Electrification Work Of Renovation Of Existing Rcc 2-Storied Ps Building With Provision Of Reception Etc In Existing Ps Under At Karimganj P.S. In Karimganj District Moitri Scheme. Electrification Work Of Renovation Of Existing Rcc 2-Storied Ps Building W, Karimganj P.S. in Karimganj District-Assam

Assam Police Housing Corporation Ltd has published Electrification Work Of Renovation Of Existing Rcc 2-Storied Ps Building With Provision Of Reception Etc In Existing Ps Under At Karimganj P.S. In Karimganj District Moitri Scheme. Electrification Work Of Renovation Of Existing Rcc 2-Storied Ps Building W. Submission Date for this Tender is 16-08-2021. Electrification Work Tenders in Karimganj P.S. in Karimganj District Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28761370
Electrification Work Of Renovation Of Existing Rcc 2-Storied Ps Building With Provision Of Reception Etc In Existing Ps Under At Karimganj P.S. In Karimganj District Moitri Scheme. Electrification Work Of Renovation Of Existing Rcc 2-Storied Ps Building W
Open Tender
Indian
Assam
Karimganj P.S. in Karimganj District
16-08-2021

Tender Details

Electrification Work Of Renovation Of Existing Rcc 2-Storied Ps Building With Provision Of Reception Etc In Existing Ps Under At Karimganj P.S. In Karimganj District Moitri Scheme. Electrification Work Of Renovation Of Existing Rcc 2-Storied Ps Building With Provision Of Reception Etc In Existing Ps Under At Karimganj P.S. In Karimganj District Moitri Scheme.

Key Value

Document Fees
INR 5000 /-
EMD
INR 114157.0 /-
Tender Value
INR 57.07 Lakhs /-

BOQ Items

Name of Work : Electrification works of Renovation of existing RCC 2-storied Police Station Building with provision of Reception & Conference Hall with Cyber Room & Work Station & Women Cell & Counseling Room for Drug ADICT & JUVENILE, Boundary Wall, Gate, Approach Road, Deep tube well, etc. in existing Police Station under at Karimganj P.S. in Karimganj District MOITRI Scheme.
Sl. No. Item Description
1Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete. Short point up to 3.00 metre. length.
2Medium point up to 6.00 metre. Length.
3Long point up to 10.00 metre. Length.
4Wiring for 5 pin 6 amp plug with 1.5 sq mmP.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socketas required on the switch board in surface/ recessedP.V.C. conduit wiring system. When fitted on same board of light and fan.
5Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVCconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
6Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
7With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
8With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cablein 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
9Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVC20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 6 sq. mm. + earth continuity with 2X4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
10With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
11Supplying and fitting fixing of Electric storage water heater [Geyser] ofBajaj/Crompton/Racold/V. Guard or equivalent make including necessary connection cable,as approved by the Deptt.)etc. as required complete and as directed by the Department. (I 15.00 litres. Capacity(5 Star Model)(Crompton/Racold/V. Guard or equivalent make)
12Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake)6 way TPN (4+18)double door
13Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 6 way SPN double door
148 way SPN double door
1512 way SPN double door
16Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hagermake) 6 to 32A
17Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake) 6 to 32A
1840A
19Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake)40A
2063A
21Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure)of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB125A (Schneider, legrand, Siemens, Indo Asianmake)
22Supplying with fitting and fixing Four Pole 415V Front handle operated open execution On Load Change over switchfitted on the existing cubical panel of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider, legrand, L&Tmake) 125 A
23Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 0.85M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of Enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 4nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:1. 20mm X 3mm 4 strip copper Bus-Bar 1.0 M length each 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch- 2 no 6. 2 A Slide fuse unit - 3nos (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
24Supply, installation & testing of Copper Plate earth station with600 mmx600 mmx3 mm copper earth plate withnecessary 40 mm dia. G.I. medium duty watering pipewith G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
25Supply, installation & testing of G.I. Plate earth station with600 mmx600 mmx6 mm heavy duty G.I. earth plate withnecessary 40 mm dia. G.I. watering pipewith G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mmhinged cover C.I. cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
26Extra for using salt (5 Kand Charcoal (96 Kin G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
27Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
28Supplying & laying of32*6 mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
29Supplying & laying offollowingsize 25*4 mm Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply ofBrass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
30Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 50 mm dia. 3.00 Metres length corrosion free dual pipetechnology G.I.CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 Kand Advance Earth Pit cover (PVincluding excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
31Supply with fitting, fixing ofLED Tube Light 20 Watt (Bajaj/ Polycab/ Philips)
32Supply with fitting, fixing of Edge LED Street Light luminaries 45 Watt LED (Bajaj/ Syska/ Crompton)
33Supply with fitting, fixing of Slim compact, aluminium die cast edge lit panel recessed mounted round fixture with opal diffuser and separate electronic driver 12 W LED (Havells/ Jaquar/ Philips)
34Suppliying and fixing of Jaquar or equivalent Philips/Wipro LED spot light fittings complete with Shade,back plate including connection cable,as approved by the Deptt.s etc. as required. LED Square front spot light,3W
35Supplying including fitting fixing of followingA.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator].Premium model1200 mm Sweep (ORIENT PSPOmake) / Premium model 1050 /1200 mm Sweep SS-390 Deco Havellsmake)
36Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
37Supplying including fitting fixing of followingA.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. (CROMPTON /ORIENT/Havells/USHA or equivalentmake) Swing platinawith plastic blade, 400 mm sweep
38Supply with fitting and fixing of 120 Watt electronic modular STEP speed control 2-modue type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE),MK (BLENZE), SCHINEDER (ZENSELO), CRABTREE (MURANO) including making necessary connections as per direction of deptt. 120 Watt electronic modular step speed control 2-module type BLK
39Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Power Flow225 mm sweep (ORIENTmake)
40Supplying with installation testing and commissioning of Hi -- wall 4 STAR rating non ducted split typeair conditioner of the following capacity with cordless remote complete withindoor and outdoor unit, copper pipeand electrical connection as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department. 1.5 Ton capacity 3. Blue Starmake) Model 4WAE181YA
41Supplying with fitting and fixing of Angle iron framing made 50 mmx50 mmx5 mm size angle iron for accommodation of 1.00 Ton to 2.00 Ton Window/split type A.C. Machine
42Copper pipeincluding cable fitting ( 1/4,1/2,5/8)
43Supplying with fitting & fixing of 25 Amp modular motor starter 2 Amp MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
44Supplying with fitting and fixingVoltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUSmake) 4.0 KVA Automatic Input 90-280 V Out put 200-240 V
45Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 armoured U.G. cableU.G. cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .3 & 1/2 Core A2XFY70.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
46Supplying including installtion of socket outlet 10/16 Amps 3/5 pin combine shuttered complete, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connections as per direction of deptt.
47Supply with fitting and fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connections as per direction of deptt.
48Supply with fitting and fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connections as per direction of deptt.
49Supply including installation of socket outlet 6/10/13 Amps International Socket, Model Range Legrand (Arteor), Achor (Ave), MK (Blenze), Schneider (Zenselo), Crabtree (Murano) including making necessary connection as per direction of department
50Supply with fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) in surface/recessed system complete as per direction of deptt. 1-2 module type Metal
513 module type Metal
524 module type Metal
536 module type Metal
5412 module type Metal
5518 module type Metal
56Supplying including fitting & fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) front plate of suitable color as per direction of deptt. 2 module
573 module
584 module
596 module
6012 module
6118 module
62Supplying including fitting & fixing of TV SOCKETMODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
63Supply and laying of following size gas injected physical polyethylene foam insulation with laminated Al tape and Al braid, jelly flooded PVC black jacketed industrial co-axial cable armoured cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .RG 11 armoured
64Supply and fixing of 19 mm dia 1.50mm to 2.00mm average wall thicknessheavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface systemincluding painting etc as required:
65Supply and fixing of 25 mm dia 1.50mm to 2.00mm average wall thicknessheavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface systemincluding painting etc as required:
66Supplying with fitting & fixing of CAT 6 RJ-45 computerjack in one module, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
67Supply with fitting, fixing of8 port LAN Switch (D-Link)
68Supply with fitting, fixing of4U rack with accessories (HCL/D-Link)
69Supplying with fitting & fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
70Supplying with fitting & fixing of 6 Amp one way modular clip in bell push MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/PLUS), ABB (CHEIRON), KOLORS (KRESP), SCHNEIDER (VIVACE), CRABTREE including making necessary connectionss as per direction of deptt.
71Supplying with fitting & fixing of following moulded PVC boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/PLUS), ABB (CHEIRON), KOLORS (KRESP), SCHNEIDER (VIVACE), CRABTREE in surface system complete as per direction of deptt. 1-3 module surface moulded PVC boxex
728 module surface moulded PVC boxex
7312 module horizantal surface moulded PVC boxex
74Supply, installation, testing & commissioning of Distributaion box 20 pairs with Krones (SIEMENS or equivalent s approved by the deptt.)
75Supply, installation, testing & commissioning ofUROSET 2005 Analog Hand set (SIEMENS or equivalent s approved by the deptt.)
76Supply, installation, testing & commissioning of 2 pair Unarmoured Telephone cable through existing conduit in surface/recess system.
77Supplying ,installation, testing & commissioning of 20 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.
78Supplying with fitting & fixing of RJ-11 Telephone jack, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
79Supplying and fitting fixing of Hi-Path 1150M Digital Communication System equipped with the following: 2 P&T Ports - 10 Extension Ports (upgradeable up to 34 extensions)Auto Call Back, Built-in FAX/DID Built in Voice Guided Direct inward Dialling 3 party Conference In-built Caller ID 100% Non- Block( SIEMENSor equivalent as approved by the Deptt.)
80Supplying ,installation, testing & commissioning of Dedicated EPABX Earthing for trouble free operation( SIEMENSor equivalent as approved by the Deptt.)
81Supply, installation, testing and commissioning of SITC of Network TDN IR Indoor Dome Camera 2 Mega Pixel 3.6mm Fixed Lens, Inbuilt audio, 24 IR LED"s for Night Vision, PoE, H.265 (Honeywell/ Panasonic)
82Supply, installation, testing and commissioning of SITC of Network TDN IR Outdoor Bullet Camera 2 Mega Pixel 3.6mm to 12 mm very focal Lens, IR LEDs for 30mtrs. Night Vision, PoE, H.265(Honeywell/ Panasonic)
83Supply, installation, testing and commissioning of SITC of 8 Channel Network Video Recorder, 1 SATA HDD Slot(Max 8TB), Real Time recording Resolution, Real time Local Playback , Multiplex operation, H.264 High profile, BNC/VGA/HDMI output, Main Profile baseline, HDD redundancy, Free DDNS, Network backup, USB HDD, USB Writer, SATA Writer, 1 RS485, support 18 kinds of PTZ protocols, ONVIF 2.0 (Honeywell)
84Supply with Fitting and fixing of SAITC of 6TB Surveillance Hard Disc Drive (SEGATE/ WD)
85Supply with fitting, fixing of SITC 8 port Gigabit Power Over Ethernet 8* RJ45 Switch 10/100M (D-Link/ Hikvision)
86Supplying installation testing and commissioning of 22" LCD TFT Screen (SAMSUNG / ball / LG / MITASHImake)
87Supplying installation testing and commissioning of UPS 1 KVA for Back Up (ball / ELNOVA / APCmake)
88Supplying installation testing of UTP CAT6 without PVC conduit
89Supplying including installation, testing and commissioning ofAir/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f.(la mounted on a1)M.S. Fabricated base frame.,2)M.S. fuel tank of required capacity.,3)Residual Silencer.,4) Standard Control Panel.5)Suitable batteries with lead.,5) First fill of lubeoil.,6)Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KVA) Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator. KVA- PHASE- Approx size- Approx Wt-COOLING 30 3 3130x1100x1680 1440 Kg W/C
90Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 armoured U.G. cableU.G. cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 2 Core A2XWaY A2XFaY 6.00 Sq.mm 2 Core armoured U.G. cable
9135.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
92Supplying and fixing 50 mm dia ISI marked hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) on surface including painting etc. as required:
93Supplying including installation, testing and commissioning of Solar power plant as per following specification and as directed by the Department.1.92 KWp STANDALONE SOLAR POWER PLANT Load: 1000 Watts for 4 Hrs/Day Back up Or, Load: 500 Watts for 8 Hrs/Day Back up Crystalline Solar PV Module - TBP1280M/ TBP1280 with RDSO Part-I Approval (as per IRS S: 84/92 or latest Amdt.) & IEC: 61215 Certification. 24 nos Crystalline Solar PV Module - TBP1280M/ TBP1280 with RDSO Part-I Approval (as per IRS S: 84/92 or latest Amdt.) & IEC: 61215 Certification. 24 nos( 2) 4 Module mounting structure with theft proof frame 6 nos (3) Array Junction Box (AJ 2 nos( 4) Main Junction Box (MJ 1 no (5) Power Conditioning Unit (PCU) – 48V DC- 2KVA- 230V AC, 50Hz 1 no (6 )Battery Bank-Tubular Plate LMLA Battery Bank of 48V, 300Ah @ C10 1 set (7) 2C X 2.5 Sq.mm. P.V.C Cu.cable 100 metres (8 )2C X 6.0 Sq.mm. P.V.C Cu.cable 50 metres (9) 2C X 10 Sq.mm. P.V.C Cu.cable 30 metres (10) 1C X 25 Sq.mm. P.V.C Cu.cable 20 metres (11) Earthing kit 6 nos (12) Installation kit 1 set Note: All cable lengths are estimated. Extra cables, if any, shall be charged extra at actual. All cable lengths are calculated from the Solar Array to input of the Power Conditioning Unit (PCU). Loads & Load cables are not included in the Bill of Materials. SUGGESTED UNIT PRICE Unit Cost Without Installation & Commissioning)
94Installation & Commissioning Charges
95Supplying including installation, testing and commissioning of Solar Street light as per following specification and as directed by the Department.15 W LED SOLAR STREET LIGHT [Confirming RDSO Specification No: RDSO/PE/SPEC/PS/0093-2008(Rev 0)] SYSTEM SPECIFICATION 15 W LED based luminaries/fixture (1500 Lumens –typical) LED Type: White High Powered LED’s 5500-6500 K temperature. Automatic Dusk to Dawn Operate ion. Independent standalone Solar Street Lighting System. Powered by a 12V, 80 Wp Solar PV Module confirming RDSO Part-I Approval & IEC: 61215 Certification. (Model: TBP 1280/ 1280M). (make: TATA BP SOLAR or equivalent) 12V, 75Ah @ C10, Tubular Plate Lead Acid Low Maintenance Battery with PP Container (make: TATA BP SOLAR or equivalent). Battery Box made of M.S fabricated with corrosion resistance paint. 6m height MS Pole with corrosion resistance paint. Manufacturers Criteria: Must have ISO: 9001 & ISO: 14001 Certification. (As per Annexure A: Clause no: b, Page 10) Must have integrated production capacity of Solar PV Cell & Module. (As per Annexure A: Clause no: d, Page: 10) SUGGESTED UNIT PRICE
96Installation & Commissioning Charges
97Supplying and erection PSC pole 9.75 metre long, the pole is to be erection in 1:3:6 plain cement concrete foundation of size 1.50 m x 0.45 m x 0.45m having P.C.C base foundation 15 cm x 60 cm x 60cm including edge brick soiling and plastering above G.L. portion (0.30 metrecomplete with excavation of earth, handling of Surplus Soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department.
98Supplying and fitting fixing pole clamp complete as required and as directed by the department.
99Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular polemanufacturing out from electrically welded in 3 (threesection having a base plate including providing all required building materials as directed and specified by the deptt. (BANSAL/SRP / Valmont / PARUTHI ENGRmake) 410 SP 66 Length of pole = 12.00 metre., Length of sections,Bottom = 5.80 M, Middle = 3.10 M, Top = 3.10 M, Out side dia. & Thickness Bottom = 219.10 x 5.60 mm, Middle =193.7 x 4.85 mm, Top =165.10 x 4.50 mm
100Supplying and string up AAAC Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department.
101Supplying and fitting fixing of 11 KV T Cross arm complete with clamps ,blots, nuts etc. as required andas directed by the department.
102Supplying installation testing and commissioning of the following rating copper wound indoor/out door type transformer complete including the payment to be made to power supply authority for supervision charge,labour charge,cost of L.T/H.T. metering etc.(excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the deptt. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 Star,above 200 KVA as per CEA guidelines for losses along with LV enclosure. 63 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
103Supplying and fitting fixing of Galvanised channel of 100mm X 65mm x 2200mm Long complete with clamps,blots,nuts etc as required and as directed by the dep"t.
104Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories completee as required and as directed by the dep"t.
105Supplying and fixing of 11 KV 5 KA Lighting arrestor(Poly) set completee as required and as directed by the dep"t.
106Supplying and fixing of 11 KV150 AD.O. fuse set completee as required and as directed by the dep"t.
107Supplying and erection of 11 KV Pin insulator (Poly)with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
108Supplying and erection of H.T. stay set complete (Galvanized) with 19 mm dia x 1.8 m long stay rod, anchor plate of size 30 cm x 30 cm x 6.4 mm thimble sty clamps tube buckle (19 mm x 60 cm)7/3.15mm dia G.I. stayand strain insulation etc. in cement concrete 1:3:6 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the deptt.
109Supplying including installation of 4" dia C.I. earth pipe complete as required and as directed by the dep"t.
110Extra for using salt (5 Kand Charcoal (64 Kin pipeEarth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
111Supplying including installation of 11 KV Ct/Pt combine metering system complete asrequired and as directed by the dep"t.
112Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the dep"t.
1133 Phase 4 4ire ICS DLMS complaint HT Trivector energy meter (category-A)
114LT XLPE cable 50 sq mm (1 core armour)
115SUPPLYING FITTING AND FIXING OF(DOWELLS/ COMETmake) ALUMINIUM tube terminal. ALUMINIUM tube terminal. Size: 70
116Steel Metering Cabinate
117AMR
118L.T.C.T. 100/5 Amp
119Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 laid in air or through existing cable trench/duct/ cable tray/ HDPE pipeincluding fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .Core - 1, A2XWY 4x35 Sq.mm single core armoured cable
120DTR Fencing as per REC standard specification complete with material and labour
121Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1)1988, laid in air or through existing cable trench/duct/ cable tray/ HDPE pipeincluding fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . CONTROL cable Unarmoured 2XY2.5 sq mm 12 core Unarmoured
122Civil Work- Construction of Generator Shed
123Electric Load Security, Meter Security, Court agreement fees, inspection fees etc for all the necessary proceddings for comissioning of the Substation
124Maintenance Lagacy for 3 (three) Years1st Year Free2nd Year Ground Floor :
1251st Floor :
126AT 1st Floor
1273rd Year Ground Floor :
1283rd Year1st Floor :
1293rd YearAT 1st Floor:
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail