Development Of Campus And Landscapping Work Of Govt. Polytechnic College And Ihmct At Karad, Silvassa. Development Of Campus And Landscapping Work Of Govt. Polytechnic College And Ihmct At Karad, Silvassa., UT of DNH and DD-Dadra And Nagar Haveli

Union Territory Of Dadra And Nagar Haveli has published Development Of Campus And Landscapping Work Of Govt. Polytechnic College And Ihmct At Karad, Silvassa. Development Of Campus And Landscapping Work Of Govt. Polytechnic College And Ihmct At Karad, Silvassa.. Submission Date for this Tender is 25-09-2021. Building Work Tenders in UT of DNH and DD Dadra And Nagar Haveli. Bidders can get complete Tender details and download the document.




Tender Notice

29139454
Development Of Campus And Landscapping Work Of Govt. Polytechnic College And Ihmct At Karad, Silvassa. Development Of Campus And Landscapping Work Of Govt. Polytechnic College And Ihmct At Karad, Silvassa.
Open Tender
Indian
Dadra And Nagar Haveli
UT of DNH and DD
25-09-2021

Tender Details

Development Of Campus And Landscapping Work Of Govt. Polytechnic College And Ihmct At Karad, Silvassa. Development Of Campus And Landscapping Work Of Govt. Polytechnic College And Ihmct At Karad, Silvassa.

Key Value

Document Fees
INR 1500 /-
EMD
INR 2124300.0 /-
Tender Value
INR 11.24 Crore /-

BOQ Items

Name of Work:Development of campus and landscapping work of Govt. Polytechnic college and IHMCT at Karad, Silvassa.
Sl. No. Item Description
1Providing & fixing waste bin of Capacity 120 Liters100% HDPE Virgin UV Resistant & Crack Resistant and Heavy Duty Plastic with Solid Rubberized Wheels for Smooth Operation (Big Rabbit type) as per detail including placing at location etc. Complete as approved and directed by engineer in-charge. (ISI MARK as approved by Engineer In Charge)
2SITC two-way peformance speaker with 1” dome tweeter and a 8” low frequency loudspeaker, capable of delivering a power of 70 Watt, 100V PA system with tap of 60 Watt, 30 Watt, and 15 Watt. RMS Power of 70 Watt & Max Power of 140 Watt at 16 ohms. Coverage pattern of 110° x 110°,Sensitivity (1W/1m) 89 dB, Max SPL 106 dB.(Bose/QSC/AUDAC)
3SITC mixer amplifier that runs on 100V lines and Impedance modes, Frequency Response 50hz-20Khz System Output 500W rms, Distortion <= 1%@1 kHz, S/N Radio >= 76db (Aux), 66db (Mic), Inputs USB/SD/Aux/CD/computer Mic Input 1 Mics, two zone. (JBL/STONEWATER/Audac)
4SITC Dynamic transducer type, cardioid polar pattern, frequency response 70Hz - 15KHz wired microphone. (Studio Master, Shure, AKG, Senniheiser)
52 Core speaker cable, ATC Copper conductor, PVC insulated, Cores twisted in circular form, Jacketed with PVC, CROSS SECTION AREA: 15 SQMM. (Krystal, MX, Balden, Bandridge or equivalent.)
6Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.
7Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work
8Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) In Lime Mortar.
9Dismentling steel work (High mast) including distempering and stacking the materials with all lead and lift.
10Providing material, labour, machinery for Excavation of foundation upto 1.5 m depth including sorting outandstacking of useful materials anddisposing off the excavated stuff with in/ out side the campus upto all lead to safe disposal site approved by EIC, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavated material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.
11Drilling of 200/215 mm dia bore in over burden rocky or loose collapsible / boulder strata & lowering of 175/200 mm dia UPVC /PVC / ERW casing pipe above 12 mtr up to 40 mtr depth by DTH ring etc. Complete
12Carriage charges of excavated material including upto 1.5 km lead, all lift, loading, unloading etc. complete as directed by engineer in-charge.
13Providing and laying cementconcrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
14Providing M-15 / 1:2:4 Cement Concrete for street light pole Foundation and 70% P.C.C. from bottom including Excavation for the pole of size 45 x 45 x 100 cms. Deep in below ground level with plinth of 45 cms x 45 cms (or 45 cms dia. x 45 cms) high upper ground level with necessary curing and finishing in approved manner.
15Providing and laying controlled cement concrete M.200 and curing complete including the cost of formwork but excluding cost of reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete
16Providing and laying controlled cement concrete M.200 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in (B) COLUMNS:(i) Having cross-sectional area 0.08 to 0.18 Sq.M
17Providing and laying controlled cement concrete M.200 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in(A) BEAMS :(i) Having cross-sectional area 0.05 to 0.08 Sq.M
18Providing and laying controlled cement concrete M.200 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in(A) BEAMS :(i) Having cross-sectional area 0.08 to 0.12 Sq.M
19Providing and laying controlled cement concrete M.200 and curing complete including the cost of formwork but excluding the cost of reinforcement for reinforced concrete work in (B) Walls, from top of foundation level upto floor two level
20Providing and laying controlled / Precast cement concrete M.200 and curing complete including the cost of formwork but excluding the cost of reinforcement for reinforced concrete work in (C) Slabs, landing, shelves, Balconies Lintels, Girders and Cantilever upto floor two level.
21Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level
22Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional
23Brick Work using Common Burnt Clay Building Bricks having crushing strength not less than 35 kg / Sq. cm. in superstructure above plinth level upto floor two level. In Cement Mortar 1:6 (1 Cement : 6 Fine Sand) (B)Conventional
24Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick for sitting
25Providing and laying polished kota stone slab 25mm thick in risers of steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. complete.
26Providing and laying white glazed tiles (Kajaria Ceramics Ltd, Nitco Ltd, Somany Ceramics Ltd or equivalent make) 8mm thick in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush pointing in white cement.
27P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for antiskit (upto 10 ton)
28Providing and fixing pre-cast Rubber Dye inter locking concrete block (Vyara, Universal Blocks or equivalent) 60mm thick with grade of concrete M250 pneumatic compressed by mechanically pressed and as per approved designincluding 75mm Sand layer for levelling and filling the joint with sand in proper line and level etc complete.
29Providing and fixing pre-cast concrete kerb stone (Vyara, Universal Blocks or equivalent) of grey cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade concrete as per approved design and including excavation for fixing in proper line and level, filling the joint with C:M 1:3 (1cement:3fine sand) etc complete.
30Providing and fixing Rajula stone 75mm thick 60mm x 45mm size including fixing in cement mortar as directed.
31Providing and fixing in position Natural Boulders of size as approved by Architect etc. complete
32Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
33WATERPROOFING TREATMENT: Cleaning existing Terrace Surface, Providing and LayingWaterproofing Treatment in DOUBLE LAYER to Terrace with APP (Atactic Polypropylene Polymer) Modified Pre-Fabricated Five Layer Water Proofing Membrane,HYDROSTOP of TIKIDAN make,comprising of 1st Layer of 3mm Thick and Minimum 3.5 Kg./m2 Weight Membrane HYDROSTOP 3 FGP,Upper and Bottom Surface Finished in Plastic Polyethylene Film and having Reinforcement of Fibre Glass at Core and 2nd Layer of 3mm Thick and Minimum 3.5 Kg./m2 Weight Membrane HYDROSTOP 3 PYM, Upper Surface Finished in Minerals and Bottom Surface Finished in Plastic Polyethylene Film and having Reinforcement of Non-Woven Polyester Matt at Core, including a Coat of Bitumen Primer TIKI PRIME S for Bitumen Membranes Manufactured to IS:3384 . Over the dried Primer Coat, Laying APP Membrane HYDROSTOP in DOUBLE LAYER using Butane Torch, the 1st Layer Torch Bonded to the Primed Surface followed by Torch Bonding of 2nd Layer to the First, while maintaining the Side Overlaps 100mm and End Overlaps 150mm, Sealing all Overlapsetc. complete., including treatment at all Junctions and Corners to accomodate Stresses with 300mm Wide Strip of 3mm HYDROSTOP 3 PYP and treatment over the Vertical Plane up to 200mm height above the Finished Floor level with 3mm APP Membrane HYDROSTOP 3 PYM, the Waterproofing Membrane terminated by tucking itinto the groove made on Vertical Plane, the groove sealed with Cement-Sand Mortar, etc., all complete.
34Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brickwalls for interior plastering upto floor two level and finished even and smooth in (ii)Cement mortar 1:4 (1-cement :4-sand)
35Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brickwalls for interior plastering upto floor two level and finished even and smooth in (ii)Cement mortar 1:4 (1-cement :4-sand) including finishing with a floating coat of neat cement slurry.
36Providing 20mm thick sand faced cement plaster on walls upto height 10metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.
37Providing and fixing 35 mm thick shutters for Doors, windows and clerestory windows including Indian teak wood frames 12 cm x 7 cm. size, rates including S.S. aldrop(2 Nos), S.S. handle(4 Nos), S.S. stoper(2 Nos)including anodized alluminium fixtures and fastenings including primer coat of approved quality and two coats of oil painting etc, complete. (ii) Fully Panelled.
38(ii) Providing and fixing glazed louvered glass windows and ventilators with teak wood frame 10cm. x 7cm. size including 3 coats of oil painting to wood work etc.complete. with wooden louvers plank 12mm thick, including providing & fixing Mosquito mesh shutter using Aluminium section of size 40mm x 18mm x1.29mm (of Jindal Section no:8947@ wt.of 0.456 Kg/mt) for frame and stainless steel jali.
39Applyingtwo coats of Birla (white cement based) or Asian (acrylic lapy- putty) or equivalent & two coats of primer of approved brandand manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.
40Wall painting (two coats) with plastic emulsion paint of Asian, Nerolac, Berger or equivelent make and manufacture on undecorated wall surface to give an even shade including thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
41Finishing wall with weather proof exterior emulsion paint of Asian, Nerolac, Berger or equivelent make on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials. Etc complete
42Painting two coats (excluding priming coat) of Asian, Nerolac, Berger or equivelent make on new steel and other metal surface with enamel paint, brushing, interior to give an even shade including cleaning the surface an even shade including cleaning the surface of all dirt, dust and other foreign matter.
43Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of read lead paint. (A)In beams and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip and jack rafters, purlins connected to common rafters and the like
44Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(C) 250mm
45Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low density, complete with special flange compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(G)110 mm
46Providing & laying approved makeDouble walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II) with necessary connectingaccessories of same material at required depthfor laying ofcable. below ground/ road surface for enclosing cable and back filling the same to make ground as per original. (B)90 mm dia
47Constructing Block masonary chamber for underground C.I inspection chamber and bends with stone of approved quality in C.M 1:5 R.C.C top slab 1:2:4 mix (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size ) with 8mm dia steel at 15 cm. C.C and providing and fixing precast R.C.C cover 40 x 40 x 5 mm angle frame and foundation concrete 1:5:10 inside plaster 15mm thick with a floating coat of neat cement walls and bed concrete etc. complete. Rate are also inclusive of outside plaster 15mm thick in C.M 1:3 from top of chamber and all side upto 45cm deep for multi- purpose pipe line. 455x610x450mm
48Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid.
49Labour charge for fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
50Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
51Labour charge for fxing vitreous china wash including C.P cast brass bottle trap with unions, complete including cuttinggood the walls and floors, wherever required. A) Under Counter/Counter Top Fitting
52Providing and fixing vitreous china wash including C.P cast brass bottle trap with unions, complete including cuttinggood the walls and floors, wherever required. A) Under Counter/Counter Top Fitting
53Extra over items 47 for every additional depth of 0.1M. Of part thereof beyond 450mm depth for Block masonry chamber.(III) for 445 x 610 size.
54Preparing structural design of RCC Under Ground / Partially under ground / above high ground level Reservoir 1,00,000 litres capacity as per relevant I.S.s and constructing the same, including excavation in all types of soil strata (including rock) including shoring strutting if required, for loose soil / to protect from collapse due to near by traffic load, casting 100 mm thick P.C.C. levelling course in M-10, Refilling the pit with proper soil and disposing of the surplus stuff within a lead of 50 meters. Including cement plaster in CM 1:2 with approved water proofing compound to inside water touching surface to container. Including all types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design. Providing and fixing accessories like MS / GI Ladder, CI Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail. B.B. Masonry chambers for valves. Providing and applying three coats of cement paint / snowcem to the out side face of structure. It also includes satisfactory water tightness test as per relevant I.S. code and painting name of scheme and capacity on the tank as per direction of engineer in charge. List of Indian Standards for Design of GSR / SUMP:- The structural design of GSR shall be in accordance with provisions relevant I.Ss. (1)     I.S. 3370, Part – 1 to 4, 2009 or latest revised. 1.1) I.S. 3370 part III & IV 1965 or latest revised (2)     I.S. 456 – 2000 or latest revised. (3)     I.S. 1893 – 2000 – 1984 or latest revised. (4)     I.S. 875, Part – 1to 3, 1987 or latest revised.
55Preparing structural design of RCC Under Ground / Partially under ground / above high ground level Reservoir 2,00,000 litres capacity as per relevant I.S.s and constructing the same, including excavation in all types of soil strata (including rock) including shoring strutting if required, for loose soil / to protect from collapse due to near by traffic load, casting 100 mm thick P.C.C. levelling course in M-10, Refilling the pit with proper soil and disposing of the surplus stuff within a lead of 50 meters. Including cement plaster in CM 1:2 with approved water proofing compound to inside water touching surface to container. Including all types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design. Providing and fixing accessories like MS / GI Ladder, CI Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail. B.B. Masonry chambers for valves. Providing and applying three coats of cement paint / snowcem to the out side face of structure. It also includes satisfactory water tightness test as per relevant I.S. code and painting name of scheme and capacity on the tank as per direction of engineer in charge. List of Indian Standards for Design of GSR / SUMP:- The structural design of GSR shall be in accordance with provisions relevant I.Ss. (1)     I.S. 3370, Part – 1 to 4, 2009 or latest revised. 1.1) I.S. 3370 part III & IV 1965 or latest revised (2)     I.S. 456 – 2000 or latest revised. (3)     I.S. 1893 – 2000 – 1984 or latest revised. (4)     I.S. 875, Part – 1to 3, 1987 or latest revised.
56Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of 450 C. The outlet temp. of the water should drop by 150C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating, coil, thermostats, relay etc.complete with necessary inlet & outlet connection. The body of water cooler will be made from Stainless Steel.
57Removing and scraping of old deteriorated plaster of any thickness from wall / R.C.C member including stacking of serviceable material and disposal of unserviceable from site of work with all lead and lift
58Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(i) G.I.sheet roofing.
59Clearing and grubbing road land including uprooting rank vegetation grass bushes, shrubs, sapling and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials (A) By manual means in area of light jungle
60Providing material, labour, machinery for Excavation of foundation 1.5 m to 3.00 mt depth including sorting outandstacking of useful materials anddisposing off the excavated stuff with in/ out side the campus upto all lead to safe disposal site approved by EIC, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavated material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.
61Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete.
62Supplying and stacking of good garden earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
63Rolling of earthwork in layers with power roller including filling in depressions which occur during the process.
64Providing and laying controlled cement concrete M.200 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for R.C.C. work in (B) COLUMNS:(i) Having cross-sectional area 0.05 to 0.08 Sq.M
65Providing and laying controlled cement concrete work M200 and curing complete including the cost of form work and excluding the cost of reinforcement of reinforced concrete work in : slabs, landing, shelves, balconies etc
66Providing and laying controlled cement concrete work M200 and curing complete including the cost of form work and excluding the cost of reinforcement of reinforced concrete work in : walls from top of foundation.
67Ploughing land upto 20 cm to 30 cm depth and levelling the land by using Tractor.
68Providing 15mm thick cement plaster in single coat on Rough (Similar)side of Ceiling or soffits for interior plastering upto floor two level and finished even and smooth in (ii)Cement mortar 1:4 (1-cement :4-sand) including finishing with a floating coat of neat cement slurry.
69Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and smooth in (ii)Cement mortar 1:4 (1-cement :4-sand) including finishing with a floating coat of neat cementslurry
70Providing 20mm thick sand faced cement plaster on walls upto height 10metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) including providing and fixing chicken mesh jaliat all RCC and brickwork joints including necessary materials as directed by engineer in-charge etc. complete.
71Providing & laying weep hole in Abutments, and returns by using A.C. pipe of 100mm including laying in proper grade and jointing the completed as per detailed specification.
72Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(C) 250mm
73Box cutting the road surface to proper slope and camber for making a base for road work including removing the excavated stuff and depositing on the road side slope as directed upto 50Mt.lead.
74Rolling and consolidation of soling including filling in depression which occur during the process, with power roler 8 tonne to 12 tonne.
75Construction of Granular Sub Base (GSB) by providing coarse graded material of any grade, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, including all material, labour, machinery with all leads and lifts etc. complete as per MORTH specification and as directed by Engineer in charge.
76Providing material and labour for, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tripper to site, laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.
77Providing, Applying, Evenly Priming Tack Coat on WMM surface with Emulsion SS1 @ 9 Kg/10 M2 including cost asphalt, heating and the cost of spraying uniformly complete as directed.
78Providing and Laying compacted 50mm thick dense graded bituminious macadam (DBM) Grade-2 in single layer using 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour, tack coat at the rate of 2.5 Kg / 10 m2 in each using crushed aggregates of specified grading premixed with bituminious content @ 4.5% (VG-40) by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control with minimum road width or as directed by Engineer in charge to the required grade, level and alignment, rolling with smooth wheeled vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification etc complete in all respects. The agency shall have to get the mix design done from approved laboratory and submit to the Engineer in charge for Approval. If the asphalt (bituminious) content is more than above, the agency shall have to bear the cost of additional asphalt. The payment shall be done on the permissible field density achieved on the ite instead of density derieved in the mix design. (Assume density = 2.40 gms / cm3)
79Providing and laying 50 mm ThickBituminous Concrete using crushed stone aggregate BT chips as per required gradation and using emulsion asphalt as a tack coat @ 2.5 kg / 10 sq.m and the VG-40 grade asphalt at 5.40 % (i.e. 54 kg/MT) by total weight of mix hot laid process using drum mix plant including heating and mixing asphalt & materials by drum mix process transporting the mix and laying by paver finisher including consolidation with vibratory roller & PTR including cost of material labour machinary equipment and fuel, oil. Lubricant for plant and machinary using contractor"s own plant and machinanes etc complete. The agency shall have to get the mix design done from approved laboratory and submit to the Engineer in charge for approval. If the asphalt (bituminous) content is more than above, the agency shall have to bear the cost of additional asphalt. The payment shall be done on the permissible field density achieved on the site instead of density derieved in the mix design. [Assume Density=2.45 gms/cm3]
80Road making with hot applied thermoplastic paints with reflectorising glass beads on bitumin. Providing and laying a hot applied thermoplastic compound 2.5 mm thik including reflectorised glass beads at rate 250 gms per sqm area, thickness of 2.5 mm is excluding of surface applied glass beads as per IRC : 35-2015. The finished surface to be level, uniform and free form streaks and holes. Zebra patta/ bump patta/ lane/ center/line/edge line/ cut patta. The white colour marking shoud provide liminance coefficient on cement road shall be min. 130 mcd/ m2/ lux and asphalt road shall be min. 100 mcd/m2/lux during the service life during the day time. The marking should meet the performance criteria for night time refectivity, wet reflectivity and skid resistance as mentioned in the section-15 of IRC: 35-2015. Warranty for retro reflectivity shall be 2 years.
81Cat eye/ road stud/ RPM: - Supplying of MouldedTwin Shanks Raised Pavement Markers made of Polycarbonate and ABS moulded body and reflective panels with Micro Prismatic Lens (No glass bead lens) Capable of providing total internal reflection of the lights entering the lens face and shall support a load of 13635 kgs. tested in accordance to ASTN D 4280 Type - H and complying to specification of category A of MORTH circuler No. RW/NH/33023/10-97-Do III Dt. 11/056/1997. The height, width and length shall not exceed 20 mm, 130 mm and 130 mm and with min. reflective area of 13 sqcm on each side and the slope to the base shall be 35+/-5 degree. The strength of detachment of the integrated cylinderical shanks ( of diameter not less than 19+/-2 mm and height 30+/-2 mm ) from the body is to be a min. value of 500 kgs. fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer"s recommendation and colour of the marker should be as per the IRC : 35 - 2015.
82Providing and fixing acrylic Name plate of required size on Room with lettering etc. complete as per instruction of engineer in charge including all labour and material etc. complete
83Providing and fixing PRE ENGINEERED ROOF comprising of galvalume sheets, steel structural trusses, braces, framings etc. incorporating skylights, evaces, gutters etc. and other ancillary components in desired slopes and shapes, with sound proof and Thermal insulation arrangement. Following are the principal components and specs. 1) Built-up component of ASTM A572M Grade 50 Type 1 of yield strength of 345MPa. 2) Hot rolled tubes as per IS 1161 of yield strength of 250 Mpa. Designing, fabrication, supply and erection of Hot rolled members like ISMB, ISMC, tube sections and pipe sections etc. with all labour, consumable, Plant, Machinery etc. complete. 3) Exterior roof panel of ASTM A792 M Grade 342 class 1 coating AZ150 (G550) of yield strength 550 Mpa. 4) Cold formed of ASTM A653 M Grade 340 class 1 coating Z120-GI of yield strength 340 Mpa. 5) X-Bracing rods as per IS 2062 of yield strength 250 Mpa., X-Bracing sq/rectangle hollow sections as per IS 4923 of yield strength of 310 Mpa. And X-Bracing angles as per IS 2062 of yield strength of 250 Mpa. 6) Anchor bolts as per IS 2062- UNPAINTED of yield strength 240 Mpa. 7) High strength bolts as per IS 3757 Black Finished of yield strength Gr. 8.8, 8) Connection Bolts as per IS 1363 Yellow Chrome of yield strength Gr. 4.6, Surface preparation include Wire Brush Cleaning and Paint Application i.e., 1 coat of Primer and 2 coat of paint of approved shade. Also on the steel structure, paint one coat of red oxide (35 micron) & two coats of synthetic enamel paint (25 micron each). In this PEB Structure Size, quality/grade as specified above shall be strictly adhered to no separate payment in terms of tonne will be paid. The detailed design of the PEB frame structure will be verified and approved by the authority appointed by the client.
84Providing and Fixing Sculpture of nearly 1.20 mt X 0.60 mt X 0.60 mt size of metal material and as per architect design as directed by engineer in-charge.
85Providing and Fixing Sculpture reilif work of nearly 6.00 mt X 6.00 mt size on metal sheet and as per architect design as directed by engineer in-charge.
86Providing and Fixing tensile structure of modular, prefab and panel build type of Steel and PVC material use in seating arrangement, parking and building entrance, having aluminium, galvanized, or steel pole material and frame should be steel material easily assembled, and eco Friendly waterproof material, weight (Gsm) 502, 602, 702 , Tensile Strength 300 APH of any colour, plain surface of surge Ferrari brand with 10 years warranty, including fitting, labour,fixtures, fastening, and all type of equipments, supporting poles, primer, painting etc. complete as directed by engineer in charge.
87Supply of Decorative Luminaires BIS approved ( alongwith BIS certification of model streetlightfamily confirming to IS 10322 /IEC60598 & LM79parameters as per tender specs) for Urban lighting, body made of painted spun aluminium with Top spun aluminium minimum thickness of 1.5 mm,Dia should not exceed 435mm and height should not exceed 265 mm ,weight should not be less than 1.28 kg and Lowerspun aluminium ofminimum thickness of1.5mm,dia should not exceed 595 mm ,height should not exceed 40 mm and weight should not be less than 0.9 kg.Body of the fixture must be in two parts and fixture opening of the fixture is from front side for the ease of operation . The protector is made of single piece injection mouldedpolycarbonate with thickness of 3 mm and weight should not exceed 1 kg.Diamteter and height of the protector should not be more than 320 mm..Protector grade with UV resistant IK 09 ( Confirm byIS10322 reportfrom Third party NABL approved lab) Protector holding aluminium ringwith a thickness of 3 mm with a minimum diameter of 420 mm and weight more than 0.3 kg. ringPermanently sealed optical compartment with IP66 protection.( Confirmed byIS10322/IEC60598 report from Third party NABL approvedlab). Luminaire offers tool free access to gear compartment with IP65 protection( Confirmed by IS10322 report from Third party NABL approved lab) Foam gasket for control gear assembly .Minimum Luminairedimensions of 545* 550 mm . Luminaire can be installed as a suspended luminaire with1 inch BSP stainless steelpipe with 2 chuck nutsis provided..The luminaire must be provided with Air vent plug in optical compartment.The luminaire is equipped with PC lenses with wide photometry for increased pole spacing. The luminaire is provided with disconnector to avoid electrical shocks. Easy access to control gear compartment by opening special draw latch with zinc plated materialand hingekind of arrangement. Fixture is having external surge protection of 10KV. Electronic driver is having power factor>0.90*, THD<15*%, CRI>80 and input voltage range from 120-227V AC at 50Hz.Minimum lumen 7200 lumen (Confirmed by LM79 report from Third party NABL approved lab) in CCT range of 4000 as per ANSI. presented with Dialux report and IES file of the luminaire System life of 50000 burning hours with 70% of initial lumens maintained. Luminaire is suitable for operating temperature (Ta) from -20° to 50°C. Driver can withstand 320V AC for 48 hours and 440 V AC for 8 hours. WATT-60W. Make : Keselec/Bega /Rosa
88Supply of Decorative Luminaires BIS approved ( alongwith BIS certification of model streetlightfamily confirming to IS 10322/IEC60598 & LM79parameters as per tender specs) for Urban lighting, body made of painted spun aluminium with Top spun aluminium minimum thickness of 1.5 mm,Dia should not exceed 435mm and height should not exceed 265 mm ,weight should not be less than 1.28 kg and Lowerspun aluminium ofminimum thickness of1.5mm,dia should not exceed 595 mm ,height should not exceed 40 mm and weight should not be less than 0.9 kg.Body of the fixture must be in two parts and fixture opening of the fixture is from front side for the ease of operation . The protector is made of single piece injection mouldedpolycarbonate with thickness of 3 mm and weight should not exceed 1 kg.Diamteter and height of the protector should not be more than 320 mm..Protector grade with UV resistant IK 09 ( Confirm byIS10322/IEC60598 reportfrom Third party NABL approved lab) Protector holding ringwith a thickness of 3 mm with a minimum diameter of 420 mm and weight more than 0.3 kg. ringPermanently sealed optical compartment with IP66 protection.( Confirmed byIS10322/IEC60598 report from Third party NABL approvedlab). Luminaire offers tool free access to gear compartment with IP65 protection( Confirmed by IS10322/IEC60598 report from Third party NABL approved lab) Foam gasket for control gear assembly Minimum Luminairedimensions of 545* 550 mm . Luminaire can be installed as a suspended luminaire with1 inch BSP stainless steelpipe with 2 chuck nutsis provided..The luminaire must be provided with Air vent plug in optical compartment.The luminaire is equipped with PC lenses with wide photometry for increased pole spacing. The luminaire is provided with disconnector to avoid electrical shocks. Easy access to control gear compartment by opening special draw latch with zinc plated materialand hingekind of arrangement. Fixture is having external surge protection of 10KV. Electronic driver is having power factor>0.90*, THD<15*%, CRI>80 and input voltage range from 120-227V AC at 50Hz.Minimum lumen 13200 lumen (Confirmed by LM79 report from Third party NABL approved lab) in CCT range of 4000 as per ANSI. presented with Dialux report and IES file of the luminaire System life of 50000 burning hours with 70% of initial lumens maintained. Luminaire is suitable for operating temperature (Ta) from -20° to 50°C. Driver can withstand 320V AC for 48 hours and 440 V AC for 8 hours. WATT-110W. Make : Keselec /Rosa/Bega
89Supply of 8 Mtr height decorative having cast iron decorative base and pipe dia of 165 mm OD of1 mtr long , middle dia 101 mm with decorative cast iron decorative reducer jointing with 89 mm OD straight pipe with ornamental cast iron decorative ring. Pole shall be mounted on square base plate 300*300 *16 mm thickness suitable for mounting on 4 nos foundation bolts. The Pole Shaft should be fabricated out of Steel tube of grade YST 240.and batch test reports for chemical and mechanical properties of material should be submitted along with the bid. Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft.The welding shall be of high quality, carried out by qualified welders using approved welding procedures and tested for its quality through NDT method, such as DP Test. The pole shall be provided with an opening at the bottom with removable cover for providing connectors, MCB, etc. (to be supplied by others). Appropriate reinforcement shall be provided to compensate for the loss of section at this point to ensure overall structural stability of the pole under specified operating conditions. The pole shaft structure shall be hot dip galvanized through single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns. No mechanical operation, such as welding, drilling, etc. should be carried out on the pole structure post hot dip galvanizing. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. Complete pole shall be treated with high quality primer and thereafter coated with Polyurethane paint( Marine grade paint)to minimum average DFT of 70 microns. The painting shall be carried out by experienced and trained technicians using proven and established painting procedure. controlled’ paint drying process shall be used to ensure proper adhesion and finish of the paint. The streetlight pole shall be of ‘composite’ construction designed to withstand specified ‘dead load’ pertaining to the luminaire and its mounting accessories and ‘wind load’ corresponding to a basic wind speed of 169kmph without any deformation or damage to the structure. Make: Keselec /Bega/Rosa/Ligman/Simes as per drawing and matching specification.
90Decorative Single Arm Cascade bracket with 900 to 1000 mm height mounted on Pole. Decorative single arm bracket span of 500 to 1000 mm (as per lighting illumination design) single side (As per attached drawing), Hot dip galvanized as per ASTM A123, with minimum Average GI coating of 65 micron, PU painted with DFT of 70 micron using with high quality paint and prime. and bracket is painted with High quality Marine grade paint, painted in control environment. Make: Keselec /Bega/Rosa
91Decorative Double Arm Cascade bracket with 900 to 1000 mm height mounted on Pole. Decorative Double arm bracket span of 500 to 1000 mm(as per lighting illumination design) each side ( As per attached drawing), Hot dip galvanized as per ASTM A123,With minimum Average GI coating of 65 micron, PU painted with DFT of 70 micron using with high quality paint and prime. Bracket weight should be of 15 to 20 kg and bracket is painted with High quality Marine grade paint, painted in control environment Make : Keselec /Bega / Rosa
92Supply and Installation of BIS approvedalongwith BIS certification of model no with 15W, 50lm/W, 4000K/ 3000K Decorative bullet shaped Bollards height of 580 mm and width of 300mm. The Luminaire has a Cast Al base with a LDPE protector sealed on to the body, Optical and Control Gear tightness is IP66, IK10( Comply with Third party NABL approved IS10322/IEC60598 report ) CRI >70, PF > 0.90, THD <10% and Driver Efficiency >85%, Designed to withstand temp. range upto 50degree and Surge protection of 10kV, lumen mainetenance L70@ 50000Hrs.. /c connection wire and testing etc. to complete the job., Make Keselec /Neri/Bega
93Supply of street light pole 6 mt shall be of ‘composite’ construction designed to withstand specified ‘dead load’ pertaining to the luminaire and its mounting accessories and ‘wind load’ corresponding to a basic wind speed of 169kmph without any deformation or damage to the structure. The Pole Shaft should be fabricated out of Steel tube of grade YST 240 and batch test reports for chemical and mechanical properties of material should be submitted along with the bid. Structurally designed base plate of Steel A36/A572-50 or equivalent should be welded with the pole shaft.The welding shall be of high quality, carried out by qualified welders using approved welding procedures and tested for its quality through NDT method, such as DP Test. The pole shall be provided with an opening at the bottom with removable cover for providing connectors, MCB, etc. (to be supplied by others). Appropriate reinforcement shall be provided to compensate for the loss of section at this point to ensure overall structural stability of the pole under specified operating conditions. The pole shaft structure shall be hot dip galvanized through single dip process as per ASTM A123 and minimum average coating shall not be less than 65 microns. No mechanical operation, such as welding, drilling, etc. should be carried out on the pole structure post hot dip galvanizing. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. Complete pole shall be treated with high quality primer and thereafter coated with Polyurethane paint to minimum average DFT of 70 microns. The painting shall be carried out by experienced and trained technicians using proven and established painting procedure. controlled’ paint drying process shall be used to ensure proper adhesion and finish of the paint. 6 mtr pole with base diameter 140 mm up to 1 mtr height and rest 76 mm with base plate 250*250 *14 mm thickness, Height 6 meters. Make : Keselec /Bega/Rosa
94“B” class Galvanised iron pipe having smooth finished bore of the pipe on both ends erected nuts and bolts along the pole / wall shaping the pipe as per site requirement. Pipe dia as following. (b) 32 mm dia
95Providing & laying mains with 1-1 kV grade FR PVC insulated ISI Marked Stranded Copper cable having Conductor 3 wire 2.5 sq MM , 3 Core round PVC sheathed in exising pipe / in street light pole erected with 2.5 Sq. MM. copper conductor FR PVC insulated straned wire of green colour for earth continuity. - (11 Mtr per St. Light Fitting x 1 No. St. Light Fitting = 11 Mtr)
96Providing. Laying, testing & commissioning of1 x 4.0 Core x 10 Sq. MM. XLPE (IS: 7098 (i) - 88), ISI Mark, Armoured, Multistranded, Alluminium Conductor suitable for 1.1 kV grade to be laid on wall with necessary clamps or in exisiting cable trench/ pipe at road crossing or on floor and making the ground as per original. - For Streetlight between two poles & Service Connections.
97Providing. Laying, testing & commissioning of1 x 4.0 Core x 16 Sq. MM. XLPE (IS: 7098 (i) - 88), ISI Mark, Armoured, Multistranded, Alluminium Conductor suitable for 1.1 kV grade to be laid on wall with necessary clamps or in exisiting cable trench/ pipe at road crossing or on floor and making the ground as per original. - For Streetlight between two poles & Service Connections.
98Providing & laying of approved make 50 MM Nominal OD Double Walled Corrugated Pipes (DWC) of polyethylene (conforming to IS 14930 -ii) with necessary connecting accessories like coupler, Tee L- Bow, etc. of same material at required depth (90 cms) including excavation for laying of cable below ground/ road surface for enclosing cable and back filling the same to make ground as per original & as per instruction of EngineerIncharge - for Streetlight Cable of 1 x 4 core x 16 Sq. MM and Service cable of 1 x 4 core x 16 Sq. MM.
99PVC insulated flat submersible cable as per detailed technical specifications of R/C of GWSSB conforming to IS 694, IEC 60227 / 60228. e) 1 R x 3 C x 10.0 mm2
100Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat.III
101Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity, (b) 40 Amp, Cat.III
102Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (f) 2 to 4 core 10 Sq. mm
103Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 10 Sq.mm.
104Providing Approved make Triple Pole Metal Clad SwitchFuse Unit 415/500 V. with HRC fuse of suitable load and neutral link confirming to IS. (a) 32 A Cat.III
105Erection & connection charges for 32A/ 63 A / 100 AHRC TPN as following, (a)on existing wooden block /A.I.frame
106Providing & erecting 240 V MCB double pole switch for motor & inductive load(C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity , (A) 6 to 32 Amp. Cat.III
107Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp.
108Pipe type earthing having 150 cms. Long and 2.5 cms. dia. galvanised iron pipe with coupling and buch buried in specially prepared earth pit complete with necessary 8 SWG earth wire.
109For using salt and charcoal / coke as required for pipe type earthing.
110Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipeshaving Outer pipedia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (a) For Electrical Installation up to 440V in normal soil Length of pipe - 1 Mtr Back filling compound - 1 Nos Bag of 15 Kg.
111Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed.
112Providing and fixing Mounting Structure Grid Tie Mono Crystalline Solar Rooftop System, Grid type plant, Voltage 240/415 V, including Mounting structure, fixture, fastening, required cabeling, required Switches, connecting to main connection, etc complete as directed by engineer in-charge
113Providing, erecting, testing & commissioning approved make oil immersed naturally ONAN cooled, double wound, core type indoor / outdoor copper wound 11KV/ 433V step down transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil not exceeding 50 Deg.C.at maximum ambient temp. of 50 Deg. C. complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with I.S. 2026/1977& 1981 standards. Off load tap changing range steps 2.5% to 5% on H.V and L.V. for variation should be provided. The H.V. shall be connected Delta & Secondary with star connection. The transformer should have cable-end boxes on H.T. side suitable for up to 3 core 150 sq.mm. XLPE cable & on L.T. side suitable for busduct or cables as per requirement complete with test certificates from manufacturers 1. Oil conservator with filling Hole &Cap -One No. 2. Thermometer pocket with 6" dial typethermometer switch alarm & trip contacts-Two nos. 3. Silica-gel breather with charge- OneNo. 4. Plain oil level gauge -One No. 5. Drain / Sampling / Filter valve- One No. 6. Top Filter Valve -One No. 7. Explosion vent with Diaphragm -One No. 8. Rating & Diagram plate - One No. 9. Additional neutral bushing for earthing - One No. 10. Bi directional Roller - Four Nos. 11. Earthing terminals - Two Nos. 12. Lifting lugs - Two Nos.13. Air release plug. - One No. 14. Double float buchholz relay withAlarm and trip contacts. [As per ECBC code criteria] (d) 750 KVA Max. allowable loses at 50 % of ratedload is 2.3 KW and at full load is 6.6 KW Cat.III
114Supplying & erecting Galvanized iron pipe post “B” class 88.9 mm O.D 6 mtr. Long duly painted with two coats of aluminium paint complete with metallic base- plate of 300 mm x 300 mm x 4mm thick for usingas a compound light pole with approx. weight 47 Kg.
115Providing street light pole bracket comprising main Light Class MS tube of 4.2 cms. outside dia. complete with suitable M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5mm. /80 mm or require size pole top having sufficient fasteners for fixing the brackets and having suitable rise as per site condition as directed and spread of 2 mtr. With suitable welded stiffener reducer and with lock nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. Suitable for side entry fitting brackets of following nos of arms. [A] Double Arm Bracket 1.5 Mtr
116Providing street light pole bracket comprising main Light Class MS tube of 4.2 cms. outside dia. complete with suitable M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5mm. /80 mm or require size pole top having sufficient fasteners for fixing the brackets and having suitable rise as per site condition as directed and spread of 2 mtr. With suitable welded stiffener reducer and with lock nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. Suitable for side entry fitting brackets of following nos of arms. [A] Single Arm Bracket 1.5 Mtr
117“B” class Galvanised iron pipe having smooth finished bore of the pipe on both ends erected nuts and bolts along the pole / wall shaping the pipe as per site requirement. Pipe dia as following. (b) 32 mm dia
118Supplying & erecting approved make SMC press moulded composite FRP.loop-in, loop-out approx. 2mm thick box complete with Bakelite connector strip 4way & hinged doors having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box. (b) 250mm x 200mm x 100mm [deep]
119Supplying and erecting LED street light /Floor light fittings with High power White LEDs wattage of 1 Watt and above assembled on single MCPCB, efficiencymore than 130 lm/w and corrosion free High Pressure die cast aluminium housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and polycarbonate optics/ lenses with company mark/name engraved or embossed 120 to 300 V, Power Factor more than 0.95, THD < 10 %, CCT 5000 K to 5700K, Uniformity ratio > 0.45. Luminaire efficiency> 85 lumens/watt. LED driver efficiency > 85 % CREE OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridge Lux (U.S.A.) make LED used for luminaire. (Each fittings required LM-79 & LM-80 certificates) (A)Street Light (IP-65) surge- 4KV (g) 36 to 48 watts . Cat-III.
120Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables (d) 4 core 10 Sq. mm
121Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof following size of cable. (a) 3 core 2.5Sq. Mm
122Supply of flat P.V.C. cable for sub pump detailed technical specifications as per GWSSB rate contract. (5) 1 X 3 X 10 Sqmm
123Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
124Providing, supplying, Lowering, laying, fixing and jointing in standard length ISI mark rigid unplasticised PVC pipes and specials suitable for potable water with solvent cement joints incl.cost of couplers as per IS specification No.4985/1988 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, conveyance to the site and including cost of labour, material, cement solvent, giving satisfactory hydraulic testing as per ISI code. etc. complete (b) Test pressure 6 Kg/Sq.cm. 200mm diameter PVC slotted pipe.
125Providing and fixing of UPVC ball plug (bottom cap) suitable for 200 mm dia pipe
126Providing,supplying, lowering, laying, fixing and jointing in standard length ISI mark rigid unplasticised PVC pipes and specials suitable for potable water with ring fit joint including cost of rings, as per IS specification no. 4985/1988 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores and including cost of cost of labour, material, cement solvent, giving satisfactory hydraulic testing etc. complete.(PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge) PVC pipe 90 mm-10 kg/cm²
127Providing,supplying, lowering, laying, fixing and jointing in standard length ISI mark rigid unplasticised PVC pipes and specials suitable for potable water with ring fit joint including cost of rings, as per IS specification no. 4985/1988 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores and including cost of cost of labour, material, cement solvent, giving satisfactory hydraulic testing etc. complete. (PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge) PVC pipe 75 mm-10 kg/cm²
128Providing,supplying, lowering, laying, fixing and jointing in standard length ISI mark rigid unplasticised PVC pipes and specials suitable for potable water with ring fit joint including cost of rings, as per IS specification no. 4985/1988 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores and including cost of cost of labour, material, cement solvent, giving satisfactory hydraulic testing etc. complete. (PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge) PVC pipe 63 mm-10 kg/cm²
129Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(E) 50mm, (PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge)
130Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(D) 40mm, (PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge)
131Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(A) 20mm, (PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge)
132Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
133Providing, laying & jointing in position PVC/ HDPE pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers" instruction.PVC pipe 90mm-10 kg/cm2
134Providing, laying & jointing in position PVC/ HDPE pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers" instruction, PVC pipe 63mm-6 kg/cm2
135Providing, laying & jointing in position PVC/ HDPE pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers" instruction, PVC pipe 50mm-6 kg/cm2
136Providing, laying & jointing in position PVC/ HDPE pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers" instruction, PVC pipe 40mm-6 kg/cm2
137Providing, laying & jointing in position PVC/ HDPE pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers" instruction, Earthworkexcavationand refilling 300x450mm
138Providing & Fixing of3" 25-55 M3/HR HYDRAULIC AUTOBACKWASH SCREEN FILTER
139Providing & Fixing of(Monoblock/Openwell submersible) pumpset of having discharge 6.7 lps@52 mtrhead .suitable for pumpset having panel boxand fixed alongwith following accessories starter ,start / stop push buttons , Ammeter,Voltmeter , Indicating lamps, MCB ,with cable, etc.
140Providing and fixing ofcontrol panelsuitable for pumpset having panel boxand fixed alongwith following accessories starter ,start / stop push buttons , Ammeter,Voltmeter , Indicating lamps, MCB ,with cable, etc.
141Providing & fixing of controlValve /Butterfly Valvein mainlinefor bypass and flow diversion of approved quality 3"
142Providing & fixing of Non Return Valveto prevent back flow 3"
143Providing and fixing of Pressure Release Valve 2"
144Supply and fixing of Direct burial 14 AWG x 2C cablefor TWO way communication betweencontroller and DECODERS
145PVC conduit Pipe complete32 mm
146Providing & fixing of Rotatory Pop uphaving colour coded MP Rotator nozzle with multiplestream water spray capable of covering 2.5m- 10.7m with Matched Precipitation Rate .The Spray Head bodyshall be constructed of heavy-duty, ultraviolet resistant plasticand stainless steel spring with mutifunctional wiper seal withsmall exposed cover. (Hunter or equivalent as approved by Engineer In Charge)
147Providing & fixing of PS- Ultra, Pop up spray headbodies,having features an encased plastic "cage" to provide unmatched resistance to grit,with high efficiency ADJUSTABLE nozzle capable of covering 1.2M -5.2m at 1.0 - 2.1 Bars, pressur. Additionally Two-piece ratchet mechanism, Features is Precision controlled flush at pop-down clears debris from unit, Construction of time-proven UV_resitant plastic. (Hunter or equivalent as approved by Engineer In Charge)
148Providing & Fixing of SJ- 512, 1/2" Pop up Connecting Four Elbow Swing joint Assembly.The fittings shall be made of UV resistant thermo plastic.(HUNTER USA or equivalent as approved by Engineer In Charge)
149Providing and fixing ofPP service saddle ofvarying size.1/2" (Rainson / Accutech / equ or equivalent as approved by Engineer In Charge)
150Supplyand fixing of flexible Blank tubingand resistance to UV damage and algae growth black incolour 16 mm size. With all fittings and accessories.( Plain Dripline 16 mm plain lateral). (Jain / Netafim / Mais or equivalent as approved by Engineer In Charge)
151Supplyand fixing of PC dripers8lph(ain /Netafim or equivalent as approved by Engineer In Charge)
152Supply and FixingRod Comes Pre -Bent or plastic lateral stack to Staple DistributionTubing , DripLine to FinishedGrade.(Jain / Netafim / Polysil or equivalent as approved by Engineer In Charge)
153Supply, laying & commissioning of PVC Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve of size 63mm (JAIN / AUTOMAT or equivalent as approved by Engineer In Charge)
154Providing & fixing of IsolationValvein mainlinefor bypass and flow diversion of approved quality (LP / Kartar / zoloto or equivalent as approved by Engineer In Charge)
155Providing & fixing of a double acting 1"Air release valve,The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. Including service saddle and riser assembly.(Accutech / Harit or equivalent as approved by Engineer In Charge)
156Providing & fixing of 12" Rectangular Valve Box withgreenlid and corrugated structure with unique shovelaccess slot and bolt hole knockout (EcoRain or equivalent as approved by Engineer In Charge)
157Providing & fixing of 6"Roundbox withgreenlid and corrugated structure with unique shovelaccess slot and bolt hole knockout (EcoRain or equivalent as approved by Engineer In Charge)
158Providing & fixing of Brass Quickcoupling valve made up ofsolidbrass with locking covercorrosion resistant and stainless steel spring.Including service saddle and riser assembly.(Ecoaqua/accutech or equivalent as approved by Engineer In Charge)
159Providing & fixing of Brass Key threads into top of QCV to provide water access And Brass Swivel Elbow(Ecoaqua/accutech or equivalent as approved by Engineer In Charge)
160Providing & erecting open well horizontal mono block pump set with cast iron body, complete forthree phase submersible motor having, [D] For 5 HP 3 phase open well horizontal mono block pump set suitable for 1350 LPM to 310 LPM @ 10 to 42 Mtr head suitable for 50/65 mm dia delivery pipe
161Supplying & erecting approvedmake motor control cubical panel [Star delta] made from 16G CRCA sheet duly epoxy powder painted inside and outside with hinged doors and locking with suitable size of ON - OFF isolator (AC 3 / 23 duty) main fuses. Digital volt and current meter (in a single unit) with micro controller based control unit and current sensing single phasing preventer electronic overload protection, over voltage (Programmable) protection and under voltage (Programmable) protection, prod less dry run protection programming facility for setting of all parameter like overload current, high voltage limit, low voltage limit, dry run limit with digital indication on seven segment LED display for any fault like over load, high voltage, low voltage, dry running single crimped, electronic star delta timer, feather touch start / stop push buttons to be erected on angle iron frame. Grouted on wall the contactors will be of L& T, Siemens , BCH make only) (a)S/D up to 7.5 H.P.
162Providing & Fixing of,Suction ,Delivery & Header Pipe etc. complete as directed by engineer in-charge
163Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified, 100mm dia.
164Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications, NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified., 100mm dia.
165Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications,, Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified, 100 mm dia
166Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
167Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum, 50mm dia.
168Supply and fixing of Direct burial 14 AWG x 2C cablefor TWO way communication betweencontroller and DECODERS(Macrotherm or equivalent as approved by Engineer In Charge)
169PVC conduit Pipe complete32 mm (SUPREME/ASTRAL/RELAINCE or equivalent as approved by Engineer In Charge)
170Supply and fixing of ICC2 MEDIUM CONTROLLERS WITH EZ Decoder Output Moduleoutdoor mount with 230/240 VAC internal transformer control system , cycle +soak, Raindelay, SOLARSYNC Mini weather station,controlling upto 1 mastervalve with diagnostic feature in wire shorttest ,voltage test at stations, standard accessories complete.(Hunter or equivalent as approved by Engineer In Charge)
171Supply and fixing of EZ1 1 Station Decoder (Hunter or equivalent as approved by Engineer In Charge)
172Supply and fixing of 1"Solenoid globeValves with fabric reinforced diaphramand rugged PVC construction,compatible with and slow closing to prevent water hammer,pressure rating upto 10 bar with 24AC solenoid, withprovision to attachPressure Regulator (Hunter or equivalent as approved by Engineer In Charge)
173Supply and fixing of 1.5"Solenoid globeValves with fabric reinforced diaphramand rugged PVC construction,compatible with and slow closing to prevent water hammer,pressure rating upto 10 bar with 24AC solenoid, withprovision to attachPressure Regulator (Hunter or equivalent as approved by Engineer In Charge)
174Supplyand fixing ofdirect bury -on wireconnector withstrain relief , with waterproof silicon sealant. (Hunter or equivalent as approved by Engineer In Charge)
175Supply and fixingofACCU-SYNC-ADJ ACCU-SYNC PRESSURE REGULATOR, ADJUSTABLE PRESSURE MODEL 1.4–7 BAR (20–100PSI), WORKS WITH ANY HUNTER VALVE (Hunter or equivalent as approved by Engineer In Charge)
176Supply and fixingof copper grounding rod, clamps, charcoal and all requisite accessories complete ( or equivalent as approved by Engineer In Charge)
177Supplyand fixing of Pump relay24 ACPLA relay
178Supply, laying & commissioning ofHYDROPNEUMATIC PUMPING SYSTEMWITH VFD, 7.5 HP Motor of having discharge & headof design flow . No. of Pumps : 1 working + 1 Standybywith control panelsuitable for pumpset having panel boxmade of CRCA sheet of 2 mm thickness & fixed alongwith following accessories DOLstarter (L&T make),start / stop push buttons (L&T make), Voltmeter (AE make) , Indicating lamps (L & T make), MCB (L & T make), Dry level guard sensor (Minilec make) with Header Assemblyetc. with Pressure Tank and Pressure Switch.(LUBI / KIRLOSKAR or equivalent as approved by Engineer In Charge)
179Supply, laying & commissioning of Direct burial 14 AWG x 2C Decoder cablefor two way communication between controller and decoders.(MACROTHERM / PAIGE or equivalent as approved by Engineer In Charge)
180Supply, laying & commissioning ofDirect burial 14 AWG 1.2 Sq.mm. cablefor Sensor.(MACROTHERM / PAIGE or equivalent as approved by Engineer In Charge)
181Supply, laying & commissioning ofPVC conduit Pipe complete32 mm. (ISI MARK as approved by Engineer In Charge)
182Supply, laying & commissioning of ICC2 CONTROLLERS WITH DECODER SYSTEM. The controller shall be of a modular design with a standard 8 station model. There shall be 4 station and 8 station modules that enable the controller to be customized from 8 stations up to 32 stations in the plastic cabinet and up to 48 stations in the steel cabinets and plastic pedestal. Transformer input shall be 120/240 VAC, 50/60Hz.Transformer output shall be 24 VAC, 1.5A (40VA). Maximum output per station shall be 24 VAC, 0.56A.Program backup shall be provided by a non-volatile memory circuit that will hold the program information indefinitely.The controller shall have Metal Oxide Varistors (MOVs) on the AC power input portion and the secondary output portion to help protect the micro-circuitry from power surges.(HUNTER USA or equivalent as approved by Engineer In Charge)
183Supply, laying & commissioning of EZ1 DECODER FOR USE WITH CONTROLLER. (HUNTER USA or equivalent as approved by Engineer In Charge)
184Supply, laying & commissioning of 2"Solenoid globeValves PGV with fabric reinforced diaphramand rugged PVC construction,compatible with and slow closing to prevent water hammer,pressure rating upto 10 bar with 24AC solenoid, withprovision to attachPressure Regulator (HUNTER USA or equivalent as approved by Engineer In Charge)
185Supply, laying & commissioning of direct bury -on wireconnector withstrain relief , with waterproof silicon sealant. (HUNTER USA or equivalent as approved by Engineer In Charge)
186Supply, laying & commissioning of copper grounding rod, clamps, charcoal and all requisite accessories complete(HUNTER USA or equivalent as approved by Engineer In Charge)
187Supply, laying & commissioning of WEATHER STATION COMBINES MOISTURE AND RAIN SENSORS (HUNTER USA or equivalent as approved by Engineer In Charge)
188Supply, laying & commissioning of Pump relay24 ACPLA relay (ABB / L & T or equivalent as approved by Engineer In Charge)
189Supply, laying & commissioning of Sintex Weather proof box (SINTEX or equivalent as approved by Engineer In Charge)
190Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
191Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
192Grassing with selection No. 1/ Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). 2.10.1 In rows 5 cm apart in both directions
193Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
194Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
195Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
196Providing and stacking of Cassia javanica of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
197Providing and stacking of Dalbergia sissoo (Seasam) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge
198Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
199Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
200Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
201Providing and stacking of Ficus elastica Decora (Rubber ) of height 45-60 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.
202Providing and stacking of Pithecellobium dulce (Jungle Jalebi) of height 120-150 cm. in Big HDPE Bag as per direction of the officer-in-charge.
203Providing and stacking of Kigelia pinnata of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
204Providing and stacking of Lagerstroemia flosreginae of height 150-165 cm.in big poly bag of size 25 cm as per direction of the officer-in-charge.
205Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge.
206Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
207Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.
208Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
209Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
210Providing and stacking of Saraca indica (Sita Ashok) of height 105-120 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
211Providing and stacking of Spathodea campanulata of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
212Providing and stacking of Tecoma argentea of height 120-135 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
213Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-incharge.
214Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35-40 cm well developed in big size HDPE bags as per direction of the officer-in-charge.
215Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
216Providing and stacking of Washingtonia filifea palm stem ht. 120-135 cm with 8-10 healthy leaves lush green leaves well developed in big size HDPE Bags as per direction of the officerin- charge.
217Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.
218Providing and stacking of Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge.
219Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge.
220Providing and stacking of Ficus panda of height 60-90 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge.
221Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 75-90 cm. with 5-6 branches in bag of size 25 cm as per direction of the officer-in-charge.
222Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.
223Providing and stacking of Hibiscus rosasinensis of height 60-75 cm. with 5-6 branches in p.bag of size 25 cm as per direction of the officer-in-charge.
224Providing and stacking of Largerstroemia indica of height 45-60 cm. in polybag of size 20 cm as per direction of the officer-in-charge
225Providing and stacking of Nerium oleander (kaner) of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm as per direction of the officer-in-charge.
226Providing and stacking of Tecoma gaudichaudi of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
227Providing and stacking Allamanda cathartica of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
228Providing and stacking Allamanda violacea of height 30 cm to 45 cm. in poly bag of size 20 cm as per direction of the officer-in-charge.
229Providing and stacking Clerodendrum splendens of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
230Providing and stacking Petra volubilis of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
231Providing and stacking Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
232Providing and stacking Tecoma grandiflora of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
233Providing and stacking Vernonia elaegnifolia (curtain creeper) plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
234Providing and Displaying Cycus revoluta specimen plant, having 45 to 50 fresh and healthy, leaves having 30cm to 35cm circumfrance of base stem well developed in 40 cm challi, as per direction of the officer-in-charge.
235Providing and stacking of Nerium oleander (kaner) dwarf of height 30-40 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge. ICD No Description
236Providing and stacking of Nerium oleander variegated of height 60-75 cm., multibranched in earthen pots of size 25 cm as per direction of the officer-in-charge.
237Providing and stacking of Plumbego capensis well developed with fresh and healthy 30 to 45 cm ht., with bloom in 20 cm Earthen Pot/Plastic Pot as per direction of the officer-in-charge.
238Providing and stacking of Wedelia trilobata, full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge.
239Providing and Displaying Phoenix roebelenii palm well developed having 20 to 25 fresh & healthy leaves 90 to 105 cm ht. in 30 cm Cement Pot as per direction of the officer-in-charge.
240Providing and stacking of Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-incharge.
241Providing and stacking of Clerodendrum inerme of ht. 20 cm to 30 cm multi branched in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.
242Providing and Displaying Acalypha Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size of Earthen Pot/ Plastic Pot bushy plant as per direction of the officer-in-charge.
243Providing and stacking Canna dwarf of height 25 to 30 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
244Providing and stacking of Fountain Grass Red (Pennisetum setaceum) as per direction of the officer-in-charge.
245Providing and stacking of Fountain Grass Green (Pennisetum setaceum) as per direction of the officer-in-charge.
246Providing and displaying of Dracaena pendanus, well developed, having 6 to 8 suckers with healthy foliage in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge.
247Providing and stacking of Traveller Palm as per direction of the officer-in-charge.
248Providing and stacking of Bismarkia Palm as per direction of the officer-in-charge.
249Providing and stacking of Spider lily as per direction of the officer-in-charge.
250Providing and stacking of Alocasia borneo as per direction of the officer-in-charge.
251Providing and stacking of Uneven Rocks as per direction of the officer-in-charge.
252Providing and stacking of Cycas circinalis as per direction of the officer-in-charge.
253Providing and stacking of Terminalia metallica as per direction of the officer-in-charge.
254Providing and Displaying Bamboo Buddha valley with fresh & healthy 3 to 4 suckers having 75 to 90 cm ht. in 25 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.
255Providing and Displaying Bamboo Buddha vally variety with umbrella shape having 120 to 135 ht. with fresh & healthy foliage well developed in 40 cm Cement pot multy branch, bushy as per direction of the officer-in-charge.
256Providing and Displaying Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type well developed in 50 cm Cement Pot as per direction of the officer-in-charge.
257Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, edge, flower beds, foliages, creepers, plants etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers (whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide, Pesticide, lawn mover and brush cutter with fuel & other T & P material/ articles shall be provided by the department.) 2.39.5 Play grounds / Public parks Per Sqm/ (1Mali for 2.00Acre).
258Providing and supplying IP Night Vision wide angle Dome Camera - CP Plus (This camera is for Mandir area and multipurpose hall) 1/2.7” 2 Mega pixel HD camera 2.8 mm lens with viewing angle of 96 degrees High Performance Array LED for night vision upto 50 Ft (make as approved by engineer incharge)
259Providing and supplying IP Bullet Camera Weatherproof - CP Plus 1/3” 2 Mega pixel HD camera 3.6 mm IR board lens True Color at Day Light High Performance IR LED for Night- Vision (make as approved by engineer incharge)
260Providing and supplying IP Bullet Camera Weatherproof - CP Plus 1/3” 2 Mega pixel HD camera 2.8 to 12 mm varifocal lens Auto Iris auto focus High Performance IR LED for Night- Vision(make as approved by engineer incharge)
261Providing and supplying HD NETWORK VIDEO RECORDER 64 channel 4K - CP Plus 64 ch Motion Detection SATA-100 Dual Interface 2 USB2.0,TCP/IP(RJ45) supports DHCP, DDNS, RS-485 ports mobile view
262Providing and fixing HDD 6 TB SATA Hard Disk with 2 years warrantyas approved make and as directed by engineer in-charge etc. complete
263Installation Charges for Camera as directed by engineer in-charge including lens and necessary connections, fixture and fastening etc. complete
264Installation Charges for NETWORK VIDEO RECORDER 64 channels 4K as directed by engineer in-charge including necessary connections, fixture and fastening etc. complete
265Providing and fixing Cable CAT 6 D link Drum including necessary fixture and fastening as approved make and as directed by engineer in-charge etc. complete
266Providing and fixing 3 Pair Fiber optic cable Semi armouredas approved make and as directed by engineer in-charge etc. complete
267Providing and fixing 8 PORT POE Gigabit Switch with SFP port (This is for giving power to camera through Network switch)as approved make and as directed by engineer in-charge etc. complete
268Providing and fixing 24 PORT POE Gigabit Switch with SFP portas approved make and as directed by engineer in-charge etc. complete
269Providing and fixing RACK 2 U in Entry porch Near Toiletas approved make and as directed by engineer in-charge etc. complete
270Providing and fixing RACK 6 U in Multipurpose Hallas approved make and as directed by engineer in-charge etc. complete
271Providing and fixing Fiber optic cable Splicingas approved make and as directed by engineer in-charge etc. complete
272Providing and fixing Patch Cordas approved make and as directed by engineer in-charge etc. complete