Replacement Of 4 No Cooling Towers Installed At Advanced Eye Care Centre Pgimer Chandigarh Replacement Of 4 No Cooling Towers Installed At Advanced Eye Care Centre Pgimer Chandigarh, Advance Eye Centre-Chandigarh

Postgraduate Institute Of Medical College has published Replacement Of 4 No Cooling Towers Installed At Advanced Eye Care Centre Pgimer Chandigarh Replacement Of 4 No Cooling Towers Installed At Advanced Eye Care Centre Pgimer Chandigarh. Submission Date for this Tender is 04-10-2021. Cooling Tower Tenders in Advance Eye Centre Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

29319152
Replacement Of 4 No Cooling Towers Installed At Advanced Eye Care Centre Pgimer Chandigarh Replacement Of 4 No Cooling Towers Installed At Advanced Eye Care Centre Pgimer Chandigarh
Open Tender
Indian
Chandigarh
Advance Eye Centre
04-10-2021

Tender Details

Replacement Of 4 No Cooling Towers Installed At Advanced Eye Care Centre Pgimer Chandigarh Replacement Of 4 No Cooling Towers Installed At Advanced Eye Care Centre Pgimer Chandigarh

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 24.99 Lakhs /-

BOQ Items

Name of Work: Replacement of 4 nos. cooling towers installed at Advanced Eye Care centre, PGI, Chandigarh.
Sl. No. Item Description
1Supplying, installing, testing and commissioning of counter flow induced draft FRP cooling tower with drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan-direct drivenwith TEAO induction motor(IE-3), suction screen make up quick fill arrangement, overflow and drain connections with necessary valves and float valves suitable aluminum inspection ladder, access arrangement for cooling tower interior cement concrete foundation, steel / masonary supporting structure, anti vibration mountings etc. complete as per specification and as reqd. The maximum allowable sound power at a distance of 1 M from the fan shall be 70-75 DB(A). The cooling tower model shall be selected to suit site conditions, duty conditions and indicated refrigeration capacity of the chiller it is serving to. The cooling tower shall be supplied with ph monitoring kit.
2Water flow Rate 700 USGPM, HWT 97.5 F, CWT 90.0 F and WBT 83.0 F
3CONDENSER WATER PIPE
4Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS "C" class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. "C" class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
5250 mm Dia
6200 mm Dia
7150 mm Dia
8100 mm Dia
980 mm Dia
1050 mm Dia
11Labour charges for modification of Existing pipes as per requirement of site
12250 mm Dia
13200 mm Dia
14150 mm Dia
15100 mm Dia
1680 mm Dia
1750 mm Dia
18Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications
19BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
20150 mm Dia
2180mm Dia
22Civil Part
23Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
241:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size)
25Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.
26Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge.
27All kinds of soil
28Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
291:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
30Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
31Thermo-Mechanically Treated bars of grade Fe-500D or more.
32Centering and shuttering including strutting, propping etc. and removal of form for :
33Foundations, footings, bases of columns, etc. for mass concrete
34Lintels, beams, plinth beams girders, bressumers and cantilevers
35Columns, Pillars, Piers, Abutments, Posts and Struts
36Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
3725 mm dia nominal bore
3850 mm dia nominal bore
39Labour charges for Modification of existing G.I. pipe as per site requirement
4025 mm dia nominal bore
4150 mm dia nominal bore
42SITC of brass ball valve.
4325 mm
44Applying priming coat:
45With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/steel works
46Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
47Two or more coats on new work
48SITC of thermoplastic Circuit breaker boxes IP 65 (with metric knockouts for cable entry) 1 Row 4 modules
49Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5040/32 Amp
51Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
52100 mm width X 50 mm depth X 1.6 mm thickness
53Supplying, installation, testing and commissioning of complete cable work using 1.1kV grade XLPE insulated PVC sheathed steel tape/wire armoured underground stranded cables as per IS-7098 (Part-1) of following sizes of electric supply from main panels in AC plant room, to various loads including interconnections (terminations) from starters to motors on suitable cable trays / existing UPVC pipe with supports as required including connections on both sides as per specifications and as required
543 core 6 sqm mm aluminium armoured cable
55Dismantling and removing of all existing cooling tower scrap from the site
56Buy back cost of all cooling tower including motors, butterfly valve, etc ( Except condenser pipe and G.I pipe 50 and 25mm)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail