Repair / Replacement Of Internal Electrification Including Replacement Of Led Light Fitting At Chunabhatti Md Accn Area And Repair / Rewinding Of Ceiling Fans Pedestal Fans / Exhaust Fans / Wall Mounting Fans / Geysers At Naval Station Karanja Repair / Re, GE NW KARANJA-Maharashtra

Military Engineer Services-MES has published Repair / Replacement Of Internal Electrification Including Replacement Of Led Light Fitting At Chunabhatti Md Accn Area And Repair / Rewinding Of Ceiling Fans Pedestal Fans / Exhaust Fans / Wall Mounting Fans / Geysers At Naval Station Karanja Repair / Re. Submission Date for this Tender is 20-10-2021. Electrical Maintenance Tenders in GE NW KARANJA Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

29334846
Corrigendum : Repair / Replacement Of Internal Electrification Including Replacement Of Led Light Fitting At Chunabhatti Md Accn Area And Repair / Rewinding Of Ceiling Fans Pedestal Fans / Exhaust Fans / Wall Mounting Fans / Geysers At Naval Station Karanja Repair / Re
Open Tender
Indian
Maharashtra
GE NW KARANJA
20-10-2021

Tender Details

Repair / Replacement Of Internal Electrification Including Replacement Of Led Light Fitting At Chunabhatti Md Accn Area And Repair / Rewinding Of Ceiling Fans Pedestal Fans / Exhaust Fans / Wall Mounting Fans / Geysers At Naval Station Karanja Repair / Replacement Of Internal Electrification Including Replacement Of Led Light Fitting At Chunabhatti Md Accn Area And Repair / Rewinding Of Ceiling Fans Pedestal Fans / Exhaust Fans / Wall Mounting Fans / Geysers At Naval Station Karanja

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 64000.0 /-
Tender Value
INR 32 Lakhs /-

BOQ Items

NAME OF WORK :REPAIR/REPLACEMENT OF INTERNAL ELECTRIFICATION INCLUDING REPLACEMENT OF LED LIGHT FITTING AT CHUNABHATTI MD ACCN AREA AND REPAIR/REWINDING OF CEILING FANS PEDESTAL FANS/EXHAUST FANS/WALL MOUNTING FANS/GEYSERS AT NAVAL STATION KARANJA
Sl. No. Item Description
1Taking down disconnecting and dismantling of ceiling fans including fan blades, down rod, coupling, decorative caps, condenser housing, stator and rotor for inspection and replacement of defective parts complete all as specified including complete overhaulings/greasing reassembling and testing to achieve satisfactory perfomance ,refixing after repair complete all as specified and directed by Engineer-in-Charge for the following stated below as (a)&(b) :-Note :- (a) Spare parts required shall be measured and paid separately as supply only under relevant items of this Schedule hereinafter.(b) Painting shall be measured & paid separately(c) Material required for overhauling such as grease, oil, etc shall deemed to be included in rate quoted.Ceiling fan of sweep 1200 mm
2complete all as item no 1 above but Ceiling fan of sweep 1400 mm complete all as specified and directed.
3complete all as item no 1 above but exhaust fan of size 300 to 450 mm sweep complete all as specified and directed.
4complete all as item no 1 above but air circulator wall mounted/ pedestal fan 400 mm 600 mm sweep complete all as specified and directed.
5Supply onlyBall bearing 6201 complete all as specified and directed.
6Supply only Ball bearing 6202 complete all as specified and directed.
7Supply only Capacitor (ISI marked) 2.5 mfd, Make : M/s Asian / M/s Crompton Greaves / M/s Usha / havells complete all as specified and directed.
8Supply only Canopy with fixing screw Make M/s Bajaj / M/s Crompton Greaves / M/s Usha complete all as specified and directed.
9Supply only Ceiling fan blade 1200 mm (48") sweep, suitable for M/s Crompton Greaves / M/s Orient / M/s Usha etc complete all as specified and directed.
10Supply onlyRubber bush for capacitor (as per sample) complete all as specified and directed.
11Supply onlySplit pin (as per sample) complete all as specified and directed.
12Supply only Rubber reel (as per sample) complete all as specified and directed.
13Supply only Shackle for ceiling fan with nut and bolts (ISI marked) complete all as specified and directed.
14Supply only Capacitor (ISI marked) 3.20 mfd complete all as specified and directed.
15Supply only Ball bearing 6203 complete all as specified and directed.
16Supply only Louver shutter of exhaust fan 300 mm sweep made of 16 gauge (as per sample) complete all as specified and directed.
17Ditto, all as per item No 16 above, but 375 mm sweepcomplete all as specified and directed.
18Ditto, all as per item No 16 above, but 450 mm sweep complete all as specified and directed.
19Supply only Ball bearing 6204 NBC
20Supply only Capacitor (ISI marked) 4 mfd, Make : M/s Asian / M/s Crompton Greaves / M/s Usha / M/s EFCOS complete all as specified and directed.
21M & L for preparation of old painted steel surfaces thoroughly and removing paint by hand scrapper to receive one coat of red oxide zinc chrome primer and two coats with deco white synthetic enamel paint by sprayingincluding numbering of MES No with max 7.5 mm size letter with black pfu paint complete all as specified for following fans :- Ceiling Fan 1200 mm / 1400 mm sweep
22complete all as item no 21 above but Exhaust Fan 300 mm to 450 sweep
23complete all as item no 21 above but Pedstal/wall mounted Fan
24M &L for copper rewinding of ceiling fan, with super enamelled copper wire of existing size and specifications replacement of bearing/bush, testing including taking down, fixing at site complete all as specified and directed for following sizes:-NOTE-Rewinding of fans to be done at MES store yard by opening small rewding workshop,providing rewinding machine etc. Ceiling Fan 1200 mm sweep
25complete all as item no 24 above but Ceiling Fan 1400 mm sweep
26complete all as item no 24 above but Exhaust fan 300 mm
27complete all as item no 24 above but Exhaust fan450 mm
28complete all as item no 24 above but wall mounted Fan 450 mm
29S& F in repair down rod approximate height of 6 feet long connected to ceiling to ceiling fan complete all as specified and directed. Make as per E-in-Cs Branch approved list class 1/A.
30S& F in repair down rod for 1200 mm ceiling fan connected to ceiling to ceiling fan complete all as specified and directed. Make as per E-in-Cs Branch approved list class 1/A.
31supply and fixing in repair fan regulator step type 230v either socket type or switch type as per the requirement of site and complete all as specified and directed by Engr-in-charge. Make as per E-in-Cs Branch approved list class 1/A.
32Rewinding of 5 HP motor of Chimney, contr will remove the motor from the existing chimney and fixing after rewinding, contr will quote the rate including transporation charges complete all as specified and directed.
33Taking down carefully old geysers 50 / 25 litres capacity of any make including dismantling and fixing of following part under item no 34 to 44 andwelding of tank unedr item no 45 refixing the geysers in the position after testing complete all as directed. The unit rate quoted shall be inclusive of fixing of spare parts and supply only sparts shall be measured and paid separately under relevant items of this schedule. NOTE FOR ITEM NO 34 to 44 The make of spare part shall be asas per PS.
34Supply only Heating element 2 KW suitable for operation on 230 V, AC, 50 Hz
35Supply only Thermostat for 50 liters capacity Geyser
36Supply only Thermostat for 25 liters capacity Geyser
37Supply only thrmo cut out for 25 Liters capacity Geyser
38Supply only Red/Green indicator, 230 volt (round/square) as required at site.
39Supply only Gasket set for 50 liters capacity Geyser
40Supply only Gasket set for 25 liters capacity Geyser
41Supply only PVC flexible connection for inlet for (cold water) with its connecting accessories (brass couplings), 0.60 m long, 15 mm dia, heavy duty (ISI marked) complete all as specified and directed.
42Supply only PVC flexible connection for outlet (hot water pipe) with its connecting accessories (brass couplings), 0.60 m long, 15 mm dia, heavy duty (ISI marked) complete all as specified and directed.
43Supply only Pressure release valve dead weight type for 50 liters capacity Geyser complete all as specified and directed.
44Supply only Pressure release valve dead weight type for 25 liters capacity Geyser complete all as specified and directed.
45After dismantling of geyser taking out copper tank transporting to welding shop soldering of leakage portion of tank and transporting to site,reassembling the geyser after filling of glass wool and connection complete all as specification and directed for the 25/50 ltr capacity geyser
46S & F in repairs / replacement earth plug and socket pole, neutral, sheet metal enclosures with a two pin, plug and socket 20 Amp, 240 volts as per Cat No DHDPUSNO20 of M/s Havells or equivalent of Make L&T, legrand/Standard with and including one MCB, SP, 20A, 240 volts complete all as specified . Make as per E-in-Cs Branch approved list class 1/A.
47M & L for Testing the tamper proof electric, KWH meter, disconeting of outgoing supply of residenc, checking the elect meter by applying artificialload, making the record in register, resealing the meter the meter properly, including replacing the damaged terminals, obtaining user signature on register for proper testing . sealing ofElectric Meter in presense of MES rep and Users repaintg of MES No on Engergy meter in Navy Nagar,NAD colony & Bazar area private party, maintain of Register as per direction by Eng-in-Charge complete all as specified and directed.
48Taking down carefully copper /aluminium point wiring (light, fan socket or power) through PVC casing caping/existing coduits includingcomplete fittings such as switches, ceiling roses, pendants, regulators, sockets, buzzer, bell, switch sockets,electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, all as specified and directed.
49M &L Pointwiringwith singlecore1100 voltsgrade 1.5 sqmm sizePVC FRLSinsulatedunsheathedstrandedcopperconductorcableusing color code drawn through & including PVC ,casingcapingwith allaccessoriesCompleteall asspecified in and including sunk type pressed steel/CI terminal box with 3mm thick hylam Mansonite sheet top cover/ PVC Boardincluding 1.5Sq mm PVC insulated unsheathed copper conductor cable for continous earth conductor (using green colour)to commen earth and connecting to earth dolly for the following .(a)One light /fan/ call bell point controlled by one switch
50Complete all as per item no49 above but One 5 pin socket outlet 5 Amps on independent board
51Complete all as per item no49 abovebut One 5 pin socket outlet5 Amps on same board
52Complete all as per item no 49 above butOne light point controlled bytwo way switch
53All as per item No 49 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSPVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board.
54Supply and fixing switch piano type flush button type single pole one way 5 Amps240V front operated. Make as per E-in-Cs Branch approved list class 1/A.
55S & F Switch socket combination 2 in 1 3 pin, 5 A and 15Amp flush type universal. Make as per E-in-Cs Branch approved list class 1/A.
56S & F Switch socket combination 2 in 1 3 pin 5 A flush type
57S & F Switch socket3 pin 5 A flush type. Make as per E-in-Cs Branch approved list class 1/A.
58S & F Bell buzzer 240v 50hz. Make as per E-in-Cs Branch approved list class 1/A.
59S & F Bell push 240v 50 hz. Make as per E-in-Cs Branch approved list class 1/A.
60S & F ceiling rose PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals.Make as per E-in-Cs Branch approved list class 1/A.
61S & F Lamp holder/angle holder insulated body with black/white plate for batten fittings. Make as per E-in-Cs Branch approved list class 1/A.
62S & F Electronic fan regulator step type electronic fan regulator flush type. Make as per E-in-Cs Branch approved list class 1/A.
63Supply and fixing in repair switch piano type flush button type single pole one way 5 Amps240V front operated. Make as per E-in-Cs Branch approved list class 1/A.
64S & F in repair socket outlet 3 pin 5 A flush type. Make as per E-in-Cs Branch approved list class 1/A.
65S & F in repair Switch socket combination 2 in 1 3 pin, 5 A and 15Amp flush type universal. Make as per E-in-Cs Branch approved list class 1/A.
66S & F in repair Switch socket combination 2 in 1 3 pin 5 A flush type. Make as per E-in-Cs Branch approved list class 1/A.
67Supply and fix in repairLED batten with 24W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten including dismantling of existing tube light as directed and specified by engr-in-charge. . Make as per E-in-Cs Branch approved list class 1/A.
68S&F double door MCB DB made out of 18 SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 2+6 way double door open able,including taking out old unsv MCB DB any size/type.
69S&F in repair double door MCB DB TPN 4 way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks,with thimble flame retardant copper conductors and200 Amps rated bus bar double door open able complete, including taking out old unsv MCB DB any size/type.
70S&F in repairMCB TPN 40-100A with breaking cap 16KA, 240V, 50 HZ Ac. Make as per E-in-Cs Branch approved list class 1/A.
71S&F in repair 6 to 32 AMP MCB single pole 240 V 10 KA(C-Series). Make as per E-in-Cs Branch approved list class 1/A.
72S&F in repair MCB SPN240 volts AC 40 to 63Amps (C-series)as per requirement of AMP directed by engr-in-charge. . Make as per E-in-Cs Branch approved list class 1/A.
73S&F6 to 32 AMP MCB single pole 240 V 10 KA(C-Series). Make as per E-in-Cs Branch approved list class 1/A.
74S&F MCB SPN240 volts AC 40 to 63Amps (C-series)as per requirement of AMP directed by engr-in-charge. . Make as per E-in-Cs Branch approved list class 1/A.
75M&L for wiring for circuits/sub main wiringwith FRLS PVC insulate sheathed 2 x 6 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into surface/concealed PVC conduit including laying of PVC conduit of 25mm dia with all accessories with 6 sqmm PVC insulated green copper cable for continues earthdolly complete all as specified and directed by Engr-in-charge.
76M&L for wiring for circuits/sub main wiringwith FRLS PVC insulate sheathed 2 x 4 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into surface/concealedincluding laying of PVC conduit of 25mm dia with all accessories with 4 sqmm PVC insulated green copper cable for continues earthdolly complete all as specified and directed by Engr-in-charge.
77Supply and fix in repair LED batten with LED tube light rod 10W 2 feet in wall / surface connecting with all required accessories like flexible cable from ceiling rose etc including dismantling of existing tube light as directed and specified by engr-in-charge. Make as per E-in-Cs Branch approved list class 1/A.
78Supply and fixing LED building security light fitting 45w IP 66 protectionLED. Make as per E-in-Cs Branch approved list class 1/A.
79Supply and fix GI tube light grade for making bracket suitable for fixing building security light of 45/60 Watt complete all as specified and directed by Engr-in-Charge. Make as per E-in-Cs Branch approved list class 1/A.
80Supply and fixing LED building security light fitting of 60w IP 66 protection complete all as specified and directed by Engr-in-Charge. Make as per E-in-Cs Branch approved list class 1/A.
81S & F in repairs MCCB 4 pole, thermal magnetic release range 100-125 Amps of breaking capacity 25 kA,415 Volts, 50 Hz,complete all as specified and directed by Engr-in Charge. Make as per E-in-Cs Branch approved list class 1/A.
82S & F in repairs MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 25 kA,415 Volts, 50 Hz,complete all as specified and directed by Engr-in Charge. Make as per E-in-Cs Branch approved list class 1/A.
83S & FLED tube rod 22 watt change with existing 36 watt tube rod complete all as specified and directed and directed by Engr-in Charge. Make as per E-in-Cs Branch approved list class 1/A.
84S & F in repair/replacement of old existing sunken/terminal box of size 10x10cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls all as specified and directed.
85S & F in repair/replacement of old existing sunken/terminal box of size 15x7.5cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls all as specified and directed.
86S & F in repair/replacement of old existing sunken/terminal box of size 20x25cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail