Addn/Altn To P-38 Bldg At Ins Utkrosh, Port Blair And Other Sanctioned Works Under Ge Minniebay, Port Blair Addn/Altn To P-38 Bldg At Ins Utkrosh, Port Blair And Other Sanctioned Works Under Ge Minniebay, Port Blair, GE, Minniebay, Junglighat (PO), Port Blair-Andaman And Nicobar Islands

Military Engineer Services-MES has published Addn/Altn To P-38 Bldg At Ins Utkrosh, Port Blair And Other Sanctioned Works Under Ge Minniebay, Port Blair Addn/Altn To P-38 Bldg At Ins Utkrosh, Port Blair And Other Sanctioned Works Under Ge Minniebay, Port Blair. Submission Date for this Tender is 14-10-2021. Building Work Tenders in GE, Minniebay, Junglighat (PO), Port Blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

29321263
Corrigendum : Addn/Altn To P-38 Bldg At Ins Utkrosh, Port Blair And Other Sanctioned Works Under Ge Minniebay, Port Blair Addn/Altn To P-38 Bldg At Ins Utkrosh, Port Blair And Other Sanctioned Works Under Ge Minniebay, Port Blair
Open Tender
Indian
Andaman And Nicobar Islands
GE, Minniebay, Junglighat (PO), Port Blair
14-10-2021

Tender Details

Addn/Altn To P-38 Bldg At Ins Utkrosh, Port Blair And Other Sanctioned Works Under Ge Minniebay, Port Blair Addn/Altn To P-38 Bldg At Ins Utkrosh, Port Blair And Other Sanctioned Works Under Ge Minniebay, Port Blair

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 58000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : ADDN / ALTN TO P-38 BLDG AT INS UTKROSH, PORT BLAIR AND OTHE SANCTIONED WORKS UNDER GE MINNIEBAY, PORT BLAIR
Sl. No. Item Description
1M&L for steel work in tubular trusses including special shaped washers etc complete confirming to IS 1161-1979 Grade St-240 complete all as specified and as directed
2M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide complete all as specified and as directed
3M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as manufacturers instructionand as directed.
4M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws
5M&L for in repairs aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 610 x 610mm suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab roof truss fixed with suitable size MS hook and fastening bolts etc including "E" board classic 4mm thick oceanic sheet of size n.exc. 610 x 610mm size fixed in ceiling with clips to aluminium snap grid incl preparation of new surface and applying two coats of oil bound distemper over a coat of primer all as specified and directed.
6Taking down carefully loose and broken concrete by chiseling/picking etc upto a depth of 20 to 40mm from wall, ceiling, columns, beams, roof and similar structural members cutting edges cleaning the dismantled portion with wire brushes etc. with removal of debris including necessary scaffolding etc. as required, complete all as specified and as directed.
7M & L for applying one coat of anti corrosive primer @ 0.25 Ltr /Sqm to exposed surfaces of old and new reinforcement to the full circumference and length of bars to form unbroken 40 Micron thick film as per manufacturer"s instructions complete all as specified and as directed.
8M &L for applying one coat epoxy bonding agent @ 1 ltr/2.6 Sqmor as per manufacturer"s instructions to old concrete surfaces of RCC floors, columns, beams and similar structural members for bonding with new concrete complete all as specified and directed.
9S & F in repairs Aluminium anodised (minimum anodisation is50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills,necessary joining cleats, glazing clips, rubber packing,anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed (Note:- Weight ofvarious Aluminium sections handles and locking arrangementsshall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted (NOTE :-Glass panels, prelaminated particle boards, glass & aluminium wire cloth as applicable will be measured and paid separately as supplied only).
10Supply only Aluminium anodised"XPM" 1.50mm x 3.00mm size for mosquito proofing 22 gauge thickcomplete all as specified and as directed. .
11S&F Framed work such as grills, gratings,etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde E-165complete all as specified and as directed.
12Supply only 5 mm thick Plain sheetglass of any sizes complete all as specified and as directed
13DismantlingStone slabs and tiles of anydescription or thickness in floors, apronslaid beded and pointed in any motar complete all as specified and as directed.
14M&L for Granite (of any type) work(table rubbed and polished)in steps, jambs, pillars, window- cills, cooking platformsand like in cementmortar (1:4) including pointingin white cement (1:2) usingmarble dust with admixture of pigment to matchwith shade of granite all as specified
15Dismantling floor, hearth or wall tiling including cement mortar bedding [but not backing] and removing serviceable tiles to the stores andremoving rubbish / debris of the premises complete all as specified and as directed.
16M & L for Non Skid Ceramic Tiles, Coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 mm to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
17M & L for Non Skid Ceramic Tiles, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 mm to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
18All as per item No 17 above, but on vertical surfaces incl 10mm thick CM 1:3 as in baking coat of dado / skirting complete all as specified and directed.
19M & L for Glazed Ceramic digital Tiles, Coloured, of size450X 300X 7 to 8mm thick as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10mm thick in CM 1:4 complete all as specified and as directed.
20M & L For coloured chequered cement concrete tiles 30 cm x 30cm x 25 mm thick, set andjointed neat cement slurry and pointed with coloured or grey cementmatch with pigment, over and including15mm thick screed bed or bedding layer in cm 1:6 etc. complete all as specified and directed.
21Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed..
22M&L for precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed.
23M&L forrendering 15mm thick plaster in CM (1:4) onbrick/block wall or concrete surfacesfinished even & fair all as specified and as directed.
24M&L forrendering 15mm thick plaster in CM (1:6) onbrick/block wall or concrete surfacesfinished even & smooth all as specified and as directed.
25M & L for preparing newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed
26All as per Item No 25 above but on ceiling complete all as specified and as directed
27Preparation of newly plasteredwall surfaces and applying two coats of acrylic emulsion based premium quality matt finish exterior antifungal paint over a coat of alkali resistant primer all asper manufacturer"s instructions complete all as specified and as directed
28Preparation of old plasteredwall surfaces and applying one coats of acrylic emulsion based premium quality matt finish exterior antifungal paint asper manufacturer"s instructions complete all as specified and as directed Note for item No 23 to 27 : The rates shall be included for scaffoldings as required at site
29M & L for preparation of old distempered and painted surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed..
30M & L for preparation of old painted wood and wood based surfaces of any description not other wise described not exceeding 10cm width or girth and applying one coat of yynthetic enamel paint complete all as specified and directed.
31M & L for preparation of old painted steel surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
32Supply and laying in repairs CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings onwalls/ceiling or laying in floors complete all as specified and directed.
33Supply and laying in repairs CPVC pipes 25 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings onwalls/ceiling or laying in floors complete all as specified and directed.
34S&F in repair Vitreous China Wash down water closet pan semi pedastel pattern(Anglo-Indian type, EWC) white in colour with and incl plastic water seat and cover white closed pattern with flat bottom and cover and MS chromium plated hinging device incl connection to outgoing pipe and flushing pipe complete all as specified and as directed.
35S & F in repairs Vitreous china ware wash hand basin, white, flat back of size 550 mm X 400 mm including 32mm brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand,etc complete all as specified and as directed.
36S&F in repairs10 litre capacity PVClow level valve less syphonic action type flushing cistern, white, with inlet,ball valve, float and handle including brackets, and 32mm PVC bend complete all as specified and as directed.
37S&F in repairs CP Waste coupling of size 32mm for Sink / WHB complete all as specified and directed.
38S&F in repair CP towel rail 20 mm dia, 60 cm long fixed with CP screws and wood cleats / rowel plug inwall, complete all as specified and as directed.
39S & F in repairs 600 mm X 450 mm Bevelled Edge Mirror of selected quality glass, 5 mm thick, mounted on 6 mm thick AC building board or commercial plywood complete all as specified and as directed.
40S & F in repair Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type heavy duty, 15 mm dia, with capstan head, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
41S & Fin repairs to Bib Taps, cast copper alloy heavy duty, 15 mm dia, Chromium Plated, Fancy Type screwed down for iron pipe and fixed etc complete all as specified and as directed.
42S & F in repairs 15 mm dia bore cast copper alloy chromium plated angle cock/stop cock with long shank and cup screwed down high pressure with capstan head, screwed both ends for iron pipes or for union and fixed, complete all as specified and as directed.
43S & Fin repairs toTwo way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type screwed down for iron pipe and fixed etc complete all as specified and directed.
44S&F in repairchromium plated health faucet with 1000mmPVC pipe for 15 mm bore with fittings complete all as specified and directed.
45S&F in repairsbrass chromium plated shower rose with 150mm longCP shower arm 125 mm size revolving type suitable for 15 mm bore pipes complete all as specified and as directed.
46S & F in repairs 32/40mm dia PVC flexible Waste Pipe, 750 mm long fixed to Wash Hand Basin or Sink complete all as specified and directed..
47S&F in Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long of approved quality complete all as specified and as directed.
48S&F in repair 100 mm dia CP grating with/without hole incl joints with solvent cement complete all as specified and directed.
49S&F in repairs PVC(SWR) floor trap of any dia, plain with grating including jointing with solvent cement fixed in cement concrete all as specified and directed
50S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls/floor including necessary fittings and fixture complete.
51Taking down old u/s water storage tank of capacity 1000 Ltrs incluing all connections includig fittngs complete all as specified and as directed
52S&F 1000 litres rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including complete all as specified and directed.
53S&F inrepairs110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls all complete all as specified and directed.
54M&L for making arrangements for scaffolding in shafts/spot/location of weed growth,spraying anti weed solution of Herabicide Glyphosate 41% or equivalent on plant /weedleaves withoutcutting/disturbingthe plants on sunny weather and allow the plant / weedto dry for a period of 30 daysand removing the weed incuding its root ,making good with CM 1:3 or with PCC 1:2:4(12.5mm graded aggregates) including02 coats of acrylic paint complete all as specified and directed.
55M&L for demolition of Concrete in ground floors andpavings n exc 15 cm thickness (below or above ground level ) complete all as specified and directed.
56M&L for 75mm thick Cement concrete in C1 type (1:3:6) using 20mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement complete all as specified and directed.
57Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in hard/dense Soil complete all as specified and directed.
58M&L Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
59M&L for Reinforced cement concrete M-30 (design mix) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified.
60M&L for form work to sides of rough finished concrete foundations, foootings, bases of columns, raft and raft beams, sides and soffits if any of foundation and plinth beams and similar work vertical or to batter compelte all as specified and as directed
61M&L for Reinforced cement concrete M-30 (design mix) in columns,pillars, piers, posts and struts etc complete all as specified.
62M&L for form work to sides of Pillars, posts, struts, piers,columns and sanctions complete all as specified and directed.
63M&L for Reinforced cement concrete M-30 (design mix) in Beams, cantilevers, bressumers, lintels over 1.5m span, complete all as specified.
64M&L for form work to sides and soffits of rough finished floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs,etc alos splays between floors, and beams,etc compelte all as specified and as directed
65M&L for Reinforced cement concrete M-30 (design mix) in Slab . supported on walls, beams and columns in floors, roofs, landings, balconies canopies, deck slabs and in shelves and the like complete all as specified.
66M&L forform work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) complete all as specified and directed.
67M&L for form work to edges of concrete flats, treads, breaks in floors, window cills,concrete railings,opeinings in concrete walls, floors and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and smimilar work all exceeeding 10cm wide and n.exc 20cm wide with rough finished surfaces complete all as specified and directed..
68M&L for Reinforced cement concrete M-30 (design mix) in Chajjas complete all as specified and directed.
69M&L for form work to chullah hoods, chajjas,troughs and similar items including edges,etc compelte all as specified and as directed
70M&L for TMT bars 10mm dia and over as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing clips complete all as specified and directed.
71M&L for TMT bars 6 mm to 8 mmdia in stirrups, spacers, and binders in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire complete all as specified and directed.
72M&L for Moorum /Red Bajrifilling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
73M&Lfortreating the bottom & sides of excavation @ 5 lit of emulsion per sqm of surface area complete all as specified and directed.
74M&L for ATT on top of earth filling @ 5 lits/sqm complete all as specified and directed.
75M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
76Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified and directed.
77Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
78M&L for rendering 10mm thick on fair faces of brick/concrete surface in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed.
79M&L for externalrendering 5mm thick in CM 1:4 with water proofing compound (water proofing compound shall be used as per manufacturers instructions) over a coat of 10mm thick in CM 1:6 over brick or concrete surfaces finished even and fair complete all as specified and directed. Note : WPC shall be measured and paid separately
80M&L for rendering to ceiling in 5mm thick on fair faces concrete surface in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed.
81Supply only water proofing compoundconforming to IS-2645 1975 complete all as specified and directed.
82M&L forPCC 1:5:10 type E2 (40mm graded aggregate) as for floor surface complete all as specified
83M&L Non skid ceramic tiles each tile area (sqr/rectangle) exc 0.06 Sqm but not exceeding 0.11 Sqm tile thickness 7 to 8 mm, in floors etc set and joined in neat cement slurry and pointed in white or coloured cement to match incl Screed bed or bedding layer with CM 1:4 15mm thickfor laying floor finishes all as specified .
84M&L Glazed ceramic tiles coloured 300x 200x5 to 6mm thick on vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.incl 10mm thick in CM 1:3as backing coat for fixingdadotiles all as specified.
85S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
86S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
87M& L for 2 nd class hard woodPlain, solid, straight chowkats and frames, wrought, framed rebatedon the solid, rounded or chamfered,put together with glue pinned at joints complete all as specified and directed.
88S&F bands, straps , supports or stays for rain water, ventilating pipes including bolts, clamps, hold fasts etc and similar small articles to Fe-410-0 or Fe-310-0 complete all as specified and directed.
89S& F 35 mm thick plain 2nd classhard woodframed panelled shutters (any number of panels) with panels of timberflat on both sides (feather edged) or of veneered particleboardmedium density, wood particle board with commercial face veneerssupplied and fitted to chowkats complete all as specified and directed.
90M& L for cement concrete type C-1, 1:3:6 using 20mm graded stone aggregate as in filling under hold fastas directed including necessary form work, complete all as specified & directed.
91M& L for treating with tar or coal tar black paint on back of chowkats, area tarred exec 0.1 Sqm but not exceeding 0.5 Sqm each treated with tar or coal for black paint all as specified.
92M& L for treating small articles such as stop, covers, gully grating, hold fasts, and of posts , back of chowkats, etc area not exc 0.1 Sqm each treated with tar or coal tar black paint complete all as specified
93S& F 35mm thick second class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc ( without sash bars), edges of framing plain, chamfered or rounded , fitted with cut and mitered beads for securing glass, etc size of members of shutters as specified & directed in SSR Part-I , section 8, clause 8.20 (a) complete all as specified and directed. Note :- Glazing or wire mesh will be measured and paid separately )
94S&F100 mmButthinges, mild steel cold rolled but cast brass, bright polished and fixed type B -11complete all as specified and directed.
95S& F4 mm thick sheet figured glassand glazing with rubber packing around the glass, in squaresexceeding 0.50 sqm in each pane complete all as specified and as directed.
96S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
97S&F 100mm Butt hinges extruded brass, with mild steel hinge pin, bright polished and fixed, type B-21 complete all as specified and directed.
98S& F Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips to sheet cast or extruded sections and fixing bolt or cast aluminium alloy complete all as specified and directed.
99S&F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
100S&F 300mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
101S&F150mm long extruded aluminium alloy anodised handles fabricated type complete all as specified and directed.
102S&F100mm long extruded aluminium alloy anodised handles fabricated type complete all as specified and directed.
103S&F140mm aluminium alloy anodised floor door stoper and tongue with hard drawn steel spring complete all as specified and directed.
104M&L for preparing new or previsouly untreatedsurfaces of anydescription and applying two coats of syntetic enamalpaint over one coat of primer in 10cm girth or width complete all as specified and directed.
105M&L 10mm thick cement plaster in CM (1:3) on top of roof slab all as specified complete all as specified and directed.
106M & L for roof treatmentwith following specification completely, complete all as specified and as directed (i)Applying evenly a tack coat of bitumen primer @ 0.3 kg/ sqm. (ii) Laying a coat of hot bitumen 85x25 @ 1.2kg per sqm. (iii)Laying APP modified membrane weighting not less than 3 to 4 kg/sqm in 100 mm over laps both longitudinally and transversally and overlaps to be sealed by torch, membrane shall be taken upto the thickness of slab/front fascia.
107M&L for Cement concrete 1:3:6 type C-2 (using 40mm grade stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 110mm bore PVC (SWR)drain pipes all as specified
108S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
109S&F PVC (SWR) bends of radius 110mm bore complete all as specified and directed.
110S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
111S&F 20 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe complete all as specified and directed.
112S&F 15 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipecomplete all as specified and directed.
113S&F Vitreous china squatting pan orissa pattern of size 580x440mm white with integral foot rest and including 10 Ltr capacity low level flushing systern with flexible pipe and necessary necessary Pvc connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
114S&FMirror of selected Quality glass 600 x 450mm, bevelled edge mounted on 6mm thick plywood commercial fixed to wooden plugs with CP brass screws & cup washers,Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed
115S&F PTMT gratings 125mm dia, complete all as specified and as directed
116S&F Vitreous China wash hand basinof size 550 x 400mm white flat back including chromium plated, pillat tap, waste coupling, including brackets, PVC waste pipe, including cutting for and pinning in ends of brackets or errecting stand, complete all as specified and as directed
117S & F 15mmpillar tap cast copper alloy, with capstan heads chromium plated screwed down high pressurewith or without lettered "Hot" or "Cold" withlong screwed shanks and fly-nuts screwed for iron pipe complete all as specified and as directed
118S&F15mm stop valves cost copper alloy, screwed down, high pressure, with fancy type, chromium plated, screw both ends complete all as specified and as directed
119S&F 15mm PVC connection 600mm longwith CP brass nutscomplete all as specified and as directed
120S&F 15mm Bib tap cast copper alloy chromium platedfancy type screwed down screwed for iron pipe or brass ferule etc complete all as specified and as directed
121S&F 20mm CP towel rail, 60 cm long fixed with CP screws and wood cleats / rowel plug inwall, complete all as specified and as directed.
122S&F 125mm CP shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
123S&F 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
124S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed.
125Surface dressing not exceeding 15 cm deep and geting out in hard/dense soil complete all as specified and as directed.
126M&L PCC1:4:8 D2 (40mm graded aggregate) 100mm thick for paving,sub basepath etc complete all as specified and as directed.
127M&L PCC1:2:4 B1 (20mm graded aggregate) 100mm thick for paving, etc complete all as specified and as directed.
128M& L for cutting into existing manholes size110 mm diafor connecting new drains / sewage linemaking good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4section) in cement concrete 1:2:4 type B-l smooth finished, and reformingbenching as required complete all as specified and as directed.
129Excavation post holes or similar holes, each not exceeding 0.5 Cum, getting out in hard/ dense soil, Returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed. .
130M &L for Cement concrete (1:2:4 type B-2 40 mm graded aqggregate filledin post holes foundations filling and mass concrete complete all as specified
131M&L for Plates (Plain or Chequered) channels, square or notched (Ordinary and counter sunk) forming holes, without any attachment of Fe 290 (Gde E-165) completely all as specified and as directed
132S & F aluminium flat iron work in, wind ties screwedas directed, including all necessary drilling, bolting or riveting etcand similar work
133M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
134Taking down carefully old copper point wiringcompletefor one light/fan/socket out let point and removing material from site incl fittings /fixtures and making good the disturbed surfaces all as directed.
135M & L point wiring with 1.5 Sq.mm (nominal area) pvc unsheathed multi standard copper conductor pvc insulated 1100 volt FRLS grade multistranded cable drawn through and including PVC casing capping/conduitISI marked minimum 20mm size and its accessories complete along with 1.5 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface,in walls/ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches, switch socket combinations fan regulators etc., as required with 3 mm thick plastic laminated sheet top cover all as directed and specified for the following:-
136One light /fan point controlled by one switch 5 Amps
137One 5 Amps plug point independent board controlled by one switch
138One three pin switch socket 5 Amps plug point on same board
139All as per item No 135 above but with 2.5 Sqmm single coremulti standard copper conductor for one three pin socket 5 Amps on independent board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly complete all as specified and as directed.
140All as per item No 135above but with 4 Sqmm single coremulti standard copper conductor for one three pin socket 15 Amps on independent board/ metal clad socket for AC point including continuous earth wire PVC insulated 4Sqmm copper solid conductor to common earth dolly complete all as specified and as directed.
141S&Fin replacement of socket outlet 2/3 pin 5 Amps 240 volts flush type complete all as directed.
142S&Fin replacement of socket outlet 3 pin 5/15 Amps 240 volts flush type complete all as directed.
143S&Fin replacement of switches6 Amps 240 volts flush type complete all as directed.
144S&Fin replacement of switches15 Amps 240 volts flush type complete all as directed.
145S&F in replacement of ceiling rose surface type Bakelite 65 x 50 mm with three terminals with ISI mark. complete all as specified and as directed..
146M & Lfor sub main wiringof 2.5 Sqmm PVC insulated unsheathed cable 1100 volts FRLS grade with multi strand copper conductor and 2.5 Sqmm as earth wire and drawn into and including PVC casing capping/conduitISI marked minimum 20mm size and its accessories along with continuous earthing wirebut in green colour complete on surface/concealed and connected to common earth dolly completely all as specified and as directed Note : 2 run of 2.5 Sqmm, 1 rum of 2.5 Sqmm and PVC conduit shall be measured and paid as one unit
147S&F in replacement sheet enclosure with category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCB TPN 415 Volts 4 way, all as specified and directed. Note : Sheet metal enclosure for MCB distribution board shall be fixed in the wall such that front cover shall be seen flush with the wall surface
148S&F in replacement of MCB triple pole and neutral 63 Amps working on 415 volts 50 Hz AC supply,10 KA C seriescomplete all as directed.
149S&F in replacement of MCB single pole6 to 40 Amps working on 240 volts 50 Hz AC supply,10 KA C seriescomplete all as directed.
150S&F in replacement of metal clad socket single pole and neutral sheet metal enclosure with and earth plug and socket complete with one single MCB 20 amp 240 Volts all as specified and directed.
151S&F in replacement of sheet metal enclosure (DBs) for fixing MCBs single pole and neutral 8 way with 200 Amps rated bus bar single door complete all as specified and as directed.
152S&F in replacement of MCB SPN 40Amps 10KA 220V 50Hz complete all as directed.
153S & F in replacement of LED tube light fitting, 20 w, 230v .Surface and wall mounted LED batten, elegant dia cast aluminium batten for designer homes bright LED source with uniform light out put , 2400 lm , surge protection of 2 KV with wide voltage protection 160-360 V inprovided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. & connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified directed. Make : Cat Pat No BN308C LED 20S -6500 L 60 PSU WH of Phillips or equivilant makes metioned in PS
154Taking down security light including fittings complete all as specified and as directed
155S&F security light fitting LED type,20 Watts 240 Volts luminous shall be more than2000 lumen, efficiency not less than 100 lm/Watt ,and accessories complete mounted on 25 mm dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall, connection completecomplete all as specified and as directed. Make Cat part no BRP022 LED 20 CW MR S1 PSU GR of phiplips or equivilant makes mentied in PS
156Soppy & laying and testing cable XLPE insulated, screened, PVC bedded, aluminums conductor, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50Sqmm 3.5core, laid in duct / fixed on wall/trenches complete all as specified and as directed..
157Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil complete all as specified and as directed.
158Returning filling in, including spreading, leveling, watering and well ramming soils in layers not exceeding 25 cm thick all as specified and directed.
159Removing the excavated surplus soilnot exceeding 50 m and depositing where directed at level not exceeding 1.5 m above the starting level complete all as specified and as directed.
160Supply, laying of DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm and inner dia 76 mm polyethylene including couplers, bends, cap etc.,with smooth internal and profiled external surface for non pressure under ground cable complete all as specified.
161S & F in replacement of Exhaust fan 5 star rating , 450 mm Sweep 240 volt , Opal . White / brown including making hole for fixing andmaking good to disturbed surface to match with existing surface and necessary connections complete all as specified and as directed.
162S & F ceiling fan HS decor 5 star rating, 1200 mm Sweep 240 volt , Opal . White / brown including rod minimum length 1.5 m and bush , nut bolts , capacitors including drilling on roof and fixed 1 to 1.5 feet rod and connecting bolts etc all specified complete all as specified and as directed.
163Supply and fixing Geyser ( water storage type) 25 Ltr Capacity energy saving 5 star rating and all features as per manufacturer"s specification 240V electric supplied and installed complete including 2 years maintenance spare parts complete all as specified and as directed.
164M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note:(i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
165S&F DB SPN 8 waywith category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs,all as specified and directed.
166S&F MCB DP 32 Amps working on 415 volts 50 Hz AC supply,10 KA C seriescomplete all as specified and as directed.
167S&F MCB single pole6 to 40 Amps working on 240 volts 50 Hz AC supply,10 KA C series complete all as specified and as directed..
168S & FExhaust 300 mm Sweep 240 volt , Opal . White / brown including making hole for fixing andmaking good to disturbed surface to match with existing surface and necessary connections complete all as specified and as directed.
169S&F step type fan speed control regulator of 220V single phase complete all as specified and as directed..
170Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed.
171Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and as directed.
172Supply, laying of DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm and inner dia 76 mm polethylene including couplers, bends, cap etc.,with smooth internal and profiled external surface for non pressure under ground cable complete all as secified.
173Design, Supply, installing testing and commissioning factory fabricated out door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of redoxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement,including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge.including Supply and fixing the following :-
174(a) MCCB TPN 160 Amps 50 Hz, 415 V with rupturing capacity 36 KA-1 No (Incoming) (b) MCCB TPN 125 Amps 50 Hz, 415 V with rupturing capacity 35 KA-02 Nos (Outgoing) (c) MCCB TPN 100 Amps 50 Hz, 415 V with rupturing capacity 25 KA - 01 Nos (Outgoing) (d) Voltmeter 0-500V with selector switch (Digital type)-01 No (e) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No (f) Indicating lamps (RYB) -01 Set (g) PCC Foundation (Civil works) for grouting of panel
175Supplying, laying GI water tubing, medium grade, of 50mm bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing etc complete all as specified and as directed
176Supplying, laying GI water tubing, medium grade, of 25mm bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing etc complete all as specified and as directed
177S&F Gun Metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed of 50mm bore complete all as directed.
178Supply and fix Gun Metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed of 25mm bore complete all as directed.
179S&F Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed of 25mm bore complete all as directed.
180M&L for cutting existing GI/DI pipe line of 50/80mm bore and making connection of 25 mm bore GI pipe complete all as directed at site.
Disclaimer :