Repair / Replacement Of Main Distribution Board / Sub Main Wiring, Heating Appliances And Servicing Of Dg Set At Old Cantt And Fort Cantt Allahabad Repair / Replacement Of Main Distribution Board / Sub Main Wiring, Heating Appliances And Servicing Of Dg, Allahabad-Uttar Pradesh

Military Engineer Services-MES has published Repair / Replacement Of Main Distribution Board / Sub Main Wiring, Heating Appliances And Servicing Of Dg Set At Old Cantt And Fort Cantt Allahabad Repair / Replacement Of Main Distribution Board / Sub Main Wiring, Heating Appliances And Servicing Of Dg. Submission Date for this Tender is 09-10-2021. Electrification Work Tenders in Allahabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29164730
Corrigendum : Repair / Replacement Of Main Distribution Board / Sub Main Wiring, Heating Appliances And Servicing Of Dg Set At Old Cantt And Fort Cantt Allahabad Repair / Replacement Of Main Distribution Board / Sub Main Wiring, Heating Appliances And Servicing Of Dg
Open Tender
Indian
Uttar Pradesh
Allahabad
09-10-2021

Tender Details

Repair / Replacement Of Main Distribution Board / Sub Main Wiring, Heating Appliances And Servicing Of Dg Set At Old Cantt And Fort Cantt Allahabad Repair / Replacement Of Main Distribution Board / Sub Main Wiring, Heating Appliances And Servicing Of Dg Set At Old Cantt And Fort Cantt Allahabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Sep-2021 Revised BOQ and Amendment BOQ 09-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 78000.0 /-
Tender Value
INR 44.69 Lakhs /-

BOQ Items

Name of Work: Repair/replacement of main distribution board/sub main wiring, heating appliances and Servicing of DG set at Old Cantt and Fort Cantt Allahabad.
Sl. No. Item Description
1Taking down main switches, distribution boards and cut outs of any capacity along with the exisitng boards and removing the same from site and keeping in safe custody for reuse or issue on credit to contractor and making good disturbed surface or portion of walls complete all as specified & directed.
2Taking down carefully sub main wiring of any numbers of wire on wooden batten or surface conduit or concealed conduits / casing caping any type complete all as specified & directed.
3Sub main wiring with two single core PVC insulated unsheathed, grade cable 4.0 sqmm (nominal area) FR type multi stranded copper conductor and one run of 4 sqmm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS & cutting chasing for conduit & sinking for boxes & making good to walls disturbed surfaces & applying finishes to match existing surfacesand including 20mm dia "medium grade"PVC conduit and fittings,complete all as specified and directed. Note: One unit length shall be measured as two run of main wire and one run of conduit & earth wire.
4Sub main wiring with two single core PVC insulated unsheathed, grade cable 6.0 sqmm (nominal area) FR type multi stranded copper conductor and one run of 6 sqmm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS & cutting chasing for conduit & sinking for boxes & making good to walls disturbed surfaces & applying finishes to match existing surfacesand including 20mm dia "medium grade"PVC conduit and fittings,complete all as specified and directed. Note: One unit length shall be measured as two run of main wire and one run of conduit & earth wire.
5Sub main wiring with two single core PVC insulated unsheathed, grade cable 6.0 sqmm (nominal area) FR type multi stranded copper conductor and one run of 6 sqmm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS & cutting chasing for conduit & sinking for boxes & making good to walls disturbed surfaces & applying finishes to match existing surfacesand including 20mm wide PVC suface casing caping and fittings,complete all as specified and directed. Note: One unit length shall be measured as two run of main wire and one run of conduit & earth wire.
6Sub main wiring with four single core PVC insulated unsheathed, grade cable 16.0 sqmm (nominal area) FR type multi stranded copper conductor and one run of 16 sqmm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS & cutting chasing for conduit & sinking for boxes & making good to walls disturbed surfaces & applying finishes to match existing surfacesand including 32mm dia "medium grade"PVC conduit and fittings,complete all as specified and directed. Note: One unit length shall be measured as four runs of main wire and one run of conduit & earth wire.
7Earthing complete with GI earth plate electrode 600mm x 600mm x 6mmthick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15mm dia GI pipe "light grade", GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber and mild steel angle iron frame 40 x 40 x 3 mm and40mm thick pre-cast RCC cover (1:2:4), type B-1 (using 20mm graded crushed aggregate) mix with 8mm dia MS bars @75mm c/c both ways, mild steel handle 12mm dia, PGI funnel and wire mesh, 15mm dia GI pipe light grade(ISI marked) for watering, etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. Note: The quoted rates shall also deemed to include the cost of Earth Test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode.
8Wall mounted LT panel board of size 1000 mm x 1000 mm x 150 mm depth, powder coated paint, dust & vermin proof, factory fabricated with 2 mm thick CRCA sheet with front openable doors and locking arrangement comprising of following:-- Note : All connection from bus bar will be copper Insulated strip of suitable size & Insulated support. Make : ITE Gurgaon, Asian, Pride, Universal, Shalabh Make of MCCB : L&T/ Schneider / ABB / Legrand [a] Three phase and neutral Insulated bus bar copper LT 440 Volt 200 Amp [b] Digital voltmeter 96x96 mm size (0-500Volt) range with selector switch -- 01 No [c] Digital Ampmeter 96x96 mm size (0-300 A) with selector switch and CTs -- 01 No [d] Indicator lamp LED type RYB --- 01 (Set of three) [e] MCCB 160 Amp Four Pole breaking capacity 25 KA fixed magnetic and thermal release -- 01 No [f] MCCB 63 Amp Two Pole breaking capacity 25 KA fixed magnetic and thermal release -- 04 No[g]MCB 20 Amp SPN breaking capacity 10 KA as outgoing -- 01 No[h]Fixing and connection of existing Energymeter -- 04 Nos [j]Name slip holder on each compartment for identification of Accn -- 04 Nos [k]Earthing Terminal -- 02 Nos
9Wall mounted LT panel board of size 1000 mm x 1000 mm x 150 mm depth, powder coated paint, dust & vermin proof, factory fabricated with 2 mm thick CRCA sheet with front openable doors and locking arrangement comprising of following:-- Note : All connection from bus bar will be copper Insulated strip of suitable size & Insulated support. Make : ITE Gurgaon, Asian, Pride, Universal, Shalabh Make of MCCB : L&T/ Schneider / ABB / Legrand [a] Three phase and neutral Insulated bus bar copper LT 440 Volt 200 Amp [b] Digital voltmeter 96x96 mm size (0-500Volt) range with selector switch -- 01 No [c] Digital Ampmeter 96x96 mm size (0-300 A) with selector switch and CTs -- 01 No [d] Indicator lamp LED type RYB --- 01 (Set of three) [e] MCCB 160 Amp Four Pole breaking capacity 25 KA fixed magnetic and thermal release -- 01 No [f] MCCB 63 Amp Two Pole breaking capacity 25 KA fixed magnetic and thermal release -- 06 No[g]MCB 20 Amp SPN breaking capacity 10 KA as outgoing -- 01 No[h]Fixing and connection of existing Energymeter -- 04 Nos [j]Name slip holder on each compartment for identification of Accn -- 06 Nos [k]Earthing Terminal -- 02 Nos
10Heating element threaded/ screwed/ triangular or cup style type 1500 Watt ISI marked of suitable make without taking down Geyser, fixed in repair, complete all as specified and directed.
11Heating element threaded/ screwed/ triangular or cup style type 2000 Watt ISI marked of suitable make without taking down Geyser, fixed in repair, complete all as specified and directed.
12Thermostat suitable for 25 or 50 litre capacity of geyser, range 20 to 80 degree ISI marked, without taking down geyser,fixed in repair, complete all as specified and directed.
13PVC connection cotton braided heavy duty with brass union/ coupling of length 450 mm with rubber washer suitable for 15 mm dia pipe for hot or cold water connection, without taking down geyser,fixed in repair, complete all as specified and directed.
14Indicator lamp assembly with bulb suitable for geysers round or square type of approved make and quality as approved, without taking down geyser,fixed in repair, complete all as specified and directed.
15Bib taps, cast copper alloy, chromium plated, fancy type, capstan head handle, screwed down, screwedat one end, 15mm bore, fixed in repair, complete all as specified and directed.
16Stop valves, cast copper alloy, screwed down, high pressure, with capstan head handle, screwed both ends for iron pipe or for unions and fixed, chromium plated, 15 mm bore, fixed in repair,complete all as specified and directed.
17One coat painting of Geyser at site by spray gun painting (without taking down Geyser) of 25 litre capacity with synthetic enamel paint including preparation of old surface and re-writing or marking MES number,complete all as specified and directed.
18One coat painting of Geyser at site by spray gun painting (without taking down Geyser) of 50 litre capacity with synthetic enamel paint including preparation of old surface and re-writing or marking MES number,complete all as specified and directed.
19Taking down carefully existing geyser of any capacity after disconnecting all electrical and water supply connection and removing the geyser to E&M store yard for opening and dismantling the complete geyser, cleaning all the serviceable parts throughly including descaling the geyser, completely replacing the defective/ wornout parts/ material including preparing the inventory for each geyser separately in presence of Engineer-in-Charge, reassembling the geyser testing for proper smooth functioning, including transporting to original location where re-fixing the same in position and reconnecting the geyser with electric and water supply lineand testing complete byEngineer-in-Charge, complete all as specified and directed. Note: (a) Spare part required for replacement shall be measured and paid separately as supply only under items in Sl No. 21 to 29. (b) Unit rate quoted shall be deemed to include any minor i.e. nuts, bolts, lugs, etc. (c) Geyser shall be repaired within 5 days from the day of taking down. (d) Delay in repair and refixing after 5 days, a sum of Rs 1000 per geyser shall be levied upon contractor and deduction from contractor payment.
20Repair to leakage of inner tank 25/50 litre capacity geyser by brazing or soldering, including cutting of nut, bolt, washer etc, as required with gas welding cutter and provinding new nut, bolt, washer etc including testing of leakage of tanks,complete all as specified and directed.
21Supply only Inner tank made of MS 1.6 mm thick suitable for 25 litre capacity geyser, complete all as specified and directed.
22Supply only Inner tank made of MS 1.6 mm thick suitable for 50 litre capacity geyser, complete all as specified and directed.
23Supply only Vent assembly suitable for 25 litre capacity geyser, complete all as specified and directed.
24Supply only Vent assembly suitable for 50 litre capacity geyser, complete all as specified and directed.
25Supply only heating element 1500 Watt of any type adjusted in geyser, complete all as specified and directed.
26Supply only heating element 2000 Watt of any type adjusted in geyser, complete all as specified and directed.
27Supply only outer body of geyser made of 1.25 mm thick MS sheet suitablefor 25 litre capacity geyser, complete all as specified and directed.
28Supply only outer body of geyser made of 1.25 mm thick MS sheet suitablefor 50 litre capacity geyser, complete all as specified and directed.
29Supply only thermostat assembly suitable for 25 or 50 litre capacity of geyser, range 20 to 80 degree ISI marked,complete all as specified and directed.
30Dismantling solar water heating system panel of 200 litres capacity, any make and type by removing the glass panel carefully and refixing it after cleaning dust, cleaning the water collector tubes and aluminium foil including descaling the existing hot water storage tank of any capacity and replacement of rock wool, complete all as specified and directed.
31Glass panel rubber beading in replacement as per sample approval in office, complete all as specified and directed.
32Thermostat suitable for solar/ electric water heater of any capacity, 6"11" long, fixed in replacement, complete all as specified and directed.
33Gun metal globe or gate valve, 15mm bore,, fixed in replacement, complete all as specified and directed.
34Non return valve 15mm dia made of bronze ISI marked heavy duty,fixed in repair, complete all as specified and directed.
35Zebra fastener of size 12x100 mm, fixed in repair, complete all as specified and directed.
36Bottom cover for geyser in two pieces made of GI sheet in required/ existing size and shape suitable for 25 litres capacity geyser including painting of two coats synthetic enamel paint over a coat of primer to match the existing,fixed in replacement, complete all as specified and directed.
37Bottom cover for geyser in two pieces made of GI sheet in required/ existing size and shape suitable for 50 litres capacity geyser including painting of two coats synthetic enamel paint over a coat of primer to match the existing,fixed in replacement, complete all as specified and directed.
38Laying/ fitting glass wool after removing the existing unserviceable glass wool in between the inner and outer container of geyser of any capacity and make,complete all as specified and directed.
39Flexible copper lead 3 core of size 40/0.0076/2.5 sqmm, 1100 volt and making electric connection in geyser, fixed in repair,complete all as specified and directed.
40Plug top of 15/16 Amps, 230 Volt capacity, three pin, fixed In repair,complete all as specified and directed. Make: Anchor/ Cona/ SSK
41Switch piano flush type single pole one way 15/16 Amps flush type, fixed In repair, complete all as spicified & directed. Make: Anchor/ Cona/ SSK
42Piano type socket, 2 in 1, 5/15 Amps, 230 V capacity, fixed In repair, complete all as spicified & directed.
43Plug top of 20 Amp capacity, fixed In repair, complete all as spicified & directed.
44MCB SP, 32 Amp capacity, 240 Volt, conforming to "B" curve, 10KA breaking capacity and making connections for separate geyser circuit from main distribution board to geyser socket, fixed in repair, complete all as specified and directed. Make: ABB/ L&T/ Legrand/ SCHNEIDER
45Flat plate collector panel for solar water heater of size 1000x2000 mm complete with copper tubing, tuffend glass, rubber beeding, inlet and outlet water connections of capacity 100 LPD ISI marked including taking down old unserviceable, fixed in repair, complete all as specified and directed. Make :V Guard / inter Solar System/Tata BP / Kotak Urza
46Tuffend glass suitable for flat plate collector panel of size 1000x2000 mm complete with rubber beeding after removing the existing broken glass carefully and cleaning, fixed in replacement, completely all as specified and directed. Make :- V Guard /Inter Solar system/ Tata BP / Kotak Urza
47Repair and servicing of V guard 200 LPD or any capacity or make including descaling and cleaning of tubes complete all as specified and directed.
48Single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with & including one number MCB SP 20/25 Amps complete all as specified & directed.
49Spring loaded air release safety valve made of brass as per existing shape and size of approved make,fixed in replacement, complete all as specified and directed.
50Solar water heater storage tank of capacity 200 ltr with MS stand of strandard size, inletoutlet, over flow water pipe connections complete with nuts and bolts of suitable size and PCC work in 1:2:4 ratio as required at site including taking down old unserviceable, fixed in replacement complete all as specified and directed. Make -V Guard/inter solar system/Tata BP / Kotak Urza
51SPN DB, double door, 8 way, 230 Volts complete all as specified and directed. Make : Indoasian/ Havells/Legrand
52VTPN DB, double door, 4 way, 415 Volts suitable for MCCB upto 125 A, insulated busbar assembly and neutral bar complete with IP-43 protection all as specified and directed. Make : Indoasian/ Havells/ Legrand
53MCB TPN, 415 Volts, 63 Amps complete all as specified and directed. Make : Indoasian/ Havells/Legrand
54MCB TPN, 415 Volts, 100 Amps complete all as specified and directed. Make : Indoasian/ Havells/Legrand
55MCCB, TP, 125 Amps suitable for VTPN complete all as specified and directed. Make : Indoasian/ Havells/Legrand
56MCB SPN, 230 Volts, 32 Amps complete all as specified and directed. Make : Indoasian/ Havells/Legrand
57Periodicalservicing of diesel engine driven Gen set 3 phase 415 volts 50 c/s AC supply by cleaning thoroughly and replacing fuel filters ,air filters, oil filtersdraining out engine oil etc. and replacing with new oil, tightening of all gaskets , connection of battery terminals, electric cable connections foundation bolts, coupling bolts etc includingtest running and tappet setting of alternator by checking and setting of voltage and frequency complete all as specified and directed. MAKE OF DG SET : Kirloskar/ Crompton greaves/Cummins. Make of filters : kirloskar/CG/Fleet guard/MICO Note:Engine oil, Fuel filters, Air filters, oil filtersreplaced will be measured and paid separately under respective item ofsch "A" . forfollowingcapacities of DG set
58(a) 320 KVA DG SET
59(b) 160KVA DG SET
60(c) 100 KVA DG SET
61(d) 63/62.5 KVA DG SET
62(e) 40/50 KVA DG SET
63(f) 25/30 KVA DG SET
64(g) 18/20KVA DG SET
65Maintenance free batterywith initiallychargedcapacity 180 AH , 12 Volt, fixed in replacement, complete all as specified and as directed. Make :- Exide/Amron
66Maintenance free batterywith initiallychargedcapacity 150 AH , 12 Volt, fixed in replacement,complete all as specified and as directed. Make :- Exide/Amron
67Maintenance free batterywith initiallychargedcapacity 90 AH , 12 Volt, fixed in replacement, complete all as specified and as directed. Make :- Exide/Amron
68Radiator of 320 KVA DG Setwater cooled of Kirloskar make with coppertubings including replacement of connected items such as inlet & outlet rubber hoses & all other connected items, fixed in replacement, complete all as specified and as directed.
69Replacement of UNSV radiatorhose pipeset complete as per sample of D G set of following capacity
70(a) 320 KVA DG SET, Make: Greaves Cat Part No P21108610044
71(b) 160KVA DG SET, Make: Greaves Cat Part No P21108610044
72(c) 100 KVA DG SET, Make: Greaves Cat Part No P21108610044
73(d) 63/62.5 KVA DG SET, Make: Greaves Cat Part No P21108610044
74(e) 40/50 KVA DG SET, Make: Greaves Cat Part No P21108610044
75(f) 25/30 KVA DG SET, Make: Greaves Cat Part No P21108610044
76(g) 18/20KVA DG SET, Make: Greaves Cat Part No P21108610044
77Replacement of UNSV fan belts as per sample for DG sets of following capacity. MAKE: Fenner/ Grip/ Dunlop/Kirloskar
78(a) Fan belt for 320 KVA DGSet, Make: Fenner Cat Part No02.071.01.00
79(b) Fan belt for 160KVA DGSet, Make: Fenner Cat Part No02.1266.01.00
80(c)Fan belt for 100 KVA DGSet, Make: Fenner Cat Part No02.1266.01.00
81(d) Fan belt for 63/62.5 KVA DGSet,Make: Fenner Cat Part No02.1266.01.00
82(e) Fan belt for 40/50KVA DGSet,Make: Fenner Cat Part No02.1266.01.00
83(f) Fan belt for 25/30KVA DGSet,Make: Fenner Cat Part No02.542.02.00
84(g) Fan belt for 18/20 KVA DGSet,Make: Fenner Cat Part No02.637.01.00
85Replacement of stranded copper conductor battery lead for 24 volts D C grade red for (+)ve terminal and black for (-)ve terminal fitted with battery terminal at one end & battery lug at other end complete length 1.5 mtr, complete all as specified and directed.
86Cleaning of radiator by cleaning agent / Radiwash (make:fleetguard/coolguard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site , soldering / brazing,testing for any leakage , remounting to its original position as per entire satisfaction of Engr - in-charge for following capacity of DG Set.
87(a) 320 KVA DG SET
88(b) 160KVA DG SET
89(c) 100 KVA DG SET
90(d) 63/62.5 KVA DG SET
91(e) 40/50 KVA DG SET
92(f) 25/30 KVA DG SET
93(g) 18/20KVA DG SET
94Replacement of set of hose clips for DG sets of following capacity
95(a) 320 KVA DG SET
96(b) 160KVA DG SET
97(c) 100 KVA DG SET
98(d) 63/62.5 KVA DG SET
99(e) 40/50 KVA DG SET
100(f) 25/30 KVA DG SET
101(g) 18/20KVA DG SET
102Coolant radicool SFO premix of Castrol or techno-commercially equivalent of Shell/volvoline,complete all as specified and directed.
103Drain out the old used engine oil from sump of dg sets& cleaning & refilling with new engine oil 15 W 40 up to required level including topup, complete all as specified and directed. Make : Castrol/ HP or equivalent of shell
104Replacement of defective self starter assembly by new self starter assembly 12/24 volts, complete all as specified and directed. Make: lucas Cat Part No 03.034.101 or techno-commercially equivalent in Bosch
105Replacement of defective self alternator assembly by new self starter assembly 12/24 volts, complete all as specified and directed. Make: lucas Cat Part No 03.130.01 or techno-commercially equivaloent in Bosch/PMG
106Replacement of PCB card Procom R E L-7-1.0 for 160/100 KVAAMF pannel, complete all as specified and directed. Make: OSRAM Cat Part No 03.963.66
107Replacement coil Relay-24 volts,5 Amp 240 volt AC 5Amp 30 volts DC model HJQ 22 F –VZ of make YOI Cat Part No 03.963.76 or techno-commercially equivalent inSiemens for 160/100KVA AMF pannel, complete all as specified and directed.
108Replacement of timer switch0 to 80 seconds, Make : Asian/ Ticnner, for160/100KVA AMF pannel, complete all as specified and directed.
109Servicing of DG set 160 KVA AMF panel,setting of time delay switch ,tightening of all electrical incoming & outgoingconnections including replacement of cable lugs & adjustment of solenoid switches & Relays, complete all as specified and directed.
110M&L for servicing of DG set 100 KVA AMF panel,setting of time delay switch ,tightening of all electrical incoming & outgoingconnections including replacement of cable lugs & adjustment of solenoid switches & Relays, complete all as specified and directed.
111Supplying, installation, testing and commissioning of Electronic battery charging setsuitable for charging batteries12/24 V, 10/12Amps complete with meter equipments, selector switch with required size of copper wire up to required lengthand 1No. 3 pin plug top 5 Amps complete all as specified (in repairs). Make: NHL Cat Part No 02.945.22
112Painting ofGenerating set of capacity100KVA to 320KVA complete in existing colour with twocoat of synthetic enamelled paint byspray machineover one coat of primerafter preparation of surfaces installedat Hisar Mil Stncomplete all as specified and as directed.
113Painting of Generating set of capacity18KVA to 63KVA complete in existing colour with twocoat of synthetic enamelled paint with spray machineover one coat of primerafter preparation of surfaces installed atwestern & eastern pocket drainage pump House complete all as specified and as directed.
114Supply and replacing in repair Euroload four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 100 Amps, 415 Volts complete all as specified and directed. Make: Havells/ Indoasian/ C&S
115Supply and replacing in repair Euroload four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 200 Amps,415 Volts complete all as specified and directed. Make: Havells/ Indoasian/ C&S
116Supply and replacing in repair Euroload four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 400 Amps, 415 Volts complete all as specified and directed. Make: Havells/ Indoasian/ C&S
117Supply only Diesel Filter suitable for 18 KVA to 100 KVA DG set, complete all as specified and directed. Make - Kirloskar Cat Part No 02.102.03 or techno-commercially equivalent in CG/KG/Cummins
118Supply only Diesel Filter suitable for 160KVA to 320KVA DG set , complete all as specified and directed. Make - KirloskarCat Part No 02.102.03 or techno-commercially equivalent in CG/KG/Cummins
119Supply onlyLub Oil filter suitable for 18 KVA to 100 KVA DG set, complete all as specified and directed. Make - Kirloskar Cat Part No 03.040.08 or techno-commercially equivalent in CG/KG/Cummins
120Supply only Lub Oil Filter suitable for 160KVA to 320KVA DG set, complete all as specified and directed. Make - Kirloskar Cat Part No 03.040.08 or techno-commercially equivalent in CG/KG/Cummins
121Supply onlyAirfilter suitable for 18 KVA to 100 KVA DG set, complete all as specified and directed. Make - Kirloskar Cat Part No 30.0610.20 or techno-commercially equivalent in CG/KG/Cummins
122Supply only Air Filter suitable for 160KVA to 320KVA DG set,complete all as specified and directed. Make - Kirloskar Cat Part No 30.0610.20 or techno-commercially equivalent in CG/KG/Cummins
123Spare parts & accessories of original make for repair of DG set under serial items No 1(iv) here-in-before all as directed by Engr-in-Charge :- 03 Nos DG sets Notes :- All spares & accessories shall be fixed in the DG set only after prior inspection & Approval of Engineer-in-Charge for which these shall be produced by the contractor at store yard of AGE E/M Old Cantt
124Kit Fuel filter, Make: Kirloskar Cat Part No 3H.123.01.00
125KitLub oil filter, Make: Kirloskar Cat Part No 064.36.01.00
126Kit bypass filter, Make: Kirloskar Cat Part No 3H.133.01.00
127Kit Air cleaner, Make: Kirloskar Cat Part No 4H11.98.02
128Air filter, Make: Kirloskar Cat Part No 4H11.98.01
129Upper Gasket set (Cylinder head), Make: Kirloskar Cat Part No 4H.007.24.00
130Valve exhaust, Make: Kirloskar Cat Part No 4H.007.400.00
131Valve inlet, Make: Kirloskar Cat Part No 4H.007.300.00
132Valve seat Exhaust, Make: Kirloskar Cat Part No 4H.007.03.00
133Valve seat Inlet, Make: Kirloskar Cat Part No 4H.007.04.00
134Guide valve, Make: Kirloskar Cat Part No 4H.007.020.00
135Collet Valve, Make: Kirloskar Cat Part No 02.0024.01.0.00
136Spring valve, Make: Kirloskar Cat Part No 50540/09X016
137Kit turbo charging, Make: Kirloskar Cat Part No 6H.029.10.000
138Collar thrust, Make: Kirloskar Cat Part No 6H.001.03.000
139Kit injector, Make: Kirloskar Cat Part No 4H.154.10.000(MICO)
140Kit Piston and ring set, Make: Kirloskar Cat Part No 4H.180.01.000/ ZH.0009.02.0.00
141Kit Cylinder liner, Make: Kirloskar Cat Part No 2H.008.07.0.00
142Kit Sump Gasket, Make: Kirloskar Cat Part No 06.074.20.0.00
143Gear pump assembly (Fuel pump FIP), Make: Kirloskar Cat Part No 2H.011.01.0.00
144Weight & carrier
145Barrel sleave, ,Make: Kirloskar Cat Part No 02.035.07.000
146Gasket Set, Make: Kirloskar Cat Part No 6H
147Sexen filter
148Governor Pressure vlave (Hydraulic Governor)
149Weight and Carrier
150Gear assembly, Make: Kirloskar Cat Part No 6H.020.01.0.00
151Ball bearing, Make: Kirloskar Cat Part No 6305
152Head gasket, Make: Kirloskar Cat Part No 6H.02.001
153Nozzle
154Block, Make: Kirloskar Cat Part No 6H.001.25.0.00
155Liner, Make: Kirloskar Cat Part No 2H.008.01.0.00
156Battery terminal,
157Packing Kit, Make: Kirloskar Cat Part No 4H.0.87.40.0
158Crank, Make: Kirloskar Cat Part No 6H.0002.00.00
159Main bearing, Make: Kirloskar Cat Part No 6H.001.06.0.00
160CR bearing, Make: Kirloskar Cat Part No BO.73.400
161Came bush, Make: Kirloskar Cat Part No 03.001.04.0.00
162Connecting Rod, Make: Kirloskar Cat Part No 4H.182.10.0.00
163Rod balancing
164Bush, Make: Kirloskar Cat Part No 4H.182.02.000
165Third washer, Make: Kirloskar Cat Part No 6H.001.03.0.00
166Valve seal, Make: Kirloskar Cat Part No 06.631.02.000
167Spare parts & accessories of original make for repair of DG set under serial items No 1(vi) here-in-before all as directed by Engr-in-Charge :- 01 Nos DG sets Notes :- All spares & accessories shall be fixed in the DG set only after prior inspection & Approval of Engineer-in-Charge for which these shall be produced by the contractor at store yard of AGE E/M Old Cantt
168Kit Fuel filter, Make: Kirloskar Cat Part No 3R.123.01.00
169KitLub oil filter, Make: Kirloskar Cat Part No 034.36.01.00
170Kit bypass filter, Make: Kirloskar Cat Part No 3R.133.01.00
171Kit Air cleaner, Make: Kirloskar Cat Part No 3R1198.02.00
172Air filter, Make: Kirloskar Cat Part No 4R.11.98.01.00
173Upper Gasket set (Cylinder head), Make: Kirloskar Cat Part No 3R.007.24.00
174Valve exhaust, Make: Kirloskar Cat Part No 3R.007.400.00
175Valve inlet, Make: Kirloskar Cat Part No 3R.007.300.00
176Valve seat Exhaust, Make: Kirloskar Cat Part No 3R.007.03.00
177Valve seat Inlet, Make: Kirloskar Cat Part No 3R.007.04.00
178Guide valve, Make: Kirloskar Cat Part No 3R.007.020.00
179Collet Valve, Make: Kirloskar Cat Part No 03.0024.01.0.00
180Spring valve, Make: Kirloskar Cat Part No 50540/09X016
181Kit turbo charging, Make: Kirloskar Cat Part No 3R.029.10.000
182Collar thrust Make: Kirloskar Cat Part No 3R.001.03.000
183Kit injector repair, Make: Kirloskar Cat Part No 3R.154.10.0.00(MICO)
184Kit Piston and ring set, Make: Kirloskar Cat Part No 3R.180.01.000/ ZH.0009.02.0.00
185Kit Cylinder liner, Make: Kirloskar Cat Part No 3R.008.07.0.00
186Kit Sump Gasket, Make: Kirloskar Cat Part No 03.074.20.0.00
187Gear pump assembly (Fuel pump FIP), Make: Kirloskar Cat Part No 3R.011.01.0.00
188Weight & carrier
189Barrel sleave, Make: Kirloskar Cat Part No 03.035.07.0000
190Gasket Set, Make: Kirloskar Cat Part No 3R
191Sexen filter
192Governor Pressure vlave (Hydraulic Governor)
193Weight & carrier
194Gear assembly, Make: Kirloskar Cat Part No 3R.020.01.0.00
195Ball bearing, Make: Kirloskar Cat Part No 3305
196Dismantling ofDG Set Alternator of cap 63/62.5 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as specified and directed.
197Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, Nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete all as specified and directed.
198Repairing ofarmature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete.
199Supply and replacingBall bearing at DE (Driven End) side of No.6310 Make-NBC/SKF-01 No
200Supply and replacing rectifier Diod.
201Supply and replacing AVR (Automatic Voltage Regulator).
202Supply and replacing connetion plate of suitable size.
203Dismantling ofDG Set Alternator of cap 100/160KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as specified and direted.
204Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, Nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete all as specified and directed.
205Repairing ofarmature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete.
206Supply and replacingBall bearing at DE (Driven End) side of No.6310 /6311/6312/6314 Make-NBC/SKF-01 No
207Supply and replacing rectifier Diod.
208Supply and replacing AVR (Automatic Voltage Regulator) TVR-20
209Supply and replacing connetion plate of suitable size.
210Dismantling ofDG Set Alternator of cap 25/30/40 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as specified and directed.
211Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, Nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete all as specifed and directed.
212Repairing ofarmature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete all as specified and directed.
213Supply and replacingBall bearing at DE (Driven End) side of No.6310 /6311/6312/6314 complete all as specified and directed. Make-NBC/SKF
214Supply and replacing rectifier Diod.
215Supply and replacing AVR (Automatic Voltage Regulator).
216Supply and replacing connetion plate of suitable size.
217MCCB 100 Amps, 415 Volts, 4 Pole, breaking capacity 16/25 KA, ISI Marked, Fixtype, fixed in repair, complete all as specified and directed. Make- C&S/ L&T/Indo-Asian/Havells
218MCCB 200 Amps, 415 Volts, 4 Pole, breaking capacity 25KA, ISI Marked, Fix/ Adjustable type, fixed in repair, complete all as specified and directed. Make- C&S/ L&T/Indo-Asian/Havells