Periodical Services To Certain Buildings At Minicoy Under Ge Navy Lakshadweep Periodical Services To Certain Buildings At Minicoy Under Ge Navy Lakshadweep, Minicoy-Lakshadweep

Military Engineer Services-MES has published Periodical Services To Certain Buildings At Minicoy Under Ge Navy Lakshadweep Periodical Services To Certain Buildings At Minicoy Under Ge Navy Lakshadweep. Submission Date for this Tender is 12-10-2021. Building Work Tenders in Minicoy Lakshadweep. Bidders can get complete Tender details and download the document.




Tender Notice

29190655
Corrigendum : Periodical Services To Certain Buildings At Minicoy Under Ge Navy Lakshadweep Periodical Services To Certain Buildings At Minicoy Under Ge Navy Lakshadweep
Open Tender
Indian
Lakshadweep
Minicoy
12-10-2021

Tender Details

Periodical Services To Certain Buildings At Minicoy Under Ge Navy Lakshadweep Periodical Services To Certain Buildings At Minicoy Under Ge Navy Lakshadweep

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-10-2021
2 11-Oct-2021 Due Date Extended Admin Corrigendum Date Extend 12-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 14000.0 /-
Tender Value
INR 7 Lakhs /-

BOQ Items

NAME OF WORK: PERIODICAL SERVICES TO CERTAIN BUILDINGS AT MINICOY UNDER GE NAVY LAKSHADWEEP
Sl. No. Item Description
1Material and Labour for complete removal of exisiting treatment on wall surfaces and applying damp proof coating in three layer treatement by applying first coat of Dr. fixit Dampguard classic followed by a coat of Dr. fixit Dampguard classic putty prepared by mixing 1 part of Damguard classic with 1 part of white cement (OPC) mixed so as to obtain consistency of a putty and finally applying second coat of Dr. fixit Dampguard classic, complete all as per manufacturers instructions, the treated surfaces shall be finished smooth and followed by two coats ofdistemper oil emulsion over a coat of alkali resistant primer, complete all as specified and directed by Engineer-in-Charge. Note: Rate quoted is deemed to include for providing 104 Dampguard classic of Make Dr. Fixit completely in three layers including layer of putty, as per manufactures instruction upto the satisfaction of Engineer-in-Charge inorder to obtain desired finish and for arresting dampness completely.
2Taking down cement plaster on brick walls or stone walls any descrition etc... including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed by Engineer-in-Charge.
3Material and Labour for Rendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and as directed.
4Rendering 5 mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:3),as in ceiling, finished even and fair without using extra cement all as specified and directed by Engineer-in-Charge.
5Material and Labour Rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cementincluding mixing of water proofing compound @ 3% by weight of cement, complete all as specified and directed by Engineer-in-Charge. Note: WPC will be measured and paid seperately as supply only item.
6Supply only integral water proofing compound
7Material and labour for preparation of new plastered surface of wall and applying 1.5 mm thick wall care putty and making the surface smooth followed by Two coats of Distemper oil emulsion, acrylic distemper (ready mixed), of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification over a coat of alkali resistant primer complete all as specified & directed by Engineer-in-Charge.
8Material and Labour three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed by Engineer-in-Charge.
9Material and Labour for preparation old decorated painted surfaces of walls and applying one coat of exterior weather proof emulsion paint complete all as specified and directed by Engineer-in-Charge.
10Material and Labour for preparation old decorated painted surfaces of walls and applying one coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
11Material and labour for Complete removal of existing treatment and applying two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed by Engineer-in-Charge.
12Material and Labour for preparation of newly plastered and concrete surfaces and applying two coats of exterior emulsion weather proof paint (Appex Ultima or equivalent) of any colour, over a coat of exterior primer, over a coat of cement based exterior putty not less than 1mm thick on wall/column projection, chajjas sides and bottom, roof projection, wall etc... completely all as specified and directed by Engineer-in-Charge.
13Material and labour for Complete removal of existing treatment and applying one coat of Dr. Fixit Raincoat weatherproof coating without any dilution to maintain a spread of 4.0 Sqmt per liter per coat to achieve 120-130 micron thickness and after drying applying two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqmcomplete all as specified and directed by Engineer-in-Charge. Note: Rate quoted shall be deemed to include for necessary scaffoldings for buildings upto G+1 Storey, Dr. Fixit Raincoat weatherproof coating as per manufacturers instructions, exterior primer and Weather proof emulsion paint
14Material and Labour for preparation old decoratedpainted surfaces of ceiling and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge.
15Material and Labour for preparation old decorated painted surfaces of walls and applying one coat distemper oil emulsion complete all as specified and directed by Engineer-in-Charge.
16Material and Labour for preparation old decorated painted surfaces of wallsand applying one coat cement base paint, for compound walls, manholes, septic tanks, kerbs, valve pits etc… complete all as specified and directed by Engineer-in-Charge.
17Material and Labour for one coat of synthetic enamel paint on wooden surfaces including preparation of old painted surfaces, over 10cm width or girth, complete all as specified and directed by the Engineer-in-Charge
18Material and Labour for one coat of Epoxy enamel painton steel surfaces including preparation of old painted surfaces, over 10cm width or girth, complete all as specified and directed by the Engineer-in-Charge