Bids Are Invited For Oxygenmanifold4+4 , Oxygen Emergency Point , Oxygen Control Panel , Copper Pipe , Copper Pipe 15 , Copper Pipe 28 , Copper Pipe 42 , Gas Terminal Unit , Isolation Valves Assembly , Medical Gas Monitoring Alarm , Bpc Flowmete-Punjab

Department Of Health And Family Welfare -DOHAFW has published Bids Are Invited For Oxygenmanifold4+4 , Oxygen Emergency Point , Oxygen Control Panel , Copper Pipe , Copper Pipe 15 , Copper Pipe 28 , Copper Pipe 42 , Gas Terminal Unit , Isolation Valves Assembly , Medical Gas Monitoring Alarm , Bpc Flowmete. Submission Date for this Tender is 06-10-2021. Bottles Tenders in Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

29236868
Corrigendum : Bids Are Invited For Oxygenmanifold4+4 , Oxygen Emergency Point , Oxygen Control Panel , Copper Pipe , Copper Pipe 15 , Copper Pipe 28 , Copper Pipe 42 , Gas Terminal Unit , Isolation Valves Assembly , Medical Gas Monitoring Alarm , Bpc Flowmete
Open Tender
Indian
Punjab
06-10-2021

Tender Details

Bids Are Invited For Oxygenmanifold4+4 , Oxygen Emergency Point , Oxygen Control Panel , Copper Pipe , Copper Pipe 15 , Copper Pipe 28 , Copper Pipe 42 , Gas Terminal Unit , Isolation Valves Assembly , Medical Gas Monitoring Alarm , Bpc Flowmeter With Humdifier Bottle , Isolation Valve , Isolation Valve 28 , Isolation Valve 42 , Automatic Dual Supply Change Over Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Sep-2021 01-10-2021
2 01-Oct-2021 06-10-2021

Key Value

Document Fees
Refer document
EMD
INR 33700.0 /-
Tender Value
INR 16.85 Lakhs /-

BOQ Items

Sl. No. Item TitleItem Description
1OxygenManifold4+4The oxygen manifold would be of above size of bulk oxygen cylinders. It is suitable to with stand a pressure of 2400 PSI.The main frame are made out of 50 X 50 X 6 mm angle iron and bottom frame of 20 X 20 mm ms square are install in such a way that the cylinders must be stage for use in upright position and are not fell down under any circumstances.The gases passed through inter-connecting tail pipes duly fitted with suitable bull nose and nut adopter for cylinder valve and tube size is 10 mm OD Copper tube duly annealed having wall thickness 1.5 mm in spiral shape and the other end of the tail pipe are fixed with non-return valve.The non return valve are fixed in brass block of size 25 mm square vertically which are fitted with high pressure copper tube of size 15mm OD having wall thickness 1.5 mm. Both the arms of manifold further fixed in automatic control panel.All the joints of copper tube, brass block, and inter connecting tubes are welded with silver brazing. Pressure release safety valve also provided. The manifold is fabricated in such a way to give distribution flow of 1500 ltrs per minute. The manifold would be degreased and purged with inert gas before commissioning.The manifold would be enamel painted as per color code. All above work would be done strictly as per specification and entire satisfaction of engineer in-charge.
2Oxygen Emergency PointOxygen Emergency Point CE Marked : SPECIFICATION:- In case of emergency, the supply of medical oxygen is restored immediately with this system. The emergency system would be consists of 1 no.Cylinders - configuration This would be suitable withstand a pressure of 2400psi. This wouldbe inter connected with high pressure, high flow, double stage control regulator duly fitted with cylinder contents as well as line pressure gauges of 50mm dial size. Pressure release Safety valve are also be provided in this system, so that it would release the pressure beyond 70psi. The outlet point of pressure regulator would be connected with emergency point of oxygen pipeline with the help of inter-connecting adopters.
3Oxygen Control PanelOXYGEN CONTROL PANEL CE Marked SEMI AUTOMATIC SPECIFICATION FEATURES • Electric audio- visual indicators for each bank status. • Electrically audio-visual indicators at the time of changeover. • Impact and weather resistance colored cover. • Independent gauges and indicators. • Automatic change over from on line bank to reserve bank and vise versa. • In built low-pressure audiovisual alarm.
4Copper PipeCopper tube of soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition. 12mm
5Copper Pipe 1515mm
6Copper Pipe 2828 mm
7Copper Pipe 4242mm
8GAS TERMINAL UNITGAS TERMINAL UNIT :Terminal Units (Gas Outlets) with adaptors/probe for oxygen, compressed air and vacuum: Matching adaptors to the gas outlet mentioned above i.e. adaptor for oxygen, air and vacuum. The terminal units would have following features. a. It would be front insertion type. b. Terminal unit would have mechanism with check valve. C. Allow single hand operation. D. On first insertion of probe the probe shall sit in a standby position. At the stage there shall be no gas flow. E. Only on pressing the probe second time, the gas supply would start. F. They would close automatically when connected apparatus is removed. G.For allowing on line maintenance the terminal unit would be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened. H. The outlet would be non interchangeable for specific gas and it would accept only correct medical gas adopter/Probe. I. It would be color coded as per HTM 2022 J. The design of this outlet would be compatible toinstalled vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. K. It would only supply with correct probe/ adopter. Oxygen
9ISOLATION VALVES ASSEMBLYISOLATION VALVES ASSEMBLY: CE MARKED - ISO 9001-2008 SPECIFICATION: To control the pressure as well as for maintenance quarter turn open at 90-degree ball type valves would be provided. These valves would be of nickel-plated brass body having PTFE seat and inner outer seals. These valves would have stainless steel ball of specific ID clearance so that line pressure would not drop. For installation only PTFE gaskets would be used in between nuts and valve to prevent leakage.All the nuts for fixing the ball valve would be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies would be on approachable height for easily operation. And enclosed in powder quotedvisible box. As per Bid Specification 1 Gases
10MEDICAL GAS MONITORING ALARMMEDICAL GAS MONITORING ALARM : CE Marked (AREA-WISE/MAIN) SPECIFICATION:- A Gas failure Alarm would be provided which must be capable of monitoring all the Medical Gases. This alarm would be of ELECTOMECHANCIAL TECHNOLOGY,To detect the fault, pressure sensors, which detect deviation from the normal operating limits, would be installed. Each pressure Gas would displayed by colored LEGEND"S to show normal and ‘Low’ conditions.At the time of receiving the fault the normal window/ indicator stop indication and other window would blink and it also gives audio alarm. The alarm panel would have a test facility to check the internal circuits, mute facility for making silent the buzzer, acknowledgement facility for receiving the fault and reset facility for resetting the alarm after rectifying the fault.as per Bid specifications1 Gases
11BPC FLOWMETER WITH HUMDIFIER BOTTLEBPC FLOWMETER WITH HUMDIFIER BOTTLE, CE MARKED- would be BPC single type Pipeline Flow Meter unit duly fitted with the fine adjustment valve. It would be backpressure compensated to bear and control the Oxygen Pressure approx. 60psi. Flow meter unit would be consisting of double wall rotta-meter has range of flow 0 to 13 ltrs. per minute with fine adjustment valve. The rotta meter and humidifier bottle would be made of clear, impact resistance polycarbonate (duly graduated). This unit would be have attachment to fit humidifier bottle of capacity 100 Ml. consist of clear, impact resistance polycarbonate jar. This would also have Reciprocating on top for flow meter/plastic cap having nozzles for outlet tubes and the inlet tube end would be multi function combination bubblier/ nebulizer to add the humidity and create an aerosol in Medical Gas min marks would be on jar. This unit would be supplied with PVC Clear green tube of 1.5mtrs. Long duly fitted with disposable Oxygen mask
12ISOLATION VALVEISOLATION VALVE : P & F of issolation ball valve assemblies of differnt size made out of brass dully nickel plated havinf full flow of gase and quarter turn open with SS ball and taflon seat. 15mm
13Isolation valve 2828 MM
14Isolation valve 4242 MM
15Automatic dual supply change overSITC of automatic dual supply & one output oxygen gas change over, made out of MS sheet dully powder coated, having independent pressure gauge showing incoming and outgoing gases status, with digital presuure reading and micro processed based presuure sensors, along with twin shuttle valve for auot changeover of gas along with 3 no. isolation valve suitable for 1000-1500 LPM of oxygen flow @ 4 bar max. In case of variation in supply/delivery pressure thedigital reading numbers become RED and in case of normal the same numbers remain GREEN. At the time RED three should be buzzer. Two no oxygen regulator should also be provided. The unit is capable for uninterrupted oxygen supply.