Maintenance Of Street Lighting On Various Roads In Various Sectors At Chandigarh. Replacement Of Accidental Pole And Defunct Led Driver On Daria Road And Manimajra Police Road U.T. Chandigarh. , Chandigarh-Chandigarh

Chandigarh Administration Engineering Department has published Maintenance Of Street Lighting On Various Roads In Various Sectors At Chandigarh. Replacement Of Accidental Pole And Defunct Led Driver On Daria Road And Manimajra Police Road U.T. Chandigarh. . Submission Date for this Tender is 28-09-2021. Street Lighting Tenders in Chandigarh Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

29281421
Maintenance Of Street Lighting On Various Roads In Various Sectors At Chandigarh. Replacement Of Accidental Pole And Defunct Led Driver On Daria Road And Manimajra Police Road U.T. Chandigarh.
Open Tender
Indian
Chandigarh
Chandigarh
28-09-2021

Tender Details

Maintenance Of Street Lighting On Various Roads In Various Sectors At Chandigarh. Replacement Of Accidental Pole And Defunct Led Driver On Daria Road And Manimajra Police Road U.T. Chandigarh.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 2.86 Lakhs /-

BOQ Items

Name of Work:- MAINTENANCE OF STREET LIGHTING ON VARIOUS ROADS IN VARIOUS SECTORS AT CHANDIGARH. (REPLACEMENT OF ACCIDENTAL POLE AND DEFUNCT LED DRIVER ON DARIA ROAD AND MANIMAJRA POLICE ROAD U.T. CHANDIGARH).
Sl. No. Item Description
1Foundation for 7 Mtr. Octagonal Pole:- Design & casting of foundation with M20 cement Concrete & steel reinforcement suitable for installation of 7 mtr. Octagonal Pole. DSR Item No. 2.8.1 (Civil Work) Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil (Size 0.7m x 0.7m x 1.65 m = 0.81 cum (3 Nos. x 0.81 cum =2.43)
2DSR Item No. 4.1.11 (Civil Work) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size)(0.7mx0.7mx0.10m =0.049 cum.) (3 nos.x0.049 = 0.147)
3DSR Item No. 5.22.6 (Civil Work) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars 2.Vertical Bar 12mm dia =4 nos.x1.55=6.2 r.mtr. @0.89 kg per mtr. =5.52 kg 3.Horizontal Ring 8mm dia =11 nos.x2=22 r.mtr.@0.390kg per mtr.=8.58kg Total (5.52+8.58=14.1+5%=14.8 wastage = 03 nos. x14.81=44.43)
4DSR Item No. 5.2 (Civil Work) Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Size 0.5x0.5x1.55 = 0.388 cum Total (03 nos.x 0.388= 1.164 cum.)
5DSR Item No. 5.9.1 (Civil Work) Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete Size .5x0.5x1.5 = 4 (0.5 x 1.5) = 3 x 3 = 9 Sq. Mtr.
6DSR Item No. 2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
7Single pole
8DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator).
94 way (4 + 12), Double door
10S/E of 7 Meter long Hot dipped Galvanized pole of octagonal cross-section continuously tapered made out from high tensile steel of minimum thickness 3mm complete with the base plate of minimum size 200 mm x 200 mm x 12 mm along with inbuilt lockable junction box which should be operated with single key with connectors of Elmax / Connectwell / Essen / Wago make for the cable termination and two or three terminals and one no. 6 amps. Single pole MCB for each luminaire. The diameter across from the dimensions of the base and top should be minimum 130mm and 70mm A/F (Across Face). The pole should be provided with metallic sleeve with cutting of Chandigarh ‘open hand’ mark. Sleeve should be backlit using environment proof LED modules. (As per Complete Item No. 4 of the DNIT).
11G.I. PIPEBRACKET. Supply, Fabrication and erection of GI pipe (medium class) bracket with suitable size of nipple for mounting the 45W/70W LED S/L fitting with the following specifications. The bracket shall be made by GI pipe of 2” dia with an angle of inclination of as 105 degree to vertical.The weight of 2” dia G.I. pipe per Mtr. 5.26 Kg. + 10% for 4” dia G.I. pipe per Mtr. (8.53Kg. + 10% ) respectively. (As per Complete Item No. 5 of the DNIT).
12Supply, Erection, Testing & Commissioning of 45 Watt LED Street Light fitting complete with pressure die cast aluminum housing, Electronic LED Driver Power supply & related accessories with the following specifications to be installed on existing GI pipe bracket on the existing S/L pole up to 5 meter long. The job includes the cost of making connections with 3x1.5 sq. mm. copper wire, testing, commissioning and labour etc. as required to the entire satisfaction of Engineer in Charge. The LED Street Light fitting should be of Philips/ Wipro/ Bajaj make only. (As per Complete Item No. 6 of the DNIT).
13Providing and fixing following rating MCCB 4 pole 415 Volt (Thermal magnetic / microprocessor release) with MS enclosure for Over load, short circuit and inbuilt earth protection, 25 KA Breaking capacity (Ics=100% Icu) with positive isolation. The overload release shall be of adjustable type suitable for isolation. (As per Complete Item No. 7 of the DNIT).
14100 Amp 4 Pole 25 KA MCCB with Thermal Magnetic release.
15Supply and Erection of LED street light driver at a height of 7.50/9 mtr. long pole with the help of crane. The job include cost of dismantling and erection of existing fitting etc required to complete the job. The job includes the cost of making connections, testing, commissioning, labour and other petty material etc. as required to the entire satisfaction of Engineer-in-Charge. The Driver should be of Bajaj/ Wipro/ Philips/ Surya make.
16LED diver of 45 watt
17Supply and Laying of 3x1.5 mm2 copper wire with the help of crane for 7 to 12 mtr. Long Steel Tubular Pole. The job includes cost of making incoming and outgoing connection etc. after dismantling the existing LED fitting, erection of the same and petty material required to complete the job.
18Supply and erection of ASTRO TIMER SWITCH OF RATING AC3 70 AMP RATING AND 100 AMPS RATING FOR AC1 unit suitable for 3 phase switching on/off. The job includes cost of one no. timer of L&T make T2DDT7and 1 no. 3 phase contactor MO 70 CS94574 with built in SURGE SUPPRESSOR for coil of 220 Volt 50/60 Hz Rating L&T MO/ Siemens 3TF/ ABB AX series. (As per Complete Item No. 10 of the DNIT).
19Dismantling of existing octagonal pole 7 mtr long with help of crane The Job include cost of dismantling of existing incoming and out going connection from the junction box .The cost includes carriage, all labour and material including installation of Pole to the entire satisfaction of the Engineer-in-Charge
20Dismantling and erectionof existing G.I. bracket at a height of octagonal pole 7 mtr long .The cost includes all labour and petting material require to complete the job tothe entire satisfaction of the Engineer-in-Charge.