Spl Repairs To Certain Md Accn Of Mes Colony At Od Fort Cantt Allahabad. Spl Repairs To Certain Md Accn Of Mes Colony At Od Fort Cantt Allahabad., Allahabad-Uttar Pradesh

Military Engineer Services-MES has published Spl Repairs To Certain Md Accn Of Mes Colony At Od Fort Cantt Allahabad. Spl Repairs To Certain Md Accn Of Mes Colony At Od Fort Cantt Allahabad.. Submission Date for this Tender is 04-10-2021. Building Work Tenders in Allahabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29251169
Corrigendum : Spl Repairs To Certain Md Accn Of Mes Colony At Od Fort Cantt Allahabad. Spl Repairs To Certain Md Accn Of Mes Colony At Od Fort Cantt Allahabad.
Open Tender
Indian
Uttar Pradesh
Allahabad
04-10-2021

Tender Details

Spl Repairs To Certain Md Accn Of Mes Colony At Od Fort Cantt Allahabad. Spl Repairs To Certain Md Accn Of Mes Colony At Od Fort Cantt Allahabad.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Sep-2021 Amendment in PS Other 04-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 78000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPL REPAIRS TO CERTAIN MD ACCN OF MES COLONY AT OD FORT CANTT ALLAHABAD.
Sl. No. Item Description
1Demolition of plain cement oncrete (un reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
2Cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate), 40mm thick, as in floor finishes as in sunken floors, finished even and smooth without using extra cement but using water proofing compound, complete all as specified and directed. NOTE:- The quantity of water proofing compound shall be measured and paid separately under respective items of this Schedule.
3Rendering 15mm thick, on fair faces of brick work or concrete surfaces of sunken floors, in CM 1:3 mixed with water proofing compound, finished surface even and smooth without using extra cement, complete all as specified and directed. NOTE:- The quantity of water proofing compound shall be measured and paid separately under respective items of this Schedule.
4Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat, complete all as specified and directed.
5Cement concrete type E-2, 1:5:10 (40mm graded stone aggregate), in foundations, filling and mass concrete, complete all as specified and directed.
6Low density polyethylene (LDPE) pipes of pressure rating 6 kgf per sq. cm, 50mm bore of pipe, complete all as specified and directed.
7Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
8Non - skid Ceramic coloured tiles 7 to 8 mm thick, size 300mm x 300mm, in floors etc,. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including provision of screed bed 15mm thick in CM 1:6, complete all as specified and directed.
9Joint free Non - skid Ceramic coloured tiles 7 to 8 mm thick, size 400mm x 400mm, in floors etc,. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including provision of screed bed 15mm thick in CM 1:6, complete all as specified and directed.
10Glazed coloured ceramic tiles in 450mm x 300mm x 7mm / 350mm x 250mm x 7mm thick, in vertical surfaces such as skirting, dados, risers to steps, etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile laid over and including provision of backing coat of 10mm thick in CM 1:4, complete all as specified and directed.
11Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc.,laid, bedded and pointed in cement mortar, complete all as specified and directed.
12Machine cut kota stone slab flooring 20-25mm thick, as in floors, over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over and including provision of screed bed 20mm thick in CM 1:4, complete all as specified and directed.
13Machine cut kota stone slab flooring 18-20mm thick as in vertical surfaces such as skirting, dado, risers of steps etc. over cement mortar backing coat laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over and including provision of backing coat 10mm thick in CM 1:4, complete all as specified and directed.
14Dismantling of Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer), laid, bedded and pointed in cement mortar, complete all as specified and directed.
15Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and directed.
16Plain Cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate), as in roof padding, levelling course, benching etc., finished even and rough to receive ceemnt mortar screed bed, complete all as specified and directed.
17Screed bed or bedding layer of mortar 10 mm thickfor laying floor finishes, in CM 1:3 over roof slab duly mxied with water proofing compound, complete all as specified and directed. NOTE:- The quantity of water proofing compound shall be measured and paid separately under respective items of this Schedule.
18Providing water proofing treatment over cleaned roof surface comprising of following, including testing complete all as specified and directed. [a]Cleaning of roof surface by steel wire brushes, brooming down and removed all loose dirt and cleaned surface and applying bituminous primer @ 0.3 kg per sq.m conforming to IS : 3384-1986 uniformly on the entire surface [b]Apply tack coat of hot blown bitumen 85/25 @ 1.2 kg per sq.m comfomiing to IS : 702-1998 on entire surface of roof for fixing of water proofing membrane. [c] Over hot bitumen, Laying polymeric waterproofing membrane consisting of 90 to 100 micron thick central core of HMHDPE film with standard weight not less than 3 kg per sq.m over entire area with overlaps 100 mm each side and joints sealed , complete all as specified and directed. [d]Applying one coat of bituminous aluminium paint over the APP membrane @ 0.1 litre per sq.m of roof surface
19Excavating in post holes (or similar holes) each not exceeding0.5 cu. m, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
20Cement concrete type B-2, 1:5:10 (40mm graded stone aggregate), in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars boundary pillars and posts (including caps and bases), complete all as specified and directed.
21Rolled mild steel sections conforming to Fe 410-W (Gde E-250) quality "A", as in Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections, complete all as specified and directed.
22Rolled mild steel sections conforming to Fe 410-W (Gde E-250) quality "A", as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), complete all as specified and directed.
23Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed.
24Framed work such as grills, gratings, etc..with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
25Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheetMangolorepattern, 0.50mm thick of an colour having tensile strength of 550 MPa as in roof covering / cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed. MAKE:- TATA / JSW / SPECTRUM NOTE:- Sheet shall be fixed by manufacturer in scattered locations and shall be cut in to required length / shape as in chajja projection, balcony projection and as the quoted rate shall deemed to be inclusive with and including provision of suitable scaffolding / hanging devices for fixing the same at any height upto and including double storey building
26Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 MPa as in ridges, hips, valley gutters, cladding etc., fixed with self tapping screws as specified, complete all as specified and directed.
27Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
28Brickwork with flyash bricks, old size straight or curved on plan exceeding 6m mean radius, in half brick thick walls built in CM 1:4, complete all as specified and directed.
29Taking down cement plaster on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish off the premises, complete all as specified and directed.
30Rendering 15mm thick, on fair faces of brick work or concrete surfaces of walls, in CM 1:4 mixed with water proofing liquid, finished surface even and smooth without using extra cement, complete all as specified and directed. NOTE:- The quantity of water proofing liquid shall be measured and paid separately under respective items of this Schedule.
31Preparation of new plastered surfaces walls and applying two coat of cement base paint over a coat of 1mm thick wall care putty, complete all as specifed and directed.
32Rendering 10mm thick, on fair faces of brick work or concrete surfaces of walls, in CM 1:6, finished fair and even, complete all as specified and directed.
33Preparation of newly plastered surfaces of walls and applying three coat of white wash, complete all as specified and directed.
34Preparation of newly plastered surfaces of walls and applying a coat of Clearcolle on plastered and other surfaces as a preparatory to distempering and applying two coat of acrylic emulsion paint, complete all as specified and directed.
35Rendering 5mm thick, on fair faces of brick work or concrete surfaces of ceilings, in CM 1:4, finished even and smooth without using extra cement, complete all as specified and directed.
36Preparation of newly plastered surfaces of Ceiling and applying two coat of white wash, complete all as specified and directed.
37Supply only integral water proofing compound, ISI marked, complete all as specified and directed.. NOTE:- The integral water proofing compound shall be used all as per manufacturers instructions only.
38Supply only integral water proofing liquid, ISI marked, complete all as specified and directed.. NOTE:- The integral water proofing liquid shall be used all as per manufacturers instructions only.
39Repair to RCC chajjas and projections of any type, any size, any shape and situated at any height (normally upto and including double storey height) using CM 1:3 and thickness of mortar not exceeding 15mm with and including provision of suitable scaffolding / hanging devices, including finshing the surface even and smooth, edges rounded and chamferred, including making drip course on outer edge of projection, complete all as specified and directed.
40Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including cutting of reinforcement to facilitate demolition, complete all as specified and directed. NOTE:- The reinforcement obtained out of demolition shall be deposited in the AGE B/R storeyard and shall be taken into charge by the department duly entering into the salvage register.
41Cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate), as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
42Taking up or down 15mm bore, steel tubing and connections, , including cleaning for refixing or removal to store, complete all as specified and directed.
43Taking up or down 20mm bore, steel tubing and connections, , including cleaning for refixing or removal to store, complete all as specified and directed.
44GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 15mm bore of pipe, complete all as specified and directed.
45GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 20mm bore of pipe, complete all as specified and directed. NOTE:- (for Sl. No. 44 & 45 here-in-before): The quoted shall deemed to be inclusive for making holes RCC slabs and making good with PCC 1:2:4 type B1 (20mm graded stone aggregate) to match with the existing surfaces
46Refixing old 15 mm dia steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) including necessary cutting and making of new threads for fixing of new fittings including provision, such as elbows, tees, sockets, union, reducer, etc.complete all as specified and directed.
47Refixing old 20 mm dia steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) including necessary cutting and making of new threads for fixing of new fittings including provision, such as elbows, tees, sockets, union, reducer, etc.complete all as specified and directed.
48Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), 500 litre capacity (ISI marked), double layered, hoisted and fixed in position including tank nipple as intlet, outlet and wash out connections, including provision of 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gram, including Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed.
49Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, 20mm bore, complete all as specified and directed.
50Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), including provision of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, CI trap 100mm bore of pipe, fixed in repair, complete all as specified and directed.
51Cast iron "P" trap or "S" trap, 100mm bore, complete all as specified and directed.
52Cast iron 100mm size connection socket to fit WC out-let, complete all as specified and directed.
53PVC low level flushing cistern "white" with inlet, 10 litre capacity, float valve including bracket with 32mm dia PVC pipe 600mm long, fixed in repair, complete all as specified and directed.
54Vitreous China wash basin, white, flat back, size 580mm x 450mm fixed on cantilever brackets of MS of 32mm dia, brass waste coupling, fixed in repair,complete all as specified and directed.
55Flush pipe of polyethylene of low or high density or PVC. 32mm dia, for low level cistern,complete all as specified and directed.
56PVC connections 15mm size with PTMT nuts of length 450mm,complete all as specified and directed.
57Kitchen sink without drainage board made of stainless steel 1 mm thick with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets of mild steel angle 35 x 35 x 5 mm, 32mm dia brass waste coupling, 32mm dia PVC waste pipe (rigid quality) and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, fixed in repair, complete all as specified and directed.
58Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed but fancy type, chromium plated with long shank and cup (concealed type), 15 mm bore, fixed in repair,complete all as specified and directed.
59Bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, chromium plated, screwed down, screwed for iron pipe or for brass ferrule, long body for 15mm bore, fixed in repair, complete all as specified and directed.
60Bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule, for 15mm bore, fixed in repair, complete all as specified and directed.
61Angle valve cast of screwed down, high pressure, with crutch or butterfly handle, 15mm bore, screwed for iron pipe or for unions, fixed in repair, complete all as specified and directed. MAKE:- Cat No. 0047 of L&K or techno-commercially equivalent model in any one of the make as specified here-in-after and as approved by GE
62Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore, fancy type, fixed in repair, complete all as specified and directed.
63UPVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, fixed to walls including taking down existing pipes, complete all as specified and directed.
64UPVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, laid in trenches, complete all as specified and directed.
65UPVC (SWR) bends of any radius and 75mm bore, fixed to pipes over walls and making good using CM 1:4 or PCC 1:2:4 type B0 (12.5mm graded stone aggregate) as applicable,complete all as specified and directed.
66UPVC (SWR) bends of any radius and 75mm bore, with oval access door and fixed to pipes with rubber solvent,complete all as specified and directed.
67UPVC (SWR) branch piece, single (single Y) equal or unequal, 75mm bore, with oval access door and fixed to pipes with rubber solvent,complete all as specified and directed.
68UPVC (SWR) junction double, (double T), equal or unequal, 75mm bore, with oval access door and fixed to pipes with rubber solvent,complete all as specified and directed.
69UPVC (SWR) floor trap, plain, 75mm bore and fixed to pipes with rubber solvent,complete all as specified and directed.
70UPVC (SWR) vent cowl, 110mm bore, and fixed to pipes with rubber solvent,complete all as specified and directed.
71UPVC (SWR) 110 mm bore pipes single socketed ends, in any length with rubber ring joints, laid in trenches, complete all as specified and directed.
72UPVC (SWR) bends of any radius and 110mm bore, fixed to pipes over walls and making good using CM 1:4 or PCC 1:2:4 type B0 (12.5mm graded stone aggregate) as applicable,complete all as specified and directed.
73UPVC (SWR) junction double, (double T), equal or unequal, 110mm bore, with oval access door and fixed to pipes with rubber solvent,complete all as specified and directed.
74Salt-glazed stoneware gully traps, square or round mouthed, tvpe "P", size 150mm x 150mm, including setting and jointing to drains with cement mortar 1:1, complete all as specified and directed.
75UPVC (SWR) reducers, 110mm / 75mm and fixed to pipes with rubber solvent, fixed in repairs,complete all as specified and directed.
76Brass, Chromium plated shower rose 65 to 90 mm size with swivel joints fixed to 15mm bore pipe, fixed in repair, complete all as specified & as directed.
77Supply only 32mm dia waste pipe of polythelene flexible for wash hand basin or urinals, complete all as specified & as directed.
78Mild steel (miscellaneous works) as in Bands, straps,supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
79Grating, chromium plated, 100mm dia, fixed with solvent cement amd making good the distubed surfaces to match with the existing, fixed in repairs,, complete all as specified & as directed.
80Bevelled edge mirror of 600mm x 450mm of oval shape glass, mounted on 6mm thick AC building board or commercial plywood with PVC frame and fixed to wooden plugs with chromium plated brass screws and cup washers, fixed in repair, complete all as specified and directed.
81Taking down chowkats or frames not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
82Taking down chowkats or frames exceeding 1.5sq.m but not exceeding 4sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
83Taking down shutter of any description not exceeding 1 sq.meach and removing from site, complete all as specified and directed.
84Taking down shutter of any description exceeding 1 sq.m but not exceeding 2 sq.meach and removing from site, complete all as specified and directed.
85Second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified and directed.
86Glazed and skeleton shutters, 35mm thick, second class hardwood, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers ,complete all as specified in SSR Pt- I, section 8, clause 8.24(a), complete all as specified and direcetd.
87Flush shutters 32 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides,complete all as specified and directed.
88Flush shutters 25 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides,complete all as specified and directed.
89Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and directed. MAKE:- SINTEX / RAJSHREE PLASTIC WOOD FOREX, INDORE
90Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed. MAKE:- SINTEX / RAJSHREE PLASTIC WOOD FOREX, INDORE
91Steel window factory made with side hung shutter including box type hinges with steel handle, steel peg stay, complete with glazing bars, dovetailed or welded joints, with and including painting two coat of synthetic enamel paint over a shop coat of red-oxide primer after preparation of steel surfaces, complete all as specified and directed. NOTE:- The quoted rate shall deemed to be inclusive of the provision of one coat of red-oxide primer before enamel painting, if the time lapsed between shop coat provided and actual incorporation of steel windows at site is more than six months.Nothing extra shall be payable on this account and decisioin of GE shall be final and binding.
92Steel window factory made with side hung shutter including box type hinges with steel handle, steel peg stay, complete with out glazing bars, dovetailed or welded joints, with and including painting two coat of synthetic enamel paint over a shop coat of red-oxide primer after preparation of steel surfaces, complete all as specified and directed. NOTE:- The quoted rate shall deemed to be inclusive of the provision of one coat of red-oxide primer before enamel painting, if the time lapsed between shop coat provided and actual incorporation of steel windows at site is more than six months.Nothing extra shall be payable on this account and decisioin of GE shall be final and binding.
93Taking out existing steel window / ventilator, any size and repairing the defective portion including provision of necessary fitting for alignment of steel window and refixing of the same in existing position including making good of disturbed surfaces to match with the existing, complete all as specified and directed.
94Aluminium anodised alloy barrel tower bolt of extruded section, 150mm long, fixed with screws complete all as specified and directed.
95Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed,complete all as specified and direcetd.
96Butt hinges, 100 mm long, medium weight, cold rolled mild steel, complete all as specified and directed.
97Aluminium handles, cast type, anodised, 150mm size, complete all as specified and directed.
98Aluminium anodised hasp and staple, 100mm size,complete all as specified and directed.
99Mild steel, ordinary rat tail rod pattern springs including roller and roller plate, 300mm long,complete all as specified and directed.
100Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specifed and direcetd.
101Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, fixed in repair, complete all as specifed and direcetd.
102MS tubing of 25mm dia with PVC coating for curtain rod fancy type including fancy type PVC brackets (wall to wall or flush to wall) for securing to curtain rod, fixed in repair, complete all as specified and directed.
103Preparation of new steel and iron based surfaces exceeding 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
104Preparation of new wood and wood based surfaces exceeding 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
105Hacking out old broken glass (any thickness, size, quality or description) from metalframe, complete all as specified and directed.
106Sheet glass, 3 mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane,complete all as specified and directed.
107Sheet glass ordinary quality 4 mm thick frosted on one side and glazing with oil putty or wooden beads in a square not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
108Preparation of old surface of ceiling and applying two coat of white wash, complete all as specified and directed.
109Preparation of old plastered surfaces of walls and applying one coat of acrylic emulsion paint, complete all as specified and directed.
110Preparation of old plastered surfaces of walls with sand or emery paper and applying two coat of cement base paint, complete all as specifed and directed.
111Preparation of old wood and wood based surfaces exceeding 10 cm width or girth using sand or emery paper and applying one coat of synthetic enamel paint, complete all as specified and directed.
112Preparation of old steel and iron based surfaces exceeding 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
113Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
114Taking down switches, distribution boards and old cut-outs etc., of any type and carefully along with the existing boards and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
115Taking down carefully sub-main wiring of any type and any numbers including earthwire surface type / concealed type and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
116Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FR copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.60mm thick factory made pressed steel terminal box of required size, duly painted both inside and outside with two coat of black bituminous paint over a coat of red oxide primer, duly covered with 3.0mm thick prelaminated sheet cover of colour as approved andduly concealed in walls for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FR copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light point controlled by one 5 Amp one-way switch, complete all as specified and directed. NOTE:- (i)The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii)Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
117All as per Sl. Item No. 116.00 here-in-before but for 5-pin 5Amp socket outlet point on independent board
118All as per Sl. Item No. 116.00 here-in-before but for one 5-pin socket oiutlet 5 Amp on same board alongwith other switches
119All as per Sl. Item No. 116.00 here-in-before but for one buzzer point controlled by one 5Amp switch
120All as per Sl. Item No. 116.00 here-in-before but for ligth point controlled by two 5Amp two-way switches
121Point wiring complete with 2.50 sq.mm PVC insulated unsheathed multi-stranded FR copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, including provision of 1.60mm thick factory made pressed steel terminal box of required size, duly painted both inside and outside with two coat of black bituminous paint over a coat of red oxide primer, duly covered with 3.0mm thick prelaminated sheet cover of colour as approved andduly concealed in walls for housing switches, sockets, regulators etc., including 2.50 sq.mm PVC insulated unsheathed multi-stranded FR copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one 6-pin, 15/16 Amp socket outlet, complete all as specified and directed. NOTE:- (i)The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii)Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
122Switch piano, flush type single pole, one-way 5 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
123Switch piano, flush type single pole, two-way 5 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
124Socket outlet 2 in 1, 3 pin, 5A, flush type, ISI marked, complete all as specified and directed.
125Switch piano, flush type single pole, one-way 15/16 Amp, white or ivory colour, ISI marked, complete all as specified and directed.
126Socket outlet 2 in 1, 6 pin, 15/16 Amp, flush type, ISI marked, complete all as specified and directed.
127Lamp holder, PVC polycarbonate body with back plate suitable for batten fittings, complete all as specified and directed.
128Ceiling rose three terminal PVC / polycarbonate insulated body, surface bakelite type AC 50 Hz 230V, complete all as specified and directed.
129Bell push, 5Amp, piano type, single pole one way, ISI marked, complete all as specified and directed.
130Electric bell, ding-dong type, 230V AC 50Hz, single pole,, complete all as specified and directed.
131Stepped (rotary) type electronic fan regulator (suitable for 1200mm / 1400mm sweep ceiling fan) flush type duly fixed on the existing phenolic laminated sheet etc. as required, 240V, humming free, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
132MCB DB, SPN, double door, vertical type, epoxy powder coated, factory made 8-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, fixed in repairs, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
133MCB SPN 6 - 32 Amp, 240 Volt, "C" curve, 10KA breaking capacity, complete all as specified and directed.
134MCB SP 6 - 32 Amp, 240 Volt, "B" curve, 10KA breaking capacity, complete all as specified and directed.
135LED bulk head light fitting, 10W, 600lumen, enclosed in polycarbonate body, weather proof, fixture with co-extruded polycarbonate body, environmental friendly, energy efficient, complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. ENDURA Model No. WT202W LED6S CW PSU S1 PC of Philips or techno-commercially equivalent model in Havells / CG
136LED mirror light fitting, 1x9W, 6000K decorative indirect up-down light fitting for mirror and wall light application with extruded polycarbonate environmental friendly energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. IVORY Model No. LHESABP7IN1W009 of Havells or techno-commercially equivalent model in Philips / CG
137LED wall mounted tube light fitting, 1x18W, LED 6000K, decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. LHEXBHP7IN1W018 of Havells or techno-commercially equivalent model in Philips / CG
138LED decorative wall light fitting nade up of polycarbonate suitable for 15W TU retrofit CFL (B-22 base), polycarbonate body weather proof, LED light fitting envitronmental friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Cat No. CITY 4, LHFODFE1TC1W015 of Havells or techno-commercially equivalent model in Philips / CG
139Road lighting luminaire 36W with unique peanut optics to ensure uniform distribution, hgiher spacing between poles and maintenance free system for city roads and streets, 50% energy saving, IP 66 protection PC and FG cover, high impact resistance complete including LED lamps and all accessories including bracket made out of 25mm bore light grade GI tubing of 1.20metre length bent to shape required and fixed to existing pole or building by means of two Nos MS FI 40mmx6mm clamps with suitable size bolt, nuts and washers and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from fittinge to existing junction boxr of required length, complete all as specified and directed. MAKE:- Cat No. BRP409 LED CW 036 MR FG S1 PSU GR of Philips or techno-commercially equivalent model in Havells / Bajaj / CG
140Sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of rigid PVC conduit 25mm dia including conduit accessories and connecting terminal ends to DB"s including providing 1 run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC conduit and conduit accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
141Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mmthick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe "medium grade", watering pipe 20mm dia GI pipe "light grade", GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) If earth resistance is not found satisfactory, till satisfactory test result comes, the same shall be redone by the contractor without any extra cost to department.
142Taking down existing ceiling fan / exhaust fan, any sweep, by disconnecting carefully all electric connection and refixing the same after necessary repair work as required (such as cleaning all the serviceable parts thoroughly, reassembling the fan after testing for proper functioning), with and including provision of electrical wire 3-core 23/0.0076 copper conductor, including provison of one coat of synthetic enamel paint of tint same as that of exisitng, including wiring of MES No on fan motor, complete all as specirfied and directed. NOTE :The quoted shall deemed to be inclusive of every minor items i.e., nut, bolts, screws, lugs etc., which are faily required for the smooth functioning of fans.
143Taking down existing geyser of any capacity, any type after disconnectingall electric and water supply connection, removing the geyser to E&M store yard for opening and dismantling the complete geyser, cleaning all the serviceable parts thoroughly, including descaling the geyser completely, replacing the defective / wornout parts / materials, reassembling the geyser after testing for proper functioning, including transporting to original location and re-fixing the same in position, reconnecting the geyser with electric and water supply line and testing, complete all as specified and directed.. NOTE :The quoted shall deemed to be inclusive of every minor items i.e., nut, bolts, screws, lugs etc., which are faily required for the smooth functioning of geyser.
144Two pin, earth plug and socket with 1 MCB single pole 20 to 32 Amps, "C" series 10 KA in sheet metal enclosure and connecting, fixed in repair, complete all as specified and directed.
145Supplying, installation, testing and commissioning of factory made indoor type LT panel board 415 Volt, 4-wire, AC 50 Hz, of size 1000mm x 1000mm x 500mm, made out of 2mm thick CRCA sheet, weather and vermin proof powder coating finish both interior and exterior side, for indoor wall mouting with having degree of protection as per IP-65 with locking arrangements, two earth terminal suitable cable gland for incoming and outgoing with suitable size of lugs, complete all as specified and directed with and including provision of the following :- (a) Copper insulated busbar high conductivity 200Amp rated 3-phase including neutral bus bar - 01 No (set of four strip) (b) MCCB, four pole, 160 Amp, 415 Volt, 25kA breaking capacity, 50 Hz with thermal magnetic release - 01 No (incoming) (c) MCCB, two pole, 40 Amp, 415 Volt, 25kA breaking capacity, 50 Hz with thermal magnetic release - 08 Nos (outgoing) (d) MCB SPN 20Amp 10kA "B" curve - 01 No (e) Fixing and connecting existing electric energy meter - 08 Nos including provision of name slip holder on each compartment for identification of accommodation - 08 Nos (f) Indicating light LED type (RYB) set of three - 01 No (g) Ammeter (0-500Amp) three phase digital type and inbuilt selector switch including CTs and Voltmeter 0-500Volt - 01 set each (h) Earthing terminal - 02 Nos