Power Development Department has published Survey, Design, Supply, Transportation / Carriage, Erection, Testing And Commissioning Of Ht / Lt Line & Creation Of Substation In Different Locations Ofpanchayat In Block Khoon & Block Majalta In District Udhampuron Turnkey Basis Under Ddc. Submission Date for this Tender is 15-10-2021. Bolts Tenders in District Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 12-Oct-2021 | Corrigendum for scope of work | Other | 15-10-2021 |
Sl. No. | Item Description |
1 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning of LT line in Block Khoon of DDC Constituency Khoon. |
2 | 8 mtr. long ST Poles(ST-410 SP15) |
3 | G.I.Mukki-Clamps Shackel Insulator |
4 | 0.03 ACSR Weasel Conductor |
5 | 16kNPolymer Shackle Insulators |
6 | Galvinized Nuts and Bolts. |
7 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT |
8 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
9 | LT Line Spacers |
10 | Anti- Climbing Device with Clamps |
11 | Painting of 8 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint |
12 | Painting of 8 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint |
13 | Danger Plates with Clamps |
14 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning of 11kvLine on 8 mtr PCC poles with Weasel Conductor for 25 KVA Sub Station at Mohra Talot (Balpur) pyt. Khoon |
15 | 8 mtr long PCC Pole (WL-200kg) |
16 | GI V Cross -arm with top Bracket including clamps |
17 | GI Channel X-arm including clamps and Angle for braces |
18 | 0.03 ACSR Weasel conductor |
19 | 11KV Pin Insulator(Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm |
20 | 11KV Disc Insulators(Polymeric 45KN ) creepage distance 320 mm with tension fittings |
21 | Galvanized Nuts and Bolts |
22 | Danger Plates with Clamps |
23 | Anti- Climbing Device with Clamps |
24 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm in HT Lines |
25 | Stone pad (300mmX300mmX75mm) |
26 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
27 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning of 25 KVA sub station at Mohra Talot (Balpur) |
28 | 11/0.433kV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate |
29 | Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type |
30 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
31 | 11 kV Horn GapFuse Set 3 Phase 200A |
32 | 70 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type |
33 | 9 mtr. Long ST Pole (ST-410 SP33) |
34 | 11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting |
35 | GI Channel/Angle/Flat of sizes including clamps |
36 | Galvinized Nuts and Bolts. |
37 | 32/63 amps TPN switch disconnected fuse unit |
38 | Cement bottoming of ST poles in 1:2:4 mix as per REC standards 0.5 Cum/Pole |
39 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
40 | Painting of 9 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint |
41 | Painting of 9 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint |
42 | Danger Plates with Clamps |
43 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning of LT lineson 8 mtr long PCC poles at Mohra Talot (Balpur) |
44 | 8 mtr. Long PCC Pole( WL- 200 kg) |
45 | G.I.U-Clamps |
46 | 0.02 ACSR Conductor Squirrel |
47 | 16kNPolymer Shackle Insulators |
48 | Galvinized Nuts and Bolts. |
49 | Danger Plates |
50 | Anti- Climbing Device with Clamps |
51 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm |
52 | Stone pad (300mmX300mmX75mm) |
53 | LT line spacers |
54 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
55 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning of 11kvLineat W.No. 7 Pyt. Thalora. |
56 | 8 mtr. long ST Pole (ST-410 SP-15) |
57 | GI V Cross -arm with top Bracket including clamps |
58 | GI Channel X-arm including clamps and Angle for braces |
59 | 0.03 ACSR Weasel Conductor |
60 | Galvanized Nuts and Bolts |
61 | Danger Plates with Clamps |
62 | Anti- Climbing Device with Clamps |
63 | 11KV Pin Insulator(Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm |
64 | 11KV Disc Insulators(Polymeric 45KN ) creepage distance 320 mm with tension fittings |
65 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm in HT Lines |
66 | Painting of 8 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint |
67 | Painting of 8 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint |
68 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioningfor Augmentation ofSubstation from 25 KVA to 63 KVA at W.No. 7 Pyt. Thalora. |
69 | 11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate |
70 | Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type |
71 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
72 | 11 kV Horn GapFuse Set 3 Phase 200A |
73 | 120 mm² Single-Core Cable, 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type |
74 | GI Channel/Angle/Flat of sizes including clamps |
75 | Galvinized Nuts and Bolts. |
76 | LT Distribution Box for 63KVA DTR with MCCB for incomer and SUF"s for outgoing circuits |
77 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
78 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
79 | Danger Plates with Clamps |
80 | Painting of 9 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint |
81 | Painting of 9 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint |
82 | Dismantling and carriage of old Transformers from site to DivisionalStore Udhampur |
83 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning of improvement of HT/LT in different panchayat of DDC Majalta |
84 | 8 mtr. long ST Pole (ST-410 SP-15) |
85 | G.I.Mukki-Clamps for Shackel Insulator |
86 | 0.03 ACSR Conductor Weasel |
87 | 16kNPolymer Shackle Insulators |
88 | Galvinized Nuts and Bolts. |
89 | Painting of 8 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint |
90 | Painting of 8 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint |
91 | LT Line Spacers |
92 | Anti- Climbing Device with Clamps |
93 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
94 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm |
95 | Danger Plates with Clamps |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail