Repair / Maint Of Ceiling Fans, Exhaust Fans And Connected Wiring And Accessories In Tech Area At Af Stn Gwalior Repair / Maint Of Ceiling Fans, Exhaust Fans And Connected Wiring And Accessories In Tech Area At Af Stn Gwalior, GE AF TA GWALIOR-Madhya Pradesh

Military Engineer Services-MES has published Repair / Maint Of Ceiling Fans, Exhaust Fans And Connected Wiring And Accessories In Tech Area At Af Stn Gwalior Repair / Maint Of Ceiling Fans, Exhaust Fans And Connected Wiring And Accessories In Tech Area At Af Stn Gwalior. Submission Date for this Tender is 29-10-2021. Electrification Work Tenders in GE AF TA GWALIOR Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29251254
Corrigendum : Repair / Maint Of Ceiling Fans, Exhaust Fans And Connected Wiring And Accessories In Tech Area At Af Stn Gwalior Repair / Maint Of Ceiling Fans, Exhaust Fans And Connected Wiring And Accessories In Tech Area At Af Stn Gwalior
Open Tender
Indian
Madhya Pradesh
GE AF TA GWALIOR
29-10-2021

Tender Details

Repair / Maint Of Ceiling Fans, Exhaust Fans And Connected Wiring And Accessories In Tech Area At Af Stn Gwalior Repair / Maint Of Ceiling Fans, Exhaust Fans And Connected Wiring And Accessories In Tech Area At Af Stn Gwalior

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Sep-2021 Revision of BOQ and certain amendments BOQ 08-10-2021
2 27-Sep-2021 Date corrigendum and certain other amendments Date 08-10-2021
3 08-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-10-2021
4 21-Oct-2021 CORRIGENDUM II Date 26-10-2021
5 27-Oct-2021 Due Date Extended Admin Corrigendum Date Extend 29-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 41600.0 /-
Tender Value
INR 20.80 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF CEILING FANS, EXHAUST FANS AND CONNECTED WIRING AND ACCESSORIES IN TECH AREA AT AF STN GWALIOR
Sl. No. Item Description
1Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans and air circulating fans etc , of any description, any sweep and from any position / locations (i.e.Technical Area"s OTM Accn/ hangers),sealing cable end, for repairs / servicing / overhauling / painting / numbering etc and hanging / fixing the repaired fans in position after ,dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessaryadjustment and proper alignment of blades,connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii)The rates for above items are deemed to include for transportation of fans to & from workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetalingof motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separatelyunder appropriate item of Sch ‘A’ (v) Writing of fan No. and painting of fans shall be measured and paid for separatelyunder appropriate item of Sch ‘A’/BOQ
2M&L for rewinding with super enamelled copper wire of suitable existing size/gauge including insulating material and varnishing including testing to the satisfaction and all asdirected by Engineer -in- Charge for the following type of fans :-
3(a) Ceiling fan 1200 / 1400 mm sweep any make.
4(b) Exhaustfan 300 mm / 225 mm sweep any make.
5(c) Exhaustfan 375 / 450 mm sweep any make.
6(d) Wall/Cabinfan 450 mm sweep any make.
7(e) Pedestal fan 400 mm sweep any make.
8(f) Air circulating fan of 610 mm sweep any make.
9(g) Flame proof Exhaustfan 300/400 mm sweep any make.
10Supply only the following spare for replacement in fan complete all as specified and directed.
11(a) Bush for the ceiling fan of any make and sweep.
12(b) Ball bearing for ceiling fan/wall fan/pedestal fan/exhaust fan & Cabin fan Make : NBC/SKF/TATS
13(c) Rubber reel.
14(d) Split pin
15(e) Condenser 2.5 MFD Make : Siemens/EPCOS/Usha
16(f) -do- but 3.15 MFD
17(g) -do- but 4 MFD
18(h) Canopy for ceiling fan (set of 02) as per sample. Make : Khaitan/Crompton/Bajaj/Usha
19(m) Regulator resistor type suitable for wall fan Make : Khaitan/Crompton/Usha.
20(n) -do- but for pedestal fan
21(o) MS clips (set of two) as per sample of ceiling fan
22M&L for servicing of in position /after taking down i.e.requried ceiling fan/exhaust fan/cabin fan (any make any size) from any building and opening the same cleaning each part, oiling and greasing including replacement of worn out parts i.e nut, bolt, screw, split pin, rubber real complete and re-fixing in the same position after repair to the entire satisfaction and as directed by Engineer -in- Charge.
23M&L for painting of ceiling fanincluding fan blade of any make of any size with one coat of synthetic enamelled paint over one coat of red oxide primer after scraping old paint and preparing surface for painting and rewriting existing MES number with black paint complete to the entire satisfaction and as directed by Engineer -in- Charge.
24-Ditto- all as per BOQ Sl. No. No 5.00 above but for exhaust fan/Air circulator fan.
25Supply and fixing down rod for ceiling fan made of GI pipe 15mm dia medium grade of length 0.3 to 01 meter or as requiredincluding threading, cutting slotting drilling including nut, bolt clip washer and rubber real.
26S&F wall /pedestal fan blade of any sweep/any size as per sample all as directed by Engineer-in-charge.
27S&F Exhaust fan blade of any sweep/any size as per sample all as directed by Engineer-in-charge.
28S&F Exhaust fan clamp (leg) as per sample (set of 3/4) including rubber packing and clamp for bolt all as directed by Engineer-in-Charge.
29Taking down unserviceable eysers of any size and make from wall bydisconnecting and sealing water line and electrical connection for annual painting/maintenance/ servicing/ overhauling/dismantling ofvarious parts for repair/replacement/painting including carryout brazing to inner tank etc, re-assembling after repair andreplacement of worn parts complete all as specified and directed
30S & F GM non-return valve, 15 mm bore ISI mark complete all as specified and directed.
31S & F lead cum brass alloy pipe for inlet & outlet connection 15 mm bore 450 long including check/end nuts and washer to prevent water leakage all as specified anddirected.
32S & F PVC pipe steel thread armoured forinlet and outlet connection, 15 mm bore 450 long all as specified anddirected.
33S & F vent pipe connection of 15 mm bore, light grade, GI Pipe of required length including necessary fittings complete all as specified and directed.
34S & F heating element of any type, ISI marked (2.0 KW) for 50 ltrs capacity geyser all as specified and directed.
35S & F heating element of any type, ISI marked (1.5 KW) for 25 Ltrs capacity geyser all as specified and directed.
36S & F thermostat for 50/35/25 ltrs capacity geyser of any type and makeas per sample ISI marked all as specified and directed.
37S & F pressure release valve 15 mm dia suitable for 50/35/25 ltrs Geysers of anymake. ISI marked all as specified and directed.
38S & F syphone assembly complete with packing ring and nuts & bolts suitable for 50 ltrs capacity of Geysers of any make including testing against leakage all as specified and directed.
39S & F syphone assembly complete with packing ring and nuts and bolts suitable for 25 ltrs capacity of Geysers of any make including testing against leakage all as specified and directed.
40S & F PVC insulated copper conductor cable multi stranded 3 core 4 Sqmm flexible all as specified and directed.
41S & F fusible plug made of brass having lead alloy fuse suitable for 50/35/25 ltrs capacity Geyser of any make all as specified and directed.
42S & F Inner copper tank for having 50 ltrs capacity geyser of any make all as specified and directed.
43S & F Inner copper tank for 25 ltrs capacity geyser of any make all as specified and directed.
44S & F outer tank for 50 ltrs capacity geyser of any make all as specified and directed.
45S & F outer tank for having 25 ltrs capacity geyser of any make all as specified and directed.
46S&F in replacement 8 Watt LED bollard light one meter long with Opel acrylic diffuser and IP-65 protection including necessary concreat work complete all as specified and directed Make :- HavellsCat Part No BAMBOOBLS8WLED830PSYMTOPC or equivalent in make of CG/Philips
47Supplying & fixing in repair Integral LED Post Top Lantern 50 watt LEDand accessoriesfixing to electric source completeand fixing GIpipe of suitable lengthgrouting in PCC complete all as specified and directed at site. Make: Havells Cat Part No - RUBMAXIPT50WLED830PSYMTOPC /Philips/CG
48M&L for sub main wiring in replacement using two single core PVC insulated,unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
49All as per BOQ Sl No. 30.00 here-in-before butcable of size 6 Sqmm FRLS with one run of PVC(green colour) insulated , unsheathed, stranded copper conductorof size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note :Two run of single core PVC cable with one run ofearth conductor and conduit shall be measured as one unit
50M&L for sub main wiring in replacementusing two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductorof size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note:-Two run of single core PVC cable with one run ofearth conductorshall be measured as one unit
51M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in existing conduitalong-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:-Two run of single core PVC cable with one run of earth conductorshall be measured as one unit. Make :- Havells/KEI/Anchor
52M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 16 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 16 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit. Make :- Havells/KEI/Anchor
53M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.
54M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn inand including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.
55Supply, fixing in repair, connecting & testingof sheet metal enclosures single pole and neutralwith a two pinearth plug and socket complete with one single pole 20 amp MCB complete all as specifiedanddirected. Make :- Legrand/Havells/C&S
56Supply, fixing in repair, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with three pinearth plug and socket complete with one TPN 63 Amp MCBcomplete all as specifiedanddirected. Make :- Legrand/Havells/C&S
57Supply, fixing in repair, connecting & testingof sheet metal enclosures (IP-54 Protection) triple pole and earth with Five pin tempra Plug andsocket (3P+N+E) 125 Amp complete with one TPN 125 Amp MCB complete all as specifiedanddirected. Make :- Legrand/Havells/C&S
58Supply, fixing in repair, connecting & testingof sheet metal enclosures (IP-54 protection) triple pole and earth with Five pin tempra Plug andsocket (3P+N+E) complete with one TPN 40/63 Amp MCB complete all as specifiedanddirected. Make :- Legrand/Havells/C&S
59Supply, fixing in repair, connecting & testing of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps ratingcomplete all as specifiedanddirected.
60All as per BOQ Sl. No. 41.00 here-in-before but distribution board single pole and neutral, 12 way.
61All as per BOQ Sl. No. 41.00 here-in-before but distribution board single pole and neutral, 8 way.
62All as per BOQ Sl. No. 41.00 here-in-before but distribution board single pole and neutral, 4 way
63Supply and fixing in repair factory made epoxy powder coated distribution board VTP & N 4 ways (TPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 160Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specifiedanddirected.
64All as per BOQ Sl. No. 45.00 here-in-before but distribution board VTP & N 8 ways (TPN MCCB DB)for TPN-MCCB upto 160 Amps
65All as per BOQ Sl. No. 45.00 here-in-before but distribution board TP & N 12 ways (TPN MCB DB)for TP-MCB upto 160 Amps
66All as per BOQ Sl. No. 45.00 here-in-before but distribution board TP & N 8 ways (TPN MCB DB) for TP-MCB upto 160 Amps
67S&F MCCB, 3 pole, 250 Amps current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specifiedanddirected.
68All as per BOQ Sl. No. 49.00 here-in-before butMCCB, 3 pole, 160 Amps current rating and ultimate breaking capacity Icu = 16 KA.
69All as per BOQ Sl. No. 49.00 here-in-before butMCCB, 3 pole, 63 Amps current rating and ultimate breaking capacity Icu = 16 KA
70All as per BOQ Sl. No. 49.00 here-in-before but MCCB FP, 100 Ampshaving current rating 16 KA .
71All as per BOQ Sl. No. 49.00 here-in-before but MCB TPN, 63 Amps (`C’ series) having current rating 10 KA .
72All as per BOQ Sl. No. 49.00 here-in-before but MCB TP, 40 Amps (`C’ series) having current rating 10 KA .
73S&F MCCB, 4 pole, 125 Amps,415 voltcurrent rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specifiedanddirected.
74All as per BOQ Sl. No. 55.00 here-in-before but MCB SPN, 40 Amps (`C’ series) having current rating 10 KA
75All as per BOQ Sl. No. 55.00 here-in-before but MCB SPN, 32 Amps (`C’ series) having current rating 10 KA
76All as per BOQ Sl. No. 55.00 here-in-before butMCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA.
77Supply, Laying & connecting cable 06 Sqmm 2 Core 1100 Volts grade, stranded aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cable of following sizesconforming to IS 7098 (Part-I) amended upto datecomplete all as specified and directed for the follwoing sizes:- Note :- (i).Lugs/Glands/saddles of suitable size required for fixing of cables in panels/junction boxes /on walls shall be included in the item rate. (ii)Cable path indicators shall be provided at every 50 mtr intervals of the cable is deemed to included in the item rate.
78(a) 6 Sqmm 4 Core
79(b) 10 Sqmm 4 Core
80(C) 16 Sqmm 4 Core
81Excavation in trenches in soft in loose soil not exceeding 1.5 m deep and not exceeding 1.5 m width and getting out including forming bottom surfaceforlaying cables/pipesall as specified and directed.
82Returning, filling in including spreading, leveling, watering and well ramming in layers n exc25 cm thickafter the cablesare laid, jointed & tested complete all as specified and directed
83Removing of surplus excavated soil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
84Supply and spreading clean, dry, fine river sand for UG electric cable in two layers (8 cm thick before laying the cable & 15 cm thick after laying cable) total 23 cm thick including gentle punning the sand upto 18 cm (total thickness) and consolidated around cable for protection of under ground cable complete all as specified and directed. Note :- Only punned thickness shall be measured for payment
85Supply & Layingprecast PCC cable concrete cable cover LV low voltage type -I flat ISI marked of size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-charge.Make :- Mahatab/Ravi/Duracoat
86Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, byunscrewing from board,outlet box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed rurfaces of walls floors etc all as directed.
87M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing cappingof required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type.PVC Plastic board all asrequired as specified and directed for the following :-
88(a) One light/ Fan point controlled by one way switch.
89(b )One 5 Amps switch socket combination on independent board.
90(c) One 5 Amps socket on same board with other switches.
91All as per BOQ Sl. No. 66.00 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socketpoint as directed.
92S&F switch piano flush type single pole one way 5 Amps 230 V.
93S&F switch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose,
94All as per BOQ Sl. No. 69.00 above but 5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.) .
95S&F socket out let 3 pin, 5 Amps, 230 Volt multipurpose flush piano type. .
96S&F in repairs fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
97S&F in repairs lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge
98Supply& Fixing in repairs LED Batten fittings 20 Wattcomplete with round blocketc,incl PVC gutties and flexible wire and connecting to ceiling rose complete . Model Wipro Garnet 20W , D532065of Wipro or Equivalent model of Philips/Havells
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail