Providing Internal Electrification Including Fans, Fittings, Ac Units And Geyser At District Magistrate ( Darjeeling ) Bunglow, Pintail Village, Dist. Darjeeling, Sliguri-West Bengal

Siliguri Jalpaiguri Development Authority-SJDA has published Providing Internal Electrification Including Fans, Fittings, Ac Units And Geyser At District Magistrate ( Darjeeling ) Bunglow, Pintail Village, Dist. Darjeeling. Submission Date for this Tender is 08-10-2021. Electrification Work Tenders in Sliguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

29332433
Providing Internal Electrification Including Fans, Fittings, Ac Units And Geyser At District Magistrate ( Darjeeling ) Bunglow, Pintail Village, Dist. Darjeeling
Open Tender
Indian
West Bengal
Sliguri
08-10-2021

Tender Details

Providing Internal Electrification Including Fans, Fittings, Ac Units And Geyser At District Magistrate ( Darjeeling ) Bunglow, Pintail Village, Dist. Darjeeling

Key Value

Document Fees
Refer document
EMD
INR 17675.0 /-
Tender Value
INR 8.83 Lakhs /-

BOQ Items

Name of Work: Providing Internal Electrification including fans, Fittings, AC Units & Geyser at District Magistrate (Darjeeling) Bunglow, Pintail Village, Dist. Darjeeling
Sl. No. Item Description
1Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. (a)Average run 5 mtr
2Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) including S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall including mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC (a) On Board
3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required : Group A
4Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) a) 19mm dia 3mm thick Polythene Pipe
5b) 25mm dia 3mm thick Polythene Pipe
6c) 32mm dia 3mm thick Polythene Pipe
7Supplying and Drawing 1.1 KV single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. (a) 3 x 22/0.3 (1.5 sqmm)
8(b) 3 x 36/0.3 (2.5 sqmm)
9(c)4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC
10Supply & Fixing 240 V, 6 A, 3 pin Modular type plug Socket (Brand approved by EIC) with 6A Modular type Switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
11Supply & Fixing 240 V, 16 A, 3 pin Modular type plug Socket (Brand approved by EIC) with 16A Modular type Switch with Indicator Lamp, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
12Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
13Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate including making necessary connections etc.
14Supply & Fixing 240 V, 25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
15Supply & Fixing Modular type RJ45 sitable for CAT6 cable (Brand approved by EIC) on existing PVC board and top cover plate on wall and making necessary connections as required
16Supplying & Fixing 240 V AC/DC superior type Multitune (min 10 nos. tune) Call Bell (Anchor) with selector switch for single/Multi Tunes mode, Battery operated on HW board incl. S&F HW board
17Supplying & Erection of Decorative Ceiling fan of 1200 mmsweep, suitable for operation on 230 Volts, single phase, 50 Hz, AC Supply including 300 mm long down rod etc. as required. ( Without Regulator )(Make: Orient /Bajaj /USHA-Striker/Luminous).
18Supplying & Erection of Ceiling fan of 900 mmsweep, suitable for operation on 230 Volts, single phase, 50 Hz, AC Supply including 300 mm long down rod etc. as required. ( Without Regulator )(Make: Orient /Bajaj /USHA-Striker/Luminous).
19Supplying and fixing of 300 mm heavy duty body & blade exhaust fan complete with louvershutter to be fixed on wall after making hole & mending good all damages including necessary connection & earthing attachments. (Make:Orient. Model: Industrial Heavy Duty or equivalent model of EPC / USHA)
20Supplying andr fixing of Round or Rectangular shaped Fresh Air/ Ventilator fan having less sound including making connection etc. as required. (Make: Orient. Model: 10" Ventilator or equivalent model of USHA / Luminous)
21Supplying & Fixing of 400 mm sweep wall fan with front guard, regulator incl. making connection etc. as required. (Make: Orient. Model:Wall 47 or equivalent model of Crompton / USHA)
22Supplying & Fixing of Round Based having minimum dia 550 mm and height maximum 275 mm with stainless steel finish crystal Chandelier having at least 5 nos. LED lamps with G9 base on the celing etc. as required. (Make: Philips. Model: CAMEO 581849 or equivalent model of Jaquar / Bajaj)
23Supplying and fixing of decorative crystal wall lamp with clear glass having chrome finish with LED lamp base suitable for 240 V etc. as required. (Make: Philips. Model: 40947 DEW WALL LAMP or equivalent model of Jaquar / Bajaj)
24Supplying & Fixing of Single Spot light of maximum dimensions 120 x 90 x 65 mm having 4 Watt lamp etc. as required. (Make: Philips. Model: 56240 or equivalent model of Jaquar / Bajaj)
25Supplying & Fixing reading light suitable to fix bedside easy to adjustable having goose neck arm of LED 3 Watt lamp etc. as required. (Make: Philips. Model: 48042 Bedside Lights or equivalent model of Jaquar / Bajaj)
26Supplying & fixing of metal desk / table lamp with elegance finish and adjustable head having On/ Off switches for base and light suitable for reading having 7 Watt LED lamp etc. as required. (Make: Philips. Model: 58156 Desk Lights or equivalent model of Jaquar / Bajaj)
27Supplying & Fixing of Mirror Light IP44 rating maximum 7.5 Watt LED Lamp & base etc. as required. (Make: Philips. Model: 34034 Jojoba or equivalent model of Jaquar / Bajaj)
28Supplying & Fixing of 240V LED Strip Light with Aluminium Profile 19/20 mm in size of different colour having minimum 750 LM / metre etc. as required. (Make: Philips. Model: Pro Glow por equivalent model of Jaquar / Bajaj)
29Supplying & Fixing of Surface Round Ceiling light having 290 mm dia and maximum 60 mm height with 12 Watt LED light etc. as required. (Make: Philips. Model: 31814 or equivalent model of Jaquar / Bajaj)
30Supplying & Fixing of Step/ Foot Light of Maximum height of 40 mm with 2 W LED Lamp base etc. as required. (Make: Philips. Model: 30974 or equivalent model of Jaquar / Bajaj)
31Supplying & Fixing of IP65 Wall Washer both upwards and downwards with Aluminium body LED Lamp with Lens etc. as required. (Make: Philips. Model: 58159 Gamma Light or equivalent model of Jaquar / Bajaj)
32Supplying & Fixing of LED Bulkhead pressure diecast housing with IP66 Protection and IK09 Impact resistance suitable for surface and wall mounting applications etc. as required. (Make: Philips. Model: WT202W or equivalent model of Jaquar / Bajaj)
33Supplying & Fixing of Recessed Type metal housing Downlighter with below given wattage having surge protection upto 2 KVand heat resistance on high temperature etc. as required : (a)7 Watt (Make: Philips. Model: Aura Style Edge Downlighter7 W or equivalent model of Jaquar / Bajaj)
34Supplying & Fixing of Recessed Type metal housing Downlighter with below given wattage having surge protection upto 2 KVand heat resistance on high temperature etc. as required : (b)10 Watt (Make: Philips. Model: Aura Style Edge Downlighter10 W or equivalent model of Jaquar / Bajaj)
35Supplying & Fixing of LED Bollard square shaped with stainless steel finish having height 450 mm long with 9 Watt LED lamp and E-27 lamp base etc. as required.(Make: Philips. Model: 16414 or equivalent model of Jaquar / Bajaj)
36Supplying, installation, testing and commissioning ofSurface type Single 1200mm LED Battenluminaire with 1 Nos. 20/18 watt LED Tube (Minimum 115 Lumen / Watt) made out CRCA / Polycarbonate body on ceilingincluding making connection etc. as required.(Make: Philips . LED Batten Cat No. TMC 501 P 2XT-LED 22W P3242 & LED tube 1200 mm Cat No.- 18W865 T8 I - 2100 lmor equivalentSurya / Havells / Bajaj / Crompton).
37Supplying & Fixing of IP43 Aluminium Diecast decorative LED Post Top lantern with transperant glass diffuser including making connection etc. as required. (Make: Jaquar. Model: Monaco 340.33.NGG or equivalent model of Philips / Bajaj)
38Supplying & Fixing of 20 W Pendant LED on the Office table including making connection etc. as required. (Make: Philips. Model: 31145 Pendant or equivalent model of Jaquar / Havells)
39Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (a) 8 way ; Legrand
40b) 6 Way; Legrand
41c) 4 Way; Legrand
42Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make: Legrand. Upto 160 A : 4 Way.
43Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. FP 63A.Make: Legrand
44Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (a) FP 40 A. (Make: Legrand)
45Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.TP 40 A. (Make-Legrand)
46Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. SP 6-32 A. (Make: Legrand)
47Supply of 1.1 KV grade XLPE insulated PVC Sheathed Aluminum conductor armouredCable2 core 10 Sq.mm (Conforming to IS - 7098 (Part 1) : 1988) (Make: Incab / CCl / Gloster / Crystal / Polycab / Havells)
48Supply of High Density Poly-ethylene Pipe conforming to IS - 4984 - 1985 (Dia) [PE - 63]A. 6 Kg / Sq.Cm. (Working Pressure) (Dia) 40 mm (PWD - 2017,Plumbing works, Page 19, Item 20)
49Labour for fitting and fixing high density poly-ethylene pipes or P.V.C. pipes for above ground work including cost of jointing materials paints etc. fitting and fixing all necessary specials, cutting pipes, making threads, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps(any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials.) (B) Under Ground: (v) 40 mm dia.(PWD - 2017,Plumbing works, Page 12, Item (18 B) )
50Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
51Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
52Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
53Extra for treatment of soil by using salt & charcoal or coke for plate electrode
54Supplying, Installation, Testing and Commissioning of 1.5 TonSplit TypeAir-conditioning system having 3 Star rating including supplying and fixing Angle IronFrame for Out Door Unit, Wooden Frame for Indoor Unitetc.as required. (Make: DAIKIN. Model: FTL50TV16U2 or equivalent model of Hitachi / Panasonic / Voltas)
55Supply and Fixing of Additional Copper Pipe with necessary Jacketing, Soldering etc. as required.
56Supply and Fixing of Water Drainage Pipe incl. all accessories etc. as required.
57Supplying & laying of 2.5 sqmm 3 core unarmoured Copper Cable along with necessary items etc. as required.
58Supplying & Installation of 15 Ltr. Capacity Geyser on the existing wall including necessary clamp / support including making connection etc. as required.
59Labour Welfare Cess @ 1 %
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail