Renovation Of Iei To First Floor Of Child Ward At G.B.Pant Hospital, Port Blair ( Re-Call ) Renovation Of Iei To First Floor Of Child Ward At Gb Pant Hospital Port Blair. Re-Call, Port Blair-Andaman And Nicobar Islands

Andaman And Nicobar Islands Medical Education and Research Society-ANIMERS has published Renovation Of Iei To First Floor Of Child Ward At G.B.Pant Hospital, Port Blair ( Re-Call ) Renovation Of Iei To First Floor Of Child Ward At Gb Pant Hospital Port Blair. Re-Call. Submission Date for this Tender is 21-09-2021. Electrical Maintenance Tenders in Port Blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

29167403
Renovation Of Iei To First Floor Of Child Ward At G.B.Pant Hospital, Port Blair ( Re-Call ) Renovation Of Iei To First Floor Of Child Ward At Gb Pant Hospital Port Blair. Re-Call
Open Tender
Indian
Andaman And Nicobar Islands
Port Blair
21-09-2021

Tender Details

Renovation Of Iei To First Floor Of Child Ward At G.B.Pant Hospital, Port Blair ( Re-Call ) Renovation Of Iei To First Floor Of Child Ward At Gb Pant Hospital Port Blair. Re-Call

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 7.08 Lakhs /-

BOQ Items

Name of Work: Renovation of IEI to Ist floor of Child Ward at GB Pant Hospital, Port Blair.(Re-call)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
2Group C
3Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
4Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
52 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
64 X 6 sq. mm + 2 X 6 sq. mm earth wire
7Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
85/6 A switch
93 pin 5/6 A socket outlet
10Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
12Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
13Supplying and fixing 3pin, 5A ceiling rose on the existing junctionbox/woodenblockincludingconnectionsetc.as required.
14Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
15Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
16Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
17Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
18Upto 450 mm sweep
19Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
20SupplyingandfixingPVC batten/angle holderincluding connections etc. as required.
21Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
228 way (4 + 24), Double door
23Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required.
24Single pole
25Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2640 A
2763 A
28Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet,with 2poleandearth,metalenclosedplugtop alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
29Supplying of 5 star Energy saving ceiling fans BLDC 26W to 32W 1200mm sweep, white colour. Make Usha, Model (Energia 32)/ Havells (Efficiencia/ Energion)/orient(Atomiser)
30Supplying of following sizes of Exhaust fan with ISI mark and protective bird guard. (Make : Havells/ Bajaj/CromptonGreaves/ Usha.
31Exhaust fan 300mm x 900rpm of metallic heavy duty equivalent to Havells Turbo Force SP
32Exhaust fan 380mm x 900rpm of metallic heavy duty equivalent to Havells Turbo Force SP
33Supplying of LED lamp with base B22 .
340.5W Colour
359W, 825lm CDL
36Supplying of industrial LED battens. Make Philips Model TMC 501 P 1xT-LED 22W P3241
37Supplying of LED tube of 1200mm long, 20W T8 with 2100lm. Make Philips.