Repairs Maintenance Of Internal Wiring Dbs Submain Wiring Fittings And Fixtures At Ins Dega And Ins Eksila Under Age Em Of Ge Nd Visakhapatnam Repairs Maintenance Of Internal Wiring Dbs Submain Wiring Fittings And Fixtures At Ins Dega And Ins Eksila Under, Visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Repairs Maintenance Of Internal Wiring Dbs Submain Wiring Fittings And Fixtures At Ins Dega And Ins Eksila Under Age Em Of Ge Nd Visakhapatnam Repairs Maintenance Of Internal Wiring Dbs Submain Wiring Fittings And Fixtures At Ins Dega And Ins Eksila Under. Submission Date for this Tender is 29-10-2021. Electrification Work Tenders in Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29334492
Corrigendum : Repairs Maintenance Of Internal Wiring Dbs Submain Wiring Fittings And Fixtures At Ins Dega And Ins Eksila Under Age Em Of Ge Nd Visakhapatnam Repairs Maintenance Of Internal Wiring Dbs Submain Wiring Fittings And Fixtures At Ins Dega And Ins Eksila Under
Open Tender
Indian
Andhra Pradesh
Visakhapatnam
29-10-2021

Tender Details

Repairs Maintenance Of Internal Wiring Dbs Submain Wiring Fittings And Fixtures At Ins Dega And Ins Eksila Under Age Em Of Ge Nd Visakhapatnam Repairs Maintenance Of Internal Wiring Dbs Submain Wiring Fittings And Fixtures At Ins Dega And Ins Eksila Under Age Em Of Ge Nd Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Sep-2021 Amendment Financial Bid 15-10-2021
2 15-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-10-2021
3 23-Oct-2021 Due Date Extended Admin Corrigendum Date Extend 26-10-2021
4 27-Oct-2021 Due Date Extended Admin Corrigendum Date Extend 29-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 48 Lakhs /-

BOQ Items

Name of Work: REPAIRS / MAINTENANCE OF INTERNAL WIRING, DBs, SUBMAIN WIRING, FITTINGS & FIXTURES AT INS DEGA AND INS EKSILA UNDER AGE E/M OF GE [ND] VISAKHAPATNAM
Sl. No. Item Description
1The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- [i]The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time. [ii]The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE. [iii]Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places. [iv]The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work).
2M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area)1100V grade drawn through and including PVC conduit of size 20mm dia medium grade (surface/ concealed) including accessories fixed on wall/floor/roof, etc including provision of 2.0mm thick prefabricated galvanised boxes white modular cover plate and frame of suitable size for fixing modular switches, sockets, regulator, etc including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell point controlled by one switch including taking down old point wiring with fittings & fixtures complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for necessary cutting chases in walls / floors / ceiling of any description, pinning in making good to disturbed surfaces where required and pointing in cement mortar 1:3 and finished to match with existing finishes complete]
3All as per item No. 2 above but suitable for one5 Amps socket point on independent board
4All as per item No. 2 above but suitable for one5 Amps socket point on same board
5All as per item No. 2 above but point wiring with4.0 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.
6M & L for Point wiring with FRLS grade PVC insulated unsheathed multistranded copper conductor cable 1.5 Sqmm (nominal area) 1100V grade drawn through and including stove enamelled steel conduit of size not less than 25mm dia including accessories fixed on wall/floor/roof, etc with MS terminal boxes made out of 2.0mm thick mild steel sheet including provision of FRLS grade insulated, unsheathed multistranded copper conductor of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for flame proof switches/sockets of any type for One light / fan point / Bell / 5A socket point controlled by one, one way switch including taking down old point wiring with fittings & fixtures and making good to the disturbed surfaces of wall / ceiling to match with existing finishes complete all as specified and directed.
7All as per item No. 6 above but point wiring with4.0 Sqmm (nominal area) suitable for one flame prrof 15/16 Amps switch socket point on independent board complete all as specified and directed.
8S & F modular switch 1 way, 6 Amps, 1 module
9S & F modular switch 1 way, 16 Amps, 1 module
10S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
11S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
12S & F modular fan regulator, 120W, 2 module, step type, complete all as specified and directed.
13S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
14S & F in repairs Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified
15S & F in repairs Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified
16S & F LED tube light fittings, retro bar professional WH 5700K to 6200K and minimum 1800 to 2000 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
17S & F LED tube light fittings, 2 feet long of 900 to 1000 lumens of cool white wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
18S & F Square recessed mounted LED light (1"x1") of minimum 1500 Lumens cool day light / warm white as required at site with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
19S & F Square recessed mounted LED light (2"x2") of minimum 3600 Lumens cool day light / warm white as required at site with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
20S & F Slim design recessed round LED down light fitting with 1200 lumens output of power consumption and integral driver with all accessories duly prewired with and including suitable size copper conductor including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
21S & F Slim design recessed round LED down light fitting with 1800 lumens output of power consumption and integral driver with all accessories duly prewired with and including suitable size copper conductor including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
22S & F flood light 9000 to 10000 lumens new generation LED with high luminous efficacy, Pressure die cast aluminium housing IP 66 protection, front toughened glass, energy savingwith all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
23S & F highbay light 12000 lumens new generation LED with high luminous efficacy, Pressure die cast aluminium housing IP 66 protection, front toughened glass, energy savingwith all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
24S & F highbay light 15000 lumens new generation LED with high luminous efficacy, Pressure die cast aluminium housing IP 66 protection, front toughened glass, energy savingwith all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
25S & F Building Security light LED type of minimum 3000 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
26S & F in repairs LED bulb 7 watts non dimmable pin type complete all as directed
27S & F CMRI certified flame proof Weather proof LED tube light fittings of not less than 4000 lumens output, 5700K, PF>0.95 with pressure die cast aluminium housing IP-65 protection heat resistance toughened glass cover, electronic driver with all accessories internally prewired connecting with flexible copper conductor of size 1.5 Sqmm including taking down existing light fittings complete all as directed.
28S & F CMRI certified flame proof Weather proof LED bulk head fittings of not less than 4000 lumens output, 5700K, PF>0.95 with pressure die cast aluminium housing IP-65 protection heat resistance toughened glass cover, electronic driver with all accessories internally prewired connecting with flexible copper conductor of size 1.5 Sqmm including taking down existing light fittings complete all as directed.
29Taking down existing ceiling fan of any type and sweep from any position and refixing the same in original / new location after necessary servicing, cleaning for dust, grease including replacement of minor spares such as bushes, bearings, canopy, capacitors, fan clamps etc as required at site and applying two coats of synthetic enamel paint (spray painting) including filling the cavities with filler and writing MES Nos on the fans complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans]
30M & L for removing defective / burnt out winding of ceiling fans of any capacity and rewinding with super enamelled copper winding wire of suitable size including replacement of insulating materials such as laminated lethroid paper, sleeves and varnishing complete all as specified and directed by the Engineer-in-Charge.
31Taking down existing Exhaust fan of any type and sweep from any position and refixing the same in new / old position after necessary over hauling / servicing and cleaning for dust, grease including replacement of minor spares such as bushes, bearings, capacitors, etc as required at site and applying two coats of synthetic enamel paint (spray painting) including filling the cavities with filler and writing MES Nos on the fans complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans]
32M & L for removing defective / burnt out winding of Exhaust fan upto 380mm sweep and rewinding with super enamelled copper winding wire of suitable size including replacement of insulating materials such as laminated lethroid paper, sleeves and varnishing complete all as specified and directed by the Engineer-in-Charge.
33M & L for removing defective / burnt out winding of Exhaust fan 450mm & 600mm sweep and rewinding with super enamelled copper winding wire of suitable size including replacement of insulating materials such as laminated lethroid paper, sleeves and varnishing complete all as specified and directed by the Engineer-in-Charge.
34Taking down existing Air circulator / Pedestal fanof any type and sweep from any position and refixing the same in new / old position after necessary over hauling / servicing and cleaning for dust, grease including replacement of minor spares such as bushes, bearings, capacitors, etc as required at site and applying two coats of synthetic enamel paint (spray painting) including filling the cavities with filler and writing MES Nos on the fans complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans]
35M & L for removing defective / burnt out winding of Air circulator / Pedestal fan motor of 450/600mm sweep and rewinding with super enamelled copper winding wire of suitable size including replacement of insulating materials such as laminated lethroid paper, sleeves and varnishing complete all as specified and directed by the Engineer-in-Charge.
36S F in repairs MCCB, 3 Pole, 63 Amps, 415 Volts, 50Hz of breaking capacity 25 KA with all necessary aluminium lugs and glands, etc complete all as directed
37S F in repairs MCCB, 3 Pole, 100 Amps, 415 Volts, 50Hz of breaking capacity 25 KA with all necessary aluminium lugs and glands, etc complete all as directed
38S F in repairs MCCB, 4 Pole, 125 Amps, 415 Volts, 50Hz of breaking capacity 25 KA with adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as directed
39S F in repairs MCCB, 4 Pole, 160 Amps, 415 Volts, 50Hz of breaking capacity 25 KA with adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as directed
40S F in repairs MCCB, 4 Pole, 250 Amps, 415 Volts, 50Hz of breaking capacity 36 KA with adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as directed
41S F in repairs MCCB, 4 Pole, 400 Amps, 415 Volts, 50Hz of breaking capacity 36 KA with adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as directed
42S & F in repairs factory made sheet metal enclosure double door VTPN DBs (fixed flush to the wall) with provision for MCCB, 160 Amps as incomer and outgoing as TPN, 8 way, 415 Volts, IP-43 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed. [Note: MCCB shall be measured and paid seperately]
43S & F in repairs factory made sheet metal enclosure double door VTPN DBs (fixed flush to the wall) with provision for MCCB, 125 Amps as incomer and outgoing as TPN, 4 way, 415 Volts, IP-43 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed. [Note: MCCB shall be measured and paid seperately]
44S & F in repairs factory made sheet metal enclosure double door TPN MCB DBs (fixed flush to the wall), 4 way, 415 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.
45S & F in repairs factory made sheet metal enclosure double door SPN MCB DBs (fixed flush to the wall), 8 way, 240 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.
46S & F in repairs MCB, SP, 6 to 32 Amps, 240 Volt, rupturing capacity 10 KA, 50 Hz, "C" series complete all as directed
47S & F in repairs MCB, SPN, 6 to 32 Amps, 240 Volt, rupturing capacity 10 KA, 50 Hz, "C" series complete all as directed
48S & F in repairs MCB, TP, 63 Amps, 415 Volt, rupturing capacity 10 KA, 50 Hz, "C" series complete all as directed
49S & F in repairs MCB, TPN, 63 Amps, 415 Volt, rupturing capacity 10 KA, 50 Hz, "C" series complete all as directed
50M & L for sub main wiring with 4 runs of single core 1100 volts grade, 10.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including 40mm dia surface/concealed /semi concealed PVC conduit and conduit accessories including provision of 1 run of 10.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 5 runs of 10.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
51M & L for sub main wiring with 2 runs of single core 1100 volts grade, 6.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including 25mm dia surface/concealed /semi concealed PVC conduit and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 3 runs of 6.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
52M & L for sub main wiring with 2 runs of single core 1100 volts grade, 4.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including 25mm dia surface/concealed/semi concealed PVC conduit and conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 3 runs of 4.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
53M & L for sub main wiring with 2 runs of single core 1100 volts grade, 2.5 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including 20mm dia surface/concealed/semi concealed PVC conduit and conduit accessories including provision of 1 run of 2.5 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 3 runs of 2.5 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
54Supply, laying and testing LT XLPE insulated, PVC sheathed, bedded, armoured, heavy duty, electric power cables of size 4 core 25 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct complete all as specified and directed by the Engineer-in-Charge.
55Supply, laying and testing LT XLPE insulated, PVC sheathed, bedded, armoured, heavy duty, electric power cables of size 4 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct complete all as specified and directed by the Engineer-in-Charge.
56Supply, laying and testing LT XLPE insulated, PVC sheathed, bedded, armoured, heavy duty, electric power cables of size 3.5 core 95 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct complete all as specified and directed by the Engineer-in-Charge.
57Supply, laying and testing LT XLPE insulated, PVC sheathed, bedded, armoured, heavy duty, electric power cables of size 3.5 core 70 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct complete all as specified and directed by the Engineer-in-Charge.
58Supply, laying and testing LT XLPE insulated, PVC sheathed, bedded, armoured, heavy duty, electric power cables of size 3.5 core 50 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct complete all as specified and directed by the Engineer-in-Charge.
59Supply, laying and testing LT XLPE insulated, PVC sheathed, bedded, armoured, heavy duty, electric power cables of size 3.5 core 35 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct complete all as specified and directed by the Engineer-in-Charge.
60Supply, laying and testing LT XLPE insulated, PVC sheathed, bedded, armoured, heavy duty, electric power cables of size 4 core 10 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct complete all as specified and directed by the Engineer-in-Charge.
61Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
62Returning filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed.
63Removing excavated material /soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
64M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
65Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat of size 250mm x 150mm x 40mm for cable protection laid across alignment of cable in trenches complete all as specified and directed.
66S & F GI tubing 50mm bore, light grade for cable protection laid in trenches / walls complete all as specified and directed.
67M & L for cutting of road / hard standing for laying of cables / cable protection pipe and making good the disturbed portion in PCC 1:3:6, type C-1 using 20mm graded stone aggregate including removal of debris to a distance not exc 50m complete all as specified and directed.
68S & F Starter for shutter 3 Phase DOL type suitable for rolling shuuter / hanger door motor two way revolving type (clockwise and anticlockwise both type) including taking down defective startercomplete all as directed by Engineer-in-Charge.
69S & F Starter for shutter 3 Phase DOL type suitable for pump of capacity 7.5HP including taking down defective startercomplete all as directed by Engineer-in-Charge.
70S & F limit switch 10A-125, 250 or 480 Volts, AC suitable for rolling shutter / hanger door for three phase supply including taking down defective limit switch complete all as directed by Engineer-in-Charge.
71S & F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified.
72S & F in repairs Aluminium strip 25x3.15mm as roof conductors and down conductors buried in ground / fixed on wall with means of hylam sheet with epoxy based insulator and screws, bolts, nuts and lead washers complete all as specified and directed.
73S & F in repairs Test point terminal box of size 200x100x100mm made of 2mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with test point terminal block made of gun metal or Phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screwsand secured to wall complete all as specified and directed.
74M & L for Servicing of rolling shutter / hanger door motor of 7.5 HP capacity by opening, cleaning, and rewinding the motor with appropriate gauge super enameled copper wire, varnishing with golden colour varinish, drying, greasing, replacement of insulating materials, sleeves, worn out shaft bush, condenser, bearings, chain link and sprocket, nuts & bolts, split pins and refixing the motor in original position, painting (two coats of existing colour) including testing and commissioning complete all as specified directed by the Engineer-in-Charge
75M & L for Servicing of fire booster pump motor of capacity upto 7.5 HP by opening, cleaning, and rewinding the motor with appropriate gauge super enameled copper wire, varnishing with golden colour varinish, drying, greasing, replacement of insulating materials, sleeves, worn out shaft bush, condenser, bearings, chain link and sprocket, nuts & bolts, split pins and refixing the motor in original position, painting (two coats of existing colour) including testing and commissioning complete all as specified directed by the Engineer-in-Charge
76S & F in repairs Wall mounted alternating current plug and socket distribution box (Industrial socket) including plug connector 16 Amps, 2 pole and earth, IP 40 protection of metal body single phase 240 Volts, 50 Hz with provision for one 16 Amps MCB 2P including necessary fixing arrangements complete all as directed by the Engineer-in-Charge.
77S & F in repairs Wall mounted alternating current plug and socket distribution box (Industrial socket) including plug connector 32 Amps, 3 pole, neutraland earth, IP 40 protection of metal body single phase 415 Volts, 50 Hz with provision for one 32 Amps MCB TPN including necessary fixing arrangements complete all as directed by the Engineer-in-Charge.
78S & F in repairs sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed.
79S & F Aviation Obstruction light of LED type integral light comprising of aluminium housing with polycarbonate enclosure, 302 Nos LED along with other fixing accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down existing light fittings of any type complete all as specified and as directed by the Engineer-in-Charge.
80Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m for indoor LT panel complete all as directed
81Supply and replacement of LED driver suitable for 36 Watt LED panel light (2"x2") of and type complete all as directed
82Supply and replacement of LED driver suitable for 25/30 Watt LED street light of and type complete all as directed
83Supply and replacement of LED driver suitable for 18 Watt LED square and round recess light of and type complete all as directed
84S & F in repairs switch socket combination 2 pin & 3 pin, 5 Amps, 230 volts multipurpose complete all as specified and directed.
85S & F in repairs switch socket combination 2 in 1 type, 3 pin, 5/15 Amps, 230 volts multipurpose complete all as specified and directed.
86S & F in repairs GI powder coated louvers suitable for exhaust fans upto 300mm sweep complete all as directed. [Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height]
87S & F in repairs GI powder coated louvers suitable for exhaust fans above 300mm sweep and upto 600mm sweep complete all as directed. [Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height]
88S & F 2mm thick GI hot dip galvanised / powder coated perforated type cable trays of size 100mm width, 50mm depth fixed with and including necessary MS clamps, nuts, bolts fixed to walls / ceiling including taking down old tray complete all as directed by the Engineer-in-Charge.
89S & F PVC cable tray of size 100mm width, 50mm depth fixed with and including necessary MS clamps, nuts, bolts and cover fixed to walls / ceilingincluding taking down old cable tray complete all as directed by the Engineer-in-Charge.
90S & F PVC cable tray of size 50mm width, 50mm depth fixed with and including necessary MS clamps, nuts, bolts and cover fixed to walls / ceilingincluding taking down old cable tray complete all as directed by the Engineer-in-Charge.
91S & F uPVC panel trunking system 75mm width, 75mm depth elongated flexible bottom mounting fixed with and including necessary end joints, T bends, and other accessories, MS clamps, nuts, bolts and cover fixed to walls / ceilingincluding taking down old trunking complete all as directed by the Engineer-in-Charge.
92Supply, install, connect, test and commissioning of 3 Phase, 4 wire, 50Hz, 415 Volts, outdoor type, LT panel of suitable size made of 3.15mm thick CRCA sheet including angle iron frame, cubical type, dust and vermin proof, factory made with front and rear opening double door with locking arrangement 415 volts, aluminium bus bar of 300 Amps for phase and 300 Amps for neutral insulated with PVC sleeves insulation and panel foundation with 2 pillars in PCC 1:3:6 type C-2 minimum 300mm under ground and 450mm over the ground level including MC 75 MS channel frame medium grade at base of the pnel with 4 Nos bolts 200mm long 16mm dia grouted in PCC suitable for acommodating and including the following components as per CPRI norms complete all as specified and directed:- [a] MCCB, 4 Pole, 250 Amps, 50 Hz, 415 Volts, 25KA (with Adjustable TM range) - 01 No [b] MCCB, 3 Pole, 125 Amps, 50 Hz, 415 Volts, 25KA (with Adjustable TM range) - 02 No [c] MCCB, 3 Pole, 160 Amps, 50 Hz, 415 Volts, 25KA (with Adjustable TM range) - 01 No [d] MCCB, 3 Pole, 63 Amps, 50 Hz, 415 Volts, 16KA (with Adjustable TM range) - 01 No [d] LED indication lamp [R Y B] - 01 Set [e] Digital Ammeter 0 to 200 Amps with inbuilt selector switch and CTs - 01 No [f] Digital Voltmeter 0 to 500 Volts with inbuilt selector switch - 01 No [g]Wiring with copper conductor - 1 set
93Supply, install, connect, test and commissioning of 3 Phase, 4 wire, 50Hz, 415 Volts, outdoor type, LT panel of suitable size made of 3.15mm thick CRCA sheet including angle iron frame, cubical type, dust and vermin proof, factory made with front and rear opening double door with locking arrangement 415 volts, aluminium bus bar of 200 Amps for phase and 200 Amps for neutral insulated with PVC sleeves insulation and panel foundation with 2 pillars in PCC 1:3:6 type C-2 minimum 300mm under ground and 450mm over the ground level including MC 75 MS channel frame medium grade at base of the pnel with 4 Nos bolts 200mm long 16mm dia grouted in PCC suitable for acommodating and including the following components as per CPRI norms complete all as specified and directed:- [a] MCCB, 4 Pole, 160 Amps, 50 Hz, 415 Volts, 25KA (with Adjustable TM range) - 01 No [b] MCCB, 3 Pole, 100 Amps, 50 Hz, 415 Volts, 16KA (with Adjustable TM range) - 01 No [c] MCCB, 3 Pole, 63 Amps, 50 Hz, 415 Volts, 16KA (with Adjustable TM range) - 03 Nos [d] MCCB, 3 Pole, 40 Amps, 50 Hz, 415 Volts, 16KA (with Adjustable TM range) - 04 No [d] LED indication lamp [R Y B] - 01 Set [e] Digital Ammeter 0 to 200 Amps with inbuilt selector switch and CTs - 01 No [f] Digital Voltmeter 0 to 500 Volts with inbuilt selector switch - 01 No [g]Wiring with copper conductor - 1 set
94Supply, install, connect, test and commissioning of 3 Phase, 4 wire, 50Hz, 415 Volts, indoor type, LT panel of suitable size made of 3.15mm thick CRCA sheet including angle iron frame, cubical type, dust and vermin proof, factory made with front and rear opening double door with locking arrangement 415 volts, aluminium bus bar of 300 Amps for phase and 300 Amps for neutral insulated with PVC sleeves insulation and panel foundation with 2 pillars in PCC 1:3:6 type C-2 minimum 300mm under ground and 450mm over the ground level including MC 75 MS channel frame medium grade at base of the pnel with 4 Nos bolts 200mm long 16mm dia grouted in PCC suitable for acommodating and including the following components as per CPRI norms complete all as specified and directed:- [a] MCCB, 4 Pole, 250 Amps, 50 Hz, 415 Volts, 25KA (with Adjustable TM range) - 01 No [b] MCCB, 3 Pole, 100 Amps, 50 Hz, 415 Volts, 16KA (with Adjustable TM range) - 02 No [c] MCCB, 3 Pole, 63 Amps, 50 Hz, 415 Volts, 16KA (with Adjustable TM range) - 03 Nos [d] MCCB, 3 Pole, 40 Amps, 50 Hz, 415 Volts, 16KA (with Adjustable TM range) - 05 No [d] LED indication lamp [R Y B] - 01 Set [e] Digital Ammeter 0 to 200 Amps with inbuilt selector switch and CTs - 01 No [f] Digital Voltmeter 0 to 500 Volts with inbuilt selector switch - 01 No [g]Wiring with copper conductor - 1 set
95M & L for Chemical earthing by drilling of hole upto 250mm dia to a depth not less than 3.5m and fixed sealed maintenance free chemical filled earthing electrode 17.2mm dia and 3.048m long with copper coating thickness 254 microns including supply and installation of CAPE make earth enhancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7-25Kg buried directly and vertically in the hole with top edge not less than 1.25m below normal ground level connected with copper earth strip 30x6mm by means of bolts, nuts, check nuts and washers of copper connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, refilling the earthing hole including earthing lead upto 7.5m complete all as specified in SSR Part-I and all as per manufacturers instructions.]
96Earthing complete with Copper plate electrode of size 600x600x3mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to Copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 32mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
97Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth strip 25x4mm by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
98Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth lead 4mm dia by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, Precast RCC 1:2:4, Type B-1 cover 40mm thick reinforced with 8mm dia CTD bars @ 75mm c/c both ways, MS handle12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
99S & F Earth continuity conductor or main earthing lead of 25x4mm GI strip fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified.
100S & F Earth continuity conductor or main earthing lead of 20x3mm copper strip fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified.
101M & L for cutting required size of holes in the existing brick / stone masonry wall for fixing exhaust fans of any size including making good disturbed surfaces in CM 1:3 and finish the surface to match with adjoining surface finish complete all as directed
102Removing ceiling light fittings of 4"x1" from any location and fixing the same in new location including cutting the existing false ceiling board of any type and making good surfaces by filling the cavities with similar board and putty work complete all as directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail