Archaeological Survey Of India -ASI has published Srp Illumination To The Beach Ghantikiburuzu ( Locally Known As Konda Reddy Burz ) Kurnool, Andhra Pradesh As Per Tender Document. Submission Date for this Tender is 18-10-2021. Electrification Work Tenders in Kurnool Andhra Pradesh Andhra Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Oct-2021 | 1st Corrigendum Notice for Extension of Tender Submission Date | Date | 18-10-2021 |
Sl. No. | Item Description |
1 | Electrical Items : |
2 | Item No.1: "Supply, installation, testing & commissioning of Approved BIS standardIndian make LED luminaire with system power [40W ± 5%], available in colour temperature of 2200K, made of Extruded Aluminium housing for better Thermal Dissipation andassymmetrical beam angle 15 X 45for optimum light output. The fixture should be powder coated by Corrosion resistant Nano coating technology. The colour of fixture should be in Terracotta colour. with 5 years of Comprehensive Operation, Maintenance including defect liability period.Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-270V, power factor > 0.95, THD < 5%, IP66 protection, Inbuilt surge protection of 5 KV and upgraded with integrated IP67 protected SPD of 10KV/5KA surge protection with all necessary safet protecion like mis wiring, Over voltage, Short circuit, Reverse Polarity protection.Luminaire should have an Ingress protection of IP66 and Impact Resistance of IK08. The luminaire lumen output>90LPW & system efficacy of >3600 Lm , CRI of 70 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification: Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & DriversDriver Efficiency :>85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%.The luminaire should be provided with Electrical safety class I. Power Factor > 0.9.Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBs with "OEM Certification for this tender" as per Engineer-in-Charge with proper metal cages for lights protections" |
3 | Item No.2: "Supply, installation, testing & commissioning ofApproved BIS standardIndian make LED Floodlight luminaire with system power [100W ± 5%], Available incolour temperature 3000K,madeof a single piecePressurediecastaluminium (PDC)housing with separate driver and optical compartment for Thermal isolation & Powder coated by Corrosion resistant Nano coating technology. The fixture provided has to be with an injection moulded UV stabilized Polycarbonate cover & Lens optics with beam angle of60° beam angle for optimum light spread. The colour of the fixture should be terracotta. with 5 years of Comprehensive Operation, Maintenance including defect liability period.Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-305V AC, power factor > 0.95, THD < 10%, IP67 protection, Inbuilt surge protection of 10 KV and upgraded with integrated IP67 protected SPD of 10KV/5KA surge protection with all necessary safet protecion like mis wiring, Over voltage, Short circuit, Reverse Polarity protection.Luminaire has a Ingress protection of IP66 and Impact Resistance of IK07.The luminaire lumen output> 130 LPW & system efficacy of >11200 Lm , CRI of 70 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70. Suitable for Cradle mount application. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification:CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers Driver Efficiency :>85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%.The luminaire should be provided with Electrical safety class I. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBswith "OEM Certification for this tender"as per Engineer-in-Charge with proper metal cages for lights protections." |
4 | Item No.3: "Supply, installation, testing & commissioning of Approved BIS standardIndian make LED Floodlight luminaire with system power [170W ± 5%], Available in colour temperature 3000K,madeof a single piecePressurediecastaluminium (PDC)housing with separate driver and optical compartment for Thermal isolation & Powder coated by Corrosion resistant Nano coating technology. The fixture provided has to be with an injection moulded UV stabilized Polycarbonate cover & Lens optics with beam angle of10° for optimum light spread. The colour of the fixture should be terracotta.with 5 years of Comprehensive Operation, Maintenance including defect liability period.Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-305V AC, power factor > 0.95, THD < 10%, IP67 protection, Inbuilt surge protection of 10 KV and upgraded with integrated IP67 protected SPD of 10KV/5KA surge protection with all necessary safet protecion like mis wiring, Over voltage, Short circuit, Reverse Polarity protection.Luminaire has a Ingress protection of IP66 and Impact Resistance of IK07.The luminaire lumen output> 130 LPW & system efficacy of >19100 Lm , CRI of 70 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70. Suitable for Cradle mount application. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification:CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers Driver Efficiency :>85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%.The luminaire should be provided with Electrical safety class I. Power Factor > 0.9.Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBswith "OEM Certification for this tender"as per Engineer-in-Charge with proper metal cages for lights protections" |
5 | Item No.4: Supply, installation, testing & commissioning of Approved BIS standardIndian make LED Floodlight luminaire with system power [50W ± 5%], available incolour temperature 2200K,madeof a single piecePressurediecastaluminium (PDC)housing with separate driver and optical compartment for Thermal isolation & Powder coated by Corrosion resistant Nano coating technology. The fixture provided has to be with an injection moulded UV stabilized Polycarbonate cover & Lens optics with beam angle of60° for optimum light spread. The colour of the fixture should be terracotta. with 5 years of Comprehensive Operation, Maintenance including defect liability period.Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-305V AC, power factor > 0.95, THD < 10%, IP67 protection, Inbuilt surge protection of 10 KV and upgraded with integrated IP67 protected SPD of 10KV/5KA surge protection with all necessary safet protecion like mis wiring, Over voltage, Short circuit, Reverse Polarity protection.Luminaire should have an Ingress protection of IP66 and Impact Resistance of IK07.The luminaire lumen output> 130 LPW & system efficacy of >5600 Lm , CRI of 70 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70. Suitable for Cradle mount application. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification:CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers Driver Efficiency :>85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%.The luminaire should be provided with Electrical safety class I. Power Factor > 0.9.Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBs with "OEM Certification for this tender"as per Engineer-in-Charge with proper metal cages for lights protections. |
6 | Item No.5: "Supply, installation, testing & commissioning of Approved BIS standardIndian make LED Floodlight luminaire with system power [50W ± 5%], available incolour temperature 3000K,madeof a single piecePressurediecastaluminium (PDC)housing with separate driver and optical compartment for Thermal isolation & Powder coated by Corrosion resistant Nano coating technology. The fixture provided has to be with an injection moulded UV stabilized Polycarbonate cover & Lens optics with beam angle of60° for optimum light spread. The colour of the fixture should be terracotta. Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-305V AC, power factor > 0.95, THD < 10%, IP67 protection, Inbuilt surge protection of 10 KV and upgraded with integrated IP67 protected SPD of 10KV/5KA surge protection with all necessary safet protecion like mis wiring, Over voltage, Short circuit, Reverse Polarity protection.Luminaire should have an Ingress protection of IP66 and Impact Resistance of IK07.The luminaire lumen output> 130 LPW & system efficacy of >5600 Lm , CRI of 70 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70. Suitable for Cradle mount application. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification:CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers Driver Efficiency :>85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%.The luminaire should be provided with Electrical safety class I. Power Factor > 0.9.Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBswith "OEM Certification for this tender" as per Engineer-in-Charge with proper metal cages for lights protections." |
7 | Item No.6: "Supply, installation, testing & commissioning of Approved BIS standardIndian make LED Floodlight luminaire with system power [15W ± 5%], available in color temperature of 3000K and beam angle 30 degree, made of Pressure die cast Aluminium [PDC] Housing for better Thermal Dissipation.Powder coated by Corrosion resistant Nano coating technology. The colour of fixture should be terracotta. Tilt angle 180" deg.Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-270V, power factor > 0.95, THD < 5%, IP66 protection, Inbuilt surge protection of 5 KV and upgraded with integrated IP67 protected SPD of 10KV/5KA surge protection with all necessary safet protecion like mis wiring, Over voltage, Short circuit, Reverse Polarity protection. Luminaire should have an Ingress protection of IP66 and Impact Resistance of IK08. ?The luminaire lumen output~90 LPW & system efficacy of >1300 Lm , CRI of 70 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & DriversDriver Efficiency :>85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%.The luminaire should be provided with Electrical safety class I. Power Factor > 0.9.Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBswith "OEM Certification for this tender"as per Engineer-in-Charge with proper metal cages for lights protections." |
8 | Item No.7: "Supply, installation, testing & commissioning of Approved BIS standardIndian make LED luminaire with system power [20W ± 5%], Available in color temperature 3000K and beam angle of 30 degree,made of Pressure die cast Aluminium [PDC] housing for better Thermal Dissipation. Powder coated by Corrosion resistant Nano coating technology. The colour of fixture should be Teracotta. with 5 years of Comprehensive Operation, Maintenance including defect liability period.Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-270V, power factor > 0.95, THD < 5%, IP66 protection, Inbuilt surge protection of 5 KV and upgraded with integrated IP67 protected SPD of 10KV/5KA surge protection with all necessary safet protecion like mis wiring, Over voltage, Short circuit, Reverse Polarity protection.Luminaire has a Ingress protection of IP66 and Impact Resistance of IK08. ?The luminaire lumen output>75LPW & system efficacy of >1500 Lm , CRI of 70 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Driverswith "OEM Certification for this tender " |
9 | Item No.8: Supply, installation, testing & commissioning of standardIndian make customised Outdoor rated Bollard Pathway Light 10W with housing of Pre cast Concrete Cement Bodyor Terracota Sandblast / Grey Finish Coatingand Light fixture body : Aluminium / PCLuminaire Wattage 10W, Well designed thermal management system with aluminium heat sink Operating Voltage of AC 165-270V 50HZ with universal elcectronic driver, Light colour should be inyrange of 2700-3000K, , Mean rated service life L70(tq 25 °C) = 50,000 h.Ingress protection rating (DIN EN 60529): IP65,with "OEM Certification for this tender"The luminaire should be provided with Electrical safety class I. Operating Temperature 0 deg to +50 deg with 5 years of Comprehensive Operation, Maintenance including defect liability period.. |
10 | Item No.09 Suuply, installation, testing & commissioning of the required earthing system (3 nos.) as per standard engineering practice and the drawings attached. The sectional drawing for the recommended earthing system is attached for reference. To be verified by Engineer-in-charge. |
11 | Item No.10 Supply & Installation of Stone fitments, in sandstone to match with the existing material of the monument, with special adhesive for Luminarie installations. Size would range from 15cm to 50cm, as per site requirement & to be verified by Engineer-in-charge. |
12 | Item No.11 Supply & Installation of customised wooden channel/conduit &stone channel/conduit (for pathways) , made up of exterior-grade water-resistant/ weatherproof/ termite proof, salt resistant and sturdy MDF board to accommodate the running cables throughout the monument. Thickness of the MDF board should be minimum 10mm. The section drawing is attached for reference. |
13 | Item No.12 Supply and Laying of one number 4 core x25 sq mm ISI MarkedAluminium UnArmoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
14 | Item No.13 Supply and laying of 4.0 sq. mm x 3 core ISI marked, FRLS PVC insulated, single core copper conductor cable in the wooden channel with proper connections, glands, etc |
15 | Item No.14 Supply and fixing Power Supply 24V, 6.3A, 150W |
16 | Item No.15 Supply and fixing IP67 weatherproof box for Power Supply with cable glands at input and output of the box, size of the box should be sufficient to accommodate the power supply of the fixtures. |
17 | Item No.16 Excavation of soft soil with minimum depth of 300 mm and maximum upto 900 mm and width of 300 mm required for laying of main cable/branch luminarie cables etc. and refill with 15cm thick River sand covered with precast slab/ brick and remaining with earth and to bring back the earth in original condition and providing inspection chambers wherever required. |
18 | Item No.17 DEFECT LIABILITY PERIOD 5 YEARS - FREE MAINTENANCE OF THE ILLUMINATION FOR FIVE YEARS. 17(a) Operation & Maintenance and defect liability Charges including replacement of defective fixtures, cables, labour charges etc. from the date of testing and commissioning of the project for the first year |
19 | Item No.17(b). 17(b). Operation & Maintenance and defect liability Charges including replacement of defectivefixtures, cables, labour charges etc. for 2nd year from the date of expiring the first year warranty period, after testing and commissioning of the project for the Second year |
20 | Item No.17(c). 17(c). Operation & Maintenance and defect liability Charges including replacement of defectivefixtures, cables, labour charges etc for 3rd year from the date expiring the second year warranty period For the third year |
21 | Item No.17(d). Operation & Maintenance and defect liability Charges including replacement of defective fixtures, cables, labour charges etc for 4th year from the date expiring the third year warranty period For the fourth year |
22 | Item No.17 (e). Operation & Maintenance and defect liability Charges including replacement of defective fixtures, cables, labour charges etc for 5th year from the date expiring the fourth year warranty period For the fifth Year |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail