Strengthening Of Street Light In Dark Places Different Location Of E / M-I Area, Noida., Noida-Uttar Pradesh

New Okhla Industrial Development Authority-NOIDA has published Strengthening Of Street Light In Dark Places Different Location Of E / M-I Area, Noida.. Submission Date for this Tender is 07-10-2021. Street Lighting Tenders in Noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29330607
Strengthening Of Street Light In Dark Places Different Location Of E / M-I Area, Noida.
Open Tender
Indian
Uttar Pradesh
Noida
07-10-2021

Tender Details

Strengthening Of Street Light In Dark Places Different Location Of E / M-I Area, Noida.

Key Value

Document Fees
INR 5310 /-
EMD
INR 212000.0 /-
Tender Value
INR 1.05 Crore /-

BOQ Items

Name of Work:-: Strengthening of Street Light in Dark Places different Location of E&M-I Area, Noida.
Sl. No. Item Description
1Supply & fixing of 10 mtr GI Octagonal Pole of approved make (top dia 100 mm, Bottom dia 200 mm and base plate 16mm thick) having 3 mm thikness with Double arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. PS No. 650
2Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including thecost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. PS No 645
3Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. PS No. 641
4Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top diaminium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. PS No 652
5Dis/re-eriction of 16 mtr High Mast including Cartage, Cost of Foundation bolt, Construction of plinth, Installation control panel, Earthing, Testing and commisioning etc completeas per direction of E/I (AOR)
6Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. PS No. 1424 AAA
7Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501 ( Grandley, Gloster, Kalinga, Havells, Nicco, Plaza, KEI Make)
8i) 16 sqmm x 4 core
9ii) 50 sqmm x 3.5 core
10iii) 70 sqmm x 3.5 core
11iv) 16 sqmm x 2 core
12v) 25 sqmm x 2 core (AOR)
13Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504
14i) 16 sqmm
15ii) 25 sqmm
16iii) 50 sqmm
17iv) 70 sqmm
18v) 120 sqmm
19Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) PS. No. 725 (A)
20Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. PS. No. 725 (B)
21Supply and laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.PS 506 (F) 120 sq. mm 3 core
22Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x16sqmm complete in all respects as per direction of E/I. (AOR)
23Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. PS 627
24Supply of PCC Pole 8.5 Mtrs as per UPERC-2019/I. No. 1 page 48
25Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 716
26S/F of 1100 Voltage grade aerial bunched cable, Power cable: Standard compacted circular aluminium conductor, XLPE insulator Messenger conductor, standard compacted circular all aluminium alloy bare conductor, 3 power core laid around messenger conductor 1cX16 sqmm lighting core aluminium conductor and XLPE insulated of size 3 core x120 sqmm + 1Cx95 sqmm + 1cx16sqmm. Complete in all recpects as per direction of E/I. (AOR)
27Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. (DSR-2018/I No. 12.34)
28Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. i) 90 mm dia (OD-90 mm & ID-76 mm nominal) DSR Electrical-18/I no. 14.16.2
29Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 120 sq. mm DSR Electrical-18 10.5.2
30Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. E/I E/I DSR Electrical-2018. 12.38
31Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. E/I DSR Electrical-2018. 11.3.4
32Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS. No. 807 e (ii) 25 A TPN
33Supply & fixing of Steel tubler pole 11 mtrs long designatted at 410-sp 56 in 1:3:6 cement concrete foundation including exavation back filling etc. complete in all respects. UPERC P No 30
34S/e testing & commissioning of 63 KVA Al wound outdoor type Distrivution Transformer as per ISS including fees as per direction of E/l (Paramax/Kanohar /LD/Technical Associates /Kirloskar/ Cromton/Aistom make) UPERC P No 51, I No. 3
35S/F of 11 KV TPMO Reico/Rama make 9 nos insulator of Jai shree/BHEL make complete in all respects as per direction of E/I UPERC-48
36S/f of 11 kv, 100 Amp, Drop fuse set channel type (3 nos) (AOR)
37S/E of straight MS channel 50x100 mm (9.2kg/m) 2.24 m long as per design with requird clamp made of MS flat 50x6 mm with all nuts and bolts etc. as per direction of E/I UPERC P-39
38S/F of 11 KV Pin insulator 70 KN and fitting B&S heavy duty with clamp of cross arm fixed on HT pole. BHEL/Jai shree/WS/RR/Make UPERC P-43
39S/F of 11 KV pin 12" long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc UPERC P-39 Annexure-16
40Supply of Clamp with nut and bolt as per UPERC 2019/I. No. 21 page 24
41S/F of Sintex Jucnction box No IIGSSJB2817 of size 240x130x110mm. Complete in all respects as per direction of E/I (AOR)
42S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve PS No. 1002 CAT A
43Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. SOR (Bulandshahar)
44Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)SOR (Bulandshahar) P-17, Item 281
45Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. AOR a) All works upto plinth level
46Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete (AOR)
47Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. a) Cold twisted bars AOR
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail