Construction Of Compound Walling Control Room Building Earth Mat Rcc Foundations And Cable Trench Etc For 1X6.3 Mva 33-11Kv Receiving Station Qamar Under Capex Budget 2021-22 C , Qamar-Jammu And Kashmir

Power Development Department has published Construction Of Compound Walling Control Room Building Earth Mat Rcc Foundations And Cable Trench Etc For 1X6.3 Mva 33-11Kv Receiving Station Qamar Under Capex Budget 2021-22 C . Submission Date for this Tender is 05-10-2021. Foundation Work Tenders in Qamar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

29181514
Construction Of Compound Walling Control Room Building Earth Mat Rcc Foundations And Cable Trench Etc For 1X6.3 Mva 33-11Kv Receiving Station Qamar Under Capex Budget 2021-22 C
Open Tender
Indian
Jammu And Kashmir
Qamar
05-10-2021

Tender Details

Construction Of Compound Walling Control Room Building Earth Mat Rcc Foundations And Cable Trench Etc For 1X6.3 Mva 33-11Kv Receiving Station Qamar Under Capex Budget 2021-22 C

Key Value

Document Fees
INR 1000 /-
EMD
INR 218400.0 /-
Tender Value
INR 72.80 Lakhs /-

BOQ Items

Name of Work:-Construction of Compound Walling, Control Room Building, Earth Mat, RCC Foundations & Cable Trench etc for 1x6.3MVA ,33/11KV Receiving Station Qamar.
Sl. No. Item Description
1Design, engineering & construction of Control Room Building for new 33/11 kV receiving substation consisting of RCC Slab with CGI sheet roofing along with steel trusses including indoor trenches, comprising of battery room, panel room, administration room, toilet etc as required of overall building size of 10mX12m (or as per electrical requirement) , single story including all internal services like water supply, Fittings, accesories, Sewerage system, Finishing, Plinth Protection, including supply of construction materials, Labour, Cement, Reinforcement Steel, Frame Work, Excavation etc, complete in all resect including Truss, Internal wiring and roofing as per detailed Technical Specification, approved Drawings & Scope of works. Plinth area 111 sqm. (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
2Compound walling of identified land by way of mass concrete infoundations & 228mm Brick Wall of 2 M height (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
3Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
4Cable Trench for laying of 11 kV XLPE Cable from Power Transformer & 11KV Gantry to Control Room (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
5Construction of RCC foundation for33/11 kV Power Transformers (3.0 m x2.8 m x 1.5m) incuding guide rail , considering original equipment manufacturer recommendations includingshuttering and by providing reinforcement, cement concreting,in 1:2:4,painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting. (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
6Construction of RCC foundation foroutdoor mounted Vacuume Circuit Breaker, Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers. (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
7Earthing Mat (GI Flat 50 mm x8 mm) for both power transformor Bays (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
8EarthingElectrode ( 3m long 40mm dia GI pipe) through GI Strip.(the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
933 kV Yard Concreting/Metalling for new Substation) Providing, supplying and laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and spreading 100mm thick layer of 20mm single size uncrushed/crushed/ broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 20mm single size uncrushed/crushed/broken stone pebbles wherever required in the bays covered under the scope as per Technical Specification, approved Drawing & Scope of works. & instructions of Engineer-in charge. (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
10Borewell with submersible pump complete with all accessories (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
11Development of land by removing weeds, wild grass and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas and road sides and development of roads along with surface drains. Total Areas shall be 2 to 2.5 Kanals (the design/drawing/reinforcement/concrete mix will be as per standards adopted by department under REC/PMDP/DDUGJY/IPDS)
Disclaimer :