Construction Of Divisional Office Building At Fci Fsd Nandannagar, Tripura Construction Of Divisional Office Building At Fci Fsd Nandannagar, Tripura, FCI FSD Nandannagar, Tripura-Tripura

Food Corporation Of India-FCI has published Construction Of Divisional Office Building At Fci Fsd Nandannagar, Tripura Construction Of Divisional Office Building At Fci Fsd Nandannagar, Tripura. Submission Date for this Tender is 08-11-2021. Building Work Tenders in FCI FSD Nandannagar, Tripura Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

29538800
Corrigendum : Construction Of Divisional Office Building At Fci Fsd Nandannagar, Tripura Construction Of Divisional Office Building At Fci Fsd Nandannagar, Tripura
Open Tender
Indian
Tripura
FCI FSD Nandannagar, Tripura
08-11-2021

Tender Details

Construction Of Divisional Office Building At Fci Fsd Nandannagar, Tripura Construction Of Divisional Office Building At Fci Fsd Nandannagar, Tripura

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Oct-2021 BOQ Financial Bid 08-11-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 2.32 Crore /-

BOQ Items

Name of Work:Construction of Divisional office Building at FSD Nandannagar, Tripura.
Sl. No. Item Description
1Civil Works
2Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
4Supplying and filling in plinth with sand under floors including, watering, ramming consolidating and dressing complete.
5Diluting and injecting chemical emulsion for POST CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floor :With chlorpyriphos E.C. 20% with 1% concentration.
6Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1: Cement :6 Coarse Sand : 12:graded stone aggregate 20mm nominal size ) at plinth level withCement mortar 1:6 (1 cement :6 coarse sand)
7Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -all work upto plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
9Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,shuttering, finishing and reinforcement-All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
10Reinforced cement concrete work in walls(any thickness) including attached pilasters,buttresses,plinth and string courses,fillets,column,pillars,piers,abutments,post and struts etc.up to floor five level excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size ).
11Centering and shuttering including struting, propping etc. and removal of form for all heights. Foundations, footings,bases of columns, etc. for mass concrete
12Centering and shuttering including struting, propping etc. and removal of form for all heights.Suspended floors, roof, landings, balconies and access platform
13Centering and shuttering including struting, propping etc. and removal of form for all heights. Lintels, beams, plinth beams, girders, bressumers and cantilevers
14Centering and shuttering including struting, propping etc. and removal of form for all heights :Columns,pillars, piers, abutments, posts and struts.
15Centering and shuttering including struting, propping etc. and removal of form for all heights : Stairs, (excluding landings) except spiral-staircase
16Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
17Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : Cement mortar 1:4 (1 cement :4 coarse sand)
1812 mm cement plaster of mix :1:4 (1 cement :4 fine sand)
1915 mm cement plaster on the rough side of single or half brick wall of mix1:4 (1 cement: 4 fine sand)
20Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
21Stainless steel bolts/square bar and plates Bolts.
22Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
23Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) Second class teak wood
24Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
25Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance >85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @ 80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size 24 x 24 X 3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge.With 20 mm thick beveled tegular mineral fibre false ceilingtile (NRC 0.7)
26Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood35 mm thick shutters
27Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
28Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)
29Providing and fixing ISI marked flush doors shutters conforming to IS :2202 (Part I) decorative type,core of block board construction with frames of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35mm thick including ISI marked stainless steel butt hinges with necessary screws.
30Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :125x85x5.5 mm (heavy type)
31Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm
32Providing and fixing finished brass 100mm mortice latch and lock with 6 levers and a pair of laver handles with necessary screws etc.complete (best make of approved quality):
33Providing and fixing bright finished brass handles with screws etc. complete 125mm
34Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade I Type II,in panelling fixed in aluminium doors,windows shutters and partition frames with C.P brass /stainless steel screws etc.complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative laminated on both side.
35Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc
36Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With brass cover plate minimum 1.25 mm thickness
37Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
38Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate ) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate
39Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Medium shade pigment using 50% white cement, 50% ordinary cement
40Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
41Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
42Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
43Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. .
44Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make , in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
45Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
46Wall painting with plastic emulsion painted of approved brand and manufactured to give an even shade: Two or more coats on new work
47Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
48Painting with synthetic enamel paintof approved brand and manufacture of required colour to give an even shade:Two and more coats on work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
49Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) Flame retardant face insulating board 12mm thick
50Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
51Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
52Providing and fixing precoated galvanised steel sheet roofingaccessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500-600mm)
53Providing and fixing precoated galvanised steel sheet roofingaccessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Barge board (upto 300mm).
54Providing and fixing precoated galvanised steel sheet roofinaccessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete: Gutter (600 mm over all girth).
55Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places: ACP Sheet Cladding
56Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
5712 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
58Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area
59Sanitary and plumbing
60Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
61Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
62Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board510x1040 mm bowl depth 225 mm
63Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm
64Providing and fixing white china closet squatting pan(Indian type) Orissa pattern W.Cpan of size 580x440mm
65Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan water closet 250x130x30mm
66Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 10 litre (full flush) capacity-coloured
67Providing and fixing G.I inlet connection for flush pipe connecting with W.C pan
68Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
69Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
70Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
71Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
72Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing:Oval shape 450x350mm (outer dimensions)
73Providing and fixing toilet paper holder :C.P. brass
74Providing and fixing soil,waste and vent pipes:100mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
75Providing and fixing soil,waste and vent pipes:75mm dia Centrifugally cast (spun) iron socketed pipe as per IS: 3989
76Providing and fixing bend ofrequired degree with access door,insertion rubber washer 3mm thick,bolt and nuts complete.100mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905.
7775mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
78Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
79Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.Concealed work including cutting chases and making good the walls etc.20 mm nominal outer dia Pipes
80Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.Concealed work including cutting chases and making good the walls etc. 25mm nominal outer dia.Pipes
81Providing and fixing brass bib cock of approved quality: 20 mm nominal bore
82Providing and fixing brass stop cock of approved quality 15mm nominal bore
83Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
84Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
85Septic tank
86Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas ( 30 cm in depth, 1.5 m in width as well 10 sqm on plan) including disposal of excavated earth, lead upto 50 mand lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
87Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -all work upto plinth level: 1:3:6 (1 Cement : 3 Coarse Sand 6: graded stone aggregate 40mm nominal size)
88Providing and laying in position specified grade of reinforced cement concrete excluding the cost of Centering,shuttering,finishing and reinforcement-All work up to plinth level:1:2:4(1cement :2coarse sand : 4graded stone aggregate 20 nominal size)
89Centering and shuttering including struting, propping etc. and removal of form for: Columns,pillars, piers, abutments, posts and struts.
90Reinforce for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
91Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1: cement :6 coarse sand)
92Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate ) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate
9312 mm cement plaster of mix :1:4 (1 cement :4 fine sand)
94Constructing brick masonry manhole in cement morter 1:4 R.C.C top slab with 1:2:4 mix,foundation concrete 1:4:8 mix,inside plastering 12mm thick with cement morter 1:3 finished with floating coat of neat cement and making channels in cement concrete 1:2:4 finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.I cover with frame (light duty)455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15kg) With sewer bricks conforming to IS:4885
95Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
96RCC Drain
97Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m Ordinary rock
98Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
99Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
100Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
101Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete aboveplinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more
102Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
103RCC Water Sump
104Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) includingdisposal of excavated earth lead upto 50 m and lift upto 1.5 m,disposed earth to be levelled and neatly dressed.All kinds ofsoil
105Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)
106Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 40 mm nominal size)
107Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
108Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
109Reinforcefor R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more
110Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete:40 mm thick with 20 mm nominal size stone aggregate
11112 mm cement plaster of mix:1:4 (1 cement: 4 fine sand)
112Interlocking pavar and Brick Edging
113Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.Cement mortar 1:6(1cement:6 coarse sand)
114Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
115Boundary wall
116Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.: Ordinary rock
117Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
118Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
119Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
120Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
121Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers.
122Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
123Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand).
1246 mm cement plaster of mix:1:3 (1 cement : 3 fine sand)
12512 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
12615 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
127Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
128Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
129Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete aboveplinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
130Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
131Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
132Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwovenwith horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire
133Entrance Gate
134Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas ( 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5 m,disposed earth to be levelled and neatly dressed. All kinds of soil.
135Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
136Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) atplinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)
137Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
138Providing and laying in position specified grade of reinforced cement concrete excluding the costof centering and shuttering finishing and reinforcement all work upto plinth level. 1:1.5:3(1 cement:1.5 coarse sand (Zone III): 3 graded stone agreegate 20mm nominal size)
139Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
140Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
141Reinforcefor R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more
14212 mm cement plaster of mix 1:4 (1 cement : 4 fine sand)
143Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
144Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
145Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
146Landscaping(Lawn)
147Grassing with selection No. 1 grass including watering and maintenance of the lawn for 30days or more till the grass forms a thick lawn,free from weeds and fit for mowing including supllyinggood earth ,if needed (the good earth shall be paid for separately) in rows 5cm apart in both directions
148Electrical Works
149POINT WIRING : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
150POWER/ LIGHT SOCKET WIRING:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
151Submain Wiring:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required: 4X 10 Sq.mm + 2 X 6 Sq. mm Earth Wire
152Submain Wiring:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as requiredL 2X 10 Sq.mm + 1 X 6 Sq. mm Earth Wire
153Submain Wiring:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required:2X 2.5 Sq.mm + 1 X 2.5 Sq. mm Earth Wire
154Submain Wiring:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required : 2 X 4 Sq.mm + 1 X 4 Sq. mm Earth Wire
155Submain Wiring:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required: 4 X 2.5 Sq.mm + 2 X 2.5 Sq. mm Earth Wire
156Submain Wiring:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required : 4X 4 Sq.mm + 2 X 4 Sq. mm Earth Wire
157Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair
158Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2Pair
159Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4Pair
160Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
161Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
162Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 3 run of cable
163Sub Head -III(Switchgear and earthing) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
164Sub Head -III(Switchgear and earthing) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
165Sub Head -III(Switchgear and earthing) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
166Sub Head -III(Switchgear and earthing) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
167Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A & 5/6 A modular socket outlet and 5/6A modular switch, connections etc. as required.
168Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
169Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
170Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125 mmX 125 mm)
171Supplying and fixing of horizontal type three pole and nuetral sheet steel MCB distribution board, 415Volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc., as required (but without MCB/RCCB/Isolator ) (Preferred Make : MDS Legrand) 4 way (4 + 12), Double door
172Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Preferred Make : MDS Legrand) 6 way, Double door
173Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc. as required. (Preferred Make : MDS Legrand)Single pole
174Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBomplete with connections, testing and commissioning etc. as required. (Preferred Make : MDS Legrand) :Single pole and neutral
175Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBomplete with connections, testing and commissioning etc. as required. (Preferred Make : MDS Legrand) Triple pole and neutral
176Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBomplete with connections, testing and commissioning etc. as required. (Preferred Make : MDS Legrand): Single pole blanking plates
177Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
178Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
179Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
180Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt ) as required.
181Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required
182Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
183Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
184Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
185Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
186Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
187Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
188Providing and fixing following rating and breaking capacityandpole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB
189Supplying, installing on wall, testing and commissioning offollowing capacity rising mains made of 1.6mm thick IP 42 sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current ratingin convenient sections and suitable for 415 V, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers,expansion joints, thrust pads including jointing and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TEC 439) 800 A (S.C. rating for 1 sec - 50 kA)
190Supplying, installation, Testing and commissioning of 34 watt 2X2 LED flat panel Recess mounting fitting , Environmental friendly, new generation, aesthetically designed , ultra modern recess mounting luminaire with high brightness SMD LED as light source, suitabl for Armstrong/Grid/POP ceiling, and fixing on ceiling with suitable clamps and nut bolts including giving connection testing etc., at site of work as required. (Similar to Havells make Pluto Neo Panel 2X2 - cat no PLUTONEO2X2PLR34WLED840S/857S or equivalent approved make Philips,Crompton,Bajaj )
191Supplying, installation, Testing and commissioning of 18 wattSlim Surface mounted square fixture in white finished with opal diffuser suitable for direct ceiling fixing with suitable clamps nuts bolts including giving connection testing etc., at site of work as required (Similar to Havells make 18 W LED 6000 K Cat No. LHEAAVP7IL1W018square type or equivalent make in Philips / Bajaj/ Crompton)
192Supplying, installation, Testing and commissioning of 12 W LED 6000 KwattSlim Surface mounted square fixture in white finished with opal diffuser suitable for direct ceiling fixing with suitable clamps nuts bolts including giving connection testing etc., at site of work as required (Similar to Havells make 12 W LED 6000 K Cat No. LHEAAVP7IL1W012 round type or equivalent make in Philips / Bajaj/ Crompton)
193Supplying, installation, testing andcommissioningof 20W Retrofit type Photon Ultra bright LED polycarbonate tubelight (Single side connection)along withIndustrial Box type Luminaire batten suitable for singleT8 LED Tube on wall/truss for fixing LED tube includng connection, testing as required.(Similar to CG make 20 W Retro LED T8cat no LT8-20-865-2 or equivalent in Philips / Bajaj/ Havells
194Supplying, installation, Testing and commissioning of 35 watt LED 5700K Post top lantern type Coral(Opal) - IP65 new generation post top , energy saving, environmental friendly, long life asthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required.(Havells make 35 watt LED 5700K type Coral (Opal) - IP 65 cat no CORALPT35WLED757PSYMTOPC or equivalent make in Philips / Bajaj/ Crompton)
195Supplying, installation, Testing and commissioning of 72 watt LED streetlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection with impact resisitance of IK07 and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required.(Similar to CG make 72 watt LED Nexus+ Street light cat no LSTP-72-CDL or equivalent in Philips / Bajaj/ Havells)
196Supply & fixing 1200mm ceiling fan IS I markedcapacitor type with double ball bearing suitable for single phase AC 230 volt 50Hz conforming to IS 374/1979 with amdt. No. 1 to 6 make Usha/Orient/Bajaja/Crompton etc.
197Supplying & Fixing of 300 mm dia sweep Exhaust Fan in the existing opening of wall suitable for single phase 230V 50Hz AC supply i/c connections etc., as reqd.Make: Almonard/ Crompton Greaves/ Bajaj
198Supply & fixing of 400 mm wall fan ISI Marked arerodynamically designed PP Plates with 3 No. of speed settingssuitable for single phase AC 230 volt 50Hzmake Usha/Orient/Bajaja/Crompton etc.
199Suppy installation Testing and Commisiioning of 1.5 Ton 5 Star Inverter Split Air Conditioner of Carrier make model ID: Carrier 1.5Ton 5 Star Emperia Pro 5 I inverter Split AC Product Code LARCARRIER-1-5-ENKA298272963F8973 Type Split AC. With warranty 1 Year Comprehensive, 10 years on Compressor and 2 Years on PCB, Refrigerant R- 410 A etc as required Make: Carrier, Voltas, Blue Star, Diakin,
200Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required.(Approved make:PolyCab/Finolex/Havells/V-Gaurd/Universal) 3 1/2× 95 sq.mm
201Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required.(Approved make:PolyCab/Finolex/Havells/V-Gaurd/Universal)4 × 10 sq.mm
202Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required.(Approved make:PolyCab/Finolex/Havells/V-Gaurd/Universal)4 × 16 sq.mm
203Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required.(Approved make:PolyCab/Finolex/Havells/V-Gaurd/Universal)3 × 10 sq.mm
204Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm.
205Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 35 sq. mm and upto 95 sq. mm
206Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.up to 35 sq.mm.
207Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 35 sq. mm and upto 95 sq. mm
208Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
209Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
210Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45 mm)
211Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (28mm)
212Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
213Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 10 sq. mm (22mm)
214Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 meter length along the pole for protection of under ground cable as required.
215Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required. 50 mm dia
216Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required. 100 mm dia
217Supplying of hot dip galvanized octagonal street light pole of 8m high with 70 mm to and 135 mm bottom dia with a base plate of 225x225x16 mm and a sheet thickness of 3mm fabricated from ISI approved pipes complete with pole cap and barcket for fixing the street light with necessary holes for entry and exit of wires at the appropriate places etc. complete as required at the site of work. ( Similar to Bajaj 8M Octogonal lighting pole or equivalent make)
218Painting of tubular steel street light pole with ISI approved paint as required
219Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 meter and upto 11.0 meter
220Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20 mm) of specified size and shape including form work, plastering if required, curing etc. as required. (volume of pole/ pipe not to be deducted)
221Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia
222Painting the synthetic enamel paint of approved brand and manufacture to give an even shade ( Zebra Painting of Pole coller with yellow and black enamel paints) Two or more coat on new work
223Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
224Supplying and fixing street light loop in loop out boxes with PVC sintex Box of size 6"x6"x4" with pvc enclosure 1 No. 6A SP MCB, 2/4 way strip connector i/c testing as reqd. (Make: Sintex)
225Supply and Fixing of floor mounted angle iron frame panel of overall size 1.2 m x 2.0 m fabricated from 50 x 50 x 6 mm angle iron with suitable extension of angle iron for gouting in the floor with adequate intermediate members of 50 x 6 mm flats including providing and fixing of following switch gears and their interconnection termination of cable with soldering lugs, nuts, bolts, drilling of holes, loop earthing, painting including the following items.(a) 200 Amp 4 P MCCB 36 KA -1 No. (b) 63 Amp 4P MCCB 25 KAwith metallic enclosure -4 Nos. (C ) 80 Amps 4P MCCB 25 KA with metallic enclosure- 3 Nos. (d) 25 Amps 4P MCCB 25 KA with metallic enclosure- 1 No. (e) 160 Amp on load Change Over- 1 No. (f)240 V AC base mounted analog timer with contactor of 32 Amps, (GIC)/(L&T) make - 1 No.,(g) 4 strip 300 Amp. Copper bus bar chamber - 1200 mm long - 1 set(h) Multi function Meter- 1 No. (i) Indicator 1 Set (j) Adaptor Box with Suitable size fabricated with 16 SWG MS Sheet as required for connection the switches Fabrication- 1 Set
226Supply of 66KW/82.5KVA SILENT Diesel Generating Set comprising of: “Cummins” Model 4BTAA3.9G4 Radiator Cooled, Diesel engine developing 110 BHP at 1500 RPM, with aluminium radiator complete with standard accessories. Coupled to: “Stamford” Alternator rated at 66KW/82.5KVA at 415 Volts, mounted on: Channel Iron Base Frame, Complete with: Fuel Tank of 185Ltrs capacity with Standard Manual Control Panel with Breaker, Batteries and Acoustic Enclosure.( Model should have 500 hrs or one year once oil change R servicing, 2 year warranty for the generator set and 5 year warranty for cylinder head, cylinder liner, crankshaft and connecting rod.)
227Erection & Commissioning Transportation, Unloading, Pit Interconnection, 20mtrs U.G. Cable (3.5c x 95 sqmm), 02mtrs Exhaust Pipe, 10mtrs GI & Copper Strip(25x3).
228Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
229Supplying, installation, testing & commissioning of manual callboxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
230Supplying, installation, testing & commissioning fire alarmsounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
231Supplying, installation, testing & commissioning sector panelsuitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 4 Zone
232Supplying and erection of CO2 fire extinguisher of 2 kg capacity conforming to relevant ISI Specification including fixing on suitable wall bracket
233Supply and Erection offire bucket of10 litre capacity on wall with suitable hook (conforming to relevant ISI Specifications)
234Supply of 2m x 1m x 6 mm thick corrugated rubber mat as required conforming to relevant ISI specification ( Suitable for electrical application)
235Providing and fixing First aid electric shock treatment chart with wooden frame of size 0.69mx0.52m and suitable glass of 2mm thick as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail