Military Engineer Services-MES has published Ge U(N) 55 2021 22 Repair To Roof Treatment Roofing Internal Plastering Of Shafts False Ceiling Rainwater Pipes Including Internal Water Supply For Certain Otm And Md Accn Of Krimchi Area Under Age B R Ii Of Ge (N) Udhampur Ge U(N) 55 2021 22 Repair To . Submission Date for this Tender is 20-10-2021. Shed Construction Tenders in GE NORTH UDHAMPUR Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-Oct-2021 | Revised BOQ and Sch of Credit | BOQ | 13-10-2021 |
2 | 13-Oct-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-10-2021 |
Sl. No. | Item Description |
1 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided and removing the demolished material out side the MOD land complete all asdirected by Engineer-in-Charge. |
2 | M&L for preparing RCC roof slab top by wire brushing and cleaning the dust and forign material etc complete and providing 15 mm thick cement mortar plaster on fair faces of concrete surfaces, finished even and smooth (without using extra cement) in cement mortar (1:3) for roof treatment ,including use ofWPCand applying a coat of hot blown bitumen 85/25 grade @ 1.2 Kg per Sqm over coat of bitumen primer @ 0.40 Ltrs/Sqm and there after laying of a layer of APP based polymenic membrane (five layered with centre core as 100microns, high molecular high density ployethlene film) minimum weighing 3.5 Kg/Sqm and reinforced with polyster non woen fabricd (wt not less than 150 gms/Sqm laid on bituminous surface by press application method with 75 mm side ov erlap and 100mm end overlap the membrane has to be laid with LPG torch application and overlaps sealed and finished neat, after that applying one coat of bitumen, 85/25 grade on top surface @ @ 1.20 kg/Sqm and blinded with premier dry sand@ 0.5 kg/Sqm dusted over bitumen coat, complete all as specified and as directed.Note :- Water proofing treatment will be carried out only by authorised specialized agency and shall render a five years warranty for rectification of any defect if occurred at a later stage, contractor shall produce documentary evidence that the work has only been carried out by authorised person before claiming of any payment |
3 | M&L for 25cmx25cmx22mm Thick Cement Concrete tiles with grey cement and no pigment , machine pressed, set jointed and pointed in neat cement slurry in floors, terrace over and including 20mm thick bedding layer in CM 1:4. complete all as specified and directed by Engr-in-charge. |
4 | M&L for apply two coats of Aluminium paint on roof surface,complete all as specified and directed by Engr-in-charge. |
5 | Dismantling asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings ,complete all as specified and directed by Engr-in-charge. |
6 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws ,complete all as specified and directed by Engr-in-charge. |
7 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws,complete all as specified and directed by Engr-in-charge. |
8 | M&L for 6mm thick non asbestos cement corrugated or semi corrugated sheets in roof, walls etc fixed with "L" type or "J" type hoks or cranked hookboltsnon asbestos complete all as specified and directed by Engr-in-charge. |
9 | All as per SI No item No 8 above but except sheet complete all as specified and directed by Engr-in-charge. |
10 | M&L for 6mm thick non asbestos cement two pieces adjustable plain wing ridge for corrugatedor semi corrugated sheets fixed with "L" type or "J" type or cranked hook bolts complete all as specified and directed by Engr-in-charge |
11 | Dismantling wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets,complete all as specified and directed by Engr-in-charge |
12 | S&F non asbestos fibre Cement board ceiling 4mm, thick in 600x600mm panel designed ceiling conforming to IS-14862 type B category threeincluding GI frame work with size of grid 605mm 605mm including all accessories, the fibre sheet should be fire resistant, water resistant, termite resistant, environment friendly & 100% asbestos free, complete all as specified and as directed by Engr-in-Charge |
13 | M&Lfor 4mm thick non AC board fixed with screw complete all as specified and as directed by Engr-in-Charge |
14 | Taking down cement plaster any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed by Engr-in-Charge |
15 | M&L for rendering 10mm thick on fair faces of brick/concrete surfaces in cement mortar 1:4, with water proofing compound (WPC shall be measured separately)complete all as specified and as directed by Engr-in-ChargeNOTE WPC shall be paid and measured seprately in concern item |
16 | M&L for cement plaster (10+5)mm thick on fair faces of brick/conc surfaces of walls in cement mortar 1:6 finished fair and even complete all as specified and as directed by Engr-in-Charge |
17 | Supply only integral water proofing compound complete all as specified and as directed by Engr-in-Charge |
18 | M&L for preparation of new plastered surfaces of walland applying two coat of oil bound distemperover one coat of primer , including 2mm to 3mm thick wall care putty complete all as specified and directed by Engr-in Charge .. |
19 | M&L for two coat of cement base paint over newly plastered surfaces of wallover a coat of primer over including 2mm to 3mmthick wall careputty preparing surfaces complete all as specified & directed by Engr-in-Charge. |
20 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15mm & 20 mm dia complete all as specified and as directed by Engr-in-Charge |
21 | S&F Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 15mm bore complete all as specified and as directed by Engr-in-Charge |
22 | Description all as per Srlitem No 21 above but of 20 mm bore complete all as specified and as directed by Engr-in-Charge |
23 | Fixing only steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia15 mm,complete all as specified and as directed by Engr-in-Charge |
24 | Description all as per Srl item No 23 above but of 20 mm bore complete all as specified and as directed by Engr-in-Charge |
25 | S&F Rotational moulded PVC water tanks three layered white of Cap 1000 Ltrs cylindrical vertical with closed top hoisted and fixed in position all as spd in SSR Part incl fixing of 20mm PTMT float valve medium grade dismanteling of existing unserviceable water tanks and removal from site complete all as specified and as directed by Engr-in-Charge |
26 | S&F Rotational moulded PVC water tanks three layered whiteof Cap 500 Ltrs cylindrical vertical with closed top hoisted and fixed in position all as spd in SSR Part incl fixing of 20mm PTMT float valve medium grade & dismanteling of existing unserviceable water tanks and removal from site complete all as specified and as directed by Engr-in-Charge |
27 | Disconnecting existing tanks , setting side for repairing, cleaning etc and hoisting after cleaning and removing allscale & dirt etc from tanksand from mouth of circulating pipe etc of capacity upto and including 500 ltrs and endorsed the word "CLEANED ON WITH DATE" with white paint including replacement of broken / unserviceable fitting such as Elbow, Tee, socket, nipple of any size etc complete all as specified and as directed by Engr-in-Charge |
28 | Description all as per Srl item No 27 here in before but of capacity exc 500 ltrs and upto & including 1000 Ltrs and endorsed the word " CLEANED ON WITH DATE" with white paint including replaceent of broken / unserviceable fitting such as Elbow, Tee, socket, nipple of any size etccomplete all as specified and as directed by Engr-in-Charge |
29 | S&F stop valve cast copper alloy, secured down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed of size 20mm bore dia complete all as specified and as directed by Engr-in-Charge |
30 | Description all as per item No 30 above but of 15 mm bore complete all as specified and as directed by Engr-in-Charge |
31 | Stack clamps made out of 50mm by 5mm thick stainless steel and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100/110mm bore pipe fixed in repair, complete all as specified and directed by Engineer-in-Charge. |
32 | S&F 110mm bore PVC (SWR)pipes single socketed in any length with rubber ring joints fixed to wallcomplete all as specified and directed by Engineer-in-Charge. |
33 | S&F 110mm borePVC (SWR)bends/shoe any radius fixed in repair complete all as specified and directed by Engineer-in-Charge. |
34 | Demolition of cement concrete in ground floor and paving n.exc15 cm thickness below or G.L complete all as specified and directed by Engineer-in-Charge. |
35 | M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
36 | S&F in repair GI bend 15mm dia |