Spl Repairs To Roof Sheets Bldg No T-1, T-2, T-4 And T-100 At Zone-1, Spl Repairs / Replacement Of Old Unserviceable Lt Panels At Zone 1 Area And Provn Of Double Row Fan And Exhaust Fan With New Connection At Otm Area Bldg At 4 Csr Under Ge ( S ) , GE South Tezpur-Assam

Military Engineer Services-MES has published Spl Repairs To Roof Sheets Bldg No T-1, T-2, T-4 And T-100 At Zone-1, Spl Repairs / Replacement Of Old Unserviceable Lt Panels At Zone 1 Area And Provn Of Double Row Fan And Exhaust Fan With New Connection At Otm Area Bldg At 4 Csr Under Ge ( S ) . Submission Date for this Tender is 18-10-2021. Electrical Panel Tenders in GE South Tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

29273634
Corrigendum : Spl Repairs To Roof Sheets Bldg No T-1, T-2, T-4 And T-100 At Zone-1, Spl Repairs / Replacement Of Old Unserviceable Lt Panels At Zone 1 Area And Provn Of Double Row Fan And Exhaust Fan With New Connection At Otm Area Bldg At 4 Csr Under Ge ( S )
Open Tender
Indian
Assam
GE South Tezpur
18-10-2021

Tender Details

Spl Repairs To Roof Sheets Bldg No T-1, T-2, T-4 And T-100 At Zone-1, Spl Repairs / Replacement Of Old Unserviceable Lt Panels At Zone 1 Area And Provn Of Double Row Fan And Exhaust Fan With New Connection At Otm Area Bldg At 4 Csr Under Ge ( S ) Tez Spl Repairs To Roof Sheets Bldg No T-1, T-2, T-4 And T-100 At Zone-1, Spl Repairs / Replacement Of Old Unserviceable Lt Panels At Zone 1 Area And Provn Of Double Row Fan And Exhaust Fan With New Connection At Otm Area Bldg At 4 Csr Under Ge ( S ) Tez

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Oct-2021 Amdt BOQ BOQ 11-10-2021
2 11-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 87550.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPL REPAIRS TO ROOF SHEETS BLDG NO. T-1, T-2, T-4 AND T-100 AT ZONE-1, SPL REPAIRS/ REPLACEMENT OF OLD UNSERVICEABLE LT PANELS AT ZONE 1 AREAAND PROVN OF DOUBLE ROW FAN AND EXHAUST FAN WITH NEW CONNECTION AT OTM AREA BLDG AT 4 CSRUNDER GE (S) TEZPUR
Sl. No. Item Description
1Dismantling asbestos cement corrugated semi corrugated etc sheets in roof covering.
2Dismanting timber scantling 40 Sqcm and over in secion in any position inframed work
3Ditto all as per Ser Itme no 2 above but In fillests, rails , posts, refters and purlins etc under 40 sqcm in section unframed work
4Dismanting wall /ceiling board (Fibre pulp insulation) or insulation boards any thickness including cover filters
5M&L 2nd class HW in scantling fixed clean swan in framed work complete all as specified and directed
6M&L 2nd CL HW plain fillets square, rectangular or triangular in section clean sawn sectional area exe 6 sqcm & n exe 13 sqcm fixed with nails
7S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W(Gde -E-250 quality A) complete all as specified and directed.
8S&F in repair Wire netting of galvanised steel wire 0.71mm dia fixed with tinned tacks of wire staples and size of mess 12mm comjplete all as specified and directed.
9S&F Exposed GI powder coated snap grid frame for false ceiling 600x600mm size of wall angle 25x25x0.25mm size of cross tee and main tee26x24x0.25mmand 32mm x 24mm x 0.25mmwith 1.5mm dia double GI suspentor including supply and fixing of 4mm thick E Board decorative type in false ceiling including fixing arrangement from steel tress any type of tress.
10S&F 0.5mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour ,tensile strength of 550Mpa as in roof covering Including end of creep length 200mm to 250mm etcfixed with self tapping screws as specified. Note : Creep length shall be measured and paid in same item.
11All as per item No.10 above but plain sheet for ridge ,gutter etc fixed with self tapping screws as specified.
12M&L for preparation of new wooden surface and applying two coat of creosote on any description and girth not otherwise described.
13M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
14M & Lfor point wiring for one fan point with 1.5 sqmm cable PVC insulated copper conductor multi stranded as per IS-694 FRLS cable controlled by one way switch, drawn through and including PVC casing caping (on Wall/Roof/Ceiling/GI Pipe) with all accessories incl 1.5 sqmm multi strand copper conductor cable (green colour) PVC insulated andunsheathed for earth continuity connected to common earth dolly and PVC box 4" x 4" fixed to wall for mounting of fittings such as Switches all as specified and directed.
15Supply and fix switch 5 amps switch flush type one way single pole.
16S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd
17S& F Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including provision of fan hook on ceiling/GI Pipe, drilliing holes, fixing with nut bolts and washers all as specified and directed. Make:- Havells,Cat No-Fusion 50or equivalent in Bajaj/Crompton/Usha
18Takiingdown and Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan all as directed
19Supply and fixing Tubes, "light grade"50 mm dia bore galvanised, with all fittings, welding, fixed in wallsboth side of pipe and drilling forhanging of Ceiling fan on GI pipe including making good to disturbed surfaces of walls/floors complete all as directed
20Supply and fix Heavy duty exhaust fan, steel body AC single Phase. 230V of size 300m sweep, 900 RPM with, blades, and frame and louvers Make:- Havells,Cat No-Turbo Force SPor equivalent in Bajaj/Crompton/Usha
21Supply and fix Ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as directed
22Supply, Installation, testing and commisioning inreplacement of LT Feeder Pillar Box 440 V, 3 Phase, 4 Wire, 50 Hz Outdoor, weather Proof Cubical Type cabinet,platform mountedhight 45 Cm above normal GLfactory madeof MS Sheet 3.15 mm thick, dust and vermin proof conforming to IP – 54 protection CRCA MS sheet of overhall minium size 750 x 600 mm x 450 mm, full built upon sutaible size of angle iron of size 50 x 50 x 6 mm, having front and rear hinged covered from all side with front and back, open able doors, lifting lugs (02 nos), arrengment to be connect earthing strip at rear side bottom detachable gland plate complete with sutaible size zinc plated and passivated nut, bolts,spring and washers having front hinged covers chemically treated with MSR solution for anticorrosive treatment, epooxy powder coated , in required capacity CTs, PTs, to space for fixing MCCB 4 Pole in required rating- 4 nos and duly painted with two coats of synthetic enamel paint over a coat of red oxide and embedded in PCC Block 30 x 30 x 60 cm PCC 1:2:4 in ground with suitable size of nuts and bolts, complete. Feeder Pillar Box comprising of following: -(a)S&F04 Nos bus bars made out by copper conductor in colour coading ,ratednot less than 400 Amps in equal size supported at required intervals on heat shirnkable insulators and PVC sleeving. -01 set of 04 b) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 250 Amps,having repturing capacity 36 KA - 01 No as incomer Make - Schneider cat No. LV 431780in equivelent L&T / Seimens(c) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 125 Amps,having repturing capacity 25 KA - 01 No Make -Schneider cat No. LV429775 in equvelent in L&T / Seimens (d) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 100 Amps,having repturing capacity 25 KA - 02 No Make -Schneider cat No. LV429775 in equvelent in L&T / Seimens (f) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 63 Amps,having repturing capacity 25 KA - 02 No Make -Schneider cat No. LV429775 in equvelent in L&T / Seimens (g)S&FLED indicating lamps of "R" "Y" and "B" phase with selector switch.Set of three -01 (h)S&FDigital volts meter rating 0 to 500 volts with selector switches - 01 No Make :- L&Tcat no WDS 301FE 00/AE (i) S&F Digital ameter rating 0 to 500 Amps with selector switch -01 No Make :- L&T cat no WDS 301OCA 00/ or equivalent make in Havells/AE/C&S
23Supply, Installation, testing and commisioning in replacement of LT Panel in cubical housing cabinet, out door type, platform mounted (minium height 45 CM above normal GL,CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 mm thick CRCA MS sheet of overhallminium size 1.8RMx 1.50 RM x 0.80 RM verticallyand full built upon suitable size of angle iron frame work, having front and rear hinged openable doors ,liffting lugs (02 Nos) ,arrengement to be connect earthing strip at rear side,bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuitshall be connected bymulti strandered copper conductor flexible wire 1.5 Sqmm in proper colour coading and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire systemall internal connection shuold be made by using aluminium strip in suitable size and making incoming and outgoing connection using suitable size of gland, thembling , allnecessary foundation work complete with CTs , PTs , phase previntor etc all required accessories andcomprising the following items:-
24Note for Sr item No 23 :(i)The approvel of LT panel drawing shall be taken from Engr-in-charge by contractorbefore placing the order (ii) Space provision for fixing and all MCCB shall be confirming to Icu 100% and IEC 60947 -2 . in compact seriesMake : MCCB- L&T / Legrand/ Sciemens/schneider (a)S&F04 Nos bus bars made out by copper conductor in colour coading ,rated 600 Amps in equal size supported at required intervals on heat shirnkable insulators and PVC sleeving. -01 set of 04 (b) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 400 Amps,having repturing capacity 36 KA - 01 No as incomer Make - Schneider cat No. LV 431780in equivelentL&T / Seimens (c) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 125 Amps,having repturing capacity 36 KA - 01 NoMake - Schneider cat No. LV 431780in equivelent L&T / Seimens(d) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 100 Amps,having repturing capacity 25 KA - 03 No Make -Schneider cat No. LV429775 in equvelent in L&T / Seimens (e) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 63 Amps,having repturing capacity 25 KA - 03 No Make -Schneider cat No. LV429775 in equvelent in L&T / Seimens (f)S&FLED indicating lamps of "R" "Y" and "B" phase with selector switch.Set of three -01 (f)S&F Digital volts meter rating 0 to 500 volts with selector switches - 01 No Make :- L&Tcat no WDS 301FE 00/AE (g) S&FDigital ameter rating 0 to 500 Amps with selector switch -01 No Make :- L&T cat no WDS 301OCA 00/ AE (h)Change Over switch Inbuilt 250 Amp-01 Nos Make :- L&T/ Simmens
25Supply, Installation, testing and commisioning in replacement of LT Panel in cubical housing cabinet, out door type, platform mounted (minium height 45 CM above normal GL,CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 mm thick CRCA MS sheet of overhallminium size 1.5RMx 1.2 RM x 0.90 RM verticallyand full built upon suitable size of angle iron frame work, having front and rear hinged openable doors ,liffting lugs (02 Nos) ,arrengement to be connect earthing strip at rear side,bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuitshall be connected bymulti strandered copper conductor flexible wire 1.5 Sqmm in proper colour coading and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire systemall internal connection shuold be made by using aluminium strip in suitable size and making incoming and outgoing connection using suitable size of gland, thembling , allnecessary foundation work complete with CTs , PTs , phase previntor etc all required accessories andcomprising the following items:-
26Note for Sr item No 24 :(i)The approvel of LT panel drawing shall be taken from Engr-in-charge by contractorbefore placing the order (ii) Space provision for fixing and all MCCB shall be confirming to Icu 100% and IEC 60947 -2 . in compact seriesMake : MCCB- L&T / Legrand/ Sciemens/schneider (a)S&F04 Nos bus bars made out by copper conductor in colour coading ,rated 600 Amps in equal size supported at required intervals on heat shirnkable insulators and PVC sleeving. -01 set of 04 (b) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 400 Amps,having repturing capacity 36 KA - 01 No as incomer Make - Schneider cat No. LV 431780in equivelentL&T / Seimens (c) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 160 Amps,having repturing capacity 36 KA - 01 NoMake - Schneider cat No. LV 431780in equivelent L&T / Seimens(d) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 100 Amps,having repturing capacity 25 KA - 03 No Make -Schneider cat No. LV429775 in equvelent in L&T / Seimens (e) S&F MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 63 Amps,having repturing capacity 25 KA - 04 No Make -Schneider cat No. LV429775 in equvelent in L&T / Seimens (f)S&FLED indicating lamps of "R" "Y" and "B" phase with selector switch.Set of three -01 (f)S&F Digital volts meter rating 0 to 500 volts with selector switches - 01 No Make :- L&Tcat no WDS 301FE 00/AE (g) S&FDigital ameter rating 0 to 500 Amps with selector switch -01 No Make :- L&T cat no WDS 301OCA 00/ AE (h)Change Over switch Inbuilt 250 Amp-01 Nos Make :- L&T/ Simmens
27Supply, Installation, testing and commisioning of LT Panel in cubical housing cabinet, in outdoor type, platform mounted CPRI approved factory made totally enclosed, dust and vermin proof made out by 2.15 mm thick CRCA MS sheet of overhallminium size 1000 mm x 800 mm x 400 mm CPRI approved factory madeverticallyand full built upon suitable size of angle iron frame work, having front and rear hinged openable doors ,liffting lugs (02 Nos) ,arrengement to be connect earthing strip at rear side,bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuitshall be connected bymulti stranded copper conductor flexible wire 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire systemall internal connection should be made by using aluminium strip in suitable size and making incoming and outgoing connection using suitable size of gland, thembling , allnecessary foundation work complete with suitable rating CTs , PTs , phase preventor etc all required accessories andcomprising the following items:-
28Note for Sr item No 25 :(i)Drawing of LT panel shall be approved by GE before orderd. (ii)All MCCB shall be confirming to Icu 100% and IEC 60947 -2 . in compact seriesMake : MCCB- L&T / Legrand/ Sciemens(a) 04 Nos bus bars made out by copper conductor in colour coding, rated 400 Amps in equal size supported at required intervals on heat shirnkable insulators and PVC sleeving. -01 set of 04(b) LED indicating lamps of "R" "Y" and "B" phase with selector switch.Set of three -01 (c) Digital Multi meter- 01 No Make :- L&T /AE(d) S&F 4 Pole MCCB 250 Amp 50 Hz 415 V , microprocessor basedwith rupturing capacity 36 KA -01 Nos (as Incomer)(e) S&F 4 Pole MCCB125 Amp 50 Hz 415, adjustable basedwith rupturing capacity 16 KA. - 02 Nos (as out going) (f) S&F 4 Pole MCCB63 Amp 50 Hz 415 V, adjustable based with rupturing capacity 16 KA.-03 Nos (01 as stand by) (g) S&F 4 Pole MCB32 Amp 50 Hz 415 V, B curve with rupturing capacity 10 KA.-02 Nos h)Change Over switch Inbuilt 250 Amp-01 Nos Make :- L&T/ Simmens/schneider/Havells
29Supply and fixing/laying/inreplacement of connecting and testing ofLT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area for following size :-(a)95 Sqmm x 3.5 core
30All as per Item No 06 above but 50 Sqmm x 4 core
31All as per Item No 06 above but25 Sqmm x 4 core
32All as per Item No 06 above but 16 Sqmm x 4 core
33All as per Item No 06 above but10 Sqmm x 4 core
34Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, etc. complete all as specified and as directed.
35Returning, fillingincluding spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soilcomplete all as specified and as directed.
36Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed..
37M&Land laying natural river clean dry send as cushioning for protection of under ground cable, including spreading and punning down all as per cluase No 3.21 of SSR part-1 complete all as specified and as directed by Engineer-in-chargeNote :-Punned thickness of sand layer shall be measured abd paid to contractor.
38M&L for Brick Sub Class "B" locally available best qualitylaid in trenches with width equal to length of the bricks, above sand cushioning for cable protection completeall as specified and as directed.
39M&L for cement conrete in foundation filling and mass concrete type C-2 in ration 1;3;6 using 40 mm graded aggregate all as directed.
40Supply and fixing/laying/inreplacement of galvanised steel water tubing light grade bore of dai 80 mm with all fittings all as site and directed. Make - Tata / Jindal / NTL
41Supply and fixing/laying/inreplacement of galvanised steel water tubing light grade bore of dai 40 mm with all fittings all as site and directed. Make - Tata / Jindal / NTL
42M&L and fixing inreplacement of earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below the normal ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to copper strip 20x3 mm as earthing lead by means of bolts, nuts and washers, check nuts made out of copper all as shown on electrical plate No.5 of SSR Part-I connected to earthing test point complete all as specified and directed.
43M&L and fixing inreplacement of advance maintenance free chemical earthingwith JMV CBE 403 enviornment friendly ring earthing system consisting each set of 03 (three) Nos of 10 (ten) feet length 40 mm dia earth eletrode made of maintenance free electrolytic grade copper earthing system of JMV make based on flat in pipe technology of 3 Mtrs length , 40 mm dia with crystalite conductive mixture COMPOUND filled withthe permanent sealings at the top & bottom with the lead terminal of 25x4 mm size copper with 2 holes of 10 mm dia at the top , to be lowered in 150 mm dai bore including filling of back fill ecofriendly earth enhancing compound tested by ROHS comply to IEC 62651-7 which should have passed leaching ,corrosion, supphur & resistivity test as per IEC 62651-7 by NABL accredit LAB/JAM plus compound in 150 mm bore in immediate contract around the earth electrode and top of the bore shall be finished with 40 mm thick PCC in 1:2:4 type B 1 over 75 mm thick PCC in 1:4:8 type D-2 and backfilly/ JAM compound shall be covererd with FRP pit cover of suitable size for each earth electrode , joint to be made by JAM weld exothermically welded technology including copper strip size 50 x 6 mm for earthing ring system and copper strip 32x6 mm size for earthing electrode to test point with saddles & porcelain insulators suitable size on wall ,earth strip protected by light grade GI pipe 40 mm dia in case of plinth protection / floor/ hard standing crossing complete all as specified and directed. Make - JMV LPS Limited / JEF/ ALCOICE / Conducrete (Ref drawing att)Note :-Earth work , PCC work,PCC cutting work by cutter & testing rate shall deemed to be included in unit rate quoted.
44M&L and fixing inreplacement of copper strip 20x3.15 mm with saddles and fixing screws etc for roof conductors above ground level all as specified and directed.
45M&L and fixing inreplacement of Test point terminal block made of gun metal or phosphorus bronze in size 75x75x25 mm drilled and screwed including 03 nos ,8 mm dai 25 mm long hex head screw complete all as specified and directed.
46Supply and fix Circuit/Sub Main Wiring with 2x4.0 Sqmm PVC insulated, FRLS, copper cable 1100 volts grade stranded copper conductor cable drawn through and including PVC concealed conduit with all fittings and accessories including PVC box (IS-14772) and 1 X 2.5 Sqmm stranded PVC unsheathed copper cable for earth continuity connected to common earth dolly.
47All as per Item No 43 but 2x6.0 sqmm+1x4.0sqmm earth wire
48S & F Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 240 volt,4 Way, IP-42 protectionand suitable for having MCB’s complete and all disturbed surfaces of wallshall be made good to match the existing wall finishes all as specified and directed by Engineer-in-charge. make- L&T/Havells/C&S/legrand/hager.
49S & F MCB TPN 40-63 10 KA "C" series 415 Volt complete all as specified and directed. Make : L&T/Standard/Havells
50S & F MCB SP 6 to 32 Amp,C series , 230 Volts completeall as specified and directed . Make - L&T/Havells/C&S/legrand/hager.Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount.Note 2-Contractor"s supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor"s firm name while carriying out any activities in defence area for better check of security purpose.