Running Maintenance Of Different M.I. Schemes Under Salema Block And Kamalpur Nagar Panchayet During The Year 2021-22 / S.H- Minor Repairing And Maintenance Of Pump Motor, Suction Delivery, Electrical Equipment Etc. Running Maintenance Of Different, Kamalpur-Tripura

Public Works Department-PWD has published Running Maintenance Of Different M.I. Schemes Under Salema Block And Kamalpur Nagar Panchayet During The Year 2021-22 / S.H- Minor Repairing And Maintenance Of Pump Motor, Suction Delivery, Electrical Equipment Etc. Running Maintenance Of Different. Submission Date for this Tender is 27-09-2021. Screws Tenders in Kamalpur Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

29077374
Running Maintenance Of Different M.I. Schemes Under Salema Block And Kamalpur Nagar Panchayet During The Year 2021-22 / S.H- Minor Repairing And Maintenance Of Pump Motor, Suction Delivery, Electrical Equipment Etc. Running Maintenance Of Different
Indian
Tripura
Kamalpur
27-09-2021

Tender Details

Running Maintenance Of Different M.I. Schemes Under Salema Block And Kamalpur Nagar Panchayet During The Year 2021-22 / S.H- Minor Repairing And Maintenance Of Pump Motor, Suction Delivery, Electrical Equipment Etc. Running Maintenance Of Different M.I. Schemes Under Salema Block And Kamalpur Nagar Panchayet During The Year 2021-22 / S.H- Minor Repairing And Maintenance Of Pump Motor, Suction Delivery, Electrical Equipment Etc. - 1.00 Dismentaling Of Pump For Over Hauiling Including Greasing, Gland Packing, Necessary Repairs & Reinstallation Of The Same Including Trial Run For 10 Hrs. In Two Spell Complete As Per Direction Of The Engineerin- Charge. 2.00 Providing & Fitting Fixing C.I Coupling Complete With Nuts & Bolts Of Approved Quality. 2.01 150 Mmφ 2.02 190 Mmφ 3.00 Providing & Fitting Fixing Coupling Nuts & Bolts ( All Size ) Of Approved Quality. 4.00 Providing & Fitting Fixing Coupling Rubber Bush ( All Size ) Of Approved Quality. 5.00 Providing & Fitting Fixing Coupling Star Bush ( All Size ) Of Approved Quality. 6.00 Providing & Fitting Fixing Pump Shaft Of Approved Quality. 7.00 Providing & Fitting Fixing Shaft Sleeve Of Approved Quality. Cast Iron ( Ci ) 8.00 Providing & Fitting Fixing Shaft Sleeve Nut Of Approved Quality. Cast Iron ( Ci ) 9.00 Providing & Fitting Fixing C.I. Impeller Of Approved Quality For Horizontal Pump 10.00 Providing & Fitting Fixing Coupling / Impeller Key Of Approved Quality. 11.00 Providing & Fitting Fixing Casing Ring Of Approved Quality 12.00 Providing & Fitting Fixing C.I. Gland Of Approved Quality 13.00 Providing & Fitting Fixing Nuts & Bolts Full Threaded 10Mm Dia And 100 Mm Long ( Stag Nut ) For Gland Of Approved Quality 14.00 Providing & Fitting Fixing Lantern Ring For Pump Of Approved Quality 15.00 Supply & Fitting Fixing Ball Bearing Of Approved Quality For Pump Required During Overhauling. 15.01 6305 Ball Bearing ( Tata / Skf ) 15.02 6306 Ball Bearing ( Tata / Skf 16.00 Supplying & Fitting Fixing Of Gi . Bend Of Approved Quality 16.01 125 Mm Dia 16.02 150 Mm Dia 17.00 Hiring Charge Of Welding Set Of Single Phase With Operating Staff And Carrying Upto The Site Of Work Including Loading And Unloading ( Both Way ) Complete As Per Direction Of Engineer-Incharge. 18.00 Providing & Fitting Fixing M.S Flange ( 10Mm Thick ) At Site Of Work Of Approved Quality. 18.01 150 Mm Dia 18.02 125 Mm Dia 19.00 Providing & Fitting Fixing Rubber Flange Washer 6 Mm Thick At Site Of Work Of Approved Quality. 19.01 150 Mm Dia 19.02 125Mm Dia 20.00 Providing & Fitting Fixing Ms Hose Clamp With Nuts & Bolts Etc. Complete At Site Of Work Of Approved Quality. 150 Mm Dia 21.00 Providing & Fitting Fixing Pvc Suction Hose Pipe Overall Thickness 5Mm Of Best Quality At Site Of Work ( Pankaj Made ) Of Approved Quality : 150 Mm Dia 22.00 Providing & Fitting Fixing C.I Tail Piece Of Approved Quality At Site Of Work. - 150 Mm Dia 23.00 Providing & Fitting Fixing C.I Foot Valve Of Heavy Duty At Site Of Work Of Approved Quality. 150 Mm Dia 24.00 Providing & Fitting Fixing C.I Foot Valve Weight 150Mm Dia At Site Of Work Of Approved Quality. 25.00 Providing & Fitting Fixing C.I Foot Valve Ring 150Mm Dia At Site Of Work Of Approved Quality. 26.00 Providing & Fitting Fixing C.I Foot Valve Net 150Mm Dia At Site Of Work Of Approved Quality. 27.00 Dismentaling Of Old Pump / Motor From Base & Stacking Of Materials & Return The Same To Sub-Divisional Store As Per Direction Of The Engineer-In-Charge. 28.00 Dismental Of Horizontal Pump And Motor Of 20 / 25 Hp From The Base And Carrying The Pump Set To The Nearest Workshop For Repairing The Body Thread Of Stag Nut And Carrying The Same To The Scheme And Fitting Fixing The Pump Set As Before As Per Direction Of The Engineerin- Charge. 29.00 Dismentaling Of G.I Pipe Including Necessary Earth Cutting Etc. & Return The Same To Sub-Divisional Store As Per Direction Of The Engineer-In-Charge. 125 / 150 Mm ɸ 30.00 Dismentaling Of G.I Bend Including Necessary Earth Cutting Etc. & Return The Same To Sub-Divisional Store As Per Direction Of The Engineer-In-Charge. 125 / 150 Mm ɸ 31.00 Installation Of Pumpset Including Carriage Of Materials From M.I Store Of Resource Division To Site Of Work Including Trial Run For 10Hrs. In Two Spell. 32.00 Dismentalling Of Motor For Vernishing, Heating Etc. Complete In / C Reinstallation And Trial Run For 10 Hrs In Two Spell Complete As Per Direction Of Engineer-In-Charge 33.00 Supplying And Greasing / Applying Of Grease In Wheel Bearing Complete As Per Direction Of Engineer-In-Charge. 34.00 Supplying And Fitting Fixing Of Asbestos Rope Of Best Quality As Per Direciton Of Engineer-In-Charge. 35.00 Excavating Trenches Required Width For Pipes, Cables, Etc. Including Excavation For Sockets, Collars Etc And Dressing Of Sides Ramming Of Bottoms , Depth Minimum 0.90M Including Getting Out The Excavated Soil And Then Returning The Soil As Required In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layers By Ramming Watering Etc. And Disposal Of Surplus Excavated Soil Within A Lead Of 50M ( For G.I And C.I Pipes ) A ) All Kinds Of Soil. I ) Pipes, Cables Etc Exceeding 75 Mm Dia But Not Exceeding 150 Mm Dia 36.00 Labour Charge For Laying Of G.I Pipe Conforming Is 1161, 3589 & 1239 Including Fitting Fixing Complete As Per Direction Of Engineer-In- Charge. 36.01 150 Mm Dia Nominal Bore ( Medium ) 36.02 125 Mm Dia Nominal Bore ( Medium ) 37.00 Installation Of Pumpset Including Carriage Of Materials From M.I Store Of Resource Division To Site Of Work Including Trial Run For 10Hrs. In Two Spell. 38.00 Providing & Fitting Fixing Of Pannel Board Of Local Teak Wood For Fitting & Fixing Of Electrical Items Including 2 Nos. Ms Angle Post ( Size 50X50x6mm 2.80 Mtr. Long ) Nuts& Bolts Etc. For Errection Of The Same By 1 : 1.5 : 3 Cement Concreate Casting ( 1Feetx1feetx2feet ) Below The Ground Level And Painting Two Or More Coats Of Synthetic Enamel Paint On Primer As Per Direction Of Engineer-In-Charge. 38.01 A ) Size 1.80X1.20X0.025 Mtr. 39.00 Dismental Of Pannel Board As Per Direction Of The Engineer-In-Charge 40.00 Labour Charge For Reinstallation Of All Electrical Equipments ( Dismentalled Serviceable Materials, If Any Additional / Replacement Of Electrical Eqiupments Required Will Be Paid Separtely ) On The Pannel Board Including Trial Run For 10 Hrs In Two Spell Complete As Per Direction Of The Engineer-In Charge. 41.00 Providing & Fitting Fixing Of Fully Automatic Star Delta Type Motor Startar ( 3Ph, 50 Hz, 415V 25Hp / 18.7 Kw Relay Range Within 17-25 ) In Steel Sheet Enclosure With Conductor , Timer Etc. Complete Suitable For Motor Pump Havells / L&T / Bch Make As Per Direction Of Engineerin- Charge. 42.00 Supplying & Fitting Fixing Manually Operated Oil Immerged Starter Of Approved Quality. A ) 30 Hp Osco / Bch Make 43.00 Supplying And Fitting Fixing Ac Voltmeter ( Moving Iron ) On The Panel Board Of Approved Quality. 43.01 Smi-144, Range 0-400 To 0-500 44.00 Supplying And Fitting Fixing Ac Ammeter ( Moving Iron ) On The Panel Board Of Approved Quality. 44.01 Smi-144, Range 0-10A 45.00 Supplying & Fitting Fixing Power Capacitor ( Isi Marked ) Of Approved Quality. 45.01 12.5 Kvar 46.00 Providing & Fixing 200 Amps Busbar Of Size 600X 450X100 Mm With 4 Nos. Copper Strip Of Size 450X40x4 Mm Of Approved Quality. 47.00 Supplying & Fitting Fixing Of 7 / 16 Copper Wire With All Electrical Equipments Including Trial Run Etc. Complete ( Isi Marked ) On The Pannel Board Of Approved Quality. 48.00 Supplying And Fitting Fixing Of Selector Switch On The Panel Board Of Approved Quality. 49.00 Supplying And Fitting Fixing Of Indicator Bulb ( Flush Type Containig 3Nos Batton Holder With Bulb ) ) On The Panel Board Of Approved Quality. 50.00 Supplying & Fitting Fixing Of 63 Amps Kit Cut For Main & Sub-Main Swich ( Male & Female ) 51.00 Supplying & Fitting Fixing Of 200 Amps Kit Cut For Main & Sub-Main Swich ( Male & Female ) 52.00 Supplying And Fitting Fixing Of 3 Pole Power Conductors-Type Ml 1.5, Range From 25-300 Ac-3 Suitable For Fully Automatic Star Delta Type Motor Startar L&T , Bch, Havells Make As Per Direction Of Engineer-In- Charge. 53.00 Supplying And Fitting Fixing Of Spare Contact Kit , Type Ml 1.5 Suitable For Fully Automatic Star Delta Type Motor Startar L&T , Bch, Havells Make As Per Direction Of Engineer-In- Charge. 54.00 Supplying And Fitting Fixing Of Spare Coil, Type Ml 1.5 Range Suitable For Fully Automatic Star Delta Type Motor Startar L&T , Bch, Havells Make As Per Direction Of Engineer-In- Charge. 55.00 Supplying And Fitting Fixing Of Bimetal Overload Relay, Relay Range 20-32, & 28-42, Directly Operated Suitable For Fully Automatic Star Delta Type Motor Startar L&T , Bch, Havells Make As Per Direction Of Engineer-In-Charge. 56.00 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material With All Lifts And Upto 50 M Lead Etc. Complete As Per Direction Of The Engineer- In-Charge:- 56.01 A ) Nominal Concrete 1:3:6 Or Richer Mix ( I / C Equivalent Design Mix ) 57.00 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material With All Lifts And Upto 50 M Lead Etc. Complete As Per Direction Of The Engineer- In-Charge:- 57.01 A ) 1:2:4 ( 1 Cement: 2 Fine Sand : 4 Graded Well Burnt Brick Aggregate 20 Mm Nominal Size ) 58.00 Centering Shuttering Including Struttings, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns. 59.00 Providing And Fixing Ms Bolts Including Nuts And Washers Complete As Per Standard Design:- 59.01 Above 300Mm Length.- 60.00 Providing And Fixing G.I. Pipes Medium Class As Per Is : 1239 With Latest Amendment Complete With G.I. Fittings Including Trenching And Refilling, Cutting And Making Good The Walls Etc. Complete As Per Chapter 20 Of Cpwd Specification And Direction Of The Engineer- In - Charge. A. External Work I. 40 Mm Dia. Nominal Bore- For Priming Line 61.00 Labour Charge For Lifting Of Hose Pipe From River Bad By Dismantling Of G.I. Suction Line And Refitting The Same After Cleaning The Pipe With Necessary Filling Etc. Complete As Per Direction Of The Engineer In Charge. 62.00 Reparing Of 125Mm Dia Sluice Valve By Dismentling In / C Changing Of Sluice Valve Spindle, Key, Gasket, Nuts And Bolts Etc. And Refitting Fixing The Same After Making Good In The Exisitng Delivery Line As Per Direction Of The Engineer In Charge. 63.00 Labour Charge For Dismentling Of 125Mm Dia Non-Return Valve And Refitting Fixing The Same After Proper Washing And Ressemling The C.I Seperator Plate Etc As Per Direction Of The Engineer In Charge. 64.00 Providing And Fitting Fixing Of Brass Fullway Valve With Handle In The Gi Pipe Line Including Cutting, Threading Etc. Complete As Per Cpwd Specification And Direction Of The Engineer - In -Charge. 40 Mm Dia 65.00 Providing And Fixing G.I. Union As Per Cpwd Specification And Direction Of The Engineer - In - Charge. 40 Mm Dia 66.00 Providing And Fixing G.I. Bend / Elbow In The Pipe Line Including Testing Of Joints Complete As Per Cpwd Specification And Direction Of The Engineer - In - Charge. 40 Mm Dia 67.00 Providing And Fixing G.I. Equal Tee With The Pipe Line Including Testing Of Joints Complete As Per Cpwd Specification And Direction Of The Engineer - In - Charge. 40 X 40 X 40 Mm Dia 68.00 Labour Charge For Checking The Panal Board And Making Safe Including Dismantling And Refitting Fixing Of Wire And Electrical Equipments And Reconstruction Etc Complete As Per Direction Of The Engineer In Charge. 69.00 Repairing Of 15 / 20 / 25 Hp Starter By Dismantling In / C Changing Of Magnetic Coil, Connecting Finger, Oli Finger Rod Etc Complete And Refitting Fixing The Same As Per Direction Of The Engineer In Charge. 70.00 Repairing Charge Of Busber Including Changing Of Copper Strip With Neccesary Screws, Nuts, Washer Including Proper Reconnection And Wiring Etc. Complete As Per Direction Of The Engineer In Charge. 71.00 Repairing Of Pump Shaft By Welding, Polishing Etc Complete As Per Direction Of The Engg-In-Charge. 72.00 Labour Charge For Dismantling, Turning Making Alignment Of Pump Motor Shaft For Suitable Fitting Coupling, Bearing, Sleeve Bush Etc As Per Direction Of The Engg-In-Charge. 73.00 Providing And Fitting Fixing Of Foot Valve Washer Of Approved Quality. 74.00 Repairing Of Impeller By Welding, Polishing Etc Complete As Per Direction Of The Engg-In-Charge.

Key Value

Document Fees
INR 1000 /-
EMD
INR 2926.0 /-
Tender Value
INR 2.92 Lakhs /-

BOQ Items

Name of Work : Running maintenance of differentM.I. Schemes under Salema Block & Kamalpur Nagar Panchayet during the year 2021-22/S.H:- Minor repairing and maintenance of Pump motor, suction delivery, electrical equipment etc.
Sl. No. Item Description
1Dismentaling of pump for over hauiling including greasing, gland packing, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineerin- Charge.
2Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality.
3150 mmf
4190 mmf
5Providing & fitting fixing coupling nuts & bolts (all Size) of approved quality.
6Providing & fitting fixing coupling rubber bush (All Size) of approved quality.
7Providing & fitting fixing coupling star bush (All Size) of approved quality.
8Providing & fitting fixing Pump Shaft of approved quality.
9Providing & fitting fixing Shaft sleeve of approved quality. Cast iron (CI)
10Providing & fitting fixing Shaft sleeve nut of approved quality. Cast iron (CI)
11Providing & fitting fixing C.I. Impeller of approved quality for Horizontal pump
12Providing & fitting fixing coupling/ impeller Key of approved quality.
13Providing & fitting fixing Casing ring of approved quality
14Providing & fitting fixing C.I. gland of approved quality
15Providing & fitting fixing Nuts & bolts full threaded 10mm dia and 100 mm long (Stag nut) for gland of approved quality
16Providing & fitting fixing Lantern Ring for pump of approved quality
17Supply & fitting fixing ball bearing of approved quality for pump required during overhauling.
186305 Ball bearing (TATA /SKF)
196306 Ball bearing (TATA /SKF
20Supplying & fitting fixing of GI . bend of approved quality
21125 mm dia
22150 mm dia
23Hiring charge of welding set of single phase with operating staff and carrying upto the site of work including loading and unloading (both way) complete as per direction of Engineer-incharge.
24Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality.
25150 mm dia
26125 mm dia
27Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality.
28150 mm dia
29125mm dia
30Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality. 150 mm dia
31Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality : 150 mm dia
32Providing & fitting fixing C.I tail piece of approved quality at site of work. - 150 mm dia
33Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality. 150 mm dia
34Providing & fitting fixing C.I foot valve weight 150mm dia at site of work of approved quality.
35Providing & fitting fixing C.I foot valve ring 150mm dia at site of work of approved quality.
36Providing & fitting fixing C.I foot valve net 150mm dia at site of work of approved quality.
37Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.
38Dismental of horizontal pump and motor of 20/25 HP from the base and carrying the pump set to the nearest workshop for repairing the body thread of stag nut and carrying the same to the scheme and fitting fixing the pump set as before as per direction of the Engineerin- charge.
39Dismentaling of G.I pipe including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge. 125/150 mm ?
40Dismentaling of G.I bend including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge. 125/150 mm ?
41Installation of pumpset including carriage of materials from M.I store of Resource Division to site of work including trial run for 10hrs. in two spell.
42Dismentalling of motor for vernishing, heating etc. complete in/c reinstallation and trial run for 10 hrs in two spell complete as per direction of Engineer-in-charge
43Supplying and greasing/applying of grease in wheel bearing complete as per direction of Engineer-in-charge.
44Supplying and fitting fixing of asbestos rope of best quality as per direciton of Engineer-in-charge.
45Excavating trenches required width for pipes, cables, etc. including excavation for sockets, collars etc and dressing of sides ramming of bottoms , depth minimum 0.90m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavated soil within a lead of 50m (For G.I and C.I pipes) A) All kinds of soil. i) Pipes, cables etc exceeding 75 mm dia but not exceeding 150 mm dia
46Labour charge for laying of G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per direction of Engineer-in- Charge.
47150 mm dia nominal bore(medium)
48125 mm dia nominal bore(medium)
49Installation of pumpset including carriage of materials from M.I store of Resource Division to site of work including trial run for 10hrs. In two spell.
50Providing & fitting fixing of pannel board of local teak wood for fitting & fixing of electrical items including 2 nos. MS angle post ( Size 50X50X6mm 2.80 Mtr. long) nuts& bolts etc. for errection of the same by 1 : 1.5 : 3 cement concreate casting (1feetX1feetX2feet) below the ground level and painting two or more coats of synthetic enamel paint on primer as per direction of Engineer-in-Charge.
51a) Size 1.80X1.20X0.025 mtr.
52Dismental of pannel board as per direction of the Engineer-in-charge
53Labour charge for reinstallation of all electrical equipments (dismentalled serviceable materials, if any additional/ replacement of electrical eqiupments required will be paid separtely)on the pannel board including trial run for 10 hrs in two spell complete as per direction of the Engineer-in Charge.
54Providing & fitting fixing of Fully Automatic Star Delta type Motor startar ( 3ph, 50 Hz, 415V 25HP/18.7 kw Relay range within 17-25) in steel sheet enclosure with Conductor , Timer etc. complete suitable for motor pump Havells/L&T/BCH make as per direction of Engineerin- Charge.
55Supplying & fitting fixing manually operated oil immerged starter of approved quality. a) 30 Hp Osco/BCH Make
56Supplying and fitting fixing AC Voltmeter (Moving Iron) on the panel board of approved quality.
57SMI-144, Range 0-400 to 0-500
58Supplying and fitting fixing AC Ammeter (Moving Iron) on the panel board of approved quality.
59SMI-144, Range 0-10A
60Supplying & fitting fixing power capacitor (ISI Marked) of approved quality.
6112.5 KVAr
62Providing & fixing 200 Amps busbar of size 600X 450X100 mm with 4 nos. copper strip of size 450X40X4 mm of approved quality.
63Supplying & fitting fixing of 7/16 Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.
64Supplying and fitting fixing of selector switch on the panel board of approved quality.
65Supplying and fitting fixing of Indicator bulb (Flush type containig 3nos batton holder with bulb)) on the panel board of approved quality.
66Supplying & fitting fixing of 63 Amps kit cut for main & sub-main swich (Male & female)
67Supplying & fitting fixing of 200 Amps kit cut for main & sub-main swich (Male & female)
68Supplying and fitting fixing of 3 pole power conductors-type ML 1.5, range from 25-300 AC-3 suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge.
69Supplying and fitting fixing of spare contact kit ,type ML 1.5 suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge.
70Supplying and fitting fixing of spare coil, type ML 1.5 range suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge.
71Supplying and fitting fixing of bimetal overload relay, relay range 20-32, & 28-42, directly operated suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in-Charge.
72Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:-
73a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
74Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:-
75a) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size)
76Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns.
77Providing and fixing MS bolts including nuts and washers complete as per standard design:-
78Above 300mm length.-
79Providing and fixing G.I. pipes medium class as per IS : 1239with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per chapter 20 of CPWD specification and direction of the Engineer- in - charge. A. External work i. 40 mm dia. nominal bore- For Priming line
80Labour charge for lifting of hose pipe from river bad by dismantling of G.I. suction line and refitting the same after cleaning the pipe with necessary filling etc. complete as per direction of the Engineer in charge.
81Reparing of 125mm dia sluice valve by dismentling in/c changing of sluice valve spindle, key, gasket, nuts and bolts etc. and refitting fixing the same after making good in the exisitng delivery line as per direction of the Engineer in charge.
82Labour charge for dismentling of 125mm dia non-return valve and refitting fixing the same after proper washing and ressemling the C.I seperator plate etc as per direction of the engineer in charge.
83Providing and fitting fixing of brass fullway valve with handle in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in -charge. 40 mm dia
84Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. 40 mm dia
85Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. 40 mm dia
86Providing and fixing G.I. equal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. 40 x 40 x 40 mm dia
87Labour charge for checking the panal board and making safe including dismantling and refitting fixing of wire and electrical equipments and reconstruction etc complete as per direction of the engineer in charge.
88Repairing of 15/20/25 HP starter by dismantling in/c changing of magnetic coil, connecting finger, oli finger rod etc complete and refitting fixing the same as per direction of the Engineer in charge.
89Repairing charge of busber including changing of copper strip with neccesary screws,nuts, washer including proper reconnection and wiring etc. complete as per direction of the engineer in charge.
90Repairing of pump shaft by welding, polishing etc complete as per direction of the Engg-in-Charge.
91Labour charge for dismantling,turning making alignment of pump motor shaft for suitable fitting coupling,bearing,sleeve bush etc as per direction of the Engg-in-Charge.
92Providing and fitting fixing of foot valve washer of approved quality.
93Repairing of impeller by welding, polishing etc complete as per direction of the Engg-in-Charge.