Maintenance And Replacement Of Sub Mains, Dbs, Unserviceable Electric Meters And Certain Other Misc Maintenance And Replacement Of Sub Mains, Dbs, Unserviceable Electric Meters And Certain Other Misc E / M Items At Af Stn Bhuj, GE (AF) BHUJ-Gujarat

Military Engineer Services-MES has published Maintenance And Replacement Of Sub Mains, Dbs, Unserviceable Electric Meters And Certain Other Misc Maintenance And Replacement Of Sub Mains, Dbs, Unserviceable Electric Meters And Certain Other Misc E / M Items At Af Stn Bhuj. Submission Date for this Tender is 22-09-2021. Energy Meter Tenders in GE (AF) BHUJ Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

29222347
Maintenance And Replacement Of Sub Mains, Dbs, Unserviceable Electric Meters And Certain Other Misc Maintenance And Replacement Of Sub Mains, Dbs, Unserviceable Electric Meters And Certain Other Misc E / M Items At Af Stn Bhuj
Open Tender
Indian
Gujarat
GE (AF) BHUJ
22-09-2021

Tender Details

Maintenance And Replacement Of Sub Mains, Dbs, Unserviceable Electric Meters And Certain Other Misc Maintenance And Replacement Of Sub Mains, Dbs, Unserviceable Electric Meters And Certain Other Misc E / M Items At Af Stn Bhuj

Key Value

Document Fees
INR 500 /-
EMD
INR 67000.0 /-
Tender Value
INR 33.50 Lakhs /-

BOQ Items

Name of Work: REPAIR, MAINTENANCE AND REPLACEMENT OF SUB MAINS, DB"S, UNSERVICEABLE ELECTRIC METERS HT CABLES, THREE PHASE ELECTRIC METER, LIGHT FITTINGS, TRAFFIC BARRIER AND EARTHING SYSTEM INCLUDING CONNECTED ITEMS AT AF STN BHUJ
Sl. No. Item Description
1Dismantling, disconnecting and taking down carefully unserviceableDBs incl MCBs , elect meters, AC industrial sockets etc of any size & make complete all as directed by Engineer-in-Charge.
2Taking down submain wiringof any size copper/ alluminium conductor PVC insulated with or without conduit/Casing capping all as directed by Engineer-in-Charge.
3Taking down electric meter of any capacity, cleaning and refixing the same in its original position after carried out minor repair such as, replacement of connector, screws, nutsand bolts etc complete as directed by Engineer in charge.
4Taking down old U/s light fittings complete all as specified and directed by Engr in charge.
5S&Fin replacement sheet metal enclosuredouble door type (CRCA sheet) dust and vermin proof forDB"s , IP 43 protection, 240 volt , fixed on wall complete and making all connectionsfor the following capacities all as specified directed
6MCB DB SPN 4 Way 240 Volts with 200 Ampbus bar
7MCB DB SPN 6 Way 240 Volts with 200 Ampbus bar
8MCB DB SPN 8 Way 240 Volts with 200 Ampbus bar
9MCB DB SPN 12 Way 240 Volts with 200 Ampbus bar
10S&F in replacementsheet metal enclosuredouble door type (CRCA sheet) dust and vermin proof for DB"s , IP 43 protection, 415 volt , fixed on wall complete and making all connectionsfor the following capacities all as specified directed
11MCB DB TPN 4 Way 415 Volts with 200 Ampbus bar
12S&F in replacement of isolators, MCBs, etc. In distribution board of the following rating and capacities(Make : Havell"s, L&T, Standard,Crompton/Indoasian/Polycab)
13MCB TPN 415 volts 100 Amps Capacity, 10 KA
14MCB TP 415 volts 100 Amps Capacity, 10 KA
15MCB TPN 415 volts 63 Amps Capacity, 10 KA
16MCB FP 415 volts 63 Amps Capacity, 10 KA
17MCB DP 240 volts 63 Amps Capacity, 10 KA
18MCB SPN 240 volts 40/32 Amps Capacity, 10 KA
19MCB SP 240 volts 6-40 Amps Capacity, 10 KA
20M&L for in replacement sub main wiring with two runs of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-strandedsingle core, copper conductor drawn through and including PVC casing capingISI marked with accessories and one run of equalsize single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire for the foloowing sizes complete all as specified and directed.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit)
2110 Sqmm
226 Sqmm
234 Sqmm
24Supply andfixing in replacement Tamper proof Single phase AC KWH meter10-60 Amps with following features including sealing and sealing wire, Class – 1 accuracy as per IS 13779, 240V, 50HZ LCD display, Forward energy recording irrespective of current direction,LED indication for earth leakage, elegant polycarbonate enclosure High surge with stand up to 8 KV Anti temper feature. Measures & Displays kWh.( Note: Old unserviceable elect meter will be deposited in MES store yard).
25Supply & fix in replacement of LED Garden light / Post top of 25 Watt Integral pole mounted decorative LED with IP-65 protection complete fixed on existing post/New post with all assembly and electric connection with service wire all as specified and directed by Engineer-in-Charge.Make-Bajaj Cat part no-BLPTSP 25W NW LED, or equivalant in Crompton / Philips / Wipro)
26Supply and Fix in replacement energy saving, evironment friendly, long life, corrosion resistent, impact proof, Mini LED building securitylight made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LEDs with secondary optics and IP 65 protection with LED 20 W light source all as per Havellsor equivalent in Orient/Philips/Bajaj/CG/Polycaball as specified and directed by Engineer-in-Charge.
27S & F in replacement Bracket for street light fitting made out of GI tubing 40 mm med grade pipe1.50 mtr (2" x 1 -1/2"), 135 degree bendwith cutting , welding and two MS bracket with nut bolts and washer bracing to pole/on fencing for street light fittings complete all as specified.
28S&F in Replacementmetal clad enclosure pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps. (Make : Havell"s, L&T, Standard,Crompton/Indoasian/Polycab)
29Supply and Fix in replacement of PVCbody exhaust fan, AC single phase 230/240V of size 300 mm sweep with louvers including making hole of suitable size/ Alteration to the existing hole to fix the Exhaust fan all as directed by Engineer-in-Charge. Make:- Bajaj/Havells/CG/Usha.( Note: Old unserviceable Exhaust Fan will be deposited in MES store yard).
30Supply and Fix in replacement of metal body exhaust fan, AC single phase 230/240V of size 300 mm sweep with net frame including making hole of suitable size/ Alteration to the existing hole to fix the Exhaust fan all as directed by Engineer-in-Charge. Make:- Bajaj/Havells/CG/Usha.( Note: Old unserviceable Exhaust Fan will be deposited in MES store yard).
31Supplying andfixing or passing through pipe,1100volts grade heavy duty cable with PVC insulated aluminium solid conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections of size 10 sqmm, 2 core including taking down old UNSV service cable complete all as specified and directed by Engineer-in-Charge.
32Supplying andfixing or passing through pipe,1100volts grade heavy duty cable with PVC insulated aluminium solid conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections of size 16 sqmm, 2 core including taking down old UNSV service cable complete all as specified and directed by Engineer-in-Charge.
33S&F in repairs sheet metal meter fixing boards of size 80 cm x 100 cm x 20 cm made out of 2.0 mm thick cold rolled cold Annealed (CRCA) sheet treated two coats of synthetic enamel paint over a coat of red-oxide primer after necessary preparation to surfaces complete with locking arrangement, meter fixing arrangement, rectangular glass of suitable complete with locking arragement meter fixing arrangement, rectangular glass of suitable size for meter reading and fixing the boards connecealed/on surface with addition/alterations (including taking down and re- fixing existing 5 nos energy meter single phase) complete all as specified and directed by EIC
34Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means ofnut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
35Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil soil complete all as specified and directed by Engineer-in-Charge.
36Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed.
37Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all specified and directed.
38M&L for sand cushioning for UG cables using dry river sand; gently punning down all as directed and specified. ( Note : For measurement purpose punned thickness shall be considered)
39Taking out unserviceable / serviceable HT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc, taking out old serviceable cables for reuseand removing unserviceable cables, covers etc, for the sizes of cables 95 / 120 Sqmm all as directed by Engg in charge.
40S&F in replacement of XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, HT 11000 volts, grade cross sectional area120 sqmm 3 core of size cable in trenches/fixed to poles/wall, all as specified and directed by EIC.(Note: (i)Excavation, earthwork, cable joints, sand coushing & cable coverwill be measured and paid separately if required)
41M & L unreinforced precast concrete cable covers CLASS HV type I, flat size 300 x 180 x 40 mm laid transverse to cable.
42Laying only in replcementof HT 11 KV 3 core 120 Sqmm cable in trenches/fixed to poles/wall, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable( HT ), heavy duty with aluminium conductor, 11000 volts (earthed) grade 95/120 Sqmm x 3 coreall as specified and directed by EIC.
43Suppl and fixing in replacement ofoutdoor type heat shrinkable cable end joint for 3 core, 120 to 185 Sqmm HT, 11 KV (earth), XLPE insulated heavy duty aluminium conductor cable including making incoming and outgoing electrical connections all as directed Make- Denson/M-Seal
44S&F in replacement of GI tubing 100 mm borelight grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS clamps with necessary bolts, nuts and washers all as specified.
45M& L for finding out HT fault in feederofaffected area with deploying trained electrician and helper seggregate/ isolatethe feeder carry out maintenance worksuch as repair of jumper, DOs, GODs, fuse wires of suitable gauge, insulators ,conneted items and then after charge the feeder with load in presence of Engr-in-charge.
46S & F synthetic insulating mat of size 2mx1mx19mm all as specified and as directed by Engr-in-Charge.
47S& F in replacement ofelectrical insulating Mat (electromat) ClassC, B.I.S.+ CPRI + ERDA approved , as per 15652 ; 2006, size 1 Mtr x 2 Mtr, thickness 2.5 to 3 mm for system voltage 11 KV Min colour blue, Finish one side plain/one side patterned (Antiskid design), having tensile strength of 15N/mm for temperature range of -10 to 55 degree centigrade, insulation resistance with water 1000000 m ohm (min), leakage current ; 10 uA (Max) flame retardant, No effect of Trasformer oil , Acid, Diesel, Alkali all as directed by engineer in charge.
48Supply and fix in replacement Cable jointing kit for 11 KV (Earthed)grade cable for Straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size up to 120 Sqmm 3 core all as directed.
49Supply and fix in replacementCable jointing kit for 11 KV (Earthed)grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size up to 120 Sqmm 3 core all as directed.
50S & F in replacement of Isolation Transformer of 2 KVA capacity single phase 230 V including I/C & O/G control switch LED indicator lamp, Voltmeter / Amp meter with all connected accessories all as directed by EIC. Make Volina /AE or equivalent.
51Supply and fix in Replacement for flame proof and weather proof (Protection Class IP-65) enclosure suitable for LED tube light fitting including LED Light 2X40 watt,with LED & Driver, internal reflector, and Integral type fittings aluminium cast alloy LM-6,inside and outside light grey epoxy coating,prewired complete with connector block etc.all accessories fixed onon wall or on ceiling and connecting up complete with 23/0.0076 flexible three core copper cable in flexible steel conduict with flame proof cable glands all as specified and directed. Make: Crompton Greaves, Sudhir Switchgears Ltd., BALIGA, FCG/ Shyam Switchgears Ltd
52S & F in replacement of Digital protective relay ( for HT VCB) of 3 phase over current /earth fault with high set C.T. Rating 1A or 5A , field selectable , Aux.supply 24V-240V AC/DC and out put contacts 4 NO Type .Cat Part No.MC61ANX4000 Make :-L & T or equivalant crompton greaves CG 14N relay as approved by GE.
53S & F in replacement of Barrier boom length 6.0 metre, Opening / Closing timing between 2 to 6 sec and having smooth operation of rising boom barrier while open and close functions without bounce / jerks at end positions and also easily raised or lowered by releasing the boom lock with key type mechanism when power supply failure all as specified and as directed.
54S & F inreplacement ofthree phase AC KWH meter 10-60 Amps with following features including sealing and sealing wire. Class – 1 accuracy as per IS 13779, 3 x 240V, 50HZ LCD display Forward energy recording irrespective of current direction, LED indication for earth leakage, elegant polycarbonate enclosure, High surge with stand up to 8 KV, Measures & Displays kWh. Make L & T: cat part EM301B+ / SECURE I CRADIT / HPL
55M&L for complete cleaning of the internal and external parts of the electronic Hooterchecking & testing of all the components of the hooter for cable insulation, lugs, connections and the like, replacement of & including provision of minor parts like lugs, insulation tape as per colour code, nuts bolts, connectors, greasing the internal parts as directed by Engineer-in-Charge.
56M&L for earthing complete with copper earth plate electrode of size 60cmx60cm x 3.15 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal groundlevel connected to and including copper stripof 20 x 3 mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steelincluding provn of HDPE protectionpipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicatedand testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete. Note: copperI strip exceeding 7.5m long shall be measured & paid seperately.
57S&Fcopper strip 20 x3.15 mm with saddles and fixing screws etc for roof/down conductor above ground including jointing with rivets/ brazing etc all as directed by engineer-in-charge complete.
58S&F test point terminal block made of gun metal / phosphorus bronze/copper of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw all as specified and directed.