Up Gradation Of Chc Diglipur To Sub District Hospital, Diglipur , CHC, Diglipur-Andaman And Nicobar Islands

Andaman Public Works Dept-APWD has published Up Gradation Of Chc Diglipur To Sub District Hospital, Diglipur . Submission Date for this Tender is 06-09-2021. Civil Work Tenders in CHC, Diglipur Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

28827370
Corrigendum : Up Gradation Of Chc Diglipur To Sub District Hospital, Diglipur
Open Tender
Indian
Andaman And Nicobar Islands
CHC, Diglipur
06-09-2021

Tender Details

Up Gradation Of Chc Diglipur To Sub District Hospital, Diglipur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Aug-2021 Corrigendum No. 20 SE Dated 24-08-2021 Technical Bid 06-09-2021
2 25-Aug-2021 Corrigendum No. 3251 Dated 24-08-2021 Other 06-09-2021

Key Value

Document Fees
INR 1500 /-
EMD
Refer document
Tender Value
INR 4.14 Crore /-

BOQ Items

Name of Work: Up-gradation of CHC Diglipur to Sub District Hospital, Diglipur.
Sl. No. Item Description
1Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
2Beyond 120 cm girth upto and including 240 cm girth
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-Charge.
4All kinds of soil.
5Carriage and dumpingof earth within a lead of 1km
6Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
7All kinds of soil.
8Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
9Supplying and filling in plinth with Pulverisedsand under floors, including watering, ramming, consolidating and dressing complete.
10Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level :
111:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
121:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size).
131:4:8 (1 Cement : 4 coarse sand : 8 graded stoneaggregate 40 mm nominal size).
141:5:10 (1 cement : 5 coarse sand(zone-III) : 10 graded stone aggregate 40 mm nominal size)
15Centirng and shuttering including strutting, propping etc. andremoval of form for:
16Foundations, footings, bases of columns:
17Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc..
18Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
19Extra for providing and mixing water proofing material in cementconcrete work in the proportion recommended by the manufacturers
20Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
21Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of stone aggregate 40 mm nominal size, well rammed and consolidated and grouted with pulverised sand, including necessary excavation, levelling & dressing & finishing the top smooth.
22Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level :
231:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
24Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement :
251:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
26Reinforced cement concrete work inbeams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
27Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size).
28Centring and shuttering including strutting, propping etc. and removal of form for :
29Foundations, footings, bases of columns, etc. for mass concrete.
30Walls (any thickness)
31Suspended floors, roofs, landings, balconies and access platform.
32Lintels, beams, plinth beams, girders, bressumers and cantilevers.
33Columns, Pillars, Piers, Abutments, Posts and Struts.
34Stairs, (excluding landings) except spiral-staircases.
35Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
36Weather shade, Chajjas, corbels etc., including edges
37Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
38Thermo-Mechanically Treated bars of grade Fe-500D or more
39Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Above plinth level.
40Thermo-Mechanically Treated bars of grade Fe-500D or more
41Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
42Granite work
43Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
44Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
45Granite Stone of approved shade
46Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets :
4720 mm dia (heavy type)
48Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
49Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
50Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
51Twin rubber stopper
52Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticals sides of the frame reinforced with PVCprofile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer"s specification and direction of engineer-in- charge.
53Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer"s specification and direction of engineer-in-charge.
54Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.
55With 12 mm mild steel U beading.
56Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
57Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
58200x10 mm
59Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately)
60Providing and fixing panelling or paneling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587
61Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
62Electric resistance or induction butt welded tubes.
63Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
64Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
65Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
66Providing and fixing bolts including nuts and washers complete.
67Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
68Providing and fixing circular/ Hexagonal cast iron orM.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.
69Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
70In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
71Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
72Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.
7340 mm thick with 20 mm nominal size stone aggregate
74Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
7540 mm wide 4 mm thick
76Cement plaster skirting (upto 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement.
7718 mm thick.
78Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
79Size of Tile 600x600 mm
80Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
81Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqmincluding pointing the joints with white cement and matching pigments etc., complete.
82Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
83Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
84Providing and fixing plain Multipurpose Cement board ( High Pressure steam cured ) as per IS : 14862, with suitable screws for fibre cement board in ceiling etc. complete (frame work to be paid separately) :
856 mm thick Cement fiber board as per IS: 14862
86Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming toIS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes
87(i)Single socketed pipes. 110 mm diameter
88Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
89Coupler 110 mm
90Single push fit Coupler : 110 mm
91Single tee with door 110x110x110 mm
92Single tee without door 110x110x110 mm
93Bend87.5° 110 mm bend
94Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
95110 mm
96Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.
97Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
98Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
99Ridges plain (500 - 600mm).
10012 mm cement plaster of mix :
1011:4 (1 cement: 4 fine sand)
10215 mm cement plaster on rough side of single or half brick wall of mix :
1031:4 (1 cement : 4 coarse sand)
1046 mm cement plaster of mix :
1051:3 (1 cement : 3 fine sand)
106White washing with lime to give an even shade:
107New work (three or more coats)
108Finishing walls with water proofing cement pain of required shade :
109New work (Two or more coats applied @ 3.84kg/10 sqm
110Finishing walls with Acrylic Smooth exterior paint of required shade:
111New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
112Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
113Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm
114Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
115Two or more coats on new work over an under coat of suitableshadewithordinarypaint of approved brand and manufacture.
116Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
117Two or more coats on new work
118Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
119Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the subgrade and disposal of surplus earth with lead upto 50 metres.
120Providing ,Laying , spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of"screening / binding material to fill up interstices of coarse aggregate,watering and compacting to the required density .
121Sub-base with stone aggregate 90mm to 45mm including stone screening 13.20mm
122Base-Course with stone aggregate 63mm to 45mm including stone screening 13.20 mm (Type - A)
123Base-Course with stone aggregate 63mm to 45mm including stone screening 13.20 mm (Type - A)
124Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications :
125On bituminous surface @ 0.50 Kg / sqm
1262 cm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm. and 52 kg. and 56 kg. of hot bitumen per cum and 4.16 kg & 4.48 kg of shredded plastic per cum of stone chippings of 13.2 mm and 11.2 mm size respectively including a tack coat with hot straight run bitumen including consolidation with road roller of 6 to 9 tonne capacity etc. complete: (tack coat to be paid for separately).
127With paving Asphalt grade VG - 30 heated and then mixed with no solvent.
128Providing and laying Bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen of suitable penetration grade, including required key aggregate as specified, spreading coarse aggregate with the help of self propelled/ tipper tail mounted aggregate spreader and applying bitumen by a pressure distributor and then spreading key aggregate with the help of aggregate spreader complete, including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specified values of compaction and surface accuracy :
129For 50mm compacted thickness using coarse aggregate of size 50-20 mm graded @ 0.60 cum per 10 sqm key aggregate of size 12.5 mm graded @ 0.15 cum per 10 sqm. With paving asphalt grade VG - 10 @ 50 kg/ 10 sqm.
130Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete
131Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
132Made of G.I. wire of dia 4mm.
133Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
134White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
135Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
136W.C. pan with ISI marked black solid plastic seat and lid
137Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
138Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
139Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
140Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
141Rectangular shape 1500x450 mm
142Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
143White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
144Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
145Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms.
146Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
147Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
148450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
149Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.,
15020 mm nominal outer dia .Pipes.
151Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
15225 mm nominal outer dia .Pipes.
15340 mm nominal outer dia .Pipes.
154100 mm nominal inner dia pipes
15580 mm nominal outer dia Pipes
156Providing and fixing uplasticised PVC connection pipe with brass unions :
15730 cm length 15 mm nominal bore
158Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
159100 mm diameter
160Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes butwithout fittings and the base support for tank
161Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
16215 mm nominal bore.
163Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
16415 mm nominal bore.
165Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
16615 mm nominal bore.
167Providing and fixing ball valve CPVC of approved quality , High or low pressure, with plastic floats complete.
16825 mm nominal bore
169Providing and fixing PTMT grating of approved make.
170Rectangular type with openable circular lid (a) 150 mm nominal size square 100 mm diameter of the inner hinged round grating
171Supplying and fixing C.I. cover without frame for manholes
172500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
173Providing and laying properly as filter media in the filteration chamber which are tofree from all impurities etc
174Stone aggregate of size 40mm nominal size
175Stone aggregatel of size 20mm nominal size
176Charcoal Layer
177Coarse sand
178Providing and wrapping/laying / fixing of double fold long fibre Geo Textile membrane of weight 400gms/sqm
179Providing cement concrete surface drain with 1:3:6 ( 1 cement : 3 Coarse sand: 6 graded stone aggregate of 40 mm nominal size) cement concrete finished with 1:4 (1 cement : 4 sand) a floating coat of neat cement inside the drain and its top and exposed surface including earthwork in excavation and disposed of surplus earth etc.
18015x15mm surface drain
18123cm x 23cm surface drain
182Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
183Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
184For fixed portion (a) Powder coated aluminium (minimum thickness of powder coating 50 micron)
185For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). (a) Powder coated aluminium (minimum thickness of powder coating 50 micron)
186Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
187Upto 5 mm depth and 5 mm width.
188Providingandfixingglazinginaluminiumdoor,window,ventilatorshuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as perthe architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
189With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
190Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
191With stainless steel cover plate minimum 1.25 mm thickness.
192Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
193Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge
194Powder coated minimum thickness 50 micron aluminium
195Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
196Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
197Providing and laying flamed finish Granite stone in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in jointed with grey cement slurry mixed with pigment to match the shade of the slabs, matching shade complete.
198Providing and laying interlocking floor tiles 10 to 15 mm thick injointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
199Providing and fixing 6mm thick PVC moulded corner beading of required shape and colour to the junction of tile work includingfixing in the bed of cement mortar while fixing wall tiles etc. complete as per direction of Engineer-in-charge.
200Providing and fixing White Vitreous China Wash basin counter top Oval type (self rimming) of size 560x410 mm
201Providing and fixingstainless steel 304 grade Health Faucet, Wall Hook, including Flexible Hose pipe 1.25 Meter of approved quality
202Providing and fixing stainless steel swan neck pillar cock of approved quality and colour .
20315mm nominal bore,
204Providing and fixing Silver Chrome Finish Shower Arm 300mm long of approved quality
20515 mm nominal bore.
206Providing and laying hollow cement concrete block walling 200mm thick consisting hollow block of size 400 x 200x200mm of mix 1:3:6(1cement :3 coarse sand:6 graded stone agg. 10mm nominal down size) laid in cement mortar 1:6(1cement : 6 coarse sand)
207Providing and laying hollow cement concrete block walling 100mm thick consisting hollow block of size 400 x 100 x 200mm of mix 1:3:6(1cement :3 coarse sand:6 graded stone agg. 10mm nominal down size) laid in cement mortar 1:6(1cement : 6 coarse sand)
208Providing and fixing louvers in ventilators with frosted glass 5mm thick including cutting into shape and placing with frames of Anodized Colour Aluminium Louver Glass Holder for 5mm as per direction of Engineer-in-charge
209Constructingmasonry manhole with CC block laid in cement mortar 1:4 ( 1 cement : 4 Pulverised sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 Pulverised sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 Pulverised sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 Pulverised sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 Pulverised sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :
210Inside size 65x45 cm and 50 cm deep including C.I. cover with frame (light duty) 500 mm diameter C.I. coverand frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
211Providing and fixing 4 mm dia. G.I. wire for hangers (upto 3000mm length) fixed to roof truss frames by tieing at both ends complete as per direction of Engineer -in-charge.
212Extra for providing and fixing wind ties of 40x 6 mm flat Aluminium section.
213Providing and fixing soil, waste and vent pipes : with UPVC pipe coforming to IS:13592 type B including jointing of pipes and fittings with solvent cement etc complete as per direction of Engineer-in-charge
214110 mm dia.
21575mm dia
216Providing and fixing uPVC plain bend of required degree conforming to IS: 13592 : 2000
217110 mm dia.
21875mm dia
219Providing and fixing uPVC collar conforming to IS: 13592 : 2000
220110 mm dia.
22175mm dia
222Providing and fixing UPVC moulded door bend of required degree for UPVC soil pipes conforming to IS:13592 type "B" including jointing with seal ring conforming to IS:5382 living 10mm gap for thermal expansion 75 mm dia
223110 mm dia.
22475mm dia
225Providing and fixing uPVC double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :conforming to IS: 13592 : 2000
226110x110x110x110 mm
22775x75x75x75 mm
228Providing and fixing uPVC terminal guard
229110 mm dia.
23075mm dia
231Providing and fixing CPVC Union in CPVC pipe including cutting and joining the pipeetc. complete
23225 mm nominal bore
233Providing and fixing uPVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
234110 mm inlet and75 mm outlet
235Construction of septic tank with C.C wall suitable section with cement concrete 1:3:6 (1 cement : 3 coarse sand (Pulverised Sand) : 6 graded stone aggregate ) complete 20 cm thick including precast RCC top 10cm thick slab with 1:2:4 concrete 20 cm thick foundation concrete 1:4:8 inside plastering 12mm thick water proofing cement 1:4 finished with a floating coat of neat cement 50mm thick CC flooring with floating coat of neat cementincluding RCCbaffle wall 10cm thick 1:2:4 mix including 100mm dia C.I tees for inlet with terminals. Two CI manhole covers 80x610mm size total with not less then 38kg with framed fixed in RCC slab and M.S foot rest for manhole at 30cm center to center complete as per design drawing and direction of Engineer - in - charge.
23650 users having inside dimension 5.70 x 2.10 x 2.20 including 30 cm free board.
237Supply and installation of L shaped reception desk of size 2150mm Wide x 1675mm Deep x 1070mm Highwith drawers and reception counter features a fully reversible return and locking pedestal with box file and two drawers. Boasting plenty of secure storage space and ample surface area with a full height modesty panel made of rubber wood, polishing with melamine polish as per drawing and direction of Engineer-in-charge.
238Supply and installation ofreception desk of size Width of 1500mm x A height of 1200mm x a Depth of 600mm with drawers and reception counter features a fully reversible return and locking pedestal with box file and two drawers. Boasting plenty of secure storage space with a full height modesty panel made of rubber wood, polishing with melamine polish as per drawing and direction of Engineer-in-charge.
239Supply and installation of wall cabinet made of 18mm thick rubber wood planks of size 1500mm X 600mm X 2100mm with 4 nos of wooden racks and with glazed panneled door shutters sliding typeincluding polishing with melamine polish as per drawing and direction of Engineer-in-charge.
240Providing PVC pipe 50 mm dia in weep holes
241Stone boulder fillingfor filteration at back side of wall
242ABSTRACT- B
243Name of Work: Up-gradation of CHC Building to Sub-District Hospital, Diglipur
244Sub Work: Providing IEI, Providing Fire Alarm System, Providing, installation, testing and commissioning of Nextra Stretcher-passengers lift.
245Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
246Group C
247Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
248Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
249Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2502x1.5 sq.mm + 1x1.5 sq.mm earth wire
2514 X 4 sq. mm + 2 X 4 sq. mm earth wire
2524 X 6 sq. mm + 2 X 6 sq. mm earth wire
2534 X 10 sq. mm + 2 X 6 sq. mm earth wire
254Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing recessed PVC conduit as required.
2551 Pair
256Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
25725 mm
258Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
259Telephone socket outlet
260Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
261Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
2621 or 2 Module( 75mm X 75 mm)
263Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
264Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
265Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
266Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required.
267Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
268Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
269Upto 450 mm sweep
270Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
271Supplying and fixing PVC batten/ angle holder including connections etc. as required.
272Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
2734 way (4 + 12), Double door
274Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
275Single pole
276Supplying and Fixing single pole blanking plate in the existing MCB DB complete etc. as required.
277Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, 2 pole and earth, metal enclosed plug top along with 20 A, "C" curve, SP, MCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
278Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A, "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
279Providing and fixing 25mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connections with brass nut , bolt, spring, washer excavation and refilling etc. as required.
280Providing and fixing25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
281Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
282Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required.
283Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
284Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
285Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
286Upto 35 sq. mm
287Above 95 sq.mm and upto 185 sq.mm
288Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2892 x 6 sq.mm (19 mm)
2904 x 25 sq.mm (28 mm)
2913½ x 185 sq.mm (57 mm)
292Providing and fixing M.S. fan clamp type I or II16mm dia M.S. bar ,bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed beams during laying, including painting thje exposed portion of loop, all as per standard design complete.
293Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 grade stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
294Above 4.5 metre and upto 6.5 metre
295Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 grade stone aggregate 20 mm ) of specified size and shape including from work , plastering if required , curing etc. as required.(volume of pole / pipe not to be deducted ).
296Supplying and embedding following dia G.I. pipe( medium class) in pole collar/foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
29740 mm dia
298Supplying and fixing of light class G.I. pipeof 100 mm dia(nominal) 3 metres length along the pole for protection of under ground cable as required.
299Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
30063 mm dia (OD-63 mm & ID-51 mm nominal)
301120 mm dia (OD-120 mm & ID-103 mm nominal)
302Providing, laying and fixing following dia G.I. pipe ( medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required.
30350 mm dia
304100 mm dia
305Supplying,installation,testingandcommissioningof Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
3061 output per phase and suitable for single phase supply
307Supplying of AC ceiling fan of following sweep, BEE 5 star rated, ceiling fan with brushless direct current motor and other accessories, Power Factor not less than 0.9, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019) suitable for operation on 230 Volts, single phase, 50 Hz, AC Supply, earthing etc. complete as required.
3081200 mm sweep, white colour
309Supplying of heavy duty 900 RPM exhaust fan of following sweep, suitable for operation on 230 Volts, single phase, 50 Hz, AC Supply including suitable size louvers etc. as required.
310230 mm sweep
311Supplying of following BEE certified LED light fittings 1200 mm length, Power Factor not less than 0.9, suitable for 230 Volts, 50 Hz AC supply etc. as required.
31218W LED 6500K
313Supplying of following BEE certified LED light fittings 300 mm length, Power Factor not less than 0.9, suitable for 230 Volts, 50 Hz AC supply etc. as required.
3149W LED 4000K
315Supplying of surface mounted. Energy saving, decorative bulk head LED luminaire comprising of high brightness LEDs, IP66 protection fittings Similar to Havells Hexa 10W - IP66 complete etc. as required.
31610W 6000K
317Supplying of LED bulb of following power suitable for 230 Volts, 50 Hz AC supply as required.
318NU Bulb Plus 9W B22 4 Star
319Supplying & Fixing of new generation energy saving and environmental friendly long life LED street light fittings made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 similar to Havells Endura Pearl complete etc. as required.
32030W 5700K
321Supplying & fixing of new generation, post-top, energy saving, environmental friendly IP65 LED Gate/Post top light fittings of following capacity similar to Havells Ruby (clear)/ Coral (Opal) complete etc. as required
32225W 5700K Ruby
323Supplying & fixing of Surface mounted square shaped aesthetically designed 2x2 LED Flat panel which provides soft-light and glare free symmetrical illumination of following capacity similar to Havells Pluto complete etc. as required.
32434W 840 2x2
325Fabrication of street light pole 6.5 meters made up of GI pipe of sizes 65 mm & 40 mm dia. As per IS 1239 (Part I) 2004 along with G.I base plate 300X300X6 mm and earth stud etc as required.
326Providing and fixing hot press moulded sintex SMC junction Box of size 140x140x95 mm inside dimension with din rail for mounting MCB including supply of one 6A SPN MCB on poleat 0.5 metre hight from the ground level including connections etc as required.
327Supplying of following size ISI marked PVC insulated and PVC sheathed/ XLPE armoured aluminium conductor cable of 1.1 KV grade conforming to IS:7098 (part-I) as applicable etc. as required.
3282 core x 6 sq.mm
3294 core x 25 sq.mm
3303½ core x 185 sq.mm
331Supplying, Installation, testing and commissioning of following rating openwell submersible pumps Pump having Suction and Delivery pipe of size 32mm x 25mm suitable for 230V , 50Hz AC supplyincluding Foot Valve 32 mm, Starter, G.I Pipe and fittings etc as required.
3321.5 HP
333Supplying and fixing 240/415 V, "C" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
334SP MCB 0.5 A to 5 A , 10 KA capacity.Similar to Havells Cat. No.DHMGCSPF0x5-005.
335TPN MCB 40 A, 10 KA capacity.Similar to Havells Cat. No.DHMGCTNF040.
336TPN MCB 63 A, 10 KA capacity.Similar to Havells Cat. No.DHMGCTNF063
337Supplying and fixing ofOn Load Manual Change Over switchin Sheet Steel Enclosureof following currentratingof415 V, 50 Hz and Conforms to IS/IEC 60947-3) including connection etc as required.
338200 A
339Supplying and fixing of following rating Heavy duty double break HBC type triple pole & neutral fuse switchs in sheet steel enclosure including connection etc as required.
340200 A, 415 V, TPN, Similar to Havells item code.IHFNTW4200.
341Providing and fixing hot press moulded sintex three phase SMC Meter Box double door of size 505x240x150mm inside dimension with 4P 40A C-curve MCB, 415V for accommodating one LT 3 phase KWh meter and viewing window for MCB etc as required.
342Supplying, installation, testing and commissioning ofsafe earthing electro type-19, 50mm dia, length 2 mtrs (short time current -52.6 rms for 1 sec, peak-125.6) with back fill compoundand providing masonary enclosure with cover plate having locking arrangements etc. as required. MakeASHLOK SEE brand or its equivalent.
343SITC OF one "G" frame Double door Panel Board , incomer 250 A"AA" Frame MCCB and 6 way TP MCCBs G-frame outgoing quivalent to Havells CAT No.IHVG02500600 Including one setCable ally 6 way equivalent to CAT No. ISSBOU0692, add on Pre-Wired Meter Module with Voltmeter, Ammeter, Selector Switch, CT’s 250/0.5 A with0.2 accuracy classControl fuse and indicating lights equivalent to CAT No.ISSBOU0707 and supplying and fixing including making connections/ inter-connection of following switchgears etc. as required.
344(a) TP MCCB, 200A, 415V,50Hz 36 KA breaking capacity, Similar to Havells Cat No: IHLLSEC30200.= 01 No. (b) TP MCCB, 40A, 415V, 50Hz 16 KA breaking capacity - 02 Nos. (c ) TP MCCB, 25A, 415V, 50Hz 16 KA breaking capacity - 04 Nos.
345Supplying & fixing of call bell indicator and buzzer of 240 V, 50 Hz on the existing modular plate & switch box including connections but excluding modular plate etc. as required similar to Legrand Lyncus Cat No. 677249.
346Supplying & fixing of buzzer of 240 V, 50 Hz on the existing modular plate & switch box including connections with backlite 8-way connector strip 03 nos. but excluding modular plate etc. as required similar to Legrand Lyncus Cat No. 677250.
347SITC of 24 lines EPABX system (NEC SL2100) with maximum 06 Nos. trunck line and maximum 24 hybrid extensions, expandable upto 32 lines and maximum to 96 lines with additional cabinets by using following Tele accessoriesincluding connection complete as required.
348Cabinet with PSU for SL2100.similar to NEC model no. IP7WW-4KSU-C1.
349CPU CARD FOR SL2100 similar to NEC model no. IP7WW-CPU-C1.
35003 TRUNK & 08 Hybrid EXT. card similar to NEC model no. IP7WW-308U-A1 .
35108 EXT. card SL2100 similar to NEC model no. IP7WW-008U-C1.
35224 KEY HYBRID KTS similar to NEC model no. IP7WW-24TXH-A1.
353Supply andFixing of Push Button Telephone. Similar toBeetel B-15.
354Supplying and drawing following pair 0.4 mm dia PVC insulated annealed copper conductor, unarmoured telephone cable conforming to TECHNICAL specification G/WIR06/02 in the existing PVC recessed conduit etc. as required.
35510-Pair
356Supplying & installation of following Pair Distribution Box with krone module including connection etc as required.
35710-Pair
35820-Pair
359Supplying and fixing ofoffline UPS of following rating including connection as required. Make Zebronics.
3601000 VA
361Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ reccessed steel/ PVC conduit as required.
3622 x 1.5 sq.mm
363Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc as required.
364Supplying, installation, testing & commissioning of manual call boxes of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc as required.
365Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections (similar to Xper model XF-C06A) etc as required.
3664 Zone
367Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
368Supplying & fixing of following emergency LED light with showing direction for evacuation path similar to PROLITE Model PEL LED EM/B/UL924/65 complete with connection etc. as required.
369PROLITE Model PEL LED EM/ B/ UL924/ 65 LED Light
370Supplying & fixing of following emergency LED light with backup minimum 90 minutes similar to PROLITE Model TBL INFY SQ 2FT complete with connection etc. as required.
371PROLITE Model TBL INFY SQ 2FT LED Light
372Supplying & fixing of following size photoluminescent signages in english similar to PROLITE FE 64 complete etc. as required.
373450 x 300 mm
374Supplying & fixing of following size photoluminescent signages in hindi similar to PROLITE FE 64 complete etc. as required.
375450 x 300 mm
376Supplying & fixing of following size Safety signages of Non-Photo Lumininescent similar to PROLITE AUTOGLO Site Safety Signages or its equivalent complete etc. as required.
377250 x 350 mm
378Supplying & fixing of following size Auto glow flexible sheet emergency Exit Signages similar to PROLITE AUTOGLO Emergency way finding sytemsSignages complete etc. as required.
379100 x 400 mm
380200 x 400 mm
381Supplying & fixing of following size Auto glow Tapes/ Route markers similar to PROLITE AUTOGLO Emergency way finding sytemsSignages complete etc. as required.
38240 mm
38380 mm
384Supplying & fixing of following size Autoglo pathway marking Tape in the floor/ wall similar to PROLITE ALU RGD STR LLL.2 Model No - L complete etc. as required.
38590 mm
386Supplying & fixing of following size Auto glow fire evacuation plan similar to PROLITE AUTOGLO Fire Evacuation Plan & Safety Poster complete etc. as required.
387300 x 450 with Lamination
388Supplying & fixing of electrically operated Gong Bell, single phase, 240V, 50 Hz, AC of size 22 cms similar to Kheraj model GB-22 complete with connection etc. as required.
389Providing, installation, testing and Commissioning of 15 passenger (G+1) lift i/c electric driven motor, driving ropes, counter weight, all accessories and safety devices etc in CHC buildings at Diglipur. Make: OTIS, JOHNSON or other make of category A as mentioned in CPWD manual.
390Eessential Features Type of Lift - Nextra Stretcher-Passenger Load -15 persons (1020Kgs) Speed -1.00 mtr per second Drive -Micro processor based VVVF smooth power Total Travel -7 mtrs approximately Number of floors -2 (G + 1 Upper floor) No. of landing enterances -2 (G + 1 Upper floor) Number and Position of Car Entrance -One, in front only Position of Machinery -Directly above the lift well Size of lift well -2000 mm (w) x 2900 mm (D) Lift car inside size -1000 mm(W) X 2400 mm(D) X 2200 mm(H) Clear Door Opening -900 mm(W)X2000 mm(H) Pit size -1600 mm Over head -4500 mm Design of Lift car -Stainless Steel 1.5mm- Hair line finish Car ceiling -SS Hair line finish Car floor -SS Hair line finish
391Car fitting -LED Light, cross flow Fan with regulator Type of Car Door - SS Centre opening Automatic Door Type of Landing Door -SS Centre opening Automatic Door Type of landing frame -SS Hair line finish Type of control system -Microprocessor based VVVF Down collective Electric supply -AC 415 Volts, Three phases, 50 cycles Driving motor -PMSM (Permanent magnet synchronus motor) Brake -Electronic type which opens on energization with 24/48 VDC and closes by means of spring tension on deenergisation. The inner surface of the brake will be provided with brake liners. Driving ropes -USHA MARTIN / ORIENT make Electrical safety Device - a) Mains 3 phase limit switch to protect against over travel b) Single phase preventer with a protection against phase sequence reversal c) Full proof gate lock for landing doors d) Car gate switch e) Over speed governor f) Over speed safety device
392Special Inclusions Battery Operator Emergency light and Alarm bell Call Register signal and VF door operator Landing Push Button in Landing Door Frames Automaticrescue device Push button - Orange LED Illumimation Braille buttons for visually challenged persons inside the car and landings Full Car Operating Panel Dot Matrix LED D & P Indicators in Car and Landings-Orange Colour Floor Annunciator with music Firemans Switch False Ceiling in car Infra Red door screen Laminated Mirror at rear side Overload Warning Indicator Scaffolding 3 way intercom/ Press and Speak Phone Free service for one year Vandal proof s.s button with s.s cover Pit Ladder SS Handrail on three sides Provision for physically Handicapped
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail