Ge ( S ) / M-38 / 2021-22 Provn Of Certain Sanctioned Works In Area Under Age B / R-I Of Ge ( S ) Mamun, GE SOUTH MAMUN-Punjab

Military Engineer Services-MES has published Ge ( S ) / M-38 / 2021-22 Provn Of Certain Sanctioned Works In Area Under Age B / R-I Of Ge ( S ) Mamun. Submission Date for this Tender is 12-10-2021. Civil Work Tenders in GE SOUTH MAMUN Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

29290815
Corrigendum : Ge ( S ) / M-38 / 2021-22 Provn Of Certain Sanctioned Works In Area Under Age B / R-I Of Ge ( S ) Mamun
Open Tender
Indian
Punjab
GE SOUTH MAMUN
12-10-2021

Tender Details

Ge ( S ) / M-38 / 2021-22 Provn Of Certain Sanctioned Works In Area Under Age B / R-I Of Ge ( S ) Mamun

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-10-2021
2 11-Oct-2021 Due Date Extended Admin Corrigendum Date Extend 12-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work :PROVN OF CERTAIN SANCTIONED WORKS IN AREA UNDER AGE B/R-I OF GE (S) MAMUN
Sl. No. Item Description
1Surface dressing n. exc. 15 cm deep and getting out in any type of soil complete all as specified and directed.
2Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
3Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
4M&L Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and removing surplus soil to a distance n. exc. 50m in soft/loose soil complete all as specified and directed.
5Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
6Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
7M&L for hard core of broken stone or boulders of gauge n. exc. 63 mm, deposited, spread and leveled in layers n. exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
8M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
9M&L for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
10M&L for PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, haunching, benching, kerbs , mud stops, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
11M&L for PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and directed.
12M&L forcement concrete as in bed to drain pipes includingforming cradles after they are laid and tested in cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregares) for 150mm bore pipe, complete all as specified and directed.
13M&L for precast cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set in CM 1:6, complete all as specified and directed.
14M&L forextra forming fair finished drain or channel 15cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed.
15M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs and mass concrete complete all as specified and directed.
16M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in beams, cantilevers, bressumers, lintels, shelves complete all as specified and directed.
17M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in chajjas complete all as specified and directed.
18M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in columns, pillars, piers, posts and struts complete all as specified and directed.
19M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like complete all as specified and directed.
20M&L for brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:6)complete all as specified and directed.
21M&L for brick work with fly ash bricks, old size bricks, straight or curved on plan any radius in half brick wall with old size bricks built in CM (1:4)complete all as specified and directed.
22M&L for brick work with sub class ‘B’ (old size) bricks, straight or curved on plan exc 6 metre mean radius, built in CM 1:6,complete all as specified and directed.
23M&L for form work to sides of flat, fair finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical to batter complete all as specified and directed.
24M&L for form work to sides and soffits of flat, fair finished surfaces of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
25M&L for form work to flat, fair finished surfaces of concrete of chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
26M&L for form work to sides of square, rectangular or polygonal, fair finished surfaces of concrete of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
27M&L for form work to soffits of flat, fair finished surfaces of concrete of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick(Horizontal or sloping) complete all as specified and directed.
28M&L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10 cm but n. exc. 20 cm wide, fair finished surfaces of concrete complete all as specified and directed.
29S&F solid PVC door frame of size 50mm x 47mm, made out of 5mm plain colour PVC sheet reinforced with MS Square tube, fixed in opening as per drawingcomplete all as specified and directed.
30S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site, complete all as per specifications & drawing.
31S&F 100mm long butt hinges, medium weight, cold rolled mild steel, (ISI) marked complete all as specified and directed.
32S&F 150 mm long extruded aluminium alloy handles, cast type, anodised complete all as specified and directed.
33S&F 150mm long, aluminium anodised, barrel tower bolts of extruded section, ISI marked,complete all as specified and directed.
34S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloycomplete all as specified and directed.
35S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
36M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shaperequired including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diacomplete all as specified and directed.
37M&L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shaperequired including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diacomplete all as specified and directed.
38S&F pressed steel frame of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate including filling of PCC 1:3:6 type C-0 (using 12.5mm graded stone aggregates) in frames/hold fast blocks, complete all as specified and directed.
39S&F box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick M S sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3complete all as specified and directed.
40S&F rolled mild steel roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410W Gde E-250 quality-A and applying two coat of synthetic enamel paint over a coat of red oxide primer on exposed surfaces complete all as specified and directed.
41S&F tubular framed steel trusses made out of MS medium grade tube (ERW or induction butt welded) upto 60mm bore conforming to I. S.1161-1979 grade St.-240 quality "A", including welding of distance pieces, cleats, special shaped washer etc. and applying two coat of synthetic enamel paint over a coat of red oxide primer on exposed surfaces complete all as specified and directed.
42S&F base palte of required thickness for supporting the steel column conforming to ASTM A36 grade including forminig holes for J-type anchore rod of reqd length and dia of nut embedded into the PCC based foundation with special shaped washers etc with supporting gusset plates properly welded with base plate and stell column etc complete all as specified and directed.
43S&F mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes conforming to Fe-410W Gde-E250 quality A complete all as specified and directed.
44S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and n. exc. 30cm long, 16mm dia of shank, complete all as specified and directed.
45M&L Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (ISI marked) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etccomplete all as specified and directed.
46M&L Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick (ISI marked) of any colour having tensile strength of 550 Mpa as in ridge/valley , gutter or straight flashings etccomplete all as specified and directed.
47M&L for 10mm thick rendering on concrete surface on top of roof slab in cement mortar 1:3, finished surface rough, including and mixing of liquid water proofing compound @ 3% by weight of cement complete all as specified and directed.
48M&L for APP modified roof treatment over existing non-accessible RCC roof slab/chajjas/canopy/parapet wall, to be executed through approved applicator of the membrane manufactured with following specifications, complete all as specified and directed :- (a) Cleaning the top surface of RCC roofing properly with water. (b)Rendering 20mm thick in CM 1:3 mixed with liquid water proofing compound on RCC roof slab whilst the surface is still green, finished the surface even and smooth without using extra cement.(c) Applying oil bound bitumen primer @ 0.30 Litre/Sqm, manufactured by the same agency as that of APP with a density 0.87-0.89 KG/Litre at 25 degree centigrade on prepared surface. (d) Laying of membrane not less than 3.0mm thick APP modified water proofing membrane weighing not less than 3.60 KG/Sqm reinforced with non woven polyster fiber weight not less than 160 Gms/Sqm using butane torch by torch application with 10cm overlap and 15cm end lap.(e) Top of membrane shall be provided with solar reflective bituminous aluminum paint @ 0.10 KG/Sqm as prescribed by manufacturer of membrane. (e) APP Membrane shall be stick inside parapet where available by chase cutting and sealed with PCC 1:2:4,type B-0.
49M&L for 25mm thick PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in floors, including finish the top surface of concrete even and smooth without using extra cement complete all as specified and directed.
50M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in sub base of floors complete all as specified and directed.
51M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) in sub base of floors complete all as specified and directed.
52M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in plinth protection.Concrete shall be laid in alternate bays n.exc 3 m in length finished fair and even including provision of joints of 6 mm wide and 10 mm deep along the wall and bays filled with bitumen mastic (1:3)complete all as specified and directed.
53M&L for 150 mm thick 1:3:6 type C2 (using 40 mm graded stone aggregate) as in floors/pavings/road surfaces fair finished complete all as specified and directed.
54M&L for glazed ceramic coloured tiles of size 300mm x 450mm x 7mm thick on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including rendering 10mm thick in CM 1:4 and finished rough to receive tiles including dismantling floor, hearth or wall tilingcomplete all as specified and directed.
55M&L for non skid ceramic coloured tiles 7 to 8mm thick, area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floors etc, set and jointed (joint free) in neat cement slurry and pointed in coloured cement to match the shade of tile over and including 15mm thick screed bed or bedding layers in CM 1:4 for layingfloor finishescomplete all as specified and directed.
56M&L for coloured machine pressed precast rubber moulded concrete interlocking (Grey/red/yellow) paver block of any shape and size with 6-8mm white cement layer mixed with pigment and coated with epoxy coating having high glossy finish confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid dry over and including 50 mm thick screened river washed sand cushion, complete all as specified and directed.
57M&L for stone sett flooring with granite or basalt stone setts of size 200mm to 250mm long, 150mm to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardener 5% by weight of cement and struck flush complete all as specified and directed.
58M&L for edge stone to flooring with granite or basalt stone setts of size 250mm to 300mm long, 150mm to 200mm wide and 450mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardener 5% by weight of cement and struck flush complete all as specified and directed.
59M&L for 15mm thick rendering in two layers (base layer 10mm thick in CM 1:6 and finishing layer 5mm thick in CM 1:4) including supply and mixing of liquid water proofing compound @ 0.200 ltr per 50 kg bag of cement, on brick work or concrete surfaces of walls, finished even and smooth without using extra cement, complete all as specified and directed.
60M&L for 10mm thick rendering on faces of brick work or concrete surfaces of walls in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed.
61M&L for rendering 10 mm thick in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cementcomplete all as specified and directed.
62M&L for rendering 5mm thick in CM 1:3 on concrete surfaces of ceiling / top and sides of chajjas/facia of roof projection including necessary formwork, finishing the surface even and smooth without using extra cement, complete all as specified and directed.
63M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white washcomplete all as specified and directed.
64M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white washcomplete all as specified and directed.
65M&L for preparation of newly plastered surfaces of external wall and applying two coats of cement base paint including curing before and after, including a coat of alkali-resistant priming paint complete all as specified and directed.
66M&L for preparation of newly plastered surfaces of external wall and applying two coats of exterior Acrylic Emulsion paint, including a coat of alkali-resistant priming paint complete all as specified and directed.
67S&F 3.0mm thick figured (frosted) sheet glass, ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in each pane, complete all as specified and directed.
68S&F Rotational moulded polyethlene water storage tank of capacity 500 Litres, three layers (cylindrical vertical with closed top), hoisted and fixed in position, including 20mm dia PVC ball valve, high pressure of PTMT epoxy coated aluminium rod and high density plastic ball screwed for iron pipe fixed in position (min. wt. 20mm-210gm/25mm-455gm) complete all as specified in SSR Part-1 and directed.
69M&L for 15mm bore water tubes "medium grade" galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
70M&L for 20mm bore water tubes "medium grade" galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
71Cutting into existing manholes for connecting new drains, making good pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required and making good for 150mm bore pipe complete all as specified and directed.
72S&F 15mm bore bib tap, with flange, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
73S&F 15mm bore Pillar tap, cast copper alloy, fancy type, with capston head, chromium plated, screwed down, high pressure with or without letters, hot or cold with long screwed shank and fly nuts, screwed for iron pipe, complete all as specified and directed.
74S&F 15mm bore stop valve, cast copper alloy (ISI marked), screwed down, high pressure with crutch or butterfly handle, screwed both ends for pipe or for unions complete all as specified and directed.
75S&F 20mm bore stop valve, cast copper alloy (ISI marked), screwed down, high pressure with crutch or butterfly handle, screwed both ends for pipe or for unions complete all as specified and directed.
76S&F jet spray for EWC including required length of tube fixed with existing water tubing/stop cock including necessary fittings complete all as specified and directed.
77S&F PVC low level flushing cistern, valveless, syphonic action type, 10 litres capacity with inlet ball valve and handle with and including brackets and PVC bend pipe 60/90cm long etc, complete all as specified and directed.
78S&F PVC connection 15mm size of length 450mm with PTMT nuts, complete all as specified and directed.
79S&F bevelled edge mirror of size 600mm x 450mm of selected quality, 5mm thick glass with PVC frame with PVC beading, fixed with chromium plated brass screws and cup washers, complete all as specified and directed.
80S&F brass tubular towel rail 20mm dia D-type 60cm long between flanges, including brackets and fixed to walls complete all as specified and directed.
81S&F stainless steel soap dish approximate size 160mmx160mmx90mm complete all as specified and directed.
82S&F stainless steel gratings 75mm dia, fixed with cement mortar, complete all as specified and directed.
83S&F vitreous china wash hand basin counter type, white oval shape of size 630mm x 450mm including CP pillar tap but including CP brass waste coupling and rubber plug, porcelain stopper, a pair of CI brackets, waste pipe of 32mm dia, complete all as specified and directed.
84S&F Vitreous china wash down water closet pan (pedestal pattern), white complete including fixing to trap including PVC seat and cover with hinging device for pedestal pan and connecting etc, complete all as specified and directed.
85S&F 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid or fixed in trenches / floors/ walls, complete all as specified and directed.
86S&F 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid or fixed in trenches / floors/ walls, complete all as specified and directed.
87S&F 75mm bore PVC (SWR) bend, plain including jointing with solvent cement, complete all as specified and directed.
88S&F 110mm bore PVC (SWR) bend, plain including jointing with solvent cement, complete all as specified and directed.
89S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed.
90S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
91M&L for reinforced cement concrete pipes with collers, class NP2, laid in trenches and jointed for 150mm bore complete all as specified and directed.
92M&L for point wiring for one light point / fan point / bell point controlled by one switch with 1.5 Sqmm PVC insulated unsheathed copper conductor single core multistranded FRLS cable and 1.5 Sqmm PVC insulated unsheathed copper conductor single core multistranded FRLS (green colour) cable as earth lead drawn in and including connected non metallic rigid PVC conduit including CI/MS terminal box of required size including 3mm thick plastic laminated top sheet cover including cutting chases to walls and making good the disturbed surfaces to match with the existing specifications, complete all as specified and directed.
93S&F Switch piano flush button, single pole, one way, 5 Amps, 230 Volts AC with polycarbonate body,complete all as specified and directed.
94S&F ceiling rose, surface bakelite, 3 terminals, 230 Volts AC with polycarbonate body, complete all as specified and directed.
95S&F surface mounted 1x10 Watt LED tube light fittings (2 feet long), prewired, decorative luminaire with inbuilt LED tube rod and acrylic cover with all accessories and making connection using 3 core, 0.50 sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc, complete all as specified and directed. Note :- CA number shall be written on each fitting before installation.
96S&F surface mounted 1x20 Watt LED tube light fittings (4 feet long), prewired, decorative luminaire with inbuilt LED tube rod and acrylic cover with all accessories and making connection using 3 core, 0.50 sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc, complete all as specified and directed. Note :- CA number shall be written on each fitting before installation.
97Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable , with aluminium conductor of size 10 Sqmm x 2 core complete all as specified and directed. Note:-Excavation andearth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
98M&L for dry clean fine river sand as in sand cushioningto underground cable 8cm below and 15cm above the cable including punning down ofsand layer complete all as specified and directed. Note :- Punnedthickness shall only be measured and paid.
99M&L for brick protection with sub class "B" old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
100M&L for 25 mm bore galvanised steel tubing, light grade, with all fittings, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall complete all as specified and directed.
101M&L for 40mm bore galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings such as MS clamps of size 25mm x 4mm, nuts, bolts, washers etc, complete all as specified and directed.