Certain Misc Br Repairs To Various Mes Installation Maintenance Cleaning Of Rcc Pvc Water Tanks Including Certain Repairs To Day To Day Internal Electrification Works Including Rewinding Overhauling Of Fan Of Various Md Accn At Phase Ii Area Under Ge Cert, GE NARANGI-Assam

Military Engineer Services-MES has published Certain Misc Br Repairs To Various Mes Installation Maintenance Cleaning Of Rcc Pvc Water Tanks Including Certain Repairs To Day To Day Internal Electrification Works Including Rewinding Overhauling Of Fan Of Various Md Accn At Phase Ii Area Under Ge Cert. Submission Date for this Tender is 20-10-2021. Electrical Maintenance Tenders in GE NARANGI Assam. Bidders can get complete Tender details and download the document.




Tender Notice

29334808
Corrigendum : Certain Misc Br Repairs To Various Mes Installation Maintenance Cleaning Of Rcc Pvc Water Tanks Including Certain Repairs To Day To Day Internal Electrification Works Including Rewinding Overhauling Of Fan Of Various Md Accn At Phase Ii Area Under Ge Cert
Open Tender
Indian
Assam
GE NARANGI
20-10-2021

Tender Details

Certain Misc Br Repairs To Various Mes Installation Maintenance Cleaning Of Rcc Pvc Water Tanks Including Certain Repairs To Day To Day Internal Electrification Works Including Rewinding Overhauling Of Fan Of Various Md Accn At Phase Ii Area Under Ge Certain Misc Br Repairs To Various Mes Installation Maintenance Cleaning Of Rcc Pvc Water Tanks Including Certain Repairs To Day To Day Internal Electrification Works Including Rewinding Overhauling Of Fan Of Various Md Accn At Phase Ii Area Under Ge

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work : CERTAIN MISC B/R REPAIRS TO VARIOUS MES INSTALLATION, MAINTENANCE / CLEANING OF RCC/PVC WATER TANKS INCLUDING CERTAIN REPAIRS TO DAY TO DAY INTERNAL ELECTRIFICATION WORKS INCLUDING RE-WINDING/OVERHAULING OF FAN OF VARIOUS MD ACCN AT PHASE-II AREA UNDER GE NARANGI.
Sl. No. Item Description
1SCHEDULE "A" PART-I
2Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., completeall as specified and as directed.
3S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with "L" type or "J" type or cranked hook bolts and washers, in roof covering, walls cladding etc, with grade of zinc coating 275 complete all as specified and as directed.
4Refixing only galvanised corrugated mildsteel sheeting as obtained from dismantling of old sheets here in before with two corrugation side lap, fixed with & including "L" type or "J" type or cranked hook boltsin roof covering, wall cladding etc., complete all as specified and as directed.
5S&F 0.8 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
6S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of colour as approved by GE having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
7S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by GE having tensile strength of 550 Mpa as in ridges,valleycomplete all as specified and as directed.
8Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed.
9S&F 6 mm thick asbestos cement corrugatedor semi corrugated sheetwith side lap, fixed with "L" or "J" type or cranked hook bolts, nuts & washers etc.complete all as specified and as directed.
10S&F 6 mm thick asbestos cement two piece adjustable serrated ridge, corrugated or semi corrugatedsheetfixed with "L" or "J" type or cranked hook bolts, nuts & washers complete all as specified and directed.
11S&F in repairs, suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic)in & including a grid of GI system duly suspended with 4mmdia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed.
12Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
13M & L for rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St.-240 complete all as specified and as directed.
14S&F rolled mild steel plates (plain or chequered) channels. square cut or notched (ordinary & counter sunk) forming holes, with riveted, bolted or welded attachment Fe 410-W(Gde-E-250) quality B complete all as specified and as directed.
15M & L for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing confirming to Fe 410-W (Gde-E- 250) quality-A complete all as specified and as directed
16S&F 1.25mm thick mild steel, plain, black sheet in cladding steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required completed all as specified and as directed.
17M & L for preparation of new steel surface over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
18M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
19Demolition of plain cement concrete (Un-reinforced) in ground floors and paving n exc 15cm thickness (below or above ground level) including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
20M&L for 100mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base for path/paving/hard standing/floor etc. complete all as specified and as directed.
21M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smoothwithout using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic jointfilling at every 3m length and at corners complete all as specified and as directed.
22M&L for 40mm thick PCC 1:2:4,type B1 (using 20mm graded stone aggregate) as in floor, finished the surface even and smooth with using extra cement complete all as specified and as directed.
23M & L for 25 mm thick PCC 1:2:4,type B0 (12.5 mm graded stone aggregate) as in floors finished the concrete surface even and smooth with using extra cement and pigment complete all as specified and as directed.Note : This item shall not be operated as sub base for floor tiles.
24Demolition of brick or stone masonry work built in cement mortarincluding all quoins, arches, pillars etc complete all as specified and as directed.
25M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
26All as per item No 24 here in before but except bricks. Note: Old serviceable bricks as obtained from demolitionhere-in-before shall be reused under this item complete all as specified and as directed.
27M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed.
28Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
29M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
30M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thickmixed with water proofing compound (@ 3% by weight of cement or as per manufacture"s instructions), finished even and smooth without using extra cement complete all as specified and as directed.
31M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
32M&L for preparation of old decorated surfaces of wallsand applying one coat of white wash complete all as specified and as directed.
33M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat ofprimer complete all as specified and as directed.
34M&L for preparation of old plastered surface of walls and applying one coats of exterior emulsion weather coat paint complete all as specified and as directed.
35Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed.
36M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
37M & L for colourednon-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid in floors etc.over and including 15 mm thick screed bedin cement motar 1:4, setand jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles,complete all as specified and as directed.
38M&L for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular )area of each tiles exc 0.18 sqm but not exceeding 0.38 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with colouredtilesover and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
39M & L for glazed ceramic tiles of size 300 mm x 200 mm x 6 to 7 mm thick colouredon vertical surfaces set, jointedin neat cement slurryand pointed in white cement mixed with colour pigments to match the colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as speciified and drected.
40Demolition of stone slab and tiles of any description or thickness in floor, apron etc laid, bedded and pointed in cement mortar complete all as specified and as directed.
41M&L for machine cut kota stone slab flooring 20 to 25 mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including 20 mm thick screed in cement mortar (1:6) including rubbing and polishing complete all as specified and as directed.
42M&L for machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with grey cement slurry mixed with pigment to match the shade of the slab fixed over and including 10mm thick screed bed in CM 1:4 including rubbing, polishing and treating the surface with beeswax polish etc complete all as directed.
43M&L for pre polished chequered cement concrete tiles in floor, area exc 0.06 Sqm but not exc 0.11 Sqm, 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including screed bed of 20 mm thick cement mortar (1:4)complete all as specified and as directed.
44S & F in repair 60 mm thick machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006M-35 Grade over and including 30 mm thick sand bed complete all as specified and as directed.
45Dismantling timber scantling 40Sqcm and over in section as in unframed workin any position complete all as specified and as directed.
46M&L for 2nd class hard wood, in scantlings, clean sawn timber as in unframed work complete all as specified and as directed.
47M & L for preparation of surfaces of wood and wood based surfacesnew or old of any description and girth not otherwise described and treating with two coats of creosote oil complete all as specified and as directed.
48Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm including builders hardware complete all as specified and as directed.
49Taking down chowkats or frames with shutters(without taking off shutters from the frame) area exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware complete all as specified and as directed.
50Taking down shutter of any descriptionarea exc 1 sqm but n exc 2 Sqm each including builders hardwarecomplete all as specified and as directed.
51S & F steel windows with side hung shutters glazed shutter including both side openable (out side glazed window and inside fly proof window)including projecting type hinges with steel handle and steel peg stay complete with glazing bars and 12 mm square bar or round bar of approved design welded to steel window frame dovetailed or welded complete all as specified and as directed .
52S&F aluminium anodised glazed shutter (single/double shutters) divided into two portion locking rail in middle as per Standard Engineering practices and section of Top and bottom rail 101.60x25x2.5mm thick (19556) lock rail section 150x44.45x2.65mm thick (20002) style section 85x44.45x2mm thick (19560) with aluminium glazing clip @ 0.154Kg/Rm (19377).Aluminium anodised frame rectangular section of size100x50x2.80mm thick (14087) alongwith cleat including other accessories like 5.5mm thick tinted glass , floor spring/hydraulic door closer, rubber beading, door handle, mortice lock 4 lever with handle shall deemed to be included in the quoted rate)
53S&F three track aluminium sliding window with approved make of following extruded section of anodised glazed shutter as per Standard Engineering practices including all other accessories complete like 5.00 mm thickglass panes, rubber beading, etc. complete all as specified and as directed.(Refer Jindal Cat M-2016 ) Aluminium sections : "A" series (i) Shutter bottom &top :- 37.50 x 15 x 1.3 mm thick (20690) (ii) Shutter interlock :- 37.50 x 23 x 1.3 mm thick (20689) (iii) Shutter side (Handle) :- 37.50 x 23 x 1.3 mm thick (20689) (iv) Frame bottom:- 75 x 26 x 1 mm thick (20671)(v)Frame top and sides :- 75 x 26 x 1 mm thick (20672)
54S&F 30mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
55M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
56M&Lfor preparation of old painted surfaces of wood or wood based materials of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
57S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed.
58S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
59S&F 150 mm long extruded aluminium alloy handles, cast type anodised complete all as specified and as directed.
60S & F 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionor cast aluminum alloy complete all as specified and as directed.
61S & F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
62S & F in repairs, stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
63S & F in repairs, aluminium door closer (Diecast) bodyhydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and complete all as specified and as directed.
64Hacking out old broken glass of any thickness, size quality or description from wooden frames glazed with putty or fixed with bead complete all as directed.
65S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding0.50sqm ineach pane complete all as specified and directed.
66Taking down steel rolling shutter, area of each shutter not exceeding 12.00 sqm each of any type and description including cover, anchoring rod, manual operated typeand carrying out neccessary repair/ replacement work to defective components such as pulling system , locking plate, guide channel, bracelet plate etc and reassembling the rolling shutter including greasing, welding, drilling where required and refixing the shutter in theexisting location and making functional to the entire satisfaction of the Engineer in charge complete all as directed.( Note:The materials replaced under this item shall be measured and paid seperately as " Supply only" underrelevent items of this schedule. The shutter shall be removed carefully alongwith its accessories without damaging the adjacent structure. All the defective parts to be repaired/ replacedunder this item shalllay out at site for proper verification and approval of the Engineer in charge and shall be repaired /Replaced only after prior approval of the Engineer in charge. Necessary greasingeasing will be done to the appropriate parts/ spares/ fixturesfor smooth functioning of the shutter.
67Supply only 100mm dia, 450mm long, SWG "O"high tensile spring, thickness not less than 8mm size conforming to relevent IS complete all as specified and as directed.
68Supply only roller of steel pipe ( shaft)heavy duty of size 50mm nominal bore complete all as specified and as directed.
69Supply only ball bearing No. 6213/6214 complete all as specified and as directed.
70Supply only locking plate made of 3.15mm thick mild steel reinforced with mild steel angle section of size 35x35x5mm complete all as specified and as directed.
71Supply only guide channel made of mild steel deep channel section not less than 3.15mm thick and depth of channel 75mm complete all as specified and as directed.
72Supply only mild steel clip suitable for rivetting to lath curtain complete all as specified and as directed.
73Supply only lath section 1.20mm thick for shutter width exceeding 3.50m conforming to IS-6248-1979 ( Section of lath shall have a distance of 75mm between rolling centre)complete all as specified and as directed.
74Supply only MS sheet 1.00 mm thick as in hood cover complete all as specified and as directed.
75M&L for preparation of old decorated steel or iron surfaces of any description over 10cm width or girth and applying one coat of aluminium paintcomplete all as specified and as directed.
76Dismantling posts or struts embedded in ground (wood, steel or R.C.C.) any section, including takingout embedded portion in natural ground and making good disturbed ground complete all as specified and as directed.
77Dismantling posts or struts embedded in concrete (wood, steel or R.C.C.) any section, including takingout embedded portion Concrete, brick work masonry, etc.and making good disturbed ground complete all as specified and as directed.
78S&F mild steel angle iron post & strut etc. in fencing including embedding in concrete and screwing etc. including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 GdeE-165 completed all as specified and as directed.
79M&L for providingreinforced cement concretetype B-1, 1:2:4(using 20mm graded stone aggregate) in precast posts, fencing post, straining or terminal posts, struts etc. for fencing, average sectional areaexceeding100 sqcm and n exc 250 sqcm with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and as directed. Note:- Reinforcement will be measured and paid seperately)
80M & L for PCC 1:3:6, type C2(using 40 mm gradedstone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
81M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mildsteel wire (annealed) not less than 0.9 mm dia as in reinforcement bar complete all as specified and as directed.
82M&L for mild steel TMT bars 6 mm dia and over upto and including 10mm diacut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed.
83Dismantling fencing wire mesh of any type complete all as specified and as directed.
84Supply only chain link fencing wire mesh of any size or type, made with 4 mm dia mild steel galvanised wire complete all as specified and as directed.
85Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolt etc including provision of binding wire complete all as specified and as directed.
86S&F in repairs, galvanized two strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia bars at 75 mm spacing and straining and fixing to RCC / steel post etc., including securing or tying at crossing with and providing of galvanized mild steel wire, staples or steel pins, etc., (each line of wire to be measured separately) complete all as specified and as directed.
87S & FGI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors including taking up/down old steel tubing complete all as specified and as directed.
88S & F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors including taking up/down old steel tubing complete all as specified and as directed.
89Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes etc of capacityupto 500 liter capacity tank using bleaching powder and writing the date of cleaning on water tank with white paint complete all as specified and as directed.
90M&L Cleaning and Removing all scale and dirt etc from tanks and from mouths of circulating pipes etc of capacity exe 500 liter but nexe 1000 liter tank capacityusing bleaching powder and writing the date of cleaning on water tank with white paint complete all as specified and as directed.
91S & F 500 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc including dismantling of old tank of any description complete all as specified and as directed.
92S&F in repairs, 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminiumrod& high density plastic ball screwed for iron pipe and fixed(Minimum weight20mm-210gms.) complete all as specified and as directed.
93S&F in repairs, bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
94M&L for welding in repairs n. exc 2.5cm in length & n. exc. 6mm thickness of metal to be welded complete all as specified and directed.
95M&L for running welding in repairsnot exceeding 6 mm thickness of metal to be welded complete all as specified and directed.
96Grubbing up tree trunk including cutting of trunk portion, girth of tree not exc 30 cm, protruding over ground / building / wall / root / chajja / stack pipes etc. digging out roots, and applying root killer chemical as per manufacturer"s instructions, filling holes with cement mortar (1:4) or PCC 1:2:4 type B-0 and removing the unserviceable materials from the site complete all as specified and directed
97Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
98M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
99Allas per item serial No 97 here-in-before butfor One light point controlled by 2- two way5 Amps switch
100Allas per item serial No 97here-in-before butfor One 3 pin 5 Amp switch socket outlet on independent board
101Allas per item serial No 97 here-in-before but for One 3 pin 5 Ampsocket outlet on same board with other switches.
102Allas per item serial No 97 here-in-before butfor One bell point controlled by one switch 5 Amps bell push.
103All as per item serial No 97 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
104M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC rigid conduit on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
105Allas per item serial No 103 here-in-before butfor One light point controlled by 2- two way5 Amps switch
106Allas per item serial No 103 here-in-before butfor One 3 pin 5 Amp switch socket outlet on independent board.
107Allas per item serial No 103 here-in-before butfor One 3 pin 5 Amp switch socket outlet on same board with other switches.
108Allas per item serial No 103 here-in-before butfor One bell point controlled by one switch 5 Amps bell push.
109All as per item serial No 103 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
110S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
111S&F in repairs, switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
112S&F in repairs, modular switch , flush type single pole one way 6 Amps 240 volt complete all as specified and as directed.
113S&F in repairs, switch piano, flush type single pole one way 15 Amps 230 volt complete all as specified and as directed.
114S&F in repairs, modular switch , flush type single pole one way 16 Amps 240 volt complete all as specified and as directed.
115S&F switch piano, flush type single pole two way 5 Amps 230 volt complete all as directed.
116S&F in repairs, switch piano, flush type single pole two way 5 Amps 230 volt complete all as specified and as directed.
117S&F bell push, flush type, 5 Amps complete all as specified and as directed.
118S&F in repairs, bell push, flush type, 5 Amps complete all as specified and as directed.
119S & F in repairs, modular Bell push 6 Amp 240 volts, flush typecomplete all as specified and as directed.
120S&F socket outlet 3 pin, 2-in-1, 5 Amps, flush typecomplete all as specified and as directed.
121S&F in repairs, socket outlet 3 pin, 2-in-1, 5 Amps, flush typecomplete all as specified and as directed.
122S&F in repairs, modular Socket outlet 2 in 1, 3 Pin 6 Amp flush type 240 volts complete all as specified and as directed.
123S&F in repairs, socket outlet 3 Pin 15 Amp 240 volts complete all as specified and as directed.
124S&F in repairs, modular Socket outlet 2 in 1, 3 Pin 6 Amp/16Amp flush type 240 volts complete all as specified and as directed.
125S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
126S&F in repairs, switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
127S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
128S&F in repairs, switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
129S & F lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
130S&F in repairs, lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
131S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
132S&F in repairs, ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
133S & Fstepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
134S&F in repairs,stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
135S&F in repairs, modular stepped type electronic fan regulator, two module size, flush typecomplete all as specified and as directed.
136S & F call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
137S&F in repairs, call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
138Dressing of pre-wired casing caping /PVC conduit of One light /fan/ exhaust fan point controlled by one number one way 5 Amp switch by changing Casing caping /PVC conduit and necessary connecting items (such as flexiable conduit , screws etc) complete all as specified and directed.
139Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6 inch x 10 inch MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with1.5 sqmm single core copper multistranded cable complete all as specified and as directed. (Note :New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items).
140Allas per item No138 here-in-above but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 8 inch MS box.
141Taking down carefully by unscrewing from board/outlet boxes, fitting and fixturessuch as switches, sockets,ceiling rose, lamp holders, brackets ceiling fitting ,bulkhead fitting, tube light fitting and regulator etc for reuse at site or carring to the store ( To be measured only when found in all respect complete for reuse) and making good disturbed surface of wall, flooretccomplete all as directed by Engineer-in-Charge.
142Refixing serviceable fittings/ fixtures as obtained from serial item no 140 here in before and connecting up with suitable size cableinlocation as directed by the Eng In charge .
143S&F in repairs, LED box type fitting of regal batten pre-wired including LED tube 1x20W ,fixed on PVC block connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cablecomplete all as specified and as directed. Make:- Havells Model-REGALBATTENT8UPTO1X22WDSBSWH +CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Philips /GE/Crompton
144S&F in repairs LED box type fitting pre-wired including LED tube 1x10W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable and fix on 2 no ofPVC blockcomplete all as directed. Make:- Jaguar Model-LGLZ01X010XC/ LGLZ01X010XN/LGLZ01X010XWor Make:- Havells Model-LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/Crompton
145S&F in repairs Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. Make:- HavellsModel HEXAFT10WLED857SSYMBOPC or equivalent Model of make : Philips /Crompton /G
146S&F in repairsLED (double sided connection) ) ultra bright polycarbonate tube light 18/20 watt retrofit in existing flourescent tube light. Make Havells/crompton/Bajaj/Jaquar or euivalent.
147S&F in repairs wall mounteddecorative luminaire in design mesh suitable for 9W LED lampB22 base ,including lamp15watt complete all as specified and as directed. Make -Havells, cat no-LHDL07150099 or equivalent in crompton, Bajaj, Jaquar
148S&F in repairs,MCCB DB IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make-Legrand Cat No-5077 45 or equivalent of Siemens/Schnider/L&T)
149S & F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way,protection class IP-43with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed . Make :- Legrand Cat No 5076 70 or equivalent. model in Siemens / Schneider
150S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
151S & F in repairs, single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 10 or equivalent model in Siemens / Schneider/L&T
152S&F in repair for MCCBs 415 V, 16 KA, 4P, 63 Amps complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
153S&F in repairs,MCB TPN40 to 63Amps, 415V,50 HZ,C series breaking capacity 10KA complete all as specified and as directed. Make- Legrand ,cat part no-4086 81 to 83 equivalent model of make Siemens/Schnider.
154S&F in repairs, MCBs, SPN 6 to 32 Amps, 10 KA,"C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
155S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, "C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :-Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
156Disconnecting the main power supply to distribution box and make a proper dressing of SPN/TPN/VTPN MCB/MCCB DBs ofpre-connected MCBsby changingscrew of DB cover ,earth wire and other necessary connecting items and dressing of wires with the help of cable tie inside the distribution box after completion supply power complete all as specified and directed.
157Dismantling old electric kWH meters carefully by disconnecting all electric connection and re-fixing after necessary repair of electric energy KWH meter single phase 05 to 60 Amps, including making connection of incomming and outgoing wiring circuits and submission of KWH reading details of old unserviceable taken down meter complete all as directed.
158Supply,installing,connecting and testing AC single phase static energy meter of Accuracy class 1.0, 240V,50Hz with backlit LCD display,of rating 10 to 60 Amp(Measure and displays in kWhV,I,kW,PF Last month history of kWh & Md in kW) with special features like TOD, Tamper logging,Optical communication port & display in absence of power with transparent hinge type box including taking dowm old meter and depositing the same in MES store yard of AGE E/M complete all as specified and directed. Make- HPL/L&T/SECURE .
159S & F in repairs, SMC Mild steel (Deep Drawn & Fabrication ) Polycarbonate meter box of suitable size accommodate 4 nos of three phase meter per box ,anticorrosive ,dust proof,rust proof ,shock proof self extinguishing property .resistance to heat,vermin & water proof ,ultra voilet stabilized and pilfer resistance including push fit locking system conforming to SMC materials ,IS: 14772 complete all as specified and as directed. Make -RMC/Sintex
160M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.)
161M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
162M&L for frabricationg angle iron frame of size 18 inch x 24 inch using 30x30x5mm angle iron firmly grouted in wall surface using support and fixing 6mm thick flameproof Hylem sheet of size 19 inch x 25 inch on top for mounting 4 Nos electric energy meters single phase, including making good to damaged surface as per existing and making necessary electrical connection using 6.0 sqmm single core copper multistranded cable through PVC conduit from MCB DB box to incomming of meter and outgoing connection of submain circuit wiring complete all as directed. (Note : Quoted rate includes making all incoming and outgoing electrical connections using PVC insulated mulitstranded copper conductor wire of size 6.0 sqmm through PVC conduit pipe in gray color from MCB DB to Electric meters.)
163Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook,and transportingto MES E/M store yard,and refixing on same location or other locationcomplete all as specified and as directed.( Cost of repairing including replacement of spares if any will be measured and paiid seperatelyunder relevent items of this schedule.
164Strip opening of ceiling fan1200 /1400 mm sweep, cleaning thoroughly bush & ball bearing by petrol, washing/cleaning fan blades with caustic soda thoroughly, provision of fresh greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same and testing the fan on full load to entire satisfaction of Engineer-in-Charge. Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
165Cutting the existing copper winding of AC ceiling fan1200 mm//1400mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size includingprovision of twisted twin core flexible wire upto 0.7 metres long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete includingsatisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
166Supply only ball bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI
167Supply only condenser ISI marked 230/240/250 volts AC 2.5 Mfd suitable for ceiling fan. (Make : Usha/Asian/EPCOS/Universal).
168Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and as directed.
169Supply only down rod 15mm dia GI pipe heavy duty 45 cm long including machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and as directed.
170Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and as directed.
171Taking down exhaust fan of size 200mm to 300mm sweep of any make and transporting from any locationto MES E/M store yard, and refixing on same location or other location carefully after repairing,washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same includingprovisionof twisted twin core flexible wire upto 0.7 meterslong size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Chargecomplete all as specified and as directed. Note:- Cutting the existing copper winding, rewinding, Replacement of defective/ unserviceable parts if required shall be measured and paid separately under respective items .
172Cutting the existing copper winding of AC exhaust fan200mm to 300mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size includingprovision of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) all insulating materials incl varnishing, heating and drying complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
173Supply only ball bearing suitable for exhaust fan 300 mm sweep complete all as specified and as directed.Make : NBC/SKF/SBBI
174Supply only condenser ISI marked 230/240/250 volts AC 4.0 Mfd suitable for exhaust Fans complete all as specified and as directed.(Make : Usha/Asian/EPCOS/Universal).
175S&F in repairs exhaust fan louver of out side building including making necessary arrangement like ladder/scaff holding etc and drilling of hole for fitting of exhaust fan louver complete all as specified and directed.
176S&F in repairs,ventilating fans AC single phase 230/ 240 V of size 250 mm sweep with louver shutter with frame and necessary fixing accessories , writing MES No. with black synthetic enamel paint2 cm high in letter complete with necessary connection upincluding provision of three core copper flexiblecable with flexible wire cover of plastic white in colourand connection from ceiling rose to exhaust fan terminaletc complete all as specified and as directed. Make-Usha, Model-CRISP AIR LX EXHAUST FAN or equivalent make in Crompton, Baja Note: old ventilating fan shall be deposit to E/M yars.
177M & L for painting of ceiling/exhaust fan complete with blades ,in situ with synthetic enamel paint Duco by spraying including filling cavities with filler ,ones coat after cleaning all dust etc.complete all as specified and as directed.
178S&F in repair telephonic wire used in home unit for smart meter ,4 wire RJ11 complete all as specified and as directed.
179M&L for plate earthing completewith galvanizedmild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrodeat one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm boreGIpipe medium gradewith all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-Iincluding demolition of old earthing
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy