Revival Of Kenduguda Iii L.I.Project Under Mathili Block Of Malkangiri District Revival Of Kenduguda Iii L.I.Project Under Mathili Block Of Malkangiri District, Koraput-Odisha

Orissa Lift Irrigation Corporation Limited has published Revival Of Kenduguda Iii L.I.Project Under Mathili Block Of Malkangiri District Revival Of Kenduguda Iii L.I.Project Under Mathili Block Of Malkangiri District. Submission Date for this Tender is 27-09-2021. Lift Irrigation Tenders in Koraput Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

29267773
Revival Of Kenduguda Iii L.I.Project Under Mathili Block Of Malkangiri District Revival Of Kenduguda Iii L.I.Project Under Mathili Block Of Malkangiri District
Open Tender
Indian
Odisha
Koraput
27-09-2021

Tender Details

Revival Of Kenduguda Iii L.I.Project Under Mathili Block Of Malkangiri District Revival Of Kenduguda Iii L.I.Project Under Mathili Block Of Malkangiri District

Key Value

Document Fees
INR 6000 /-
EMD
INR 13845.0 /-
Tender Value
INR 13.84 Lakhs /-

BOQ Items

Name of Work:TENDER SCHEDULE FOR CONSTRUCTION OF HEAD WORK, DISTRIBUTION SYSTEM & POWER SUPPLYFOR REVIVAL OF KENDUGUDA - IIIL.I.PROJECT UNDER MATHILIBLOCK OF MALKANGIRIDISTRICT
Sl. No. Item Description
1Earth work excavation in foundation in hard soil with 50 mtr initial lead 1.5 m initial lift including rough dressing and breaking clodsto 2 cm to 7 cm and laying in layers not exceeding 0.3 m in depth as per direction of Engineer-in-charge
2Filling foundationand plinth with sand watered and rammed as per direction of Engineer-in-charge.
3Cement concrete ( 1:4:8) with 4 cm size h.g metal as per direction of engineer-in-charge.
4Cement concrete ( 1:2:4) with 12 mm size h.g Chips as per direction of engineer-in-charge.
5Rigid and smooth centering and shuttering for RCC work including false work and dismentalling them after casting including cost of materials complete in Column beams,Roof slab,Plinth Bend
6Supplying,fitting and placing oncoatedHYSD(TISCON) bar reinforcement complete as per drawing and technical specificationincluding cutting , binding , bendingand cost of binding wire.
7Brick work with C.B. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
812mm thick cement plaster (1:6 ) over brick masonary
9Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
10Filling F & P with excavated materials, moorum including watering and ramming as directed by the engineer-in-charge
11Supplying of 200 mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms. cc,of straight length of 6(six ) meter for portable water suppliers conforming to IS-4985/2000 of BIS- Amendment 2 read with Table =1 of IS specification bearing ISI marks for working pressure CI -IUO=PVC pipe to withstand pressure of 2.50 Kgf/sqcm and the specification and manufacturer name should be prominenity marked on body of each pipeas per the latest Amendment of IS 4985.it includes the cost of sockets in case of plain ended pipe Pre & Post delivery Inspection are to beconducted and should be marked on body of each pipe and report is to be obtained from CIPT ,Bhubaneswar /EPM ,Orissa , Bhubaneswarnecessary approval of authority including transporotation and laying at site all complete with cost of solvent cement.
12Supplying of 200 mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms. cc,of straight length of 6(six ) meter for portable water suppliers conforming to IS-4985/2000 of BIS- Amendment 2 read with Table =1 of IS specification bearing ISI marks for working pressure CI -IUO=PVC pipe to withstand pressure of 4.00 Kgf/sqcm and the specification and manufacturer name should be prominenity marked on body of each pipeas per the latest Amendment of IS 4985.it includes the cost of sockets in case of plain ended pipe Pre & Post delivery Inspection are to beconducted and should be marked on body of each pipe and report is to be obtained from CIPT ,Bhubaneswar /EPM ,Orissa , Bhubaneswarnecessary approval of authority including transporotation and laying at site all complete with cost of solvent cement.
13Cost of supplying transportation and fixing in proper place and position including required size full threaded TVS nut bolt , Rubber insertion & 4mm cupper wire
14Monoblock centrifugal 5 Star rated pumpset 1700 LPM at 18 Mtr. Head(10 HP)squirrel cage induction motor companion flanges and class-F insulation suitable for operation at 415 volt + 6% - 15%, 3 phase 50Hz AC power supply confirming to IS 9079/2002 with ISI mark &guarnatee period & inclusive of cost of transportation to site & the pump set should be star rated. The manufacturer should be areputed company having wide dealership network and the spare parts should be easily available. The materials of construction as given below : a) Casing: FC 200 as per IS 210/1978 b) Impeller: Bronze grade LTB - 2 of IS 318/1981 c) Shaft: High carbon steel grade 40 c 8 of IS 1570(part 2) d) Gasket: As per IS 5120/1977. NB: Pump set to be tested at PTL, OLIC, Bhubaneswar at random at contractor"s cost.
15Automatic Star Deltastarter sheet steel enclosure suitable for operation of squirrel cage induction motor upto 10 HP with 25 Amp (AC-3) contactor at 415 volt +6% - 15%, 3 phase, 50 Hz, AC supply with suitable overload relay & No volt coil with electric pnemutic timer suitable for operation at voltage range of 300-440 volt including cost of transportation to site. The starter should provide dependable protection against overload and single phasing & should be of reputed brand having wide dealership network for easy availability of spares. NB: Starter will be sent to PTL, OLIC, Bhubaneswar at random for necessary testing at the contractor"s cost.
163 ph 4 wire20-100Amp3x230Volt (P-N) current meter with ISI mark as approved by DISTCO CEDSU with matching fibre glass TP box for current meter including supplying ,testing and energisation with Kit -kat(Energy meter)
17Pannel Board made of 18 gauge C.R. sheet (18"x11"x45")size with double coat painting over one coat primerwith fitted of Denger Board.
18Motor hood cover of 18 gauge C.R. sheet(18"x18"x24") with double coat painting over one coat primer so as to cover the motor
19MS Base plate for fitting of pannel and pump as per sample
203 x 10 sqm Tarpodar Cable XLPE (Cross like polythylin) confirming to IS - 7098 (Part - II) including laying below 1 mtr of the ground & fitting the excavated materials including watering & ramming.
2163 AMP 415 volt T.P. main switch confirming to IS 4064(Pt-1& Pt-II) with utilisation category Ac-22
22Supply ,fittintg and placing of 100mmdia Nominal Bore GI pipes having wall thickness 4.5mm electrical resistance welded of medimum class confirming to IS-1239(part-I /2004) with latest amendments ,screwed at both ends as per IS-554 socketed at 1 end and other end protected with plastic threaded protector .The socket confirming IS -1239 (Part-II/1992) with latest amendments in rendom length of 4 to 7 mtrs.Each pipe shouldbear ISI certification and manufacturers name /trade mark.
23Letter writings over display Board including painting with enamelled paint .Including cost of materials as per the direction of the Engineer-in-charge.
24Labour charges for fitting ,fixing of suction ,delivery fitting including M.S Tee set ,NR valve, Switch valve and Air release valve etc minor welding transportation of materials to site etc. including nut, bolt rubber insallation etc complete.
25100mm dia C.I.screw base foot valve (Kirloskar make preferbely ) with ISI mark.
26100mm dia G.I. bend IS No 1239(Part-II/1992)
27100mmdia G.I.flange IS No 6392/1971
28100 mm dia C.I.N.R valve IS No 5312(Part-I) with ISI mark
29100mm dia C.I.sluice valve IS No 14846-2000(Part-I)
30100mm dia G.I. Nipple
31200x200x100mm dia M.S. Tee with 200mm ID & 216mm OD, 400mm long welder with 1 mtr.long 100mm dia M.S. pipe(medium duty) welded with two nos. of 100mm dia M.S. Flange in between the one mtr. long M.S. pipe and another 0.25 mtr. long 100mm dia M.S. (medium duty) pipe fitted horizontally with two nos. of 100mm dia M.S. elbow with water locking arrangement made out of one no. of 100mm dia open flange and one no. of 100mm dia blind flange with hinges, gaskets arrangement to enable inseration of 200mm dia UPVC pipe up to a length of 100mm both sides. The arrangement to be painted with two coats of anti corrosive paint.
32200mm PVC equal Tee (6 Kgf/sqcm)confirming to PL-R PVC-IS 2000F
3350mm dia C.I.A..R Valve IS Mark14845(SI)with 1 mtr long G.I.Short piece with saddle
34100x100x25 mm dia GI Tee for Priming with locking arrengement.
35200mm dia PVC end cap confirming to PL-R PVC-IS 2000 F
36200x100mmPVC/GI. reducing socket
37200 mm PVC Sucket
38100mm dia PVC FTA confirming to PL-R PVC-IS 2000 F
39200mm dia PVC Elbow confirming to PL-R PVC-IS 2000 F
40Cost ofBank cutting, welding, for fitting of G.I.pipe ,G.I.bend, G.I. flange etc.
41Labour charges for 200mm PVC pipe fitting
425KVR capacitor
43Electrical Earthing with 40 mm dia medium duty GI earthing pipe each 3 m long with installation including cost of all materials like GI flange chorcoat, salt etc. as required as per I.E Rule
44Labour charges for electrical installation with supply of electrical petty materials like 4 sq mm flexible wire, Black tape, Fuse wire,Condute pipe etc.
45Construction of Retaining Wall & Barbed wire fencing with RCC Pole, Sand & Metal spreading around the Sub Station, providing Grill gate with lucking arrengement.
46Erection of11 K.V.Linewith all materials required for the same as per the detaild scope, quantity and specification given in the technically sanctioned estimate with 55 mm AAA Condcutor at 60 Mtr. Span etc.
47Commissioning of 11/0.4 KV (1X25 KVA)BIS Level 2 Sub-station with supply of all materials required for the same as per the detailed scope, quantity and specification given in the technically sanctioned estimate.
48Erection 3 phase 4 wire L.T.line run with 3x35+1x25 sq mmwith all materials required for the same as per the detaild scope, quantity and specification given in the technically sanctioned estimate