Repair / Maint Of Dg Sets And Amf Panels And Other Connected Works At Af Stn Mamaura. Repair / Maint Of Dg Sets And Amf Panels And Other Connected Works At Af Stn Mamaura., AF STN MEMAURA-Uttar Pradesh

Military Engineer Services-MES has published Repair / Maint Of Dg Sets And Amf Panels And Other Connected Works At Af Stn Mamaura. Repair / Maint Of Dg Sets And Amf Panels And Other Connected Works At Af Stn Mamaura.. Submission Date for this Tender is 20-10-2021. Diesel Generators Tenders in AF STN MEMAURA Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29319375
Corrigendum : Repair / Maint Of Dg Sets And Amf Panels And Other Connected Works At Af Stn Mamaura. Repair / Maint Of Dg Sets And Amf Panels And Other Connected Works At Af Stn Mamaura.
Open Tender
Indian
Uttar Pradesh
AF STN MEMAURA
20-10-2021

Tender Details

Repair / Maint Of Dg Sets And Amf Panels And Other Connected Works At Af Stn Mamaura. Repair / Maint Of Dg Sets And Amf Panels And Other Connected Works At Af Stn Mamaura.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 11000.0 /-
Tender Value
INR 5.50 Lakhs /-

BOQ Items

Name of Work: Repair/maint of DG Sets and AMF Panels and other connected works at AF Stn Memaura.
Sl. No. Item Description
1Servicing of DG set capacity 125 KVA make cummins and taking out the defective/unserviceable parts and re-assembling the same after repair/ replacements and testing complete all as specified and directed.(Note : U/S spare parts shall be measured and paid separately as supply only here in after).
2Diesel filter
3Oil filter
4Oil pressure gauge
5Hose pipe set with clamps & clips complete.
6Ampere meter
7Volt meter.
8Air filter
9Fan belt
10Repair & over hauling DG set capacity 125 KVA make - cummins of FIP including replacement of defective parts as required including calibration in authorised factory/dealers & testing complete all as directed.
11-Ditto- all as per item No 1 above but DG set of capacity 20 KVA to 50 KVAMake - Kirlosker/Eicher.
12Diesel filter
13Oil filter
14Oil pressure gauge
15Hose pipe set with clamps & clips complete.
16Ampere meter
17Volt meter.
18Air filter
19Fan belt
20Repair & over hauling DG set capacity 20 KVA to 50 KVAMake - Kirlosker/Eicher.of FIP including replacement of defective parts as required including calibration in authorised factory/dealers & testing complete all as directed.
21Dismantling of rediator assembly complete from DG set of capacity 125 KVA carefully and cleaning with acid/descalling solution in copper tubes & fins including repairing of bottom plate & rectify the leakage by soldering welding and re-fixing the same and testing complete all as specified and directed.
22Dismantling of rediator assembly complete from DG set of capacity 20 KVA to 50 KVA carefully and cleaning with acid/descalling solution in copper tubes & fins including repairing of bottom plate & rectify the leakage by soldering welding and re-fixing the same and testing complete all as specified and directed.
23Disconnecting, and taking out carefully old unserviceable self starter suitable for 125 KVA DG set. of any make and capacity,supply, fixing and testing of Self starter ofexisting make suitable for125 KVADG set complete all as specified and directed.
24Disconnecting, and taking out carefully old unserviceable self starter suitable for 20 KVA to 50 KVA DG set. of any make and capacity,supply, fixing and testing of Self starter ofexisting make suitable for20 KVA to 50 KVA DG set complete all as specified and directed.
25Supply and filling lubrication oil SAE-40 ( 20 W- 40 grade) ofMake SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL/ CASTROL) as approved by Engr-in-Charge.
26Disconnecting and taking down old unserviceable 125 KVA self starter, 12Volt/24 Volt DC and dismantling complete for repair, servicing, cleaning, varnishing, oiling, reassembling & testing including replacement of the Following parts :- (a) Armature – 01 No (b) Solenoid switch – 01 No. (c) Field coils – 01 No. (d) Commutator – 01 No. (e) Carbon brush – 02 Nos (f)Bendex assembly – 01 No
27Disconnecting and taking down old unserviceable 20 KVA to 50 KVA self starter, 12Volt/24 Volt DC and dismantling complete for repair, servicing, cleaning, varnishing, oiling, reassembling & testing including replacement of the Following parts :- (a) Armature – 01 No (b) Solenoid switch – 01 No. (c) Field coils – 01 No. (d) Commutator – 01 No. (e) Carbon brush – 02 Nos (f)Bendex assembly – 01 No
28Taking out carefully unserviceable fuel injector pump assembly of 125 KVA DG set of 1500 RPM Make:- CUMMINS/KIRLOSKAR/EICHER/ASHOKLEYLAND/ GREAVES COTTN/CROMTON, cleaning/ oiling/servicing fuel injector pump assembly , recalibration of Fuel Injector Pump after replacing unserviceable nozzles/repair kit/Element/ Delevery valve with washer etc. which shall be measured seperately including minor spares which are not mentioned and required for complete functioning , re-assembling and fixing the same in positionand testing the fuel injector pump assembly all as specified and directed by Engineer-in-Charge.
29Fuel injector with nozzle
30Repair kit
31Delivery valve
32FIP element
33Taking out carefully unserviceable fuel injector pump assembly of 20 KVA to 50 KVA DG set of 1500 RPM Make:- UMMINS/KIRLOSKAR/EICHER/ ASHOKLEYLAND/ GREAVES COTTN/ CROMTON, cleaning/ oiling/servicing fuel injector pump assembly , recalibration of Fuel Injector Pump after replacing unserviceable nozzles/repair kit/Element/ Delevery valve with washer etc. which shall be measured seperately including minor spares which are not mentioned and required for complete functioning , re-assembling and fixing the same in positionand testing the fuel injector pump assembly all as specified and directed by Engineer-in-Charge.
34Fuel injector with nozzle
35Repair kit
36Delivery valve
37FIP element
38Preparation of existing surface of D.G. Set at various locations capacity 125 KVA by scraping out the old existing peeled off paint layer, filling the cavities with suitable filler, making the surface smooth and applying two coats of synthetic enameled paint by spray machine including writing necessary details of D.G. Set i.e. SM No. & MES No. in the pattern and style with using synthetic enameled white paint complete as directed by Engineer-in-Charge.
39Preparation of existing surface of D.G. Set at various locations capacity above 20 KVA to 50 KVA by scraping out the old exiting peeled out paint layer filling the cavities with suitable filler, making the surface smooth and applying two coat of synthetic enameled paint by spray machine including writing necessary details of D.G. Set i.e. SM No. & MES No. in the pattern and style by using synthetic enamelled white paint complete as directed by Engineer-in-Charge.
40Replacement of battery 180 AH ,12 voltincluding battery terminals complete all as specified and directed by Engineer-in-Charge.
41Replacement of battery 150 AH ,12 voltincluding battery terminals complete all as specified and directed by Engineer-in-Charge.
42Disconnecting, and taking out carefully old unserviceable AVRof 125 KVA DG Set Make : Kirloskar/ Greaves Cotton Supply and fixing and testing new AVRcomplete all as specified and directed.
43Disconnecting, and taking out carefully old unserviceableAVRof 20 KVA to 50 KVA capacity of DG set, Make : CUMMINS/KIRLOSKAR/EICHER /ASHOKLEYLAND/ GREAVESCOTTON/CROMTON, Supplying and fixing and testing new AVRcomplete all as specified and directed.
44Supply, installation, testing and commissioning for microprocessor based factory fabricated AMF Control panel indoor type system suitable for 50 to 125 KVA DG Set with and including internal wiring, free standing, floor mounted type, vertical type,front operated, dust & vermin proof & sound proof canopy fabricated out of14 SWG MS CRCA sheet duly undergoing with pretreatment covering degreesing water rinsing,derusting/phosphating.After pre treating, sheet metal shall be sprayed with highcorrosion resistance primer and finally epoxy polyester powdercoating of flint grey shade.The panel consisting of following:- (i)Aluminium bus bars of suitable rating- 04 Nos with SMC/DMC support (ii)AC Voltmeter 0-500 volt, 96 mm x 96 mm digital type with inbuilt selector switch-01 No. (iii)AC Amp meter 0-300 Amp, 96 mm x 96 mm digital type with inbuilt switch - 01 No. (iv)Frequency meter 40-99.99 Hz, size 96 mm x 96 mm digital type - 01 No. (v)Single lamp indicator (Self running type) - set of three (LED type) - 01 Set. (vi)Single lamp indicator (Self running type) - 01 Set (LED type). (vii)Battery charging indicator lamp - 01 No. (viii)Auto/Manual/Test Switch - 01 No. (ix) Battery charging Amp meter and voltmeter digital - 01 No. (x) MCCB, 04 Pole with suitable capacity ICU 36 for 415 Volts, overload and short circuit protection 03 Phase AC supply, Qty - 02 Nos..
45(xi)Under / over voltage relay, suitable for 3 phase 415 Volts AC-3 supply --------02 Nos. (xii) Electronic timer type ET, suitable for 12 Volts, DC supply as per recommendation of DG manufacturer - DC supply for 0-10 second - 01 No. (xiii)Electronic timer type, suitable for 240 Volts 50 Hz AC supply for 0-60 second ON relay - 02 Nos. (xiv)Electronic timer type, suitable for 240 Volts 50 Hz AC supply for 0-60 second OFF relay - 01 No. (xv)Engine starting relay with sequence timer & master timer suitable for 12 Volts DC supply as per recommendation of DG manufacturer - 01 No. (xvi)Battery charging transformer 12 Volts DC as per recommendation of DG manufacturer - 01 No. (xvii)By pass arrangment with rotary type by pass change over switch of capacity 315 Amps AC on load to isolate the AMF panel at the time of low voltage. Make : Schinder/Siemens/Legrand. (xviii)Three pole power contactor with standard coil voltage of 415 Volts 50 Hz and axiliary contract of 02 Nos having AC three phase rating of 315 Amps MNX series type of L&T or eqvt of Siemens/Schinder/Legrand/BCH - 02 Nos. (xix)Booster relay of 12 Volts capacity - 01 No. Make: M/s Sudhir Power, M/s Kirloskar Green, M/s Sparsh Engineering
46Supply and fix in replacement LED driver sutable for 35 wattto 90 watt Led fittings includingconnection as directed by Eng-in-charge CROMPTON / PHILLIPS/C&S / HAVELLS.
47Supply and fix in replacement factory made IP 65, dust and power jet proofstreet light Junction box of size 225mmx225mmx112mm made of high quality polycarbonate ( shock proof, rust free, corrosion free, acid and chemical resistant, fire ratardant, having high impact (IK 08) totally insulated (class II) made of helogen and silica free recyclable material UV resistant, having high grade gasket made of polyurethane with connector and locking arrangement and 2 numbers of M 40 size cable glands and one M32 size gland suitable upto 25 sqmm cable etc including one MCB SP6 amps rating 10 KA with suitable mounting clamps for steel tublar poles including taking down old junction boxes complete all specified and directed. Make: Hensel/ Sentex/ ABS
48Repair of AMF panel connected to 125 KVA DG Sets including replacing/ servicing the following defective components/ parts all as directed by Engr-in- Charge:-(a) Servicing of power contactor 12 way -02(b) Servicing of auxillary contacts(c) S&F Terminal connectors 12 way -02 (d) S&F Cyclic timers 0-120 sec - 04(e) S&F auto / manual selector switch -01 (f) S&F Push buttons - 08 (g) S&F Indicator lamps - 13(h) S&F Voltmeter 0-500V -02(j) S&F Ammeter 0 -600 A -02 (k) S&F Frequency meter 45-55 Hz-01 (l) S&F AMF panel lock -13(m) S&Frelay -10(n) M&L for AMF panel complete control wiring with 1.5 to 2.5 sqmm copper conductor with identification tags including testing and commissioning.