Provision Of Medical Store At 5 Afh Jorhat Under Ge ( Af ) Jorhat - 1 Schedule A Partslump Sum Price Worked Out By The Contractor ForBuilding Works As Listed In Schedule A Part-I. 2 Lump Sum Price Worked Out By The Contractor ForSite Dev, GE (AF) Jorhat-Assam

Military Engineer Services-MES has published Provision Of Medical Store At 5 Afh Jorhat Under Ge ( Af ) Jorhat - 1 Schedule A Partslump Sum Price Worked Out By The Contractor ForBuilding Works As Listed In Schedule A Part-I. 2 Lump Sum Price Worked Out By The Contractor ForSite Dev. Submission Date for this Tender is 12-10-2021. Cushioning Supplies Tenders in GE (AF) Jorhat Assam. Bidders can get complete Tender details and download the document.




Tender Notice

29028609
Corrigendum : Provision Of Medical Store At 5 Afh Jorhat Under Ge ( Af ) Jorhat - 1 Schedule A Partslump Sum Price Worked Out By The Contractor ForBuilding Works As Listed In Schedule A Part-I. 2 Lump Sum Price Worked Out By The Contractor ForSite Dev
Open Tender
Indian
Assam
GE (AF) Jorhat
12-10-2021

Tender Details

Provision Of Medical Store At 5 Afh Jorhat Under Ge ( Af ) Jorhat - 1 Schedule A Partslump Sum Price Worked Out By The Contractor ForBuilding Works As Listed In Schedule A Part-I. 2 Lump Sum Price Worked Out By The Contractor ForSite Development And Earth Work As Listed In Schedule A Part-Ii. 3 Lump Sum Price Worked Out By The Contractor ForInternal Water Supply As Listed In Schedule A Part-Iii 4 Lump Sum Price Worked Out By The Contractor ForInternal Electrification As Listed In Schedule A Part-Iv 5 Lump Sum Price Worked Out By The Contractor ForRoad / Path As Listed In Schedule A Part-V 6 Lump Sum Price Worked Out By The Contractor ForSewage Disposal As Listed In Schedule A Part-Vi 7 Lump Sum Price Worked Out By The Contractor ForArea Drainage As Listed In Schedule A Part-Vii 8 Lump Sum Price Worked Out By The Contractor ForExternal Water Supply As Listed In Schedule A Part-Viii 9 Lump Sum Price Worked Out By The Contractor ForExternal Electrification As Listed In Schedule A Part-Ix 10 Lump Sum Price Worked Out By The Contractor ForAir Conditioning As Listed In Schedule A Part-X 11 Miscellaneous Items Schedule A Part Xiinternal Water Supplysupply And Fix For Brass Chromium Plated Health Faucet With 30 Long Cp Flexible Connection Pipe And Chromium Plated Brass Nuts At One End Complete All As Specified And As Directed. 12 Supply And Fix For 32Mm Bore Pvc Waste Pipe Suitable For Whb Complete All As Specified And As Directed. 13 Supply And Fix For Angle Cock Fancy Type Cp With Long Shank Cast Copper Alloy Screwed Downhigh Pressure With Crutch Or Butterfly Handlescrewed Both Ends Of Size 15Mm Bore Complete All As Specified And As Directed. 14 Internal Electric Supplysupply And Fix For Blanking Plate 1 Module Complete All As Specified And As Directed. 15 Supply And Fix For 20 Watts Integrated Led Tube Light Fitting 4 Ft Suitable For Single Phase 230 Volts, 50 Hz Ac Supply And Mounted On Wall Or Ceiling Complete With All Accessories Internally Prewired Including Electrically Connection With Copper Conductor Cable Of Size 0.5 Sqmm ( Nominal Area ) All As Per Cat No.Lctln-20-Cdl Of Make Crompton Or Equivalent Model In Philips / Wipro As Approved Complete All As Specified And As Directed. 16 Supply And Fix For Db Vtpn, 6 Way, 415 Volts, 50 Hz Ac Supply, 250 Amps Bus Bar With Double Metal Door Ip 43 Complete Prewired With And Including Incommer Mccb 160 Amps, 4 Pole, 16 Ka Breaking Capacity Complete All As Specified And As Directed . 17 Supply And Fix For Mcb Sp Rated Capacity 6 To 32 Amps, 240 Volts Breaking Capacity 10 Ka C Series Complete All As Specified And As Directed. 18 Supply And Fix For Mcb Spn Rated Capacity 6 To 32 Amps, 240 Volts Breaking Capacity 10 Ka C Series Complete All As Specified And As Directed. 19 Supply And Fix For Mcb Spn Rated Capacity 63 Amps, 240 Volts Breaking Capacity 10 Ka C Series Complete All As Specified And As Directed. 20 Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 Mm X 600 Mm X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Then 2.25 Meter Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Levelconnected To Galvanized Earth Wire 4.0 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel And Connected Tomain Control Board As Directed And Including Provision Ofconcrete Pit In Pcc ( 1:3:6 ) Type C1 ( Using 20Mm Graded Broken Stone Aggregate ) , Pre-Cast Rcc ( 1:2:4 ) Type B1 ( Using 20 Mm Graded Broken Stone Aggregate ) As Cover Slab 54 Cm X 54 Cm X 5 Cm Reinforced With And Including 8 Mm Dia Tmt Bars @ 100 Mm Centre To Centre Both Ways With One Handle For Lifting Made Out Of 10 Mm Dia Ms Bar, Funnel, Wire Mesh, 20 Mm Bore Galvanized Steel Tubing ( Medium Grade ) For Watering, Filling Charcoal Or Coke And Salt In Alternate Layers, 15 Mm Bore Galvanized Steel Tubing Light Grade For Protection Of Earth Lead Connection, Necessary Excavation And Earth Work In Any Type Of Soil And Including Necessary Testing Complete All As Shown Onelectrical Plate No.3 Of Ssr Part-I . ( Note: Gi Earth Strp And Protection Pipe Upto 7.5Metres Shall Be Deemed To Be Included In Unit Quoted Rate ) . 21 Supply And Fix For 30 Watts Led Light Fitting, New Generation Energy Saving And Environmental Friendly Long Life Versatile Pressure Die-Cast Aluminium Aesthetically Designed Road Way Luminaire With High Power Leds As Light Source And Electronic Driver Including Cable For Connection All As Per Cat No.Lsts-30-Cdl-M Of Make Crompton Or Equivalent Model In Philips / Wipro As Approved Complete All As Specified And As Directed. 22 Supply And Fix For Street Light Bracket On Pole Fabricated Out Of 40Mm Bore Gi Tube Light Grade Bed To Shapeas Directed And Of Length 1.0 Metre Complete With Mounting Ms Clamp Of Flat Iron Size 25 X 5Mm Of Suitable Length 2 Pairs Including Nut & Bolts Etc For Suitable Size And Painting Ms Clamp With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer Complete All As Specified And As Directed. 23 Sewagematerial And Labour For Construction Of 10 Users Hume Pipe Septic Tank Designed To Carry Sewage And Sullage Water, Excavation In Any Type Of Soil , Pcc ( 1:4:8 ) Type D2 ( Using 40Mm Graded Broken Stone Aggregate ) As In Foundation, Vent Shaft, Connection Etc Complete All As Specified And As Shown On Drawing. 24 Material And Labour For Soakage Wells Excavation In Any Type Of Soil, Pcc ( 1:3:6 ) Type C2 ( Using 40Mm Graded Broken Stone Aggregate ) As In Foundation, Wells Of Honey Combed And Solid Brick Work In Cm, Rcc Cover Slab, Filling With Bricks Bats Complete Of Size 1.2 Metres Dia And 1.50 Metres Depth Complete All As Specified And As Shown On Drawing. 25 External Water Supplymaterial And Labour For Horizontal Boring Below Pavement / Road In Soft / Loose Soilfor Crossing Up To 100 Mm Dia Gi Pipelines Complete All As Specified And As Directed. 26 Material And Labour For Construction Of Brick Masonry Valve Pit Chamber Of Inner Dimension 600Mm X 600Mm X 600 Mmsuitable For Sluice Valvesupto 100Mm Bore With Pcc ( 1:4:8 ) Type D2 ( Using 40Mm Graded Broken Stone Aggregate ) As In Foundation, Brick Workin Cm ( 1:6 ) , Rendering 15Mm Thick In Cm ( 1:4 ) , Coping In Pcc ( 1:2:4 ) Type B1 ( Using 20Mm Graded Broken Stone Aggregate ) Including Necessary Earth Work, Ms Sheet Cover Of Thickness 3.15Mmon 50Mm X 50Mm X 6Mm Angle Iron Frame Work Including Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer On Iron Or Steel Surfaces Complete All As Specified And As Directed. 27 Air Conditioning, External Electrification And Standby Power Supplysupply, Install, Testing And Commissioning Of Walk-In-Cold Room For Medical Storage Of Nominal Size 10 X 10 X 8 Feet Consisting Of Wall With Two Tire Shelves And Ceiling Panel Made Out Of Pgi Sheet Filled With 60Mm Puf Insulation, Anti Skid Aluminium Chequered Plate Flooring On 60Mm Puf, Door Of Suitable Dimension, Hydraulic Door Closer Digital Temperature Indicator With Auto Display Of Temp And Temp Logger Of 7 Days Alkaming System On Vertical And Electric Panel For Controlling With All Safety Features, Air Cooled Medium Temperature Split Unit 2 Hp Rating With Reciprocating / Scroll Compressors Working On R-410A Refrigerants To Maintain Temperature Of +2 To +8 Degree Centigrade At An Ambient Temperature Of 30 Degree Centigrade Complete All As Specified And As Directed. Make: Blue Star / Voltas / Carrier / Hitachi / Daikinn / Lg As Approved. 28 Supply, Fixing, Testing And Commissioning For Air Cooled Split Unit Indoor / Out Door Complete With Cordless Remote Control Unit And With In Built Air Ionizer And Plasma Filter For Better Indoor Air Quality Withwith 1, 5 Tr, Bee 3 Star Rated Complete All As Specified And As Directed. 29 Supply, Fixing, Testing And Commissioning For Voltage Stabilizer For Automatic Operation, Singlephase Naturally Air Cooled Indoor Type And Designed For Input Variation Between 170 Volt To 250 Volt With Out Put Voltage Stabilized At 230 Volt With Accuracy Of + 2.5% And Of Capacity 5 Kva Including Commissioning And Testing Complete All As Specified And As Directed. 30 Material And Labour For Interchanging Of Existing 100 Kva And 200 Kva Transformer From Existing Plinth Foundation To Proposed Site Complete All As Directed. 31 Supply, Install, Testing And Commissioning Of Automatic Power Factor Correction ( Apfc ) Panel Indoor Type Factory Made Of 80 Kvar Capacity Ready To Use And Ip 55 Design Confirming To Is 5039 / Is 8623 And Relevant Is / Iec Codes Rated For Short Circuit Rating Of 35 Ka, Front Openable And Lockable By Keys Having Louversand Air Vent Gasket And Totally Vermin Proof And Suitable For 415 / 440 Volts, 3 Phase, 50 Hz, Ac And Housed In Elegant Enclosure Fabricated From Minimum 2.00 Mm Thick Crca Sheet And Minimum 1.6 Mm Thick For Partitions Anticorrosive Coating To Improve Power Factor To 0.99 And Finally Powder Coated In Texture Siemens Grey Ral 7032 And Comprising Of And Including Following Suitable Size And Length Of Copper Conductor Cable Pvc Insulated, From Main Panel To Apfc Panel For Connection As Approved:- ( A ) 200 Amps Capacity For Phase And 100 Amps For Neutral, Copper Bus Duly Insulated Colour Coded Heat Shrinkable Sleeves And Mounted On Suitable Dmc / Epoxy Insulators. ( B ) A Set Of Heavy Duty, Capacitor, Type Mpp, 440 Volts, Box Typewith Out Put 80 Kvar Capacity, Capacitor Bank In Steps Of 5 / 10 / 12.5 / 25 / 50 Kvar In Any Configuration To Accommodate All Possible Set Ups. ( C ) Mccbs / Mcbs Tp C Series, 415 Volts Of Required Size With Required Numbers And Suitable Ratings As Per The Capacity Of Capacitors. ( D ) Microprocesser Based Control Suitable For Base Power Factor Correction With Its Unique Features Of Four Quadrant Operation Automatic C / K Ratio Selection. The Afc Controller Shouldon / Off The Capacitor Banks Of 80 Kvar Capacity Capacitor Bank In Steps 5 / 10 / 12.5 / 25 / 50 Kvar In Any Configuration To Accommodate All Possible Set Ups With Indication Whether It Is Lagging Or Reading. ( E ) Contactors 415 Volts, Air Break Type Shall Be Provided For Connecting / Disconnecting The Capacitor Banks To The Bus Bar. ( F ) The Apfc Panel Provided With Two Existing Terminal And It Is Connected Through Gi Strip 32X6 Mm Size To Existing Transformer Earthing / Panel Earthing Complete All As Specified And As Directed. ( G ) Digital Panel Meter For Current, Voltage / Frequency And Power Factor Having Suitable Ct Ratio And Built In Selector Switch Of Size 96Mm X 96 Mm, Accuracy Class-I Shall Be Provided. ( H ) All Control Wires Shall Not Be Less Than 2.5 Sqmm Multistranded Copper Conductor And Properly Bunched / Tied Ferruled For Proper Identification And Crimple With Adequate Size Of Lugs Etc Complete All As Directed. ( J ) Auto Manual Switch - 01 No. ( K ) Fuse For Line Protection As Per Requirement And As Approved. ( L ) Indicator Lamp Led Based With Lamp Holder As Per Requirement And As Approved. ( M ) Current Transformer ( Ct ) Of Ratio 200 / 5 Amps, Measuring Class Accuracy 0.5 To 1.0 For Capacitor Panel. ( N ) Incoming Mccb Capacity 125 Amps, 4 Pole, 415 Volts 50 Hz, 25 Ka Rupturing Capacity Fixed Manual Type -01 No.Note:- Anything Missed Out Above But Technically Required For Efficient Working Of Apfc Panel Is Deemed To Be Included In Unit Quoted Rate. 32 Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 Mm X 600 Mm X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Then 2.25 Meter Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Levelconnected To Galvanized Earth Strip 32 X 6 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel And Connected Tomain Control Board As Directed And Including Provision Ofconcrete Pit In Pcc ( 1:3:6 ) Type C1 ( Using 20Mm Graded Broken Stone Aggregate ) , Pre-Cast Rcc ( 1:2:4 ) Type B1 ( Using 20 Mm Graded Broken Stone Aggregate ) As Cover Slab 54 Cm X 54 Cm X 5 Cm Reinforced With And Including 8 Mm Dia Tmt Bars @ 100 Mm Centre To Centre Both Ways With One Handle For Lifting Made Out Of 10 Mm Dia Ms Bar, Funnel, Wire Mesh, 20 Mm Bore Galvanized Steel Tubing ( Medium Grade ) For Watering, Filling Charcoal Or Coke And Salt In Alternate Layers, 40 Mm Bore Galvanized Steel Tubing Light Grade For Protection Of Earth Lead Connection, Necessary Excavation And Earth Work In Any Type Of Soil And Including Necessary Testing Complete All As Shown Onelectrical Plate No.3 Of Ssr Part-I . ( Note: Gi Earth Strp And Protection Pipe Upto 7.5Metres Shall Be Deemed To Be Included In Unit Quoted Rate ) . 33 Material And Labour For Earthing Complete With Copper Earth Plate Electrode 300 Mm X 300 Mm X 3 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Then 2.25 Meter Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Levelconnected To Copper Earth Strip 20 X 3 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel And Connected Tomain Control Board As Directed And Including Provision Ofconcrete Pit In Pcc ( 1:3:6 ) Type C1 ( Using 20Mm Graded Broken Stone Aggregate ) , Pre-Cast Rcc ( 1:2:4 ) Type B1 ( Using 20 Mm Graded Broken Stone Aggregate ) As Cover Slab 54 Cm X 54 Cm X 5 Cm Reinforced With And Including 8 Mm Dia Tmt Bars @ 100 Mm Centre To Centre Both Ways With One Handle For Lifting Made Out Of 10 Mm Dia Ms Bar, Funnel, Wire Mesh, 20 Mm Bore Galvanized Steel Tubing ( Medium Grade ) For Watering, Filling Charcoal Or Coke And Salt In Alternate Layers, 40 Mm Bore Galvanized Steel Tubing Light Grade For Protection Of Earth Lead Connection, Necessary Excavation And Earth Work In Any Type Of Soil And Including Necessary Testing Complete All As Shown Onelectrical Plate No.3 Of Ssr Part-I . ( Note: Copper Earth Strip And Protection Pipe Upto 7.5Metres Shall Be Deemed To Be Included In Unit Quoted Rate ) . 34 Material And Labour For Earthing Complete With Copper Earth Plate Electrode 600 Mm X 600 Mm X 3 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Then 2.25 Meter Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Levelconnected To Copper Earth Strip 20 X 3 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel And Connected Tomain Control Board As Directed And Including Provision Ofconcrete Pit In Pcc ( 1:3:6 ) Type C1 ( Using 20Mm Graded Broken Stone Aggregate ) , Pre-Cast Rcc ( 1:2:4 ) Type B1 ( Using 20 Mm Graded Broken Stone Aggregate ) As Cover Slab 54 Cm X 54 Cm X 5 Cm Reinforced With And Including 8 Mm Dia Tmt Bars @ 100 Mm Centre To Centre Both Ways With One Handle For Lifting Made Out Of 10 Mm Dia Ms Bar, Funnel, Wire Mesh, 20 Mm Bore Galvanized Steel Tubing ( Medium Grade ) For Watering, Filling Charcoal Or Coke And Salt In Alternate Layers, 40 Mm Bore Galvanized Steel Tubing Light Grade For Protection Of Earth Lead Connection, Necessary Excavation And Earth Work In Any Type Of Soil And Including Necessary Testing Complete All As Shown Onelectrical Plate No.3 Of Ssr Part-I . ( Note: Copper Earth Strip And Protection Pipe Upto 7.5Metres Shall Be Deemed To Be Included In Unit Quoted Rate ) . 35 Material And Labour For Dry River Sand As In Sand Cushioning In Trenches / Ducts For Protection Of Underground Cable ( Below, Above And Around The Ug Cable Laid In Trenches ) Of 23 Cm Spread Thickness ( 8 Cm In Depth Before Laying The Cable And 15 Cm In Depth After Laying The Cable ) And Consolidated ( Punned ) Up To 18 Cm Thickness Complete All As Specified And As Directed. Note : - Thickness After Punning Shall Be Measured For Payment. 36 Material And Labour For Sub Class B, Old Size Bricks For Cable Protection Cover, Common Burnt Clay Building Bricks, Laid Dry And Flat Abutting Each Other With Width Equal To Length Of Brick And Gap Between Adjacent Bricks Not Exc.10Mm Complete All As Specified And As Directed. 37 Supply And Fix For Cable Junction Box 200X160x98 Mm In Size, Made Out Of Thermoplastic, Having Ip Protection For Outdoor Installation Fixed With 4 Way Bakelite Cable Terminals Including 03 Nos Polymide Gland With Check Nut ( M-32-02 No. & M-25-01 No. ) Fixed On Poles With Aluminium Clamps Of Size 25X3 Mm, Nuts, Bolts Washers Etc Including Taking Out Of Old Unserviceable Cable Junction Box As Per Cat No.K-9250 Of Make Hansel Or Equivalent Of Make Spelsberg / Rittal As Approved Complete All As Specified And As Directed. 38 Supply And Fix For Led Light Fitting 72 Watts, New Generation Energy Saving And Environmental Friendly Long Life Versatile Pressure Die-Cast Aluminium Aesthetically Designed Road Way Luminaire With High Power Leds As Light Source And Electronic Driver As Per Cat No.Lstp-72-Cdl-M Of Make Crompton Or Equivalent Of Make Philips / Ge As Approved Including Cable For Connection After Taking Down Old Unserviceable Light Fittings Complete All As Specified And As Directed. 39 Material And Labour For Pvc Insulated2.5 Sqmm 2 Core Multistranded Copper Conductor For Connection Of Security Light From Junction Box To Security Light Complete All As Specified And As Directed. 40 Supply, Installation, Testing And Commissioning Of Cubical Housing Cabinet Type Lt Feeder Pillar Box, Out Door Type, Platform Mounted , Factory Made, Cpri Approved, Totally Enclosed Dust And Vermin Proof Openable From Both From Front And Rear Side Made Out Of 3.15Mm Thick Crca Sheet Steel Of Overall Size 1200Mm ( Height ) X 1200Mm ( Width ) X 450Mm ( Depth ) And Built With Angle Iron Frame Work Of 50Mm X 50Mm X 5Mm, Having Front And Rear Hinged Doors Gi Earthing Strips At Rear Side, Bottom Detachablegland Plate Complete With Suitable Size Zinc Plated And Passivated Nuts, Bolts, Spring And Washers. The Cabinet All Members Should Be Chemically Treated With Msr Solution For Anticorrosive Treatment And Applying Powder Coated Paint ( Ral-7032 ) . The Peeder Pillar Box Should Be Suitable For 415 Volts, 50 Hz, 3 Phase, 4 Wire System And Internal Connection Should Be Provided With Aluminium Strips Suitable Size And Necessary Foundation Work And Comprising Of The Following:-Bus Bar: Sheet Steel Bus Bar Chamber Having Front Hinges Cover With A Set Of Electrolytic Grade High Conductivitytp&N Solid Aluminium Bus Bars Rated 400 Amps Supported At Required Interval Sleeved With Heat Shrinkable Pvc Sleevings. The Bars Shall Be Colour Coded At Required Intervals For Identification ( Set Of Four ) : 01 No.Incomer ( A ) Mccb 4 Pole, 320 Amps Capacity With Breaking Capacity Of 36 Ka - 01 No.Outgoing Feeders ( A ) Mccb 4 Pole, 160 Amps Capacity With Breaking Capacity Of 36 Ka - 01 No. ( For Medical Store Bldg Load - 01 ) ( B ) Mccb 4 Pole, 100 Amps Capacity With Breaking Capacity Of 36 Ka - 01 No. ( Apfc - 01 ) ( C ) Mccb 4 Pole, 63 Amps Capacity With Breaking Capacity Of 16 Ka - 02 No. ( For Medical Laundry Bldg And Spare - 01 ) ( D ) Mcb Spn 32 Amps C Curve With Breaking Capacity 10 Ka - 01 No. ( For Security Lights ) ( E ) Time Switch ( Astro Mini ) 110 - 240 Vac 1 Phase - 2W, 1 C / O, Base / Din With Accessories Of 10 Amps - 01 No. ( F ) Power Contactor 2 Pole 20 Amps - 01 No. ( G ) Bakelite Cable Connector 4 Way 40 Amps - 01 No.Indicator ( A ) Led Indicating Lamps For Main Supply Indicator R, Y, B - 01 Set Of 3 ( B ) Digital Voltmeter ( 96Mm X 96Mm ) 0-500 Volt With Selector Switchof 10 Amps - 01 No. ( C ) Current Transformer Having Ratio 300 / 5 - 01 Set Of 3. ( D ) Digital Ammeter 0-300 Amps With Selector Switch - 01 No. ( E ) Control Mcb Sp 2.0 Amps - 03 No. 41 Supply, Install, Testing And Commissioningsilent Type Diesel Engine Generating Set 415 Volts 100 Kva, 3 Phase 0.8 Power Factor, 50 Hz, 1500 Rpm Self Exited Self Regulated Brushless Ac Generator Installed Including Acoustic Enclosure Suitable For Ambient Condition At Jorhat And Confirming To Condition Under Iso 3046 With Capacity Of 10% Overloading For One Hour In Every 12 Hour Duration And Alternator With Following :-Alternator: Standard Design Alternator Rated At 100 Kvaat 0.8 ( Lag ) Power Factor Ac, 3 Phase, 4 Wire 415 Volts 50 Hz, 1500 Rpm, Self Excited Self Regulated With An Avr, Screen Protected Drip Proof Brushless Design With Winding In Pole Faces, Insulating Class H With Ip-23 Protections And Voltage Regulation Of +1% At Rated Voltage From No Load To Full Load. The Alternator Shall Be In Position To Generate Supply With Frequency Regulation Within +1% Tolerance. The Alternator Will Be Suitable For Tropical Climate And Shall Generally Confirm To Bs-2613 / 5000 / Is-4722.Control Panel: Control Panel Shall Be Fabricated From 16 / 14 Swg Sheeet And Powder Coated After 7 Tank Treatment Process: ( A ) Microprocessor Based Generator Set Monitoring And Control System Consist Of Lcd Display And To Monitor Operator Interface, Fault History, Alternator Data, Engine Data, Provision For Service Adjustment And Caliberation Of Dg Control Functions, Engine Controls, Engine Protective Function S Etc. ( B ) Instrument Fuses And Control Wiring. ( C ) Indication Lamps For Set Running And Load On. ( D ) Bus Bar Including Suitable Capacity Of Mccb / Mcb Including Cts, Cable Etc.Amf Panel: Automatic Mains Failure ( Amf ) Panel Made Crca Sheet 2 Mm Thick Including Necessary Arrangementto Install, Testing And Commissioning And Connecting Load Cable Up To Change Overswitch, Suitable Capacity Of 4 Pole Mccb Complete All As Per Oem Recommendation .Acoustic Enclosure: Manufactured By Oem Suitable For 100 Kva Dg Set.Civil Works: All Civil Works Including Pcc Platform And Related Foundation Including For Panel And Equipments Including Making Goodof Disturbed Area During Installation And Commissioning Of Generator Set. The Depth And Size Of The Foundationand Pcc As Recommended By The Manufacturer. 42 Material And Labour For Feather Kites Special Coated Wall Mounted Stand Suitable For 1.5 To 2.0 Tr Split Ac Out Door Unit Consisting Of Bracket 02 Nos, L- Angle - 02 Nos, 50 X 8Mm Anchor Fastener - 06 Nos Complete All As Specified And As Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Sep-2021 Corrigendumn 1 Date 27-09-2021
2 20-Sep-2021 Corrigendum 02 Date 28-09-2021
3 21-Sep-2021 Corrigendum 06 Technical Bid 28-09-2021
4 21-Sep-2021 Corrigendum 05 BOQ 28-09-2021
5 21-Sep-2021 Corrigendum 04 Technical Bid 28-09-2021
6 21-Sep-2021 Corrigendum 03 Technical Bid 28-09-2021
7 28-Sep-2021 Corrigendum 07 Date 05-10-2021
8 04-Oct-2021 Corrigendum 07 Technical Bid 05-10-2021
9 05-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-10-2021

Key Value

Document Fees
INR 1000 /-
EMD
INR 225000.0 /-
Tender Value
INR 1.50 Crore /-

BOQ Items

Name of Work: PROVISION OF MEDICAL STORE AT 5 AFH JORHAT UNDER GE (AF) JORHAT
Sl. No. Item Description
1SCHEDULE "A" PARTS Lump sum price worked out by the Contractor for"BUILDING WORKS" as listed in Schedule "A" Part-I.
2Lump sum price worked out by the Contractor for"SITE DEVELOPMENT AND EARTH WORK" as listed in Schedule "A" Part-II.
3Lump sum price worked out by the Contractor for"INTERNAL WATER SUPPLY" as listed in Schedule "A" Part-III
4Lump sum price worked out by the Contractor for"INTERNAL ELECTRIFICATION" as listed in Schedule "A" Part-IV
5Lump sum price worked out by the Contractor for"ROAD/PATH" as listed in Schedule "A" Part-V
6Lump sum price worked out by the Contractor for"SEWAGE DISPOSAL" as listed in Schedule "A" Part-VI
7Lump sum price worked out by the Contractor for"AREA DRAINAGE" as listed in Schedule "A" Part-VII
8Lump sum price worked out by the Contractor for"EXTERNAL WATER SUPPLY" as listed in Schedule "A" Part-VIII
9Lump sum price worked out by the Contractor for"EXTERNAL ELECTRIFICATION" as listed in Schedule "A" Part-IX
10Lump sum price worked out by the Contractor for"AIR CONDITIONING" as listed in Schedule "A" Part-X
11MISCELLANEOUS ITEMS SCHEDULE "A" PART XI INTERNAL WATER SUPPLY Supply and fix for brass chromium plated health faucet with 30" long CP flexible connection pipe and chromium plated brass nuts at one end complete all as specified and as directed.
12Supply and fix for 32mm bore PVC waste pipe suitable for WHB complete all as specified and as directed.
13Supply and fix for angle cock fancy type CP with long shank cast copper alloy screwed downhigh pressure with crutch or butterfly handlescrewed both ends of size 15mm bore complete all as specified and as directed.
14INTERNAL ELECTRIC SUPPLY Supply and fix for blanking plate 1 module complete all as specified and as directed.
15Supply and fix for 20 watts integrated LED tube light fitting 4 ft suitable for single phase 230 volts, 50 Hz AC supply and mounted on wall or ceiling complete with all accessories internally prewired including electrically connection with copper conductor cable of size 0.5 Sqmm (nominal area) all as per Cat No.LCTLN-20-CDL of make Crompton or equivalent model in Philips/ Wipro as approved complete all as specified and as directed.
16Supply and fix for DB VTPN, 6 way, 415 volts, 50 Hz AC supply, 250 Amps bus bar with double metal door IP 43 complete prewired with and including incommer MCCB 160 Amps, 4 pole, 16 KA breaking capacity complete all as specified and as directed .
17Supply and fix for MCB SP rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA "C" series complete all as specified and as directed.
18Supply and fix for MCB SPN rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA "C" series complete all as specified and as directed.
19Supply and fix for MCB SPN rated capacity 63 Amps, 240 Volts breaking capacity 10 KA "C" series complete all as specified and as directed.
20Material and labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less then 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 m below normal ground levelconnected to galvanized earth wire 4.0 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected tomain control board as directed and including provision ofconcrete pit in PCC (1:3:6) type C1 (using 20mm graded broken stone aggregate), pre-cast RCC (1:2:4) type B1 (using 20 mm graded broken stone aggregate) as cover slab 54 cm x 54 cm x 5 cm reinforced with and including 8 mm dia TMT bars @ 100 mm centre to centre both ways with one handle for lifting made out of 10 mm dia MS bar, funnel, wire mesh, 20 mm bore galvanized steel tubing (medium grade) for watering, filling charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown onelectrical plate No.3 of SSR Part-I . (Note: GI earth strp and protection pipe upto 7.5metres shall be deemed to be included in unit quoted rate).
21Supply and fix for 30 watts LED light fitting, new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium aesthetically designed road way luminaire with high power LEDs as light source and electronic driver including cable for connection all as per Cat No.LSTS-30-CDL-M of make Crompton or equivalent model in Philips/ Wipro as approved complete all as specified and as directed.
22Supply and fix for street light bracket on pole fabricated out of 40mm bore GI tube light grade bed to shapeas directed and of length 1.0 metre complete with mounting MS clamp of flat iron size 25 x 5mm of suitable length 2 pairs including nut & bolts etc for suitable size and painting MS clamp with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
23SEWAGE Material and labour for construction of 10 users hume pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil , PCC(1:4:8) type D2 (using 40mm graded broken stone aggregate) as in foundation, vent shaft, connection etc complete all as specified and as shown on drawing.
24Material and labour for soakage wells excavation in any type of soil,PCC (1:3:6) type C2 (using 40mm graded broken stone aggregate) as in foundation, wells of honey combed and solid brick work in CM, RCC cover slab, filling with bricks bats complete of size 1.2 metres dia and 1.50 metres depth complete all as specified and as shown on drawing.
25EXTERNAL WATER SUPPLY Material and labour for horizontal boring below pavement / road in soft/ loose soilfor crossing up to 100 mm dia GI pipelines complete all as specified and as directed.
26Material and labour for construction of brick masonry valve pit chamber of inner dimension 600mm x 600mm x 600 mmsuitable for sluice valvesupto 100mm bore with PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate ) as in foundation, brick workin CM (1:6), rendering 15mm thick in CM (1:4), coping in PCC (1:2:4) type B1 (using 20mm graded broken stone aggregate) including necessary earth work, MS sheet cover of thickness 3.15mmon 50mm x 50mm x 6mm angle iron frame work including two coats of synthetic enamel paint over a coat of red oxide primer on iron or steel surfaces complete all as specified and as directed.
27AIR CONDITIONING, EXTERNAL ELECTRIFICATION AND STANDBY POWER SUPPLY Supply, install, testing and commissioning of Walk-in-Cold room for Medical Storage of nominal size 10 x 10 x 8 feet consisting of wall with two tire shelves and ceiling panel made out of PGI sheet filled with 60mm PUF insulation, anti skid aluminium chequered plate flooring on 60mm PUF, door of suitable dimension, hydraulic door closer digital temperature indicator with auto display of temp and temp logger of 7 days alkaming system on vertical and electric panel for controlling with all safety features, air cooled medium temperature split unit 2 HP rating with reciprocating/ scroll compressors working on R-410A refrigerants to maintain temperature of +2 to +8 degree centigrade at an ambient temperature of 30 degree centigrade complete all as specified and as directed. Make: Blue star/ Voltas/ Carrier/ Hitachi/ Daikinn/ LG as approved.
28Supply, fixing, testing and commissioning for air cooled split unit indoor/ out door complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality withwith 1,5 TR, BEE 3 star rated complete all as specified and as directed.
29Supply, fixing, testing and commissioning for voltage stabilizer for automatic operation, singlephase naturally air cooled indoor type and designed for input variation between 170 Volt to 250 Volt with out put voltage stabilized at 230 volt with accuracy of + 2.5% and of capacity 5 KVA including commissioning and testing complete all as specified and as directed.
30Material and labour for interchanging of existing 100 KVA and 200 KVA transformer from existing plinth foundation to proposed site complete all as directed.
31Supply, install, testing and commissioning of automatic Power Factor Correction (APFC) panel indoor type factory made of 80 KVAR capacity ready to use and IP 55 design confirming to IS 5039/ IS 8623 and relevant IS/ IEC codes rated for short circuit rating of 35 KA, front openable and lockable by keys having louversand air vent gasket and totally vermin proof and suitable for 415/ 440 volts, 3 phase, 50 Hz, AC and housed in elegant enclosure fabricated from minimum 2.00 mm thick CRCA sheet and minimum 1.6 mm thick for partitions anticorrosive coating to improve power factor to 0.99 and finally powder coated in texture siemens grey RAL 7032 and comprising of and including following suitable size and length of copper conductor cable PVC insulated, from main panel to APFC panel for connection as approved:- (a) 200 Amps capacity for phase and 100 Amps for neutral, copper bus duly insulated colour coded heat shrinkable sleeves and mounted on suitable DMC/ epoxy insulators. (b) A set of heavy duty, capacitor,type MPP, 440 volts, box typewith out put 80 KVAR capacity, capacitor bank in steps of 5/10/12.5/25/50 KVAR in any configuration to accommodate all possible set ups. (c ) MCCBs/ MCBs TP "C" series, 415 volts of required size with required numbers and suitable ratings as per the capacity of capacitors. (d) Microprocesser based control suitable for base power factor correction with its unique features of four quadrant operation automatic C/K ratio selection. The AFC controller shouldON/ OFF the capacitor banks of 80 KVAR capacity capacitor bank in steps 5/10/12.5/25/50 KVAR in any configuration to accommodate all possible set ups with indication whether it is lagging or reading. (e) Contactors 415 volts, air break type shall be provided for connecting/ disconnecting the capacitor banks to the bus bar. (f) The APFC panel provided with two existing terminal and it is connected through GI strip 32x6 mm size to existing transformer earthing / panel earthing complete all as specified and as directed. (g) Digital panel meter for current, voltage/ frequency and power factor having suitable CT ratio and built in selector switch of size 96mm x 96 mm, accuracy class-I shall be provided. (h) All control wires shall not be less than 2.5 sqmm multistranded copper conductor and properly bunched/ tied ferruled for proper identification and crimple with adequate size of lugs etc complete all as directed. (j) Auto manual switch - 01 No. (k) Fuse for line protection as per requirement and as approved. (l) Indicator lamp LED based with lamp holder as per requirement and as approved. (m) Current transformer (CT) of ratio 200/ 5 Amps, measuring class accuracy 0.5 to 1.0 for capacitor panel. (n) Incoming MCCB capacity 125 Amps, 4 pole, 415 volts 50 Hz, 25 KA rupturing capacity fixed manual type -01 No. Note:- Anything missed out above but technically required for efficient working of APFC panel is deemed to be included in unit quoted rate.
32Material and labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less then 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 m below normal ground levelconnected to galvanized earth strip 32 X 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected tomain control board as directed and including provision ofconcrete pit in PCC (1:3:6) type C1 (using 20mm graded broken stone aggregate), pre-cast RCC (1:2:4) type B1 (using 20 mm graded broken stone aggregate) as cover slab 54 cm x 54 cm x 5 cm reinforced with and including 8 mm dia TMT bars @ 100 mm centre to centre both ways with one handle for lifting made out of 10 mm dia MS bar, funnel, wire mesh, 20 mm bore galvanized steel tubing (medium grade) for watering, filling charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown onelectrical plate No.3 of SSR Part-I . (Note: GI earth strp and protection pipe upto 7.5metres shall be deemed to be included in unit quoted rate).
33Material and labour for earthing complete with copper earth plate electrode 300 mm x 300 mm x 3 mm thick buried directly in ground (earth pit not less then 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 m below normal ground levelconnected to copper earth strip 20 X 3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected tomain control board as directed and including provision ofconcrete pit in PCC (1:3:6) type C1 (using 20mm graded broken stone aggregate), pre-cast RCC (1:2:4) type B1 (using 20 mm graded broken stone aggregate) as cover slab 54 cm x 54 cm x 5 cm reinforced with and including 8 mm dia TMT bars @ 100 mm centre to centre both ways with one handle for lifting made out of 10 mm dia MS bar, funnel, wire mesh, 20 mm bore galvanized steel tubing (medium grade) for watering, filling charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown onelectrical plate No.3 of SSR Part-I . (Note: Copper earth strip and protection pipe upto 7.5metres shall be deemed to be included in unit quoted rate).
34Material and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3 mm thick buried directly in ground (earth pit not less then 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 m below normal ground levelconnected to copper earth strip 20 X 3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected tomain control board as directed and including provision ofconcrete pit in PCC (1:3:6) type C1 (using 20mm graded broken stone aggregate), pre-cast RCC (1:2:4) type B1 (using 20 mm graded broken stone aggregate) as cover slab 54 cm x 54 cm x 5 cm reinforced with and including 8 mm dia TMT bars @ 100 mm centre to centre both ways with one handle for lifting made out of 10 mm dia MS bar, funnel, wire mesh, 20 mm bore galvanized steel tubing (medium grade) for watering, filling charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown onelectrical plate No.3 of SSR Part-I . (Note: Copper earth strip and protection pipe upto 7.5metres shall be deemed to be included in unit quoted rate).
35Material and labour for dry river sand as in sand cushioning in trenches/ ducts for protection of underground cable (below, above and around the UG cable laid in trenches)of 23 cm spread thickness ( 8 cm in depth before laying the cable and 15 cm in depth after laying the cable)and consolidated(punned) up to 18 cm thickness complete all as specified and as directed. Note : - Thickness after punning shall be measured for payment.
36Material and labour for sub class "B", old size bricks for cable protection cover, common burnt clay building bricks,laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exc.10mm complete all as specified and as directed.
37Supply and fix for cable junction box 200x160x98 mm in size, made out of thermoplastic, having IP protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-02 No. & M-25-01 No.) fixed on poles with aluminium clamps of size 25x3 mm, nuts, bolts washers etc including taking out of old unserviceable cable junction box as per Cat No.K-9250 of make HANSEL or equivalent of make SPELSBERG/ RITTAL as approved complete all as specified and as directed.
38Supply and fix for LED light fitting 72 watts, new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium aesthetically designed road way luminaire with high power LEDs as light source and electronic driver as per Cat No.LSTP-72-CDL-M of make CROMPTON or equivalent of make Philips/ GE as approved including cable for connection after taking down old unserviceable light fittings complete all as specified and as directed.
39Material and labour for PVC insulated2.5 sqmm 2 core multistranded copper conductor for connection of security light from junction box to security light complete all as specified and as directed.
40Supply, installation, testing and commissioning of cubical housing cabinet type LT feeder pillar box, out door type, platform mounted , factory made, CPRI approved, totally enclosed dust and vermin proof openable from both from front and rear side made out of 3.15mm thick CRCA sheet steel of overall size 1200mm (height) x 1200mm (width) x 450mm (depth) and built with angle iron frame work of 50mm x 50mm x 5mm, having front and rear hinged doors GI earthing strips at rear side, bottom detachablegland plate complete with suitable size zinc plated and passivated nuts, bolts, spring and washers. The cabinet all members should be chemically treated with MSR solution for anticorrosive treatment and applying powder coated paint (RAL-7032). The peeder pillar box should be suitable for 415 volts, 50 Hz, 3 phase, 4 wire system and internal connection should be provided with aluminium strips suitable size and necessary foundation work and comprising of the following:- BUS BAR: Sheet steel bus bar chamber having front hinges cover with a set of electrolytic grade high conductivityTP&N solid aluminium bus bars rated 400 Amps supported at required interval sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification (Set of four): 01 No. INCOMER (a) MCCB 4 pole, 320 Amps capacity with breaking capacity of 36 KA - 01 No. OUTGOING FEEDERS (a) MCCB 4 pole, 160 Amps capacity with breaking capacity of 36 KA - 01 No. (for Medical store Bldg load - 01) (b) MCCB 4 pole, 100 Amps capacity with breaking capacity of 36 KA - 01 No. (APFC - 01) (c) MCCB 4 pole, 63 Amps capacity with breaking capacity of 16 KA - 02 No. (for Medical laundry Bldg and spare - 01) (d) MCB SPN 32 Amps "C" curve with breaking capacity 10 KA - 01 No. (for security lights) (e) Time switch (Astro Mini) 110 - 240 VAC 1 phase - 2W, 1 C/O, base/ DIN with accessories of 10 Amps - 01 No. (f) Power contactor 2 pole 20 Amps - 01 No. (g) Bakelite cable connector 4 way 40 Amps - 01 No. INDICATOR (a) LED indicating lamps for main supply indicator R, Y, B - 01 Set of 3 (b) Digital Voltmeter (96mm x 96mm) 0-500 Volt with selector switchof 10 Amps - 01 No. (c) Current transformer having ratio 300/ 5 - 01 Set of 3. (d) Digital Ammeter 0-300 Amps with selector switch - 01 No. (e) Control MCB SP 2.0 Amps - 03 No.
41Supply, install, testing and commissioningsilent type Diesel Engine Generating set 415 volts 100 KVA, 3 phase 0.8 power factor, 50 Hz, 1500 RPM self exited self regulated brushless AC generator installed including acoustic enclosure suitable for ambient condition at JOrhat and confirming to condition under ISO 3046 with capacity of 10% overloading for one hour in every 12 hour duration and alternator with following :- Alternator: Standard design alternator rated at 100 KVAat 0.8 (lag) power factor AC, 3 phase, 4 wire 415 volts 50 Hz, 1500 RPM, self excited self regulated with an AVR, screen protected drip proof brushless design with winding in pole faces, insulating class "H" with IP-23 protections and voltage regulation of +1% at rated voltage from no load to full load. The alternator shall be in position to generate supply with frequency regulation within +1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS-2613/5000/IS-4722. Control Panel: Control panel shall be fabricated from 16/14 SWG sheeet and powder coated after 7 tank treatment process: (a) Microprocessor based generator set monitoring and control system consist of LCD display and to monitor operator interface, fault history, alternator data, Engine data, provision for service adjustment and caliberation of DG control functions, Engine controls, engine protective function s etc. (b) Instrument fuses and control wiring. (c) Indication lamps for set running and load on. (d) Bus bar including suitable capacity of MCCB/ MCB including CTs, cable etc. AMF Panel: Automatic Mains Failure (AMF)Panel made CRCA sheet 2 mm thick including necessary arrangementto install, testing and commissioning and connecting load cable up to change overswitch, suitable capacity of 4 pole MCCB complete all as per OEM recommendation . Acoustic Enclosure: Manufactured by OEM suitable for 100 KVA DG set. Civil Works: All civil works including PCC platform and related foundation including for panel and equipments including making goodof disturbed area during installation and commissioning of Generator set. The depth and size of the foundationand PCC as recommended by the manufacturer.
42Material and labour for feather kites special coated wall mounted stand suitable for 1.5 to 2.0 TR split AC out door unit consisting of bracket 02 Nos, L- angle - 02 Nos, 50 x 8mm anchor fastener - 06 Nos complete all as specified and as directed.