Public Works Department-PWD has published Improvement Of Rub Surrounding Area And Construction Of New Additional Sump At Rub Badarpur Under Sub Division Ser-24 In Division Ser-2, New Delhi And Enhancement Of Substation, Etc. Improvement Of Rub Surrounding Area And Construction Of New Additional S. Submission Date for this Tender is 01-10-2021. Substation Tenders in NEW DELHI Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil |
2 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
3 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of50 m : Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm |
4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
6 | "1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). |
7 | 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). |
8 | Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying andcuring, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. M-10 grade plain cement concrete (cement contentconsidered @ 220 kg/cum) |
9 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars |
10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
11 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum Excess/less cement used as per design mix is payable/recoverable separately) |
12 | All works upto plinth level |
13 | All works above plinth level upto floor V level |
14 | Centering and shuttering including strutting, propping etc. and removal of form for : |
15 | Foundations, footings, bases of columns, etc. for mass concrete |
16 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc |
17 | Suspended floors, roofs, landings, balconies and access platform |
18 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
20 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
22 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 300 mm weighing not less than 200 gms |
23 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
24 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
25 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece |
26 | Supplying and fixing rolling shutters of approved make, made ofequired size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
27 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
28 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
29 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
30 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
31 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipe 110 mm diameter |
32 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend |
33 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
34 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
35 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
36 | Neat cement punning |
37 | Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer"specification. Two or more coats on new work |
38 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
39 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
40 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
41 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
42 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
43 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal ofnserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
44 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
45 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
46 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
47 | Taking out existing kerb stones of all types from footpath/ central Jverge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
48 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
49 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. allomplete as per direction of Engineer-in-Charge |
50 | Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class): Over 300 mm dia |
51 | Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : 600 mm dia pipe |
52 | Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : 600 mm diameter pipe |
53 | Supplying pig lead at site of work. |
54 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary anddequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test andchemical resistance test as per specifications and having manufacture"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
55 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 560 mm internal diameter |
56 | Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete |
57 | 600 mm dia RCC pipes. |
58 | 900 mm dia RCC pipes. |
59 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab includingdjoining walls upto 300 mm height including cleaning the surface before treatment b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand)dmixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
60 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading the same at C& D Waste Site near Janhagir puri Safai Karamchari Quarters at Burari Plant, including weighting at plant etc. complete as per direction of Engineer-in-Charge. Weighing and unloading the plant shall be as per procedures/ rules of the Plant Management. The rates are inclusive of all operations, labours, leads and lifts from site of work to C& D waste plant.(Processing fees at prescribed rate of C&D Waste Management plant at will be deposited by the agency and shall rembursed by the department on production of only original cash receipts).(Payment will be made on production of original Municipal dumping ground Tax receipts), the agency shalll also submit pre & post photograph in soft /hard copy.) |
61 | Providing, hoisting and fixingup to plinth level precastreinforcement cement concrete drainof size 1000mm width and depth 1800mm with wall thickness 350mm all roundincluding setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shutteringarrangement for lifting /hoisting but , excluding the cost of reinforcement, with M-25 grade ready mixed cement concrete. |
62 | (i) Designing, providing, installing, temporary, removable earth retaining structure, using steel soldier pile/H Pile with water beams, hard wood wooden lagging of required thickness including all connection, strutting, shoring or using anchors,boring holes for solider/H Piles fixing structural members upto required depth and filling holes, embedding soldier/H Pile below foundation level all as per approved structural design/drawings, particular specifications for all lifts and depth etc. complete. (ii) For the payment of temporary earth retaining structure the depth of exposed excavated vertical earth from existing ground/road level up to the level of excavation and the perimeter straight horizontal length correct to centimetre shall be measure. The are shall be worked out in sqm nearest to two decimal place. Embedded structural members below excavation level will not be measured for the purpose the payment. (iii) The Rate shall be inclusive of all materials, labour, machineries, equipment, tools, tackles, design, re-design operation wastage and other incidentals to complete the item. (iv) Note:- the scope of work shall include. (v) Approval of design/drawings/ calculation from IITs/Reputated consultant approved by Engineer-in-Charge. The scheme shall comply with safety requirement confirming to IS 3764 (Excavation work Code of safety) and other BIS Code. (vi) Carrying out detailed soil investigation at site conducting geotechnical survey to locate underground electric cables/water supply lines, sewerages lines etc to complete area under construction. (vii) Mobilisation to site all necessary machineries and equipment for execution of above item, the work shall include installation, during re-driving etc. as per the Direction of Engineer-in-Change. (viii) Providing necessary safety measure, instrumentation, equipment, record measurements for temporary earth retaining structure and to keep record to check any deformation settlement in adjacent buildings and structure etc, the ensure stability and safety. (ix) Temp structure shall be utilised till its services are required at site and shall be the property of contractor. |
63 | Add 13.34% cost index except item No. 50 |
64 | Less 9.50 % (As per Delhi Govt. Order) except item No. 50 |
65 | 11KV VCB PANEL BOARD SITC expansion of Indoor type 1 Nos VCB (outgoing) with required arrangement i.e. dummy panel, conection and wiring etc. required as per site, arc-proof floor mounted metal clad, 11KV VCB Panel with existing HT panel. designed and tested for Internal Arc Compliance towards operator safety, totally enclosed & fully interlocked, horizontal drawout, horizontal/vertical isolation type breaker as per IEC 62271-200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charging using integrated handle, and auto/manually closing breaker suitable for use on 11KV, 3 phase, 50Hz A.C. Supply with short circuit fault level of 350MVA and Internal Arc compliance of 21kA for 1-sec for all busbar/breaker/cable chamber, complete with self contained, fully interlocked, rack-in and rack-out mechanism via automatic safety-shutters, air insulated but encapsulated copper busbar of 630A Capacity, fully encapsulated vacuum breaker, featured with mechanical on/off indicator preferably with integrated spring-charging handle and hand trip device, spring release coil, continuous duty S/T coil and auxillary switch of 4NO+4NC and equipped with following switchgears and accessories i/c in connections suitable for 3X185Sqmm XLPE 11KV Cable (cable entry from bottom/top side) end termination with heat srinkable jointing material etc. as required. Internal structure of panel shall be made from corrosion proof AluZinc/GI sheets, and designed to meet Internal Arc Compliance. (Make -ABB/Schneider/BHEL/Kirloskar/Crompton) a) 1Nos. 630A VCB with fully encapsulated poles, continuous duty trip coils and preferably integrated spring-charging handle to prevent theft on site. b) 1nos. 0-100A Ammeters digital type Ammeters with site selectable scale and in-built selector switch. Accuracy Class 0.5. c) 1 No. Flush-Mounted, Numerical based, 03-OverCurrent+01-EarthFault Feeder Protection Relay, providing OverCurrent , Earth-Fault , ThreePhase Inrush Detection, CktBrkr Control, TripCkt Supervision, Three Phase & Residual Current Measurement. d) 1Set of dual core dual ratio 3 CT"s 100/50/5/5A of 5VA burden and accuracy class 0.5 for metering and 5VA burden, Class 5P10 for protection. |
66 | e) 01 set of Trafo Marshalling Box Alarm/Trip integration scheme comprising of High Speed Master Trip Relay (86), Aux. Relays and 08-Window Annunciator with Hooter to achieve OTI/WTI/Buccholz Alarm/Trip scheme f) Digital Multifunction Meter with multi-line display and capability to measure various parameters like kV, Amp, Hz, kVA, pF, THD, Max. Demand will be provided. Accuracy Class 0.5. g) Panel will be complete including flush-mounted accessories like LED indications for VCB ON, OFF, TRIP, SPRING-CHARGED, R, Y, B. Trip-Neutral-Close (TNC) for basic ON/OFF operation. Feeder panel will contain independent AC/DC MCBs for control circuit isolation and neatly laid out bunched wiring with TB arrangement inside lockable LV-box. Space heaters with thermostat and CFL/socket will be provided as per best practices. h) 1 Nos. set of gapless Surge arrestors in cable box, 2.5p.u., Class 2, Discharge Class 10kA 11 KV HT Panel as described above OIL TYPE TRANSFORMER OF 500KVA Supplying, Installation, testing and commissioning of 500 KVA, 11/0.433 KV, 3 Phase, 50Hz, Dyn11, indoor ONAN type, copper wound transformer having cable end boxes on HV side suitable for 3 x 185 Sq.mm. XLPE cable of 11KV grade and 3.5X400sq mm XLPE cable Amp. on LV side complete with all accessoriesi/c first filling of filtered dehydrated oil and confirming to IS 1180 level-2& as per specification attached complete in all respects as required at site i/c dismantling of existingtransformer etc as required. Max. Continuous Rating = 500 KVA Voltage Ratio = 11/0.433 KV Tapping (Range / Step) off Circuit Tap Changer = +5% to -10% in steps of 2.5% offload Insulation Class = A Class Application of the Transformer = Distribution Vector Group = Dyn 11 Temperature Rise at Rated Load Over Ambient Of 50ºC In Oil by Thermometer/ In Winding By Resistance = 40/45ºC Impedance (Sub. To IS Tol.) = 5.00/5.00.50% HV Termination = Cable Box LV Termination = Cable Box CopperFlexible Connection - 1 Lot Foundation as per OEM = 1 Lot 500 KVA Transformer as described above |
67 | OIL TYPE TRANSFORMER OF 500KVA Supplying, Installation, testing and commissioning of 500 KVA, 11/0.433 KV, 3 Phase, 50Hz, Dyn11, indoor ONAN type, copper wound transformer having cable end boxes on HV side suitable for 3 x 185 Sq.mm. XLPE cable of 11KV grade and 3.5X400sq mm XLPE cable Amp. on LV side complete with all accessoriesi/c first filling of filtered dehydrated oil and confirming to IS 1180 level-2& as per specification attached complete in all respects as required at site i/c dismantling of existingtransformer etc as required. a) Max. Continuous Rating = 500 KVA b) Voltage Ratio = 11/0.433 KV c) Tapping (Range / Step) off Circuit Tap Changer = +5% to -10% in steps of 2.5% offload d) Insulation Class = A Class e) Application of the Transformer = Distribution f) Vector Group = Dyn 11 g) Temperature Rise at Rated Load Over Ambient Of 50ºC h) In Oil by Thermometer/ In Winding By Resistance = 40/45ºC i) Impedance (Sub. To IS Tol.) = 5.00/5.00.50% j) HV Termination = Cable Box k) LV Termination = Cable Box l) CopperFlexible Connection - 1 Lot m) Foundation as per OEM = 1 Lot 500 KVA Transformer as described above |
68 | MAIN LTPANEL Supplying, installation, testing & commissioning of LT panel: CRCA Sheet Steel 2mm forsection with necessary stiffeners as required. Free standing, self supported, floor mounting, single front, indoor installation, non draw out and compartmented. ISMC-100 fabricated channel frame with undrilled holes.Bottom with undrilled detachable 3mm gland plate as per order .Welding will be carried out with no external deposition of welded material in particular places and there will not be any gap between the welded materials.Siemens Grey RAL 7032CRCA Structures shall be pre-treated in seven tank chemical process, heated in baking oven.Minimum 60 micron of approved shade (RAL-7032).230V AC for Main LT Panel and Other Panels415+/- 5% , 50Hz+/-5%, 3 Phase 4 Wire 50KA – 1 SecTPN Aluminum Electrolytic Grade ( E-91E) busbar shall be provided, duly supported on SMC/DMC, busbar supports & insulated with color coded heat shrinkable sleeve. Power wiring will be through Vertical Bus -Bar and 1.1 KV grade PVC multistrand copper flexible cable . All control wiring will be done by 1.5 sq mm copper flexible PVC multi strand wire. CT wiring shall be carried out with 2.5 sq mm copper flexible PVC multistrand wire.1. All R,Y,B,N phases will be Red, Yellow , Blue & Black 2.All control wiring will be Grey colour. Earthing shall be be with Green color wire.3.C.T. - Wiring through Red, Yellow, Blue, Black coloured wiring with shorting link type terminals.EPDM gasket provided at all joints, doors & covers to make panels dust & vermin proof (IP-52).Note :- Panel shall be coupled with existing panels hence required busbar strip and hardwar etc are included in the items. No extra cost shall be paid. Make :- Tricolite/Adlec/System Power Control/Supertech Control/RP Control/Universal Switchgear/Precison System Control SECTION-I INCOMINGS : ACB 1000A FP EDO, 50KA, 50HZ with Microprocessor releases based release (EMI & EMC certified) for adjustable setting for over current, earth fault & short circuit protection with 4NO+ 4NC contact,4 line LCD display with Graphical display all three current and neutral current, release should self powered requiring no external power supply, protection against phase unbalance and residual current, counting the number of operations and contact wear of arc chutes, over temperature protection with 20 fault history and event history minimum 10and inbuilt zone selective interlocking- 1 No ACB - Closing Coil, 230V AC -1 Nos. ACB - Shunt Release, 230V AC --1 Nos. ACB - Spring Charging Motor, 230V AC -1 Nos. ACB - TRIP indication Contact --1 Nos. ACB - Undervoltage release, 380-400V --1 Nos. ACB - Castell Key Lock, ABB- 1 Set Breaker Control Switch TNC, 16A -1 Set Phase Indicating Lamp ( Red / Yellow / Blue ), 230V AC- 1 Set Indication Lamp LED ON, OFF, TRIP, Spring Charged (Red ,Green, Amber, White), 230V AC, Teknic-1 Set Digital Voltmeter, Three Phase, Cl-1, SIF-96, 0-500V AC - 1 Nos. Digital Ammeter, Three Phase, Cl-1, CTR - /5A, SIF-96, 0-1000A- 1 Nos. Multifunction Meter, CTR 1A, Cl-1, Aux supply 230V AC, M1M12- 1 Nos. Metering CT, Cl-1, 15VA, Resin Cast, 1000/5A, Satya - 3 Nos. Metering CT, Cl-1, 15VA, Resin Cast for Capacitor Panel, 1000/5A -3 Nos. MCB SP - for phase supply, 6A, 10KA, C-curve -4 Nos. MCB SP for control supply, 6A, 10KA, C-curve -4 Nos. MCB SP - for AC control supply for ACB Motor, 10A, 10KA, C-curve, ABB- 2 Nos. Neutral Link - Disconnecting Type16AConnectwell- 1 Set CT Shorting Terminal, 16A, Connectwell- 1 Set Control Terminals, 2.5 sq mm, Connectwell- 1 Set BUS COUPLER ACB 1000A FP EDO, 50KA, 50Hz without release with following acessories with each ACB"s- 1 No ACB - Closing Coil, 230V AC- 1 Nos. ACB - Shunt Release, 230V AC --1 Nos. ACB - Spring Charging Motor, 230V AC -1 Nos., ACB - TRIP indication Contact -1 Nos. |
69 | ACB - Castell Key Lock - 1 Set Breaker Control Switch TNC 16A, Kaycee- 1 Set Indication Lamp LED ON, OFF, TRIP, Spring Charged (Red ,Green, Amber, White), 230V AC, Teknic- 1 Set MCB SP for control supply, 6A, 10KA, C-curve, ABB- 3 Nos. MCB SP - for AC control supply for ACB Motor, 10A, 10KA, C-curve, ABB- 3 Nos. Neutral Link - Disconnecting Type, 16A, Connectwell- 1 Set Control Terminals, 2.5 sq mm, Connectwell- 1 Set OUTGOING FEEDERS Outgoing - for APFC Panel,- MCCB ( ics=100 icu) 400A TP MCCB Microprocessor type double break (As per CPWD Specification-4.5.2.2.) for overlaod and short circuit protection , 36KA, for overcurrent, short circuit with following accessoroies each MCCB -1 Nos. MCCB - TP Spreader 1- Set MCCB - Auxiliary and Trip indication contact 1- Set MCCB - Rotary Door Interlock handle 1 Set Indication Lamp LED ON, OFF, TRIP (Red ,Green, Amber), 230V AC, - 1 Set MCB SP for control supply, 6A, 10KA, C-curve 3 Nos. Neutral Link - Disconnecting Type, 16A. Connectwell 1- Set Outgoing - for Pump Motors- -MCCB ( ics=100 icu) 200A MCCB FP Microprocessor double break (As per CPWD Specification-4.5.2.2.), 36KA, with for overcurrent, short with following accessoroies each MCCB -8 Nos. MCCB - 4P Spreaders 8 Set MCCB - Auxiliary and Trip indication contact -8 Set MCCB - Rotary Door Interlock handle -8 Set Indication Lamp LED ON, OFF, TRIP (Red ,Green, Amber), 230V AC, Teknic -8 Set Digital VAF Meter- ABB, 3 Phase, CTR 5A, Cl-1, Aux supply 230V AC-8 Set Metering CT, Cl-1, 10VA, Encapsulated, 200/5A -24 Nos. MCB SP for control supply, 6A, 10KA, C-curve, ABB- 24 Nos. Neutral Link - Disconnecting Type, 16A, Connectwell-8 Set CT Shorting Terminal, 16A, Connectwell-8 Set Outgoing - Lighting & Utilities -MCCB ( ics=100 icu) 100A MCCB FP Microprocessor type double break (As per CPWD Specification-4.5.2.2.) , 36KA, with for overcurrent, short with following accessoroies each MCCB- 1 Set MCCB - 4P Spreaders -1 Set MCCB - Auxiliary and Trip indication contact -1 Set MCCB - Rotary Door Interlock handle -1 Set Indication Lamp LED ON, OFF, TRIP (Red ,Green, Amber), 230V AC, Teknic-1 Set MCB SP for control supply, 6A, 10KA, C-curve, ABB-3 Nos. Neutral Link - Disconnecting Type, 16A, Connectwell-1 Set Utilities in Cable Section, Space Heater, 100W, 230V AC Thermostat with ON/OFF switch, 30-85 deg C MCB SP for control supply, 6A, 10KA, C-curve Neutral Link - Disconnecting Type, 16A, Connectwell Enclosure 2 mm CRCA Powder Coated fitted as above, single front, FloorMounted, for Indoor Installation approx size: Panel Size Not less than3200(L)x2200+100(H)x1000(D) mm, Busbar : Mains 1x100x12mm for Phase and 1x100x6mm for Neutral Earth Bus - 50x6mm Aluminium, Wiring - Incomers & Bus Coupler, Wiring - Outgoing, MAIN LTPANEL as described above |
70 | Supplying , Installation , testing , & commissioning of factory built floor mounted fabricated in comp. design from CRCA sheet steel of 2 mm thick for framework and covers, 3 mm thick for gland, plates i/cfinishing complete with 7 tank process for powder coating in approved shade, having 400 Amp capacity extensible type FP aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, f/b shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears auto-manual capacitor bank of170 KVAR capacity having 3 phase MPP type @ 525V (ISI marked power capacitor) with 7% detuned reactorin 10 steps(10+10+12.5 +12.5+ 12.5+12.5+ 25+25+25+25)provided with capacitor duty contactor switching of suitable rating to suppress switching of inrush current. The system shall have microprocessor based APFC relay provided in the command module for target P. F. setting with digital P. F. display. The system shall be provided with required capacity master MCCB having protection for over load, short circuit, etc. The panelprovided with exhaust fans (with thermostat) and grills for proper ventilation,minimum front area for panel 3.96 sq.mtr and minimum depth 800mm, accomdation following switchgears & accessories: Make :- Tricolite/Adlec/System Power Control/Expert Engineer/Supertech Control/Universal Switchgear/Precison System Control Incomer - 400 A TP MCCB 36KA ( ics=100 icu) 400A TP MCCB Microprocessor type double break (As per CPWD Specification-4.5.2.2.), 36KA, for overcurrent, short circuit with following accessoroies each MCCB -1 Nos. MCCB - TP Spreaders -1 Set MCCB - Auxiliary and Trip indication contact -1 Set MCCB - Rotary Door Interlock handle -1 Nos. Indicating Lamps, LED Type, Red, Yellow, Blue -1 Set Indication Lamp LED ON, OFF, TRIP (Red ,Green, Amber) -1 Set Digital VAF Meter- ABB, 3 Phase, CTR 5A, Cl-1, Aux supply 230V AC-8 Set Current Transformer, Cl-1.0, 10VA, Encapsulated - 3 Nos. APFC Relay 12-Step -1 Nos. MCB SP, 10KA, C-curve -7 Nos. Neutral Link -1 Set CT Shorting Link -1 Set Outgoing- 25KVAR CAPACITOR BANK-4 Nos ( Ics=100 Icu) MCCB TP 63 Amp, Fixed type, 18KA, with Thermal Magnetic Release with following each MCCB"s -4 Nos 25KVAR Capacitor Duty Contactor (ABB) TP with 1 NO aux contact, 230V AC-4 Nos 25KVAR 7% Detuned CopperHarmonicreactors-4 Nos 25KVAR MPP-Heavy Duty Capacitor, 525V AC-4 Nos Indicating Lamps, LED Type, ON(Red) & OFF (Green)-4 Nos Auto/Manual Selector Switch with OFF-4 Nos MCB SP, 10KA, C-curve-4 Nos Neutral Link / Disconnecting link-4 Nos |
71 | Outgoing -12.5 KVAR CAPACITOR BANK-4 Nos (Ics=100 Icu) MCCB TP 32 Amp Fixed type, 18KA, with Thermal Magnetic Release with following each MCCB"s-4 Nos 12.5 KVAR Capacitor Duty Contactor TP with 1 NO aux contact, 230V AC-4 Nos 12.5 KVAR 7% Detuned Copper Harmonic reactors-4 Nos 12.5 KVAR MPP-Heavy Duty Capacitor, 525V AC-4 Nos Indicating Lamps, LED Type, ON(Red) & OFF (Green)-4 Nos Auto/Manual Selector Switch with OFF-4 Nos MCB SP, 10KA, C-curve-4 Nos Neutral Link / Disconnecting link-4 Nos Outgoing -10 KVAR CAPACITOR BANK-2 Nos( Ics=100 Icu) MCCB TP 25 Amp Fixed type, 18KA, with Thermal Magnetic Release with following each MCCB"s -2 Nos 10 KVAR Capacitor Duty Contactor TP with 1 NO aux contact, 230V AC-2 Nos 10 KVAR 7% Detuned CopperHarmonic reactors-2 Nos 10 KVAR MPP-Heavy Duty Capacitor (ABB), 525V AC-2 Nos Indicating Lamps, LED Type, ON(Red) & OFF (Green)-2 Nos Auto/Manual Selector Switch with OFF-2 Nos MCB SP, 10KA, C-curve-2 Nos Neutral Link / Disconnecting linkv-2 Nos Fabrication Panel Size not less then Compartmentalised, CRCA 2mm, 1800 (w) x 2200 (h) x 800 (depth) mm Bus Bar 400A Aluminium Busbar 1x40x10mm Aluminium Earth Busbar40x6mm Wiring Wiring and Metering for Incomer Wiring For Capacitor O/Gs |
72 | Supplying & Laying and fixing of one number PVCsheathedXLPE insulated power cable of 1.1 KV grade of following size on wall surface as required. |
73 | 3.5 x 185 Sq.mm XLPE Al Conductor Armoured Cable |
74 | 3.5 x 400 Sq.mm XLPE Al Conductor Armoured Cable |
75 | Supplying & Laying and fixing of one number PVCsheathedXLPE insulated power cable of 1.1 KV grade of following size in existing RCC/ HUME/ METAL pipe as required. |
76 | 3.5 x 185 Sq.mm XLPE Al Conductor Armoured Cable |
77 | 3.5 x 400 Sq.mm XLPE Al Conductor Armoured Cable |
78 | Supplying & Laying and fixing of one number PVCsheathedXLPE insulated power cable of 1.1 KV grade of following size in existing open ductas required. |
79 | 3.5 x 185 Sq.mm XLPE Al Conductor Armoured Cable |
80 | 3.5 x 400 Sq.mm XLPE Al Conductor Armoured Cable |
81 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
82 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
83 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
84 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
85 | 3½ X 185 sq. mm (57mm) |
86 | 3½ X 400 sq. mm (82mm) |
87 | Supplying and Laying 3 X 185 Sqmm HT XLPE cable, 11 KV(E) with standard compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape (03 KA for 1 Sec.), cores laid up, innersheath of PVC tape, galvanised flat steel armoured and overall PVC sheathed cable confirming to IS 7098 / (Part-II) 1987 with latest ammendments complete as required in the existing masonry open duct as required |
88 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 240 sq. mm |
89 | supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 240 sq. mm |
90 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
91 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
92 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
93 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) |
94 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) |
95 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
96 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
97 | EI Work Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
98 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
99 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
100 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
101 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
102 | 20 mm |
103 | 25 mm |
104 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
105 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
106 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
107 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
108 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
109 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
110 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
111 | Supplying,installation, testing & commissioning of 20-22 Watt Energy efficient IP65 surface mounted weather proof fitting,impact proof with PC housing suitable for wet locationi/c making connections, terminationetc. complete as reqd. |
112 | Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 kV grade in the existing DWC/RCC/ HUME/ Metal pipe etc. as required. 4X25 Sq. mm |
113 | Less 9.5% on DSR Items amount(232987/-) |