Repair / Maintenance Of Feeder Pillar Boxes And Ug Cable At Chnc Area Under Ge ( Utilities ) Udhampur Repair / Maintenance Of Feeder Pillar Boxes And Ug Cable At Chnc Area Under Ge ( Utilities ) Udhampur, GE UTILITIES UDHAMPUR-Jammu And Kashmir

Military Engineer Services-MES has published Repair / Maintenance Of Feeder Pillar Boxes And Ug Cable At Chnc Area Under Ge ( Utilities ) Udhampur Repair / Maintenance Of Feeder Pillar Boxes And Ug Cable At Chnc Area Under Ge ( Utilities ) Udhampur. Submission Date for this Tender is 19-10-2021. Feeder Pillar Tenders in GE UTILITIES UDHAMPUR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

29290907
Corrigendum : Repair / Maintenance Of Feeder Pillar Boxes And Ug Cable At Chnc Area Under Ge ( Utilities ) Udhampur Repair / Maintenance Of Feeder Pillar Boxes And Ug Cable At Chnc Area Under Ge ( Utilities ) Udhampur
Open Tender
Indian
Jammu And Kashmir
GE UTILITIES UDHAMPUR
19-10-2021

Tender Details

Repair / Maintenance Of Feeder Pillar Boxes And Ug Cable At Chnc Area Under Ge ( Utilities ) Udhampur Repair / Maintenance Of Feeder Pillar Boxes And Ug Cable At Chnc Area Under Ge ( Utilities ) Udhampur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair/Maintenance of feeder pillar boxes and UG cable at CHNC area under GE Utilities Udhampur.
Sl. No. Item Description
1Dehydration including filtration and cleaning of Transformer oil by dehydrating machine including testing of sample before and after dehydration and replacement of silica gel all as specified and directed by Engr-in-Charge. NOTE:- Contractor hasto arrange the dehydration machine and testing kit withoutany extra cost to the dept. Test report to be submitted after completion of job.
2Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and directed by Engr-in-Charge. NOTE:-Dielectric strength test shall be carried out at site before pouring/filling in transformers in the presence of Engr-in-Charge on the site
3Defect rectification of LT 1.1 KV cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pules, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 11 KV / 1.1 KV complete all as specified and directed by Engr-in-Charge.
4Supply, jointing and testing Straight through cable joint heat shrinkable including all material and accessories suitable for 4 core X 25-95 Sqmm XLPE cable of 1100 volts (E)grade complete all as specified and directed by Engr-in-Charge. (Make / Model - Birla 3 M Ltd, Raychem rpg/Denson) Note : Cost of Prepration of existing end deemed to be included in unit rate.
5All as item No 4 but of size 3.5 core X120sqmm- 185 sqmm.
6All as item No 4 but of size above 3.5 core X185sqmm.
7Comprehensive maintainance of oil cooled servo voltage stablizer by isolating ,disconnecting of input/output supply cable,opening of top of voltage stablizer,detecting of fault ,unserviceable component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts/ component ,including preparation of old painted steel surface by brushing /cleaning strain grease /oily spots with thinner and applying two coats of spray painting with spray machine & replacement of worn out spare parts etc, if required, complete all as specified and directed by Engr-in-Charge.
8All as per item 5 but voltage stablizer of capacity 600 KVA three phase.
9All as per item 5 but voltage stablizer of capacity 400/450 KVA three phase.
10All as per item 5 but voltage stablizer of capacity250/200 KVA three phase.
11All as per item 5 but voltage stablizer of capacity 100 KVA three phase.
12Dismantling existing ACSR conductor of any size/type from PCC/Steel poles including taking down MS works such as cross arms, clamps, hooks, stay etc from overhead line complete all as specified and directed by Engr-in-Charge.
13Taking down/Removing existing PCC/Steel poles from site complete all as specified and directed by Engr-in-Charge. Note: Damaged poles shall be removed from site as per direction of Engineer-in- charge
14Taking down existing old cross arms of MS channel or angle sections etc complete all as specified and directed by Engr-in-Charge.
15Taking down old unserviceable insulators any type and size from poles including stacking for reuse if found serviceable or removal from site complete all as specefied and directed by Engr-in-Charge.
16Replacement of lightening arrestors expulsion type complete with all fittings, suitable for 11000 Volts grade transmission class, discharge capacity 65KA including brackets, clamps, nuts, washers and connecting to 4mm dia GI earth wire complete all as specified and directed by Engr-in-Charge.
17Aluminium conductor steel reinforced (ACSR) any size on poles, stretched on LT poles without any kink and bends of various sizes complete including fixing to insulator with Aluminium binding wire complete all as specefied and directed by Engr-in-charge.
1811000 volts grade disc type insulator porcelain vitreous 145mm height, 255mm dia ball and socket type white or brown or green with tension clamps complete all as specified and directed by Engr-in-Charge.
19Pin type porcelain vitreous white or brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers and one galvanised iron nut,150mm height,150mm dia for 11000 volts grade complete all as specified and directed by Engr-in-Charge.
20Replacement of MS Channel/angle iron/flat iron of required size and bend to shape as cross arms, bracing and support including MS clamps back plates with bolts, nuts, and washers drilled for insulators including painting with two coats of synthetic enemel paint (Aluminium shade) over a coat of red oxide primer complete all as specefied and directed by Engr-in-charge.
21Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-55, 11.0 mtr long including drilling holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminious paintinternally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height of 1.5 m and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole, complete all as specified and directed by Engr-in-Charge. Note: Cost of Excavation, Earth Work and PCC in foundation are deemed to be included in quoted rate.
22MCCB 4 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA.
23MCCB 4 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA.
24MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA.
25MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA.
26MCCB 4 Pole, 415 V, Adjustable type, 350 Amps with breaking capacity 36 KA.
27Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size Complete all as specified & directed by Engr-in-Charge.
28Earthing complete with Copper earth plate electrode 60cmx60cmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using Copper strip 20×3mm as earthing lead by means ofbolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of charcoal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel, wire meshand 40 mm dia GI protection pipe light grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and directed by Engr-in-Charge. NOTES: (i) Value of earthing should be less than 1 ? (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length copper earth strip 25x3 mm.
29Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed by Engr-in-Charge.
30Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled, screwed including 3 nos. 8mm dia 25mm long hexagonal head screw & brezing all jointscomplete all as specified & directedby Engr-in-Charge.
31Taking down GI strip/ Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directedby Engr-in-Charge.
32Taking downtest point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screw all as specified and as directedby Engr-in-Charge.
33Disconnecting the bindings of loose overhead conductor of LT/HT lines from insulators and restringing the same for proper sag and rebinding with new aluminium binding wires at insulators, making all jumpers and inter connections of conductors at cut points as well as turnings using PG clamps of suitable size as per size of conductor for any type of conductor including restringing of continuous GI earth wire complete all as specified and directed by Engr-in-Charge. Note :- (i) Trimming of tree branches upto 3 m all around the conductors is deemed to be included in the rates quoted. (ii) Three ACSR conductors and two GI earth wire will be measured as one unit length for payment. (iii) Cost of PG clamps, aluminium winding wire and eye hook for GI earth wire are included in the rates coated for restringing.
34Replacement of stay assembly complete with acessories as shown in electrical plate no 1 (loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) with 16 mm dia stay rod complete all as specefied and directed by Engr-in-charge including taking down old U/S same items.
35Replecement of Lead acid maintenance free Battery12 Volts 180 AH of existing type & size suitable for Complete all as specified & directed by Engr-in-Charge. Make : EXIDE/AMCO including initial charging.
36Replecement of 32 to 160 Amp, 415 Volts, 50 Hz Power contactorof coil voltage 240 Volts, complete all as specified and directed by Engr-in-Charge. Make: L&T/Schineider/Havells
37LED indicator lamp for LT/HT panel (Red / Green/Blue/Yellow) complete all as specified and directed by Engr-in-Charge.
38Ammeter & Voltmeter Selector switch of LT /HT panel complete all as specified and directed by Engr-in-Charge.
39Multi function meter input 3 Phase 4 Wire, Voltage Range 300V AC (L-N)/520V AC(P-P), Display Parameter : Voltage (p-p) (P-L), Amp (R,Y,B) Current : 0-5A , CT 05-6000A installed on LT panel including necessory wiring, CT of required size complete all as specified and directed by Engr-in-Charge. Make: Multispan Cat Pat No AVF-19N or equivalent in Schneider, L&T
40Supply, laying, jointing and testing XLPE insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 3.5 core X 300Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed by Engr-in-Charge.
41All as per item No 34 but of size 3.5 core X 185 sqmm
42All as per item No 34 but of size 3.5 core X 95 sqmm
43All as per item No 34 but of size 3.5 core X 50 sqmm
44All as per item No 34 but of size 3.5 core X 35 sqmm
45All as per item No 34 but of size 4 core X 25 sqmm
46All as per item No 34 but of size 4 core X 16 sqmm
47Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in Hard/dense soil and getting out all as specified and directedby Engr-in-Charge.
48Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, all as specified and directedby Engr-in-Charge.
49Removal of surplus soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, all as specified and directedby Engr-in-Charge.
50Boring/auguring suitable hole & insertion of 65mm dia GI pipe including pipe not less than 600mm below existing PCC/road/hard standing complete all directedby Engr-in-Charge. Notes:- (a) Cost of equipment, tools & plants & material required for boring shall be deemed to be included in the rates quoted.
51Supply and laying sand cushioning for cable protection in trenches all as specified and directedby Engr-in-Charge.
52Supply and laying un-reinforced precast concrete LV cable cover class Type I of size with 250 X 150 X 40 mm, all as specified and directedby Engr-in-Charge.
53Taking downthe existing cables from trenches of any size all as specified and directedby Engr-in-Charge.
54Supply ,installation ,testing and commissioningin replacement of feeder pillar boardKiosktype ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor typeweather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatmentand lifting channel, fully compartmentalized design complete Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed by Engr-in-Charge.
55Material and labour for preparation of old painted steel surface by brushing /cleaning strain grease /oily spots with thinner and two coats of spray painting with spray machine to LT panel board ,Bus bar Chamber ,feeder pillar box, load line DB and power factor panel etc including disconnecting of all incoming and out going cables and re connecting after painting complete all as specified and as directed by Engr-in-Charge.
56Replacement of switch fuse unit in sheet steel enclosure powder coated, weather proof conforming to IS 13947 (Part 3) 1993 with rewireable and HRC fuse of Capacity 400 Amps, four pole, 415 volts with fuses including taking down old u/s switch fuse unit complete all as specified and directed by Engr-in-Charge.
57Onload change over switch four pole200 Amps, front handle, 415 Volt, 4 pole 50 Hz, including neccesory addition / altration in panel for mounting and providing Busbar, Nut bolts & Washerscomplete all as directed by Engr-in-Charge. Make : Havells Cat part No IHCNFO0200 or equivalent as specified in list of makes.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail