Providing And Fixing Smart Water Meter With Setup Of Advanced Metering Infrastructure ( Ami ) In Pilot Project Area With 10 Years O And M. ) Noida, NOIDA-Uttar Pradesh

New Okhla Industrial Development Authority-NOIDA has published Providing And Fixing Smart Water Meter With Setup Of Advanced Metering Infrastructure ( Ami ) In Pilot Project Area With 10 Years O And M. ) Noida. Submission Date for this Tender is 20-09-2021. Infrastructure Work Tenders in NOIDA Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29194594
Providing And Fixing Smart Water Meter With Setup Of Advanced Metering Infrastructure ( Ami ) In Pilot Project Area With 10 Years O And M. ) Noida
Open Tender
Indian
Uttar Pradesh
NOIDA
20-09-2021

Tender Details

Providing And Fixing Smart Water Meter With Setup Of Advanced Metering Infrastructure ( Ami ) In Pilot Project Area With 10 Years O And M. ) Noida

Key Value

Document Fees
INR 8260 /-
EMD
INR 1911800.0 /-
Tender Value
INR 9.46 Crore /-

BOQ Items

Name of Work:Providing and fixing smart water meter with setup of Advanced Metering Infrastructure (AMI) in pilot project area with 10 years O&M.
Sl. No. Item Description
1MultiJet AMR Water Meter with Brass End Couplings - Domestic Water Meter should be straight reading type, Battery Operated, AMR enabled, inferential type, multi jet, magnetically coupled, having dry dial, copper can, Brass/Bronze Body, Class ’B’ conforming to IS-779: 1994 with up to date amendments or ISO 4064:1993 standard with ISI/EEC/OIML/MID certification mark shall be with protection class of IP-68. The meter should have 10 years warranty. The Meter Should have FCRI Life Cycle test approval.1.01) DN 15mm
2DN 20mm
3DN 25mm
4DN 40mm
5Installation of MultiJet AMR Water Meter(i/c all the fittings if needed) 02.01) DN 15mm
6DN 20mm
7DN 25mm
8DN 40mm
9Woltman type AMR Bulk Water Meter - Water meter should beBattery operated, AMR enabled, straight reading, inferential type, woltman type, magneticallycoupled, having dry dial, Class ’B’ conforming to ISO 4064-2005standards with latest amendment with protection class of IP-68. The meter should have FCRI Accuracy Test approval. 3.01) DN 50mm
10DN 65mm
11DN 80mm
12DN 100mm
13DN 150mm
14DN 200mm
15DN 250mm
16DN 300mm
17Installation of Bulk Meters (i/c all the fittings like Strainer, flanges nuts bolts, with minor civil works if needed etc) 4.01) DN 50mm
18DN 65mm
19DN 80mm
20DN 100mm
21DN 150mm
22DN 200mm
23DN 250mm
24DN 300mm
25Supply and Installation of PE Box for 15 mm, 20 mm, 25 mm and 40 mm
26One Time Charges – Fixed System Set up Charges – RF/LPWAN/LoRa Wan/SigFox (to Cover NOIDA Area)
27Software – Meter Reading (HES) Head End System Acquires the data from Meter and Sends the data to Meter Data Management System.
28Software – Meter Data Management Water Meter Data Management System Software – Meter Data Management Water Meter Data Management System supports storage, archiving, retrieval & analysis of water meter data and various other MIS along with validation & verification algorithms. It acts as a central data repository. MDM shall have capability to import raw or validated data in defined formats and export the processed and validated data to various other systems sources. Following are the MDM Features 1. Asset Management 2. Meter Data Analysis 3. Validation Estimation and Edition 4. Billing Determinants Calculations 5. Exception Management 6. Service Orders 7. Business Intelligence Analytics and Reporting 8. Revenue Protection Support
29Software – Billing Revenuer Management System A comprehensive web-based platform to operate & maintain all information management modules i.e. Billing, Meter Management, Disconnection and Reconnection, Revenue Collection, CRM, CIS, etc of Department. The application shall be composed of an n-tier system in which a client obtains processed information from a remote application server. Following are the modules of RMS System. 1. New Connection Management System 2. Metering 3. Billing 4. Collection and Reconciliation 5. Consumer Information System 6. Disconnection, Dismantling and Reconnecting Management 7. Customer Portal /Web self service 8. MIS Reports and Dashboards 9. Mobile Device Management System 10. Centralized Customer Care System
30Mobile Apps:- Consumer App MIS and Monitoring App Field Work Force app for operations and maintenance activities.
31Operation and Management Charges for 10 Years for 5000 water meters which will include the following:- 1. Metering, Reading, Billing and Distribution 2. Operation and maintenance of complete system and setup 3. O&M of Test Bench
32Test Bench Operation Manual Meter SizeDN15 Number Of Meters10 for DN 15mm Flow rateMaximum 10,000 l/h, minimum 10 l/h Flow adjustment3 lines, with flow ranges of 10 to 100 l/h ,100 to 1,000 l/h and 1,000 to 10,000 I/h SystemPneumatic Clamping & Electro-Pneumatic testing automated-stop system. Three independent manual adjustment lines Reference device Two calibrated stainless steel tanks •?Calibrated tank 1 : nominal volume 10 liters, reading graduation 0.01 liter •?Calibrated tank 2 : nominal volume 100 liters, reading graduation 0.1 liter
33Constructing mesonary Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter, and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :5 fine sand : 10 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thich, finished with a floating coat of neat cement complete as per standarddesign: 18:33:1 With common burnt clay F.P.S (non modular) bricks of class designation 10.00
34Constructing mesonary Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter, and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :5 fine sand : 10 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thich, finished with a floating coat of neat cement complete as per standarddesign: 18:34:1 With common burnt clay F.P.S (non modular) bricks of class designation 10.00