Providing / Fitting, Installation , Testing And Commissioning Of Protection Panel Cum Fasd Starters For Pumping Unit No. 01 , 02 Along With Other Allied Works At Lis Nariana, Akhnoor-Jammu And Kashmir

Irrigation And Flood Control Department-IFCD has published Providing / Fitting, Installation , Testing And Commissioning Of Protection Panel Cum Fasd Starters For Pumping Unit No. 01 , 02 Along With Other Allied Works At Lis Nariana. Submission Date for this Tender is 23-09-2021. Starter Tenders in Akhnoor Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

29085892
Providing / Fitting, Installation , Testing And Commissioning Of Protection Panel Cum Fasd Starters For Pumping Unit No. 01 , 02 Along With Other Allied Works At Lis Nariana
Open Tender
Indian
Jammu And Kashmir
Akhnoor
23-09-2021

Tender Details

Providing / Fitting, Installation , Testing And Commissioning Of Protection Panel Cum Fasd Starters For Pumping Unit No. 01 , 02 Along With Other Allied Works At Lis Nariana

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
INR 7 Lakhs /-

BOQ Items

Name of Work: Providing/fitting, installation , testing and commissioning of protection panel cumFASD starters for pumping unit no. 01 & 02along with other allied works at LIS Nariana.
Sl. No. Item Description
1Providing/fitting, installation , testing and commissioning of protection panel cumFASD starters for pumping unit no. 01 & 02along with other allied works at LIS Nariana. Description of panel Designing, fabrication, installation, testing and commissioning of LT control panel415 volts, AC-3 Phase, 50 Hz. for pumpingunit no. 01 & 02at L.I.S Nariana. The panel shall be dust and vermin proof fabricated out of 16 SWG CR Sheet supported on M.S. angle of suitable size and having provision for fixing it on the ground with the help of foundation bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking /sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features: M.C.C.B.The panel should be fitted with an M.C.C.B. of400 Ampere capacity, 1 no. volt meter, 1 no ammeter along with a set of CTs, 1 No. V.S.S., 1 No. A.S. switch and a set of RYB indicators at incoming side including the bus bars . Outgoing no. 1 :The panel should be fitted with a 125HPfully automatic star delta starter comprises of 3 Nos. air break contactors compatible with 125HPinduction motor(2 nos. 185 A for main and delta supply, 1 No. air break contactor 140 A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of out going supply for pumping unit no. 1 Outgoing no. 2:The panel should be fitted with a 125HPfully automatic star delta starter comprises of 3 Nos. air break contactors compatible with 125HPinduction motor(2 nos. 185 A for main and delta supply, 1 No. air break contactor 140 A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of out going supply for pumping unit no.2. Protections device / fault analyzer : A protections devise / fault analyzer shall be fitted with the panel with capability to protect eachmotor by isolating the power supply of motor by de-energizing the starter/panel from followingelectro-mechanical faults which may otherwise damage the motor windings : A. Voltage related fault: Single phasing, under voltage, over voltage, unbalance voltage. B. Current related fault:Over current / load, dry running, unbalance current / load, earth leakage, short circuiting. C. Display line current of RYB Phase and also line voltage of RY ,YB and BR phase. Bimetal overload relay: Bimetal over load relay of suitable range should be fitted with in the eachstarter as an extra protection to protect the motorsin case of failure of fault analyzer . Providing/ fitting of suitable capacity single core copper cable (approx.40 mtrs.) from starter no. 01 &02 to motor no. 1 &2as per site conditions. Complete job includes cost of providing/ fitting ,transportationcharges ,hire charges of tool and tackles charges, hire charges of skilled and unskilled labour, and all kinds of taxes thereof.complete job Make ofMCCB – Any reputed make as per ISO standards.. Make of contactor – Any reputed make as per ISO standards... Make of cable – Any reputed make as per ISO standards..