOUND OVERSEAS, ANUTONE or equivalent. |
104 | TOTAL (Carried Over to Summary of Civil Works) |
105 | STEEL WORK |
106 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
107 | Using M.S. angels 40x40x6 mm for diagonal braces |
108 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
109 | Hot finished welded type tubes |
110 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
111 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
112 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
113 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
114 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
115 | 10 x 60 mm |
116 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
117 | Providing Toughened glass 12 mm thickness fixed to stainless steel ( Grade 304) railing made of Hollow tubes and fixing accessories such as nuts, bolts, fasteners etc.(excluding Stainless steel railing ) |
118 | TOTAL (Carried Over to Summary of Civil Works) |
119 | FLOORING WORK |
120 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
121 | 40 mm thick with 20 mm nominal size stone aggregate |
122 | Extra for pre finished nosing to treads of steps of marble / granite stone. |
123 | Extra for marble / granite stone flooring in treads of steps and risers using single length up to 2.00 metre. |
124 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base ofcement mortar 1 : 4 (1 cement : 4 coarse sand) : |
125 | 25 mm thick. |
126 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
127 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
128 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
129 | Size of Tile 600x600 mm |
130 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
131 | Size of Tile 600x600 mm |
132 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
133 | Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
134 | TOTAL (Carried Over to Summary of Civil Works) |
135 | ROOFING |
136 | Providing and laying gola 75x75mm in cement concrete M15 grade including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase. |
137 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
138 | Gypsium False Ceiling |
139 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, |
140 | including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings,pecification and direction of the Engineer in Charge but excluding the cost of painting with : |
141 | 12.5 mm thick tapered edge gypsum moisture resistant board. |
142 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
143 | Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building. |
144 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
145 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
146 | Ridges plain (500 - 600mm) |
147 | Flashings/ Aprons.( Upto 600 mm) |
148 | Gutter (600 mm over all girth) |
149 | TOTAL (Carried Over to Summary of Civil Works) |
150 | FINISHING WORK |
151 | 12 mm cement plaster of mix : |
152 | 1:6 (1 cement: 6 coarse sand) |
153 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
154 | 1:6 (1 cement: 6 coarse sand) |
155 | 20 mm cement plaster of mix : |
156 | 1:4 (1 cement: 4 coarse sand) |
157 | 6 mm cement plaster of mix : |
158 | 1:3 (1 cement: 3 fine sand) |
159 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
160 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
161 | 10m to 13m |
162 | 13m to 16m |
163 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
164 | White washing with lime to give an even shade : |
165 | New work (three or more coats) |
166 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : |
167 | New work (two or more coats) over and including water thinnable priming coat with cement primer |
168 | Finishing walls with textured exterior paint of required shade : |
169 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
170 | Applying priming coat: |
171 | With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
172 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work. |
173 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
174 | Two or more coats on new work |
175 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
176 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
177 | Providing and fixing Glass Reinforced Concrete (G.R.C) Screen at all levels & heights in approved size, pattern, design, thickness and color. The Screens should be made from ‘53 grade’White Portland Cement, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber, Super Plasticizers, Polymers and U.V resistant Synthetic inorganic pigments should be used for pigmentation. The material casting should take place in Synthetic Rubber / FRP Mould. The fixing of Jali should be ‘Dry fixing’ i.e. to be done with MS/SS ‘L’ shaped Clamps, dash fasteners and pins etc as per site requirment. |
178 | TOTAL (Carried Over to Summary of Civil Works) |
179 | ROAD WORK |
180 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres. |
181 | Supplying and Stacking of Good Earth by mechanical transport including loading, unloading including royalty & carriage up to 5 KMcomplete. |
182 | Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). |
183 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineerin- Charge. |
184 | With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
185 | Providing and laying design mix cement concrete of M-30 grade, in roads/taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:-Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. |
186 | Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer |
187 | Extra for providing and mixing hardening compound of approved quality as per manufacturer’s specification in cement concrete. |
188 | Providing and fixing in position pre-moulded joint filler in expansion joints. |
189 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound. |
190 | Providing and laying factory made coloured chamfered edge Cement Concrete paver blocks of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer’s specifications & direction of Engineerin-Charge. |
191 | 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
192 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. |
193 | New work (Two or more coats) |
194 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. |
195 | Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
196 | Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1cement:4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in charge. |
197 | Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete |
198 | 450 mm dia RCC pipes. |
199 | TOTAL (Carried Over to Summary of Civil Works) |
200 | ALUMINIUM WORK |
201 | Providing & fixing of two shutter sliding windows made of pre painted steel & Galvanized steel ( Base steel as per IS 513 D quality, galvanized as per IS 277 with zinc of 120 GSM), using factory made section powder coated with pure polyester powder upto 50-60 microns thick with total coated thickness of 0.58mm for outer frame and 0.58mm thickness for sliding shutter section, the outer frame for two track with grill provisionsi size of 90mm x 50mm and the window shutter section of 58mmx36mmand the outer frame with two integrated guide tracks of 12mm width and 24 mm deep for provision to slide the shutter/sash frame and facilitates with a water drain outlet component made of pvc and the shutter frame fitted with 5mm thick clear float glass of reputed make and fixed with EPDM weathering seal resistant accessories and handle made of Aluminium1 No. per each shutter and cut to length mitre joinedwith corner bracketsincluding installationsof window systemat site using anchor fastners inclusive of conveyanceof all materials, accessories, labour charges and erection at site with complete finished item of work.Glass and Grill are Extra on actuals. (Make: A2Z Infra Solutions/ Elixir Metform Pvt Ltd/ Lakshmi Fabrication) |
202 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. |
203 | Pre-laminated particle board with decorative lamination on both sides |
204 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
205 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
206 | With float glass panes of 8 mm thickness (weight not less than 20 kg/ sqm) |
207 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). |
208 | Providing and fixing Stainless steel 304 Grade H- type pull handle of size min 32 mm dia and 1200mmlong ofapproved make including SS screws, including making holes of required size in shutter etc. complete as per direction of Engineer-in-Charge. |
209 | Providing and fixing SS Bottom patch Lock with cylinder of approved make including necessary screws etc. all complete. |
210 | Providing and fixing SS floor mounted half dome door stopper of dia 45mm including necessary screws etc. all complete. |
211 | Providing and fixing 12mm thk. Toughened float glass glazing cut and fixed in openings of desired shape as per drawing with 3/4" beveling all around, fixed with the help of SS patch fittings, with top and bottom "C" channels, fixed firmly to the slab/ MS Structure ,as directed by Engineer in Charge. Area of openings to be measured). Assume frameless glass. Rate of above item to include P/F of : 20x20mm "C" channelSS patch Fittings. |
212 | Providing & fixing of two shutter sliding windows made of pre painted steel & Galvanized steel ( Base steel as per IS 513 D quality, galvanized as per IS 277 with zinc of 120 GSM), using factory made section powder coated with pure polyester powder upto 50-60 microns thick with total coated thickness of 0.58mm for outer frame and 0.58mm thickness for sliding shutter section, the outer frame for two track with grill provisionsi size of 90mm x 50mm and the window shutter section of 58mmx36mmand the outer frame with two integrated guide tracks of 12mm width and 24 mm deep for provision to slide the shutter/sash frame and facilitates with a water drain outlet component made of pvc and the shutter frame fitted with 5mm thick clear float glass of reputed make and fixed with EPDM weathering seal resistant accessories and handle made of Aluminium1 No. per each shutter and cut to length mitre joinedwith corner bracketsincluding installationsof window systemat site using anchor fastners inclusive of conveyanceof all materials, accessories, labour charges and erection at site with complete finished item of work.Glass and Grill are Extra on actuals. (Make: A2Z Infra Solutions/ Elixir Metform Pvt Ltd/ Lakshmi Fabrication) |
213 | TOTAL (Carried Over to Summary of Civil Works) |
214 | WATER PROOFING |
215 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
216 | Supplying and Stacking Filling sunken floor with over burntjhama brick aggregate 120mm to 40mmincluding compacting of materials complete as specified and directed for all levels. |
217 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
218 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
219 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
220 | Providing of Polymeric Formliners wooden planks or roofing slate design or in other approved design and pattern of Everest/Birla/Dalal/Unistone make. The Formliners Sheet thickness of 5 mm made with fire retardant polyester resin based on phthalic anhydride and standard glycols with additives that give excellent fire-retardant properties with reference to IS 6746. Glass fiber of Owens Corning or Equivalent of 300 to 450 gsm mat to be used added with suitable pigments by reputed manufacturer. Formliners shall be fixed with suitable approved fasteners to the surrounding on surface of RCC/ masonry work/ MS frame. The Formliners must be fixed in true to line & level/ plumb with edges finished provided without any extra cost to client. Any MS/Aluminium supports, if required, shall be paid for separately.- External Cladding on walls |
221 | Providing of Polymeric Formliners wooden planks or roofing slate design or in other approved design and pattern of Everest/Birla/Dalal/Unistone make. The Formliners Sheet thickness of 5 mm made with fire retardant polyester resin based on phthalic anhydride and standard glycols with additives that give excellent fire-retardant properties with reference to IS 6746. Glass fiber of Owens Corning or Equivalent of 300 to 450 gsm mat to be used added with suitable pigments by reputed manufacturer. Formliners shall be fixed with suitable approved fasteners to the surrounding on surface of RCC/ masonry work/ MS frame. The Formliners must be fixed in true to line & level/ plumb with edges finished provided without any extra cost to client. Any MS/Aluminium supports, if required, shall be paid for separately.- roof tiles on existing slab |
222 | Providing and layingLaminate wooden flooring (Grade AC4or AC4+ laminates)6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fibreboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated withmelamineresinandtop wearlayerhavingclearaluminiumoxide finishthatprotectsthedecorative layer& imparts the desired level of sheen, from full gloss to low gloss,duly fixed to the base floor using adhesive as approved by the manufacturer. |
223 | TOTAL (Carried Over to Summary of Civil Works) |
224 | PLUMBING |
225 | SANITARY INSTALLATIONS |
226 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
227 | Providing and fixingof Health Faucetof approved quality with 1.5m long plastic NBR braided pipe (SS braiding) flexible pipe, wall hooked complete as required. (Make-CERA, Model-F8030202) |
228 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
229 | W.C. pan with ISI marked white solid plastic seat and lid |
230 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (Handicapped Toilet) |
231 | Providing and fixingof 1 No. U-shaped rail with wall mounting of (Size: 600x100mm) at fixed height for handicap toilet complete as required. (Make-CERA, Model-2501) |
232 | Providing and fixingof 1 No. Wall Mounted Grab Bar of (Size: 500mm) at fixed height for handicap toilet complete as required. (Make-CERA, Model-2504) |
233 | Providing and fixingof 1 No. Wall Mounted Grab Bar of (Size: 350mm) at fixed height for handicap toilet complete as required. (Make-CERA, Model-2505) |
234 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
235 | White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
236 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. |
237 | Providing and fixing PTMT grating of approved quality and colour. |
238 | Circular type |
239 | 100 mm nominal dia |
240 | Rectangular type with openable circular lid |
241 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating |
242 | Providing and fixing toilet paper holder : |
243 | C.P. brass |
244 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
245 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
246 | Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
247 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. |
248 | Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms |
249 | Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms |
250 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
251 | 150 mm diameter |
252 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
253 | 15 mm nominal bore |
254 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
255 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
256 | 15 mm nominal bore |
257 | INTERNAL SEWERAGE & DRAINAGE |
258 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings(door or plain) viz elbolws, bends, tees, junctions, shoe bends, couplers, offsets, cowel etc. complete including jointing with solvent cement including GI supports,cutting and making good the walls wherever required. Nothing extra will be paid for supports.(Vertical Soil, waste, balcony waste & rain water pipes) |
259 | 110 OD |
260 | Providing and fixing 100mm dia nominal bore uPVC pipe (Class-III)-IS:4985 inlet fitting approximately upto 300mm long above the trap with one or more 40 OD/ 50OD/63 OD/75OD holes for jointing waste pipes from waste appliances jointed and sealed with epoxy based sealant complete. |
261 | 40 OD uPVC pipe |
262 | 63 OD uPVC pipe |
263 | Providing and fixing uPVC floor drain consisting of PVC reducing elbow 110 x 63mm (Grating and pvc pipe to be paid separately), complete as directed by the Project Manager. |
264 | Providing and fixing uPVC SWR P Trap with minimum 50mm water seal conforming to IS 13592 |
265 | 110 mm inlet & 110 mm outlet |
266 | Providing and fixing PVCCOP /FCO with suitable insert keys for opening as per approved sample, properly jointed to soil andwaste pipe asper requirement, complete as per instructions of the Engineer in charge. |
267 | For 110 mm dia pipe |
268 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
269 | 110 mm diameter |
270 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
271 | Single tee without door |
272 | 110x110x110 mm |
273 | Bend 87.5° |
274 | 110 mm bend |
275 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
276 | 110 mm |
277 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
278 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
279 | For pipes 100 to 250 mm diameter |
280 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
281 | 110 mm diameter |
282 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
283 | Single tee without door |
284 | 110x110x110 mm |
285 | Bend 87.5° |
286 | 110 mm bend |
287 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
288 | 110 mm |
289 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
290 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
291 | For pipes 100 to 250 mm diameter |
292 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
293 | All Kind of Soil |
294 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
295 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
296 | All Kind of Soil |
297 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
298 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
299 | 150 mm diameter |
300 | 250 mm diameter |
301 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : |
302 | 150 mm diameter S.W. pipe |
303 | 250 mm diameter S.W. pipe |
304 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
305 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
306 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
307 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
308 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
309 | 180x150 mm size P type |
310 | With Sewer bricks conforming to IS : 4885 |
311 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : |
312 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
313 | INTERNAL WATER SUPPLY |
314 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
315 | Internal work - Exposed on wall |
316 | 15 mm OD |
317 | 20 mm OD |
318 | 25 mm OD |
319 | 32 mm OD |
320 | 40 mm OD |
321 | 50 mm OD |
322 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
323 | Concealed work, including cutting chases and making good the walls etc. |
324 | 15 mm nominal outer dia Pipes |
325 | 20 mm nominal outer dia Pipes |
326 | 25 mm nominal outer dia Pipes |
327 | 32 mm nominal outer dia Pipes |
328 | Providing and fixing brass bib cock of approved quality |
329 | 15 mm nominal bore |
330 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
331 | 15 mm nominal bore |
332 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
333 | 25 to 40 mm nominal bore |
334 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
335 | 15 mm nominal bore |
336 | 20 mm nominal bore |
337 | 25 mm nominal bore |
338 | 32 mm nominal bore |
339 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
340 | 25 mm nominal bore |
341 | 20 mm nominal bore |
342 | 32 mm nominal bore. |
343 | 40 mm nominal bore. |
344 | 50 mm nominal bore. |
345 | 65 mm nominal bore. |
346 | Prividing and Fixing automatic "NO-Touch " electric hand-driers complete with all accessories & fittings. (Make: Jaquar Model No. HDR-SAP-M99ACS) |
347 | Providing and fixing Water cooler with inbuilt RO and storage complete including fixing in position. |
348 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
349 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. |
350 | 15 mm dia nominal bore |
351 | 20 mm dia nominal bore |
352 | 25 mm dia nominal bore |
353 | 32 mm dia nominal bore |
354 | 40 mm dia nominal bore |
355 | 50 mm dia nominal bore |
356 | 65 mm dia nominal bore |
357 | INTERNAL FIRE |
358 | SUB HEAD-A (PIPING & VALVES) |
359 | Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
360 | 25 mm dia. |
361 | 100mm dia |
362 | 150mm dia |
363 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : |
364 | 150 mm dia |
365 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
366 | 25 mm dia. |
367 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
368 | 100 mm dia. |
369 | 150 mm dia. |
370 | Providing and fixing dial type pressure gauge with isolation cock and copper pipeat hydrant station. |
371 | Dial diameter 100 mm calibration 0-15 kg/ sq.cm. |
372 | Providing,installation,testingandcommissioningof stainlesssteelY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdia holes with stainless steel flange. |
373 | 150mm dia |
374 | Providing laying, testing & commissioning of "C" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
375 | 150 mm. Dia |
376 | TOTAL SUB HEAD-A (PIPING & VALVES) C/F TO SUMMARY |
377 | SUB HEAD-B (FIRE HYDRANT ACCESSORIES) |
378 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : |
379 | Single headed Gunmetal |
380 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
381 | 30m |
382 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
383 | Gun Metal |
384 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : |
385 | Gun Metal |
386 | Providing and fixing doorwith frame for all internal fire hydrants fabricated from 20x20x3mm and40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge onAluminium angle frame of 45x45x5mm size with hold fasts fixed to wallwithP.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement& fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with " fire hose" written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 1200x 600 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.) |
387 | Supplying and fixing of Fire Man"s Axe with heavy insulated rubber tested upto 20 KV and confirming to IS :926. |
388 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
389 | Supplyingandfixingoffirebrigadeconnectionof cast iron body with gun metal male instantaneous inlet couplingscompletewithcapandchainasreqd.for suitabledia MS pipe connectionconforming to IS 904 as required : |
390 | 2 way-100 mm dia M.S. Pipe |
391 | TOTAL SUB HEAD-B (FIRE HYDRANT ACCESSORIES) C/F TO SUMMARY |
392 | SUB HEAD-C (FIRE EXTINGUISHERS & MISC. ITEMS) |
393 | Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, dischargenozzle, suspension bracket, confirming to IS: 15683 finished externally with redenamelpaint andfixed towall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.) |
394 | Providing and fixing waterCo2(ISI marked) extinguishers includingall accessoriesas per IS specification with wall bracket with rawl plug |
395 | Capacity 9 liters.(IS:15683) |
396 | TOTAL SUB HEAD-C (FIRE EXTINGUISHERS & MISC. ITEMS) C/F TO SUMMARY |
397 | SUB HEAD-D (FIRE PUMPS & ACCESSORIES) |
398 | Supplying,installation,testingandcommissioningof electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall respects, as required: (Terrace Pump) |
399 | (a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
400 | b)SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-"F"insulation, conforming to IS-325. |
401 | (c)M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
402 | (d)Suitablecementconcretefoundationdulyplastered and with anti vibration pads. |
403 | 450 lpm at 35 m Head |
404 | Providingandfixingliquidlevel controller for fire pumpto stop fire pump in caseoflow level of water in tank , cost of conduit, cable and panel including making connection to pump panel and commissioning complete. |
405 | Float type Sensor with panel and installation |
406 | Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges)as per specification of the manufacturers and direction of Engineer in chief PN-16 rating |
407 | 150 mm dia |
408 | EXTERNAL FIRE |
409 | SUB HEAD A - PUMPS |
410 | Supplying,installation,testingandcommissioningof Electric driven Main Fire Pump suitablefor automatic operationandconsistingoffollowing,completeinall respects, as required : |
411 | Horizontal type, singlestage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. |
412 | Suitable HP Squirrel cage induction motor, TEFC, synchronousspeed1500RPM,suitableforoperation on415volts,3phase50Hz,ACsupplywithIP55 protectionforenclosure,horizontalfootmountedtype with Class-"F" insulation, conforming to IS-325. |
413 | M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. |
414 | Suitablecementconcretefoundationdulyplastered with anti vibration pads. |
415 | 1620 lpm at 70 m Head |
416 | Note: *The head of the pump is selected in a manner soastogiveaminimum 3.5kgf/cm 2pressureatthe highest/farthest point. |
417 | Supplying,installation,testingandcommissioningof diesel engine driven main fire pump suitable for automatic operation and consistingof following, completeinallrespects,asrequired:(DieselDriven Pump) |
418 | Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. |
419 | SuitableHP,1500RPMwatercooledwithradiator, diesel engine conforming to relevant IS standard completewithautostartingmechanism,12/24volts electricstartingequipment,dieseltank,exhaustpipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. |
420 | M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. |
421 | Suitablecementconcretefoundationdulyplastered and with anti vibration pads. |
422 | 1620 lpm at 70 m Head |
423 | Note: * The head of the pump is selected in a manner soastogivea minimum 3.5kgf/cm 2 pressureat the highest/farthest point. |
424 | Supplying,installation,testingandcommissioningof electricdrivenpressurisationpumpsuitablefor automaticoperationandconsistingoffollowing, complete in all respects, as required : (Jockey Pump) |
425 | Horizontaltype,multistage,centrifugalpumpofcast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. |
426 | SuitableHPsquirellcageinductionmotorTEFCtype suitableforoperationon415volts,3phase50Hz AC supply with IP 55 class of protection for enclosure, horizontalfootmountedtypewithClass-"F"insulation, conforming to IS : 325. |
427 | M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. |
428 | Suitablecementconcretefoundationdulyplastered and with anti vibration pads. |
429 | 180 lpm at 70 m Head |
430 | CONTROL PANELS |
431 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : |
432 | INCOMING |
433 | 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. |
434 | LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A |
435 | OUTGOING |
436 | ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) |
437 | Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
438 | Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
439 | DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
440 | SUB HEAD B - PIPES & ACCESSORIES |
441 | Providinglaying,testing&commissioningof"C"class heavydutyMSPipeconformingtoIS1239/3589i/c fittingslikeelbows,tees,flanges,tapers,nutsbolts, gasketsetc.ingroundincludingwelding,excavation& providingcementconcreteblocksassupports, anticorrosivetreatmentwithcoaltar/asphalttapeasper IS10221,refillingthetrenchetc.offollowingsizes complete as required. |
442 | 150 mm. Dia |
443 | Providing,laying,testing&commissioningof "C"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
444 | 25 mm dia |
445 | 32 mm dia |
446 | 40 mm dia |
447 | 50 mm dia |
448 | 65 mm dia |
449 | 80 mm dia |
450 | 100 mm dia |
451 | 150 mm dia |
452 | 200 mm dia (wall thickness 6.3 mm) |
453 | 250 mm dia (wall thickness 6.3 mm) |
454 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI markedcompletewithnuts,bolts,washers,gaskets conforming to IS 13095 of following sizes as required : |
455 | 50mm dia |
456 | 80 mm dia |
457 | 100 mm dia |
458 | 150 mm dia |
459 | 200 mm dia |
460 | 250 mm dia |
461 | Providing,installation,testingandcommissioningof non-returnvalveoffollowingsizesconfirmingtoIS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
462 | 50mm dia |
463 | 65mm dia |
464 | 80mm dia |
465 | 150mm dia |
466 | 200mm dia |
467 | Providing,installation,testingandcommissioningof stainlesssteelY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdia holes with stainless steel flange. |
468 | 250mm dia |
469 | Supplyingandfixingoffirebrigadeconnectionof cast iron body with gun metal male instantaneous inlet couplingscompletewithcapandchainasreqd.for suitabledia MS pipe connectionconforming to IS 904 as required : |
470 | 2 way-100 mm dia M.S. Pipe |
471 | 4 way - 150 mm dia M.S. Pipe |
472 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valveontopandflangedconnectiontoriser,drain arrangementwith25mmdiagunmetalwheelvalve withrequiredaccessories,pressuregaugeand paintingwith synthetic enamel paint of approved shade as required. |
473 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
474 | Providing& fixingflowswitchinfollowingsizesM.S. pipe including connection etc as required. |
475 | 150mm dia |
476 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
477 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
478 | 25 mm dia. |
479 | Providing and fixing dial type pressure gauge with isolation cock and copper pipeat hydrant station. |
480 | Dial diameter 100 mm calibration 0-15 kg/ sq.cm. |
481 | Providing laying, testing & commissioning of "C" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
482 | 150 mm. Dia |
483 | SUB HEAD-C (NON DSR ITEMS) |
484 | Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, dischargenozzle, suspension bracket, confirming to IS: 15683 finished externally with redenamelpaint andfixed towall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.) |
485 | Providing and fixing waterCo2(ISI marked) extinguishers includingall accessoriesas per IS specification with wall bracket with rawl plug |
486 | Capacity 9 liters.(IS:15683) |
487 | Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, dischargenozzle, trolly mounted, confirming to IS: 15683 finished externally with redenamelpaint andfixed towall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 22.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.) |
488 | Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges)as per specification of the manufacturers and direction of Engineer in chief PN-16 rating |
489 | 50 mm dia with flange, fasteners, bolts and packing gaskets. |
490 | 65 mm dia with flange, fasteners, bolts and packing gaskets. |
491 | 150 mm dia with flange, fasteners, bolts and packing gaskets. |
492 | Supplying and fixing of fire withdrawl connection of aluminium body with instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection. |
493 | 100 mm dia M.S. Pipe |
494 | Providing laying, testing & commissioning of "C" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
495 | 100 mm. Dia |
496 | 80 mm. Dia |
497 | ELECTRICAL DSR |
498 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
499 | Group A |
500 | Group B |
501 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
502 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
503 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
504 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
505 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
506 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
507 | 25mm |
508 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
509 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
510 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
511 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
512 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
513 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
514 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
515 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings |
516 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required |
517 | SUB HEAD -2 : LIGHT AND FAN FIXTURES |
518 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required |
519 | Installation, testing and commissioning of ceiling fan,includingwiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required |
520 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
521 | Upto 450 mm sweep |
522 | SUB HEAD -3 : DISTRIBUTION BOARD |
523 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
524 | 200 A, 36 KA,FPMCCB |
525 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
526 | 6 way , Double door |
527 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator |
528 | 8 way (4 + 18), Double door |
529 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used |
530 | 4 way (4 + 12), Double door (for UPS) |
531 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
532 | Single pole and neutral |
533 | Triple pole and neutral |
534 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
535 | 63A |
536 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
537 | 25A |
538 | 40A |
539 | 63A |
540 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. |
541 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required. |
542 | TOTAL OF SUBHEAD 3 |
543 | SUB HEAD -4 : EXTERNAL WORK |
544 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
545 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
546 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
547 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required |
548 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
549 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run |
550 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required |
551 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required |
552 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
553 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
554 | SUB HEAD -5 : TRAY ,RACEWAYS |
555 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
556 | 300 mm width X 50 mm depth X 1.6 mm thickness |
557 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
558 | 300 mm width X 50 mm depth X 1.6 mm thickness |
559 | SUB HEAD -6 : CABLE WORKS |
560 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
561 | Above 95 sq. mm and upto 185 sq. mm |
562 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required |
563 | Above 95 sq. mm and upto 185 sq. mm |
564 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
565 | 3.5CX150SQMM |
566 | SUB HEAD -8: LOW VOLATGE SYSTEM |
567 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
568 | 2 Pair |
569 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
570 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
571 | Telephone socket outlet |
572 | TV antenna socket outlet |
573 | Bell push |
574 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required |
575 | 1 or 2 Module (75mmX75mm) |
576 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
577 | 2 run of cable |
578 | ELECTRICAL NON DSR |
579 | SUB HEAD - I : WIRING |
580 | Supplying and fixing of following sizes of steel conduit along with accessories insurface/recess including painting in case of surface conduit, or cutting the FLOORand making good the same in case of recessed conduit as required. |
581 | 25MM |
582 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
583 | USB charger socket |
584 | SUB HEAD -2 : LIGHT AND FAN FIXTURES |
585 | Supply of lighting fixtures |
586 | 36W RECESSED LED LIGHT FIXTURE - (RC380B LED25S-6500 G5 L60W60 PSU OD) OR BAJAJ ,WIPRO |
587 | 18W LED DOWN LIGHT FIXTURE-DN295B LED6S-6500 PSU WH OR BAJAJ ,WIPRO |
588 | 12W LED BATTEN LIGHT FIXTURE-BN308C LED20S-6500 L120 PSU WH OR BAJAJ ,WIPRO |
589 | 8W MIRROR LIGHT FIXTURE (BN 021 LED12S 6500 PSU GR)OR BAJAJ ,WIPRO |
590 | BULK HEAD 9W (WT202W LED10S CW PSU S2 PC) OR BAJAJ ,WIPRO |
591 | LED WALL LIGHT 18 WATT |
592 | LED HIGH BAY 40W |
593 | supply of ceiling fan 1200 sweepwith all accessories.Make -havels or equivalent |
594 | supply of exhaust fan 450 sweep with all accesoroes and louwers |
595 | SUB HEAD -3 : DISTRIBUTION BOARD |
596 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
597 | 12 way tpn DB -double door |
598 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . |
599 | 12 way (4 + 36), Double door |
600 | Supplying and fixing 63 A rating, 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existingVDB complete with connections, testing and commissioning etc. as require |
601 | Supplying and fixing 5-63 A rating, 415 V, electronic KWH meter with outdoor type enclosure |
602 | SUB HEAD -4 : ELECTRICAL EXTERNAL WORK |
603 | S/I/T/CLED post top/gate light 45 watts5000 Lumens, IP65, Cast aluminium spigot housing.,Opal acrylic diffuser,Suitable for 60mm OD pipe entry with fixing bolts.,The light should be of Philips Model BGP300 LED50 757 PSU PC IN S1 or equilavlent in LT, Shreder, GE |
604 | Building Outer Light (60W LED) :- Supply, fitting, fixing and testingof building outer lighting luminaire aerodynamically shaped single piece pressure die-cast Aluminum luminaire with high power LEDs as light source and electronic driver (IP66), along with 60W LED Lamp as Energy savingas per drawing prescribedreflector and heat resistant toughened flat glass cover, with 5ft long 40mm dia G.I. pipe with 3 Nos. of iron clamps , anchor nut bolts with double washers as per direction of E/I or consultant as per drawing prescribedreflector and heat resistant toughened flat glass cover. (Make:- Philips/Trilux/Hevells-Endura Pearl Neo/Wipro. |
605 | TOTAL OF SUBHEAD 4 |
606 | SUB HEAD -5: TRAY ,RACEWAYS |
607 | Supplyinging, installation, testing & commissioning of GI openable top cover raceway made from 2mm thick pre-galvanized sheets for top, bottom and sides and complete with 2mm thick top cover complete with rubber gasketing. The junction box shall be suitable to accommodate GI raceways specified below. Necessary civil work to support/ clamp from RCC slab/floor need to be included here too.(Junction Box price not included in the item). |
608 | 200 mm wide x40 mm deep |
609 | Supplyinging, installation, testing & commissioning offloor/ceiling recessed junction boxes for GI raceway systems fabricated from 3 mm MS sheets finished with pre-galvanized sheets, including 2 nos. GI strip at side for earthing, with 1, 2 or 3 nos "+", "I", ""L" shaped support in the centre in case required with 3 mm thick neoprene gasketted removable cover fixed by counter sunk cadmium plated screws including the cost of earth links at all joints to ensure earth continuity and including the cost of chasing and making good recess in floor etc complete as required and as below. (in ceiling / Floor)(Only junction box price included in the item.) |
610 | 200X200mm |
611 | SUB HEAD -6 : CABLE WORKS |
612 | Supply of PVC insulated and PVC sheathed PVC/ XLPE insulated Aluminum/copper conductor power multicore armoured cable of 1.1 KV grade |
613 | 3.5CORE X 150 SQMM |
614 | SUB HEAD -7 : LT PANELS |
615 | Supply, installation, testing and commissioning of following panel boards.All panel boards/Enclosuresshall be fabricated out of 16 SWG /1.6MM CRCA sheet.free standing, floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, "T" sectionswherever necessary fully meeting all the requirements specified in the technical specifications and drawings.Galvanized hardware with zinc passivation shall be used in fabrication. TPN switch gears shall be supplied with equally rated neutral link. |
616 | All MCB’s shall be of minimum 10 KA breaking capacity. |
617 | Current density of aluminiumshall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for rated current of bus bars. |
618 | UPS PANEL |
619 | incomming |
620 | 6 A MCB, with LED indicators for phase and ON/OFF/TRIP- 1 set |
621 | 1 nos of multidata meter and 3nos of 63/5A ,class 1, 15VA CT -1 set |
622 | 63A,500V,25KA,TPN, thermal magnetic based MCCB with o/c, e/f and s/c protection-2each |
623 | 63A,500V,25KA,4P CONTACTOR-2each |
624 | 160A,25kA 3PH 4 wire Al. busbar |
625 | Outgoing |
626 | 63A,Mcb-2 each |
627 | 32A tpn mcb -2 each |
628 | LIFT PANEL |
629 | incomming |
630 | 6 A MCB, with LED indicators for phase and ON/OFF/TRIP- 1 set |
631 | 63A,500V,25KA,TPN,ISOLATOR-1each |
632 | 63A,25kA 3PH 4 wire Al. busbar |
633 | Outgoing |
634 | 40A,4P, 100mA RCCB-1 each |
635 | 16A,2P, 30mA RCCB-1 each |
636 | 63A,4PMCCB-1 each |
637 | 16A DP MCB -1 each |
638 | SUB HEAD -8 : LOW VOLATGE SYSTEM |
639 | EPABX |
640 | CCTV |
641 | Supply, installation, testing and commissioning of 2 megapixels resolution Network Bullet camera camera,Imager 1/2.8”SONY 2.43 mega low illumination CMOS,Video Compression. .H.264/MJPEG,Day/Night .Mechanical ICR,Minimum Illumination-0Lux/F1.4(IR ON) IR Illumination-40-50M,,Electronic Shutter-Auto/Manual(1/25~1/10000) Lens 2.8 – 12 mm varifocal lens,Resolution Main-stream:D1/Q1080P(960*540)/HD720P/ HD1080P 1-25/30fps,Digital Noise Reduction-3D,Wide Dynamic Range-Digital WDR Motion Detection -4 Zones, Multi- Level Sensitivity,Privacy Zones-4 Zones,Snapshoot-Support JPEG format,Password Protection-Support,Character Display-Support(Channel /Date).Regulatory Emissions-FCC Part 15 CE: EN55022,Immunity -CE: EN50130-4,IP Rating- IP66 rated enclosure to protect against dust and water damage ONVIF compliant .Make-Tyco/Mobotix/Pelco |
642 | Supplying, installation, testing and commissioning of 2 megapixels resolution Network Dome Camerafor true HD quality images, 2.8 – 12 mm varifocal lens,True Day/Night (TDN) functionality for true color image ,Motion Detection 4 Zones, Multi- Level Sensitivity Privacy Zones 4 Zones,SnapshootSupport JPEG format Password Protection Support Character Display Support(Channel /Date) ONVIF Yes,IR Illumination20-30M IR illuminators for clear images in low light conditions Wide Dynamic Range 3D noise reduction for sharper images and lower bandwidth use in low lightONVIF compliant complete in all respect.Make-Tyco/Mobotix/Pelco |
643 | SSupply, installation, testing and commissioning 8 channel Network Video Recorder |
644 | Supply, installation, testing and commissioning of Enterprise Class6TB HDD. Make-WD/Seagate |
645 | Supply, installation, testing and commissioning ofVideo Management System (VMS) software shall be used to view live and recorded video from capture cards and IP devices connected to local and wide area networks. The VMS software shall have a client/server-based architecture that can be configured as a standalone VMS system with the client software running on the server hardware and/or the client running on any network-connected TCP/IP workstation. Multiple client workstations shall be capable of simultaneously viewing live and/or recorded video from one or more servers. Multiple servers shall also be able to simultaneously provide live and/or recorded video to one or more workstations. The VMS server software shall also have the ability to be installed on an IP edge device—such as an IP camera or encoder that allows for 3rd party applications—allowing the device to serve as both a server and IP video recording device.The VMS shall not charge for the number of concurrent clients (min. 50 thick clients and 16 mobile clients to be provided along with VMS).Make-Tyco/Mobotix/Pelco |
646 | Supply , Installation , Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i5 7th Gen Processor (12M Cache, 6 core, 3.2 GHz); RAM: 16GB RAM ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; 4GB 4K Graphics Card; Network interface card: Integrated Intel(R)Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 2 TB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 10 Professional 64 Bit or latest complete etc. as required. Make: HP/DELL/ |
647 | SUBHEAD -9: MISCELLANEOUS ITEMS |
648 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
649 | Supply and fixing glass framed shock treatment chart.900mm x 600mm high, printed preferably in three languages i.e. Hindi, English & local language; |
650 | Supplying and fixing of high voltage insulation mat of class B having 1.1 KV dielectric strength, 1000mm width and thickness of 2.0 mm ISI approved as required including cutting to required lengths. |
651 | Supply andinstallation of DCP type fire extinguisher of capacity 5 kg with upright operation conforming to IS:2171 having a jet length of 8m with discharge time of 10 sec including all accessories. |
652 | Standard first aid box - prescribed by St.John Ambulance brigade or India Red Cross shall be provided (First aid box should be of 18 gauge M.S sheet of size 14" x 17" x 5"):- |
653 | 10 KVA On-Line UPS System with PWM-IGBT technology,Isolation transfromer, 230V AC Input (160V – 280V)3 Ph input- 3 Ph outputwith 0.8 PF,60 min backup using SMF battery.BATTARY/RACK also included |
654 | Supply, installation ,testing and commissioning of SMF battery.Battery sizing calculation shall be submitted for approval. |
655 | Supply, installation ,testing and commissioning of racks for smf batteries along with interconnecting links and Dc cables upto 6 meters |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy