Repair / Maintenance Of Control Panel And Protecting Assets With Connected Allied Misc Works Under Age ( I ) Af Manauri Repair / Maintenance Of Control Panel And Protecting Assets With Connected Allied Misc Works Under Age ( I ) Af Manau, Manauri, Allahabad-Uttar Pradesh

Military Engineer Services-MES has published Repair / Maintenance Of Control Panel And Protecting Assets With Connected Allied Misc Works Under Age ( I ) Af Manauri Repair / Maintenance Of Control Panel And Protecting Assets With Connected Allied Misc Works Under Age ( I ) Af Manau. Submission Date for this Tender is 12-10-2021. Control Panel Tenders in Manauri, Allahabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29290988
Corrigendum : Repair / Maintenance Of Control Panel And Protecting Assets With Connected Allied Misc Works Under Age ( I ) Af Manauri Repair / Maintenance Of Control Panel And Protecting Assets With Connected Allied Misc Works Under Age ( I ) Af Manau
Open Tender
Indian
Uttar Pradesh
Manauri, Allahabad
12-10-2021

Tender Details

Repair / Maintenance Of Control Panel And Protecting Assets With Connected Allied Misc Works Under Age ( I ) Af Manauri Repair / Maintenance Of Control Panel And Protecting Assets With Connected Allied Misc Works Under Age ( I ) Af Manauri

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-10-2021
2 11-Oct-2021 Due Date Extended Admin Corrigendum Date Extend 12-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 9.90 Lakhs /-

BOQ Items

Name of Work: REPAIR / MAINTENANCE OF CONTROL PANEL AND PROTECTING ASSETS WITH CONNECTED ALLIED MISC WORKS UNDER AGE(I) AF MANAURI
Sl. No. Item Description
1Excavating in trenches not exc. 1.5m wide and not exc. 1.5 metre deep and getting out in soft/loose soil complete.
2Returning filling in foundation/trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soil complete.
3Removal of surplus excavated material to a distance n.exc. 50 metre and depositing where directed at a level n.exc. 1.5 metre above starting point complete.
4M & L for sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidations, complete. (Note-Punned thickness ie 180mm will be measured and paid)
5M&L for brick protection cover over cable of old size Bricks” laid dry over LT cable width of brick shall be laid across the length of cable) complete all as specified and as directed.
6Cutting / boring under road/ path/ hard standing etc for across the light gradeGI pipe in size upto 80 mm diadrawn through cable run and making good to disturbed surface as per existed using cement concrete type B1 (1:2:4)20 mm graded aggregate etc as site required ,specified anddirected. Note ;Depth shall be taken minimum 45 CMs
7Supply, laid in trench/ thembling/ glanding/ clamping on surface of wall / beam/ roof etcin replacementto XLPE insulated armoured heavy duty electric powercable (E)with aluminium conductor 1100 volts garde cross sectional area 95 Sqmm x 4 core (earthed) complete.
8Supply, laid in trench/thembling/ glanding/ clamping on surface of wall / beam/ roof etcin replacementto XLPE insulated armoured heavy duty electric powercable (E)with aluminium conductor 1100 volts garde cross sectional area 70 Sqmm x 3.5 core (earthed) complete.
9Supply, laid in trench/thembling/ glanding/ clamping on surface of wall / beam/ roof etc in replacementto XLPE insulated armoured heavy duty electric powercable (E)with aluminium conductor 1100 volts grade cross sectional area 120 Sqmm x 3.5 core (earthed) complete.
10Supply and fixing to steel water tubing 40 MM bore, galvanised, light grade with and including requiredfittingssuch as clamp made out by GI stirp in size 32 MM , Nut bolts etc for fixing to cable protection / laid in trenches, under road crossing, fixed on poles /walls etcall as site required and directed.
11All as per item No 10 above but of size 50 MM bore dia all as directed.
12Supply and fixing in replacement timer switch (FM series) suitable for 25A /250 V AC supply, FM/1 quartz daily 240V AC base/din mounting including making connection complete all as specified and as directed. Make :L&T /Siemens/ Schneider/ C&S/ MDS
13Supply and fixing in replacement of flood light fitting LED 120 W with mounting bracket nut bolt washer to be fix on pole/ wall etc all as site making all connection using three core flexible copper cable drawn through in flexible conduit pipe from control box to light fittings complete all as directed. Make :Syska Cat Part No SSK-BLS-CF-120W or equivalent ofcat part No in make Bajaj/Philips/ Crompton/ Wipro/ Havells
14M&L for recharging to existed earthing in any type upto stranded value using required chemical such as Nacl/ MgSo4 / other approvad chemical incl reveting / welding/ boltingto earth lead incl testing etc by Tech rep with riveting bolting replacing to nut bolt and washer etcto GI earthing strip for making earth continuity from transformer / panels to earthing pit complete all as site required and directed. Note:- Payment shall be made on getting resistance value with in permissible limit only and test report in duplicate will be submitted in office by the contractor.
15Supply in replacement ofaluminium thimble / lugs suitable for thimbling to XLPE insulated cable in size 95 to 50 Sqmm x 3.5/ 4 core , 1100 volt graded Make ; Dowell"s Cat No ALS - XL 27 to 29 or equivalent in Makes as specified in Appendix "B".
16Supply in replacement ofaluminium thimble / lugs suitable for thimbling to XLPE insulated cable in size 35 to 10 Sqmm x4 core , 1100 volt graded Make ; Dowell"s Cat No ALS - XL 26 or equivalent in Makes as specified in Appendix "B".
17Supply in replacement ofaluminium thimble / lugs suitable for thimbling to XLPE insulated cable in size 185 to 120 Sqmm x 3.5/ 4 core , 1100 volt graded Make : Dowell"s Cat No ALS-XL 30 to 32 or equivalent in Makes as specified in Appendix "B".
18Supply in replacement ofaluminium thimble / lugs suitable for thimbling to XLPE insulated cable in size 300 Sqmm x 3.5/ 4 core , 1100 volt graded Make : Dowell"s Cat No ALS-XL 30 to 33 or equivalent in Makes as specified in Appendix "B".
19Supply and fix in replacement three polepower contactor type ML-6 suitable for AC1 rating 125 Amp range, 240 voltconfirm to IS/ IEC 60947-4-1 & IEC 60947-4-1 size Fr-3, 2 NO+ 2 NC including making connection complete as specified and directed. Make : L&TModel-SS90921in equivalent Siemens/ Schneider /C&S/MDS
20Labour for re-setting of AMF panel DG set in all make / model/ capacity etc by technicalrep of authorized OEM agency incl supply and fixing tominor defected spare such as push botton, ignition key, internal copper cable set, fuses/ thimbles / LED display/ relay/ time delay switch / contactor/fusesetc as required in existing specification/ make / model etc including making all connections with all other required work and spares for making serviceable complete.
21S&F in replacement MCCB, 4 pole, 400 Amp rating having breaking capacity of 36 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified and directed. Make: Legrand Cat part No 422007 or equivalent in makes as specified in list of make Appendix "B" to particular specifications.
22Same all as per item No 21 above but 250 Amps. Make: Legrand Cat part No 420249 or equivalent in makes as specified in list of make Appendix "B" to particular specifications.
23Same all as per item No 21 above but 200 Amps. Make: Legrand Cat part No 420248 or equivalent in makes as specified in list of make Appendix "B" to particular specifications.
24Same all as per item No 21 above but 160 Amps. Make: Legrand Cat part No 420097 or equivalent in makes as specified in list of make Appendix "B" to particular specifications.
25Supply and fixing in replacement ofautomatic transformer switch in sheet metal enclosure 4 poles 160 Amps capacity 440 volt 50 to 60 HZs frequency closing current 3 A/ 230 volts and tripping current 0.5 Amps/ 230 volts confirming to IEC 977-6-1 incl making all electric connections and nut bolt and washerto be fixed on surface of wall, handle to be operation complete all as directed. Make :- Havells/ L&T/ Siemens
26Supply and fixing in replacement of off load change over switch in sheet metal enclosure 4 poles 440 volts 50 to 60 HZs 400 Amps rated with making all connection and fixing accessories on surface of wall operating handle etc all confirming to IEC 977-6-1 ISI marked complete all as directed.Make :- L&T / Havells/ Siemens
27Supply and fix in replacement ofdisplay control panel suitable for DG set capacity 75 KVA Kirloskar Green model KG 82.5 W S 2 showing on alarm re-set, low oil pressure, High engine Temps, under over speed, low full level , Gen set running etc with all indication such as control on/ off, canopy lamps on / off stop push button complete all as per existing and directed.
28Supply and replacement fully automatic industrial star delta starter in sheet metal enclosure suitable for motor power 50 HP , 37.5 to50 Amps current rating 3 phase 440 volts with making all connection and fixing arrangement confirming to IEC complete all as specified and directed. Make ;- Schneider Cat No 50 TSDA, MS23A126* in equivalent Siemens/ C&S
29M&L for repair/overhauling of existing APFC panel50 KVAR TO 75 KVAR capacity/rating incl cleaning with compressed air, tightening of all electric connections, replacement of wornout/ unserviceable parts such as automatic power factor controller relays, capacitors, contactor, CTs, cable of suitable capacity/rating with suppy & replacement of lugs, re-fixing of panel & its door with proper fixing/locing arrangement, glands to be provided as required at cable entries incl any work not included above but considered necessary for efficient performance of APFC panel and testing on completion complete all as specified and as directe.Note: Spare parts such as relays, capacitors, contactors, cable shall be measured and paid separately against respective items of this schedule.
30All as per item No 29 above but capacity 125 KVAR
31Supply only following items/spares for APFC Panel:-
32Capacitor metalized poly propylene heavy duty (MPP-H) for 3 Phase 440 volts & 50 Hz system for permissible non-linear load 15% of 1 KVAR CAPACITY (Make : Havells/L&T/Schneider)
33All as per item No 31.01 above but 2 KVAR
34All as per item No 31.01 above but 3 KVAR
35All as per item No 31.01 above but 4 KVAR
36All as per item No 31.01 above but 5 KVAR
37All as per item No 31.01 above but 7.5 KVAR
38All as per item No 31.01 above but 10 KVAR
39All as per item No 31.01 above but 12.5 KVAR
40All as per item No 31.01 above but 15 KVAR
41All as per item No 31.01 above but 20 KVAR
42All as per item No 31.01 above but 25 KVAR
43Three pahase sensing 3 CT operated automatic power factor controller relay of eight stages in existing APFC panel, to control the reactive power required to obtain the target power factor, with its automatic recognition or with standard programme, able to check each and & individual capacitor bank connected. Note:-The APFC relay should ON/OFF the capacitor bank with indication of No of bank selected, PF status/indication whether it is lagging/leading/unity complete all as specified & Directed. (Make:-AE/ L&T/ Schneider/ ABB)
44Supply, connecting, testing and commissioning in replacement to lightening arresters expulsion type high tension suitable for working high tension pressure with all connecting fittings tranmission class discharge capicity 65 kilo Amps complete as sepecified and directed.
45Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix "B" to Particular specifications as approved by AGE (I) AF manauri incase not mentiooed in BOQ.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail