Electrical Renovation And Compound Illumination Work Of District Judge Bungalow In The District Of Bankura-Compound Illumination Of District Judge And Cjm Court, BANKURA-West Bengal

Public Works Department-PWD has published Electrical Renovation And Compound Illumination Work Of District Judge Bungalow In The District Of Bankura-Compound Illumination Of District Judge And Cjm Court. Submission Date for this Tender is 27-10-2021. Electrification Work Tenders in BANKURA West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

29333084
Electrical Renovation And Compound Illumination Work Of District Judge Bungalow In The District Of Bankura-Compound Illumination Of District Judge And Cjm Court
Open Tender
Indian
West Bengal
BANKURA
27-10-2021

Tender Details

Electrical Renovation And Compound Illumination Work Of District Judge Bungalow In The District Of Bankura-Compound Illumination Of District Judge And Cjm Court

Key Value

Document Fees
Refer document
EMD
INR 28880.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:- Electrical renovation and compound illumination work of District Judge Bungalow in the District of Bankura-Compound illumination of District Judge And CJM Court.
Sl. No. Item Description
1Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wallas per GS( Make - Legrand/L&T/Havells ) 12Way( Up to 160 A ) [15 / D- 11 ]
2Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand/L&T/Havells]6-32 TPN[ 8 / D- 7]
3Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kAin existing Vertical DBs including necessary connection as per GS[ Make - Legrand/L&T/ABB ].160 A FP [10/D- 8 ]
4Supplying and fixing SPDs (Surge Protection Devices)----Type 2,I 70kA ,Conforms to IEC 61643-11,• Type 2 : Protection against indirect lightning and switching surges• - Maximum Discharge Current - Imax up to 70kA of existing VTPN DBs and necessary connectionas per GS [ Make -Legrand/ABB/L&T ] Cat no- AUSP023PN70(3P+N)/ L&T or Equivelent
5Supply and Fixing Timer MULTIFUNCTION TIME SWITCH Application Suitable for Residential and Commercial use. Range-16 A Specification-IEC 60730-1/IEC 60730-2-7(cat-no- DHTLB01016)/ (3P-1N) [ Make -Legrand/L&T/Havells]
6Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS 50mm dia [11(d)/F-6]
7SUB-HEAD 13 -- COMPOUND LIGHT Inter connection of LED light fittings by 2 x 1.5 Sq. mm. PVC insulated copper wire from pole loop box with 19mm best quality PVC pipes as perdirection of EIC
8Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixedpaint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole1st coat of aluminium paint over 1 coat of RO priming and 2nd coat of aluminium paint over 1st coat as per GS
9S& F sheet metalLoopbox of size 8""x6"x2 1/2" made of 14 SWG CRC Sheet with Hing type door and door locking arrangementincl S&F 250 V3 way AC/DCmake bakeliteterminal in conceal in in wallafter cutting the wall & mending good damage as per dir of EIC
10SUB-HEAD - 1 : ERRECTION OF POLE Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary,With 200x150x100mm 16 SWG GI Loop Box(I-1/13(b))
11SUB-HEAD - 2 : S& LAYING OF CABLE & WIRES Supply of4/3.5 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Fort Gloster/KEI]2 Core 10 Sq. mm[ NS ]
124 Core 10 Sq. mm [ NS ]
134Core 16 Sq. mm [ NS ]
14Laying of cableafter cutting floor/pavement/wall as per GS for the following Sizes. 2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
15Laying of cable upto 35 sqmm in underground trenchas per GS for the following numbers of Cables.1 No Cable[ 1(a)/ F- 2 ]
16Supplying and fixing compression type gland and finishing thoseforfollowing XLPEarmoured cable (2/4 / 3.5)Core as per GS.2 Core 10 Sq. mm [7(c)/F4 & 8(b) /F5]
174Core 10 Sq. mm [7(c)/F4 & 8(b) /F5]
184Core 16 Sq. mm [7(c)/F4 & 8(b) /F5]
19Supplying and Drawing 1.1 KV single core stranded "FR" PVC insulated & unsheathed single core stranded coppe wire of following sizesin 13 mm dia polythene pipe through the steel tubular pole for connecting the street light fittings. 2 X 1.5 SqMM
20SUB-HEAD -4 : SUPPLY & DELIVERY OF STREET LIGHT FITTINGS Supply and Delivery of Street LED light fitting included with all accessories and lamps as specifiedbelow.( Make - Havells/PHILIPS/CROMPTONS ) -with 5 (Five) Years Warranty48 Watt Fittings[ Cat No-.Endura Pearl Neo-ENDURAPEARLNEOSL48WLED757PASYTOPC)
2180 Watt Fittings[ Cat No.-Endura cityliner Neo-ENDURACITYLINERNEOMPSL80WLED757PASYBOTG ]
22Supply and Delivery of Flood LED light fitting included with all accessories and lamps as specifiedbelow.( Make - Havells/PHILIPS/CROMPTON ) -with 5 (Five) Years Warranty50 Watt Fittings [ Cat No. JETA QUANTO PLUS-JETA QUANTOPLUSFLP50WLED757SYMLENS]
2370 Watt Fittings [ Cat No. Jeta PRO 70-JETA PROFL70WLED757LT G]
24Supply & delivery of single phase Split type inveter Airconditioner,capacity 1.5TR, 05 star rating.ISEER Value-4.55 ,special Features-Antibacterial coating,Dust Filter,Dehumidifiers,Air purifier, Noise Level-34dB,Annual Energy Consumption-less than 1KWH (Make- HITACHI/O-general/DIAKIN)(Model No-RSOG518ICEA or Equivalent)
25supply delivery of pocket ucermalfor electrical safty cheking and ensuing safty. The immager hoke to be radio metric,should have 120x90 pixel infrad resolutaion (10800 pixel),measure from -20 degree c to +150 degree c( make- Fluke) cat no-PTi120 pocket general imager.