Provision Of Certain Sanctioned Works ( B / R And E / M ) At Afs Mohanbari Under Ge ( Af ) Mohanbari Provision Of Certain Sanctioned Works ( B / R And E / M ) At Afs Mohanbari Under Ge ( Af ) Mohanbari, GE (AF) Mohanbari-Assam

Military Engineer Services-MES has published Provision Of Certain Sanctioned Works ( B / R And E / M ) At Afs Mohanbari Under Ge ( Af ) Mohanbari Provision Of Certain Sanctioned Works ( B / R And E / M ) At Afs Mohanbari Under Ge ( Af ) Mohanbari. Submission Date for this Tender is 12-10-2021. Civil Work Tenders in GE (AF) Mohanbari Assam. Bidders can get complete Tender details and download the document.




Tender Notice

29290822
Corrigendum : Provision Of Certain Sanctioned Works ( B / R And E / M ) At Afs Mohanbari Under Ge ( Af ) Mohanbari Provision Of Certain Sanctioned Works ( B / R And E / M ) At Afs Mohanbari Under Ge ( Af ) Mohanbari
Open Tender
Indian
Assam
GE (AF) Mohanbari
12-10-2021

Tender Details

Provision Of Certain Sanctioned Works ( B / R And E / M ) At Afs Mohanbari Under Ge ( Af ) Mohanbari Provision Of Certain Sanctioned Works ( B / R And E / M ) At Afs Mohanbari Under Ge ( Af ) Mohanbari

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 27000.0 /-
Tender Value
INR 13.08 Lakhs /-

BOQ Items

Name of Work:PROVISION OF CERTAIN SANCTIONED WORKS (B/R AND E/M) AT AFS MOHANBARI UNDER GE (AF) MOHANBARI.
Sl. No. Item Description
1Material and labour for laying old size sub class "B" bricks, continuous brick edging; with width equal to the length of the brick; of whole bumt bricks, laid dry on edge vertically and jointed in cement mortar 1:6as in drain or any situtation with out sand cushioning complete all as specified and directed by Engineer-in-charge.
2Material and labour for plain cement concrete 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in surface channels, bed of drains including forms/moulds, foundation filling and mass concrete etc complete all as specified and directed by Engineer-in-charge.
3Material and labour for Brick work with sub class "B" old size bricks laid flat on sloped sides of drains or in any other situation , old size bricks jointed in CM (1:6) and pointed in CM (1:3) without any bedding surface and flush pointing complete all as specified and directed by Engineer-in-charge.
4Material and labour plain cement concrete type B-0 (1:2:4) using 12.5 mm graded crushed stone aggregate as in coping, junction of brick edging and brick lining for drains, benching etc including necessary form work complete all as specified and directed by Engineer-in-charge.
5Material and labour Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed by Engineer-in-charge.
6Material and labour for Mild steel TMT bars 10mm & over dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-charge.
7Material and labour for precast reinforced cement concrete (1:2:4), nominal mix, type B1 (20 mm graded stone aggs) as in cover slabs of drain, man holes etc set in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge. (Note: Reinforcement shall be measured and paid seperately)
8Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable etc and getting out in Soft/loose soil, making the surface plain complete all as specified and directed by Engineer-in-charge.
9Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and directed by Engineer-in-charge.
10Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
11Supply and fixing 300 mm bore Reinforced concrete drain pipes, Class NP3,laid in trenches and jointed with collars complete all as specified and directed by Engineer-in-charge.
12Demolition of cement concrete (unreinforced) in ground floors and paving of any description not exc 15 cm thickness (below or above GL) including removing materials obtained from demolition from worksite outside MD land any distance complete all as specified and directed by Engineer-in-charge.
13Excavating in post holes in soft/ loose soil ( or similar holes) each n exc 0.5 cu.m. getting out, returning,filling in and ramming earth or broken rubble mixed with earth around , in layer not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50 M complete all as specified and directed by Engineer-in-charge.
14Material and labour rolled Mild steel in joist, channel, angle, or tee sections, fixed independently, without conecting plates, etc. ( cut to ordinary lenghts i.e. within 20 mm of the length indicated) conforming to Fe-410-W ( Gde-E-250) quality A complete all as specified and directed by Engineer-in-charge.
15Material and labour rolled mild steel in rolled sections as in main and cross beams, hip and jack rafters ; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410-W ( Gde-E-250) quality Acomplete all as specified and directed by Engineer-in-charge.
16Material and labour for preparation of new steel surfacesof any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint (1st quality) over one coat of red oxide Zinc chromeprimerincluding cleaning, stopping and rubbing down and removingalldrops etc. complete all as specified and directed by Engineer-in-charge.
17Supply and fixedPre-painted galvalume aluminium zinc coating GI based corrugatedsteel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
18Material and labour point wiring for light point/ fan point, one light/fan point controlled by one, one wayswitch using1.5 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathedFRLS (Fire Retardant Low Smoke) cables,1100 volts grade single core in and including 20 mm dia or higher size stove enamelled concealed conduits and fittings of medium grade and terminated in moulded box duly earthed with 1.5 sqmm nominal cross sectioanl area multistranded copper conductorPVC insulated unsheathed FRLS (Fire Retardant Low Smoke) earth wire,1100 volts grade single coreand connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
19Supply and fixing switch flame proof rotary type with termination box in LM6 , 16 A, single pole 250 volts complete all as specified and directed by Engineer-in-charge.
20Supply and fixing epoxy powder coated sheet metal enclosure for DBs, double door(when MCBs to be used), Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed by Engineer-in-charge.
21Supply and fixing epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed by Engineer-in-charge.
22Supply and fixing MCB SP,10 to 32 Amps, "C" series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed by Engineer-in-charge.(Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
23Supply and fixing MCB SPN, 16 to 32 Amps,"C" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectioncomplete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
24Supply and fixingrecessed mounted CIMFR certified LED 1x16 watt flameproof batten suitable for & including single T8 tube of 16W/20W. Recommended for gas/vapor group of IIA & IIB and zone 1 & 2. IP-65 protected including necessary connection complete all as specified and directed by Engineer-in-charge.
25Supplying and fixing two single core, 4 sqmm nominal cross sectional areamultistrandedcopper conductor FRLS cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including suitable size steel conduit, medium grade of suitable size with all fittings such as bend, elbow, tee joint etc including making good to disturbed surface, including4.0 sqmm nominal cross sectional areamultistrandedcopper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified and directed by Engineer-in-charge.
26Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail