Repair, Maint And Improvement Of E/M Installation, Repair Of Dg Sets, Pump Motor At Alhilal Under Ge Palampur Repair, Maint And Improvement Of E/M Installation, Repair Of Dg Sets, Pump Motor At Alhilal Under Ge Palampur, Palampur-Himachal Pradesh

Military Engineer Services-MES has published Repair, Maint And Improvement Of E/M Installation, Repair Of Dg Sets, Pump Motor At Alhilal Under Ge Palampur Repair, Maint And Improvement Of E/M Installation, Repair Of Dg Sets, Pump Motor At Alhilal Under Ge Palampur. Submission Date for this Tender is 06-11-2021. Diesel Generators Tenders in Palampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29519478
Corrigendum : Repair, Maint And Improvement Of E/M Installation, Repair Of Dg Sets, Pump Motor At Alhilal Under Ge Palampur Repair, Maint And Improvement Of E/M Installation, Repair Of Dg Sets, Pump Motor At Alhilal Under Ge Palampur
Open Tender
Indian
Himachal Pradesh
Palampur
06-11-2021

Tender Details

Repair, Maint And Improvement Of E/M Installation, Repair Of Dg Sets, Pump Motor At Alhilal Under Ge Palampur Repair, Maint And Improvement Of E/M Installation, Repair Of Dg Sets, Pump Motor At Alhilal Under Ge Palampur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-11-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 18000.0 /-
Tender Value
INR 9 Lakhs /-

BOQ Items

Name of Work:REPAIR, MAINT AND IMPROVEMENT OF E/M INSTALLATION, REPAIR OF DG SETS, PUMP MOTOR AT ALHILAL UNDER GE PALAMPUR
Sl. No. Item Description
1Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in any type of soil, complete all as specified and directed.
2All as per ser item No 2 above butdepth exc 1.50 metre & n.exc 3.00metre.
3Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
4Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
5PCC 1:3:6 (nominal mix) type C-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed.
6Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using20 mm graded crushed stone aggregates) as inin lintels upto 1.5m clear span, cills, steps; seismic and othersimilar ands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating,includingnecessary formwork where required complete all as specified and directed.
7Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
8Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including taking out old bricks, complete all as specified and directed.
9Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with MS clamps, nuts and bolts required including taking out old pipe complete all as specified and directed.
10Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 50mm size fixed with MS clamps, nuts and bolts required including taking out old pipe complete all as specified and directed.
11Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 40mm size fixed with MS clamps, nuts and bolts required including taking out old pipe complete all as specified and directed.
12Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
13Painting to existing steel tubular HT poles, 11m/9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed
14Trimming of tree branches from LT overhead line to branch 2 mtr up to both side & re-stretching of ACSR conductor and earth wire of any size and type on LT poles including disconnecting and rebinding with insulators with suitable size of binding wire after restretching, connecting jumpers, adjusting line deviders and disposal tree branches complete includingremoving and refixing of UG cable /service wires to the ACSR conductor complete as directed by Engr-in-Charge . Note:- (i) Clearing branches from both sides of conductor in between two consequtive poles shall be considered as one span irrespective of distance between poles. (ii) Cost of T&P required for cutting and removing branches shall be deemed to be included in rate quoted by bidder.
15Cutting and removing grass,vegetation, creepers,small plants / bushes etc clamping up towards the poles and stays etc including cleaning bottom surface area of pole & stay not less than 1m x 1m by surface dressing of earth outside and inside substations, perimeter fencing around pump house area, and in drains surrounding area from site complete all as specified and directed.
16XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 120 sqmm 3.5 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
17XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area95 sqmm 3.5 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
18XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area70 sqmm 3.5 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
19XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area50 sqmm 3.5 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
20XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area35 sqmm 3.5 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
21XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area25 sqmm 3.5 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
22XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area16 sqmm 4 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
23XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 sqmm 4 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
24XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sqmm 2 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
25XLPE insulated, armoured electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 sqmm 2 core,laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly.
26Supply and spreding graded crushed stone aggregate 40mm size around two pole/ four pole structure in 15 cm thickness after cleaning area byremoving existing wild grass,vegetation,creepers, small plants / bushes etc complete all as specified and directed.
27Renewal of MCCB any size/ capacity with MCCB, 4 pole, 63 Amps, 16 KA, adjustable microprocessor release & suitable thimbless/ extended terminal with nuts, bolts and washers etc including minor required additional/ alternation for fixing and connecting up of MCCB all as directed by Engr-in-charge.
28Renewal of MCCB any size/ capacity with MCCB, 4 pole, 125 Amps, 25 KA, adjustable microprocessor release & suitable thimbless/ extended terminal with nuts, bolts and washers etc including minor required additional/ alternation for fixing and connecting up of MCCB all as directed by Engr-in-charge.
29Renewal of MCCB any size/ capacity with MCCB, 4 pole, 160 Amps, 25 KA, adjustable microprocessor release & suitable thimbless/ extended terminal with nuts, bolts and washers etc including minor required additional/ alternation for fixing and connecting up of MCCB all as directed by Engr-in-charge.
30Renewal of MCCB any size/ capacity with MCCB, 4 pole, 200Amps, 35/36 KA, adjustable microprocessor release & suitable thimbless/ extended terminal with nuts, bolts and washers etc including minor required additional/ alternation for fixing and connecting up of MCCB all as directed by Engr-in-charge.
31Renewal of MCCB any size/ capacity with MCCB, 4 pole, 250Amps, 35/36 KA, adjustable microprocessor release & suitable thimbless/ extended terminal with nuts, bolts and washers etc including minor required additional/ alternation for fixing and connecting up of MCCB all as directed by Engr-in-charge.
32Renewal of MCB any size/ capacity with MCB, TPN 63 Amps, AC, 415 volts with nuts, bolts and washers etc including minor required additional/ alternation for fixing and connecting up of MCB all as directed by Engr-in-charge.
33Renewal of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 25x20cm size, complete all as specified.
34Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32X6 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
35Preparation of old steel surfaces of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
36Disconnecing, taking down and stacking theunserviceable /broken earth wire /strip of any size from the roof or from wall and removing the same from the site all as directed.
37Air termination vertical type, Single pointed made with 12mm dia 300mm long aluminium rod including necessary fixing arrangements with aluminium bolts, nuts, lead wasters etc. complete and incl provisin of GI tubing light grade 40mm dia, 300mm longembedded in PCC block (size 30cm x 30cm x 30cm) one end and other end fitted with air termination rod all as specified and directed.
38Horizontal /down conductors, aluminium strip of size 25 x 3.15mm and includingepoxy insulator bus bar type 40mm thick at an interwal of60 cm apart for lightening protection on roof andfor down conductors, including all fixing arrangementsandaluminiun nut , bolt & washerscomplete all as per IS-2309-1989 and testing all as specified. Note :-Aluminium strip shall be jointed with rivets (minimum 4 Nos) .
39Test point terminal block made of gun metal or phosphorus bronzeof size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25mm long hex head screw for fixing the same on wall as as directed.
40Galvanised iron strip of size 32 x 6mm from earth pit to test point provided all around the bldg for lightening protection laid in trenches/fixed to walls on epoxy insulators with screws etc and connecting up complete all as directed..
41M&L , monthly Inspection, maintenance and serviceing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- (a)62.5 KVA Capacity, Make: Cummins,- 01 No (b)40 KVA Capacity, Make: Cummins-01 No (i) Checking engine oil level and topping up as and when required . Note: Oil shall be measures and paid separately (ii) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid seperately. (iii)Checking of air filter element (iv) Checking of exhaust system for leakage (v) Draining of sediment from fuel filter and fuel tank (vi) Cleaning of air cleaner element (vii) Checking engine alternator coupling, mounting bolts and alignment (viii) Tighting all nuts, bolts, in altenator terminal block (ix) Checking of alternator carbon brush and connections in alternator (x) Checking and tighting of all connection in DC control wiring.
42M&L required for Inspection, maintenance and servicing of DG Sets of following Capacities including alternator, electric panel board connection to DG set for routine check (B - Check) of DG set for smooth functioning and carrying out maintanance complete all as directed and specified.Note: (i) B-Check once in six month OR 250 Hrs running of DG set whichever is earlier.(ii) B- Check of all DG sets ones shall be paid as one Job(iii) All spare parts required shall be measured and paid separately as supply only ans existing make. (a)62.5 KVA Capacity, Make: Cummins,- 01 No (b)40 KVA Capacity, Make: Cummins-01 No
43Supply only Diesel filter (Primery & Secondary) suitable for 62.5 KVA DG Set
44Supply only Diesel filter (Primery & Secondary) suitable for 40 KVA DG Set
45Supply only Engine oil filter suitable for 62.5 KVA DG Set
46Supply only Engine oil filter suitable for 40 KVA DG Set
47Supply only oil pressure gauge.
48Supply only oil pressure switch.
49Supply onlywater temperature gauge.
50Supply onlyignition switch.
51Servicing and repair self starter 12 V for DG setincluding replacement of parts such as corban brushes, solonaid, rotor,washer, nut, bolts etc assembling the same and testingcomplete all as specified and directed by Engineer in charge.
52Dismantling the radiator and fan from the engine for cleaning of copper /aluminium tubes and cooling fins by using descaling solution (MAC solution) and soldering, patch work if required including repair of water pump assembly and replacement of defective parts of water pump and re-assembliying,testing complete 62.5 /40 KVA DG setcomplete all as specified and directed by Engineer in charge. Note : Fan blade shall be measured seprately as supply only.
53Supply & fix in replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 volt initially charged. Make :- EXIDE / AMRON / LUMINOUS
54Supply only Battary charger in AMF panel.
55Supply only battery terminal heavy duty of brass with nuts and bolts.
56Supply onlyDistilled water.
57Supply onlycoolant for raditor.
58Supply only20W 40 / 15 W 40 turbo synthetic superior quality engine oil Make : Kirloskar / Catrol / Volvoline/servo/HP/IOC
59Supply only fan belt of suitable size for 40/62.5 KVA DG Set compete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy