}

Bids Are Invited For Computersystem ( Thin Client Network – Host Computer ) - Host Computer :The Specifications For A Computer Required To Run A Network Of 40 Work Stations And Allow Multimedia And Video To Run Optimally Is ( At Least ) :• 64 Bi-Bihar

Department Of Education-DOE has published Bids Are Invited For Computersystem ( Thin Client Network – Host Computer ) - Host Computer :The Specifications For A Computer Required To Run A Network Of 40 Work Stations And Allow Multimedia And Video To Run Optimally Is ( At Least ) :• 64 Bi. Submission Date for this Tender is 27-09-2021. Coats and Jackets Tenders in Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

29258588
Bids Are Invited For Computersystem ( Thin Client Network – Host Computer ) - Host Computer :The Specifications For A Computer Required To Run A Network Of 40 Work Stations And Allow Multimedia And Video To Run Optimally Is ( At Least ) :• 64 Bi
Open Tender
Indian
Bihar
27-09-2021

Tender Details

Bids Are Invited For Computersystem ( Thin Client Network – Host Computer ) - Host Computer :The Specifications For A Computer Required To Run A Network Of 40 Work Stations And Allow Multimedia And Video To Run Optimally Is ( At Least ) :• 64 Bit Processor ( 8 Core Preferable ) With A Minimum Speed Of 2.9 Ghz;• Ram 32 Gb;• 4 Gb Dedicated Graphics Card • At Least 1 Tb Hard Drive For Local Storage Of Content;• 4 Internal / External Bays Or Higher• Dvd Rw Or Higher• 4 Pci / Pci Express Slots Or Higher• A Backup Host Computer, To Mirror Course Content At The Local Level And To Include Hardware Redundancy Into The Design ( I.E. If One Computer Fails, The Network Will Continue Operating While It Is Repaired ) ;• 1 Serial And Parallel Port , Computersystem ( Thin Client Network –Terminal Client ) - • 40 X Terminals ( Thin Client ) , Comprising:Quad Core 2.0 Ghz; 2 Gb Ram ( Up To 32Gb ) 10 / 100 / 1000 –T Fast Ethernet ;X1 ( Dvi-Vga-Hdmi ) Adaptor ; Resolution Up To 1920 X 1200 @60 Hz , Vga / Dp / Hdmi Up To2560 X 1600 @60 Hz• 1 X English / Hindi Keyboard ( Same Oem Of Thin Client ) ;• 1 X Mouse ( Same Oem Of Thin Client ) ;• 1 X Energy-Efficient, Thin-Film-Transistor Liquid-Crystal Display ( Tft Lcd ) Monitor With 19.5” Screen 1600 X900 ( Resolution Or Higher ( Same Oem As Of Thin Client ) . ; Monitor Should Have Inbuilt Speaker• 1 X Headphone Set;• Connection To Host Computer Via At Least Cat 6 Cable ( With All Cabling Protected By Fixed Cable Conduits Running Between The Floor And The Walls To The Host Computer ) With Graphics Card Facility To Display Content ( Mostly Video In Nature ) From Host Computer , Computersystem ( Thin Client Network – Operating System Software ) - Software For Thin Client Network• Ms Windows Server 2016 Std. ( National Academic ) Firewall Application ( Integrated Into Operating System ) , Computersystem ( Thin Client Network – Client Access Licence For Os ) - Client Access Licence For 40 Terminals ( Paper License ) , Remote Desktop Service Client Access Licenses - Remote Desktop Service Client Access Licenses ( Rdscal ) For 40 Terminals ( Paper License ) , Computersystem ( Thin Client Network –Microsoft Office Software - • Key Client-Side Software Applications, Including: Suitable Office Software Applications Microsoft Office2016 Suite ( National Academic ) ( Word Processing, Spread Sheet Software, And Presentation Software Etc ) ; Web Browser; Pdf Reader, Flash Player, Video / Audio Player, • Internet Security-Licence Version. ( Paper License ) , Projector - The Projector Must Have Minimum Requirement 1. Display System: Dlp / Lcd / Led2. Brightness: 3800 & Above Ansi Lumens3. Resolution:- Maximum Wxga 4. Contrast Ratio: 15, 000:15. Lamp Life : 5, 000 Hours ( Standard ) , 10, 000 Hours ( Eco ) 6. Aspect Ratio: 4:3 ( Native ) , 16:9 ( Supported ) 7. Allowance For Vga / Hdmi , Digital Photocopier & Mfds - Digital Photocopier & Mfds Must Have Minimum Requirement1. With Separate / Integrated Drum – Paper Size- A42. Paper Capacity – 250 Sheet Tray And 100 Sheet Multi- Bypass Tray3. Memory Standard: 256Mb Minimum4. Speed: 35 Ppm & Above5. Energy Star: 2 Rating6. Zoom Range In Photocopy: 50 To 200% In 1% Increment7. Others Features: Network Print , Scan , Photocopy8. Scan Resolution: 100, 150, 200, 300, 400, 600 Dpi9. Print Colour: Black10. Usb Interface :Usb 2.0 & Above11. Usb : Print , Scan , Mfd Network Printer With Both Side Printing Facility - Network Printer Should Have Following Minimum Standard• Mfd Network Printer:- Print, Scan, Copy • Print: Speed- 28Ppm Or Higher In A4 Size Paper, Resolution - 1200 X 2400 Dpi. Or Higher, Duplex- In Build Duplex Copy-Standard ( 1:1, 1:2 ) Scan: Resolution ( Optical ) - Minimum 1200 X 1200 Dpi Scan To : Pc, Resolution- 300X300 Dpi In Mono Memory-256Mb Or Higher, Interface : High-Speed Usb 2.0, Ethernet 10 / 100 Base Tx And Printer Must Be Connected In Lan Environment.• Paper Handling: Input Capacity And Types 250-Sheet Cassette 1-Sheet Manual Tray, Output Capacity And Type 150-Sheet Face Adf Capacity: 35 Sheet Or Higher.• Os Compatible With All Version Of Windows • Duty Cycle: Monthly 10, 000 Pages Or Higher , Table - Computer Table , Top Size 60Cm ( W ) * 45 Cm ( D ) *75 Cm ( H ) Made , Of 18Mm Thick Pre-Laminated Board With Pvc , Edge Banding. Panel Of 18 Mm Thick Pre-Laminated Board With Single Extrusion Slide Key Board Fitted With 4 Nos. Castor. , Chair - Computer Chairs Without Arms & Castors. Overall Size 52 Cm ( W ) * 54.5 Cm ( D ) * 80.5 Cm ( H ) With Seat Height Of 43 Cm. Seat & Back Injection Moulded In Polypropylene. Tabular Frame In 19 Mm Dia Stainless Steel Tube. , Ups - The Bidder Has To Provide A Minimum 6 Kva Online Iso 9001 Rohs Branded Ups With At Least 1-Hour Backup With 9000 Vah &Above On Full Rated Capacity. Bidder Would Be Responsible For Maintenance / Replacement Of Batteries Whenever Required At His Own Cost To Ensure Requisite Backup. Bidder Has To Ensure That All It Equipment Is Running On Ups In Case Of Power Failure.Input Isolation Transformer Inbuilt. , Genset - 5Kva Single Phase Silent Generator Set Having:1. Type Of Engine : Air Cooled ( Direct Injection ) 2. 2. Grossbhp : 11.5 @ 1500 Rpm3. Type & Class Of Governing : Mechanical, A14.Aspiration: Naturally Aspirated5. Alternator Type : Brushless, Insulation Class H6. Iso -9001: 2000 & Iso 14001 Certification7. B.I.S. Certification Mandatory8. Confirming To Cpcb- Ii Norms9. Fuel To Be Used For Dg Set Must Be Hsd ( High Speed Diesel ) 10. Minimum Output Rating Of 5Kva Operations On Single Phase With Automaticstarting With In One Minute Of Power Failure And A Changeover Switch.11. The Output Voltage Of Dg Set Should Vary With In The Specified Limits Of Plus Or Minus 10%12. The Maximum Permissible Sound Level Shallbe 75 Dba At1 Meter From The Enclosure / Canopy Surface13. Protection Forfrequency / Speed Overload, Low Lube Oil Pressure, High Cylinder Temperature, Low Fuel Level, Exhaust Fan Failure, Charging Alternator / V-Belt Failure Etc. , Computer Lab Site Preparation ( Including Electrical Wiring & Equipment ) - Fixing Of Conducting & Channelling Of Pvc Conduits / Casing Capping On Walls, Completepatch Panel Crimping, I / Ofixing & Termination On Both Ends, Cable Laying Of Electrical Wiring & Cat 6, Testing And Certification Of Utp 40Nodes, 40 Electrical Multi Point, Earthing & Ups Connectivity , Manageableswitch 48 Port Anddata Rack Box - Manageable Switch 48 10 / 100 / 1000Mbps Rj45 Ports And Data Rack Box Ports Must Support 1000Base-Sx And 1000Base-Lx Transceivers.All Copper Ports Must Be Auto-Mdi / Mdix And Auto Negotiable.Non-Blocking Bandwidth With Mac Address Table.Data Rack Box Min. Size Of 2 Ft ( L ) * 1.5 Ft ( W ) * 2 Ft ( H ) Painted With Proper Air Ventilation And Front Side Openable Transparent / Colorglass With Fcc, Ce, Rohs Certification , Lanset Up & Equipment - The Bidder Has To Undertake Lan Set Up Including Cabling For 40 Pcs, Server Andprinters And Has To Provide Required I / O Boxes And Other Allied Accessories , Fire Extinguisher - Mechanical Foam Based Fire Extinguisher ( Stored Pressure ) - Capacity 9 Litre• Capacity : 9 Litre• Discharge Time : Minimum 13 Seconds• Service Pressure : 15 – 19 Bardischarge Throw : ( 2-5 Meter ) , Portable Screen - Portable Screenmust Have Following Minimum Standard• Matt White Surface• Screen To Be Neatly And Easily Retracted Into Its Casing When Not In Use. • To Be Mounted On The Ceiling • Wide Viewing Angle ( 160° ) For Excellent All-Round Visibility • Aspect Ratio: Widescreen ( 4:3 ) Pc Format • Digital Size: 110 Inches , Lab Cleanliness Kit - Standard Quality / Branded , Curtains - Standard Quality / Branded , Charts - At Least 2 Charts Depicting Computer Fundamentals , Wall Clock - Standard Quality / Branded , Ac - 1.5 Tone 5 Star Rating Split Smart Air Conditioner Having Following Minimum Standard• Cooling Capacity: 5050 W & Higher• Copper Pipe Length: 3.5M Or 100% Copper With Ocean Black Protection.• Capacity: 1.5• Anti-Bacterial Filter: Yes• Condensing Coil: Copper• Smart Diagnosis System • Active Energy Control• Remote: Yes Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 3.35 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail